On-Chip Construction of Liver Lobules with Self-Assembled Perfusable Hepatic Sinusoid Networks
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Although various liver chips have been developed using emerging organ-on-a-chip techniques, it remains an enormous challenge to replicate the liver lobules with self-assembled perfusable hepatic sinusoid networks. Herein we develop a lifelike bionic liver lobule chip (LLC), on which the perfusable hepatic sinusoid networks are achieved using a microflow-guided angiogenesis methodology; additionally, during and after self-assembly, oxygen concentration is regulated to mimic physiologically dissolved levels supplied by actual hepatic arterioles and venules. This liver lobule design thereby produces more bionic liver microstructures, higher metabolic abilities, and longer lasting hepatocyte function than other liver-on-a-chip techniques that are able to deliver. We found that the flow through the unique micropillar design in the cell coculture zone guides the radiating assembly of the hepatic sinusoid, the oxygen concentration affects the morphology of the sinusoid by proliferation, and the oxygen gradient plays a key role in prolonging hepatocyte function. The expected breadth of applications our LLC is suited to is demonstrated by means of preliminarily testing chronic and acute hepatotoxicity of drugs and replicating growth of tumors in situ. This work provides new insights into designing more extensive bionic vascularized liver chips, while achieving longer lasting ex-vivo hepatocyte function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flow-enhanced vascularization and maturation of kidney organoids in vitro
Homan, K. A., Gupta, N., Kroll, K. T., Kolesky, D. B., Skylar-Scott, M., Miyoshi, T., Mau, D., Valerius, M. T., Ferrante, T., Bonventre, J. V., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0325-y · Cited by 939
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872
Maschmeyer, I., Lorenz, A. K., Schimek, K., Hasenberg, T., Ramme, A. P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00392j · Cited by 861
A liver-on-a-chip platform with bioprinted hepatic spheroids
Bhise, N. S., Manoharan, V., Massa, S., Tamayol, A., Ghaderi, M., Miscuglio, M., Lang, Q., Shrike Zhang, Y., Shin, S. R., Calzone, G., et al. (2016) · Biofabrication · doi:10.1088/1758-5090/8/1/014101 · Cited by 615
Reproducing human and cross-species drug toxicities using a liver-chip
Jang, K.-J., Otieno, M. A., Ronxhi, J., Lim, H.-K., Ewart, L., Kodella, K. R., Petropolis, D. B., Kulkarni, G., Rubins, J. E., Conegliano, D., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aax5516 · Cited by 511
Metabolic zonation of the liver: The oxygen gradient revisited
Kietzmann, T. (2017) · Redox Biology · doi:10.1016/j.redox.2017.01.012 · Cited by 499
3D microtumors in vitro supported by perfused vascular networks
Sobrino, A., Phan, D. T. T., Datta, R., Wang, X., Hachey, S. J., Romero-López, M., Gratton, E., Lee, A. P., George, S. C., & Hughes, C. C. W. (2016) · Scientific Reports · doi:10.1038/srep31589 · Cited by 387
A vascularized and perfused organ-on-a-chip platform for large-scale drug screening applications
Phan, D. T. T., Wang, X., Craver, B. M., Sobrino, A., Zhao, D., Chen, J. C., Lee, L. Y. N., George, S. C., Lee, A. P., & Hughes, C. C. W. (2017) · Lab on a Chip · doi:10.1039/c6lc01422d · Cited by 325
Xu, Z., Li, E., Guo, Z., Yu, R., Hao, H., Xu, Y., Sun, Z., Li, X., Lyu, J., & Wang, Q. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b08746 · Cited by 264
Mimicking liver sinusoidal structures and functions using a 3D-configured microfluidic chip
Du, Y., Li, N., Yang, H., Luo, C., Gong, Y., Tong, C., Gao, Y., Lü, S., & Long, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01374k · Cited by 241
3D microfluidic liver cultures as a physiological preclinical tool for hepatitis B virus infection
Ortega-Prieto, A. M., Skelton, J. K., Wai, S. N., Large, E., Lussignol, M., Vizcay-Barrena, G., Hughes, D., Fleck, R. A., Thursz, M., Catanese, M. T., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-02969-8 · Cited by 236
Liver-cell patterning lab chip: mimicking the morphology of liver lobule tissue
Ho, C.-T., Lin, R.-Z., Chen, R.-J., Chin, C.-K., Gong, S.-E., Chang, H.-Y., Peng, H.-L., Hsu, L., Yew, T.-R., Chang, S.-F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50402f · Cited by 230
Long‐term maintenance of a microfluidic 3D human liver sinusoid
Prodanov, L., Jindal, R., Bale, S. S., Hegde, M., McCarty, W. J., Golberg, I., Bhushan, A., Yarmush, M. L., & Usta, O. B. (2016) · Biotechnology and Bioengineering · doi:10.1002/bit.25700 · Cited by 214
A lung/liver-on-a-chip platform for acute and chronic toxicity studies
Bovard, D., Sandoz, A., Luettich, K., Frentzel, S., Iskandar, A., Marescotti, D., Trivedi, K., Guedj, E., Dutertre, Q., Peitsch, M. C., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc01029c · Cited by 195
An On-Chip Small Intestine–Liver Model for Pharmacokinetic Studies
Kimura, H., Ikeda, T., Nakayama, H., Sakai, Y., & Fujii, T. (2015) · SLAS Technology · doi:10.1177/2211068214557812 · Cited by 136
Liver-on-a-Chip models of fatty liver disease
Hassan, S., Sebastian, S., Maharjan, S., Lesha, A., Carpenter, A., Liu, X., Xie, X., Livermore, C., Zhang, Y. S., & Zarrinpar, A. (2020) · Hepatology · doi:10.1002/hep.31106 · Cited by 127
Self-citationChallenges and Opportunities in the Design of Liver-on-Chip Microdevices
Ehrlich, A., Duche, D., Ouedraogo, G., & Nahmias, Y. (2019) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-060418-052305 · Cited by 125
Microengineered Liver Tissues for Drug Testing
Khetani, S. R., Berger, D. R., Ballinger, K. R., Davidson, M. D., Lin, C., & Ware, B. R. (2015) · SLAS Technology · doi:10.1177/2211068214566939 · Cited by 116
The physiology of oxygen transport
Habler, O. P., & Messmer, K. F. W. (1997) · Transfusion Science · doi:10.1016/s0955-3886(97)00041-6 · Cited by 113
The modular microarchitecture of human liver†
Teutsch, H. F. (2005) · Hepatology · doi:10.1002/hep.20764 · Cited by 91
Engineered Liver Platforms for Different Phases of Drug Development
Ware, B. R., & Khetani, S. R. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.08.001 · Cited by 90
Ozkan, A., Ghousifam, N., Hoopes, P. J., Yankeelov, T. E., & Rylander, M. N. (2019) · Biotechnology and Bioengineering · doi:10.1002/bit.26919 · Cited by 73
An in vitro hepatic zonation model with a continuous oxygen gradient in a microdevice
Sato, A., Kadokura, K., Uchida, H., & Tsukada, K. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.10.017 · Cited by 40
Construction of sinusoid-scale microvessels in perfusion culture of a decellularized liver
Watanabe, M., Yano, K., Okawa, K., Yamashita, T., Tajima, K., Sawada, K., Yagi, H., Kitagawa, Y., Tanishita, K., & Sudo, R. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.12.042 · Cited by 38
Cited by
Constructing biomimetic liver models through biomaterials and vasculature engineering
Lv, W., Zhou, H., Aazmi, A., Yu, M., Xu, X., Yang, H., Huang, Y. Y. S., & Ma, L. (2022) · Regenerative Biomaterials · doi:10.1093/rb/rbac079 · Cited by 45
Developing Liver Microphysiological Systems for Biomedical Applications
Wang, J., Wu, X., Zhao, J., Ren, H., & Zhao, Y. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202302217 · Cited by 27
Dufva, M. (2023) · Scientific Reports · doi:10.1038/s41598-023-35043-5 · Cited by 14
Metadata
- Authors
- Ya, S., Ding, W., Li, S., Du, K., Zhang, Y., Li, C., Liu, J., Li, F., Li, P., Luo, T., He, L., Xu, A., Gao, D., & Qiu, B.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2021-07-06
- Volume
- 13
- Issue
- 28
- Pages
- 32640-32652
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W3178533026
- Cited by
- 61
- References
- 24
- FWCI
- 2.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.