The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Noncontact Heartbeat and Respiration Monitoring Based on a Hollow Microstructured Self-Powered Pressure Sensor
Abstract
Advances in mobile networks and low-power electronics have driven smart mobile medical devices at a tremendous pace, evoking increased interest in household healthcare, especially for those with cardiovascular or respiratory disease. Thus, flexible battery-free pressure sensors, with great potential for monitoring respiration and heartbeat in a smart way, are urgently demanded. However, traditional flexible battery-free pressure sensors for subtle physiological signal detecting are mostly tightly adhered onto the skin instead of working under the pressure of body weight in a noncontact mode, as the low sensitivity in the high-pressure region can hardly meet the demands. Moreover, a hollow microstructure (HM) with higher deformation than solid microstructures and great potential for improving the pressure sensitivity of self-powered sensors has never been investigated. Here, for the first time, we demonstrated a noncontact heartbeat and respiration monitoring system based on a flexible HM-enhanced self-powered pressure sensor, which possesses the advantages of low cost, a high dynamic-pressure sensitivity of 18.98 V·kPa –1, and a wide working range of 40 kPa simultaneously. Specific superiority of physiological detection under a high pressure is also observed. Continuous reliable heartbeat and respiration information is successfully detected in a noncontact mode and transmitted to a mobile phone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review
Amjadi, M., Kyung, K., Park, I., & Sitti, M. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504755 · Cited by 3,202
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042
A flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres
Pang, C., Lee, G.-Y., Kim, T.-I., Kim, S. M., Kim, H. N., Ahn, S.-H., & Suh, K.-Y. (2012) · Nature Materials · doi:10.1038/nmat3380 · Cited by 1,695
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Persano, L., Dagdeviren, C., Su, Y., Zhang, Y., Girardo, S., Pisignano, D., Huang, Y., & Rogers, J. A. (2013) · Nature Communications · doi:10.1038/ncomms2639 · Cited by 1,271
Park, J., Lee, Y., Hong, J., Ha, M., Jung, Y.-D., Lim, H., Kim, S. Y., & Ko, H. (2014) · ACS Nano · doi:10.1021/nn500441k · Cited by 915
Park, J., Lee, Y., Hong, J., Lee, Y., Ha, M., Jung, Y., Lim, H., Kim, S. Y., & Ko, H. (2014) · ACS Nano · doi:10.1021/nn505953t · Cited by 649
Park, S., Kim, H., Vosgueritchian, M., Cheon, S., Kim, H., Koo, J. H., Kim, T. R., Lee, S., Schwartz, G., Chang, H., et al. (2014) · Advanced Materials · doi:10.1002/adma.201402574 · Cited by 565
Flexible suspended gate organic thin-film transistors for ultra-sensitive pressure detection
Zang, Y., Zhang, F., Huang, D., Gao, X., Di, C.-A., & Zhu, D. (2015) · Nature Communications · doi:10.1038/ncomms7269 · Cited by 548
Ha, M., Lim, S., Park, J., Um, D., Lee, Y., & Ko, H. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201500453 · Cited by 395
Cited by
Microengineering Pressure Sensor Active Layers for Improved Performance
Ruth, S. R. A., Feig, V. R., Tran, H., & Bao, Z. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202003491 · Cited by 538
Self‐Powered Respiration Monitoring Enabled By a Triboelectric Nanogenerator
Su, Y., Chen, G., Chen, C., Gong, Q., Xie, G., Yao, M., Tai, H., Jiang, Y., & Chen, J. (2021) · Advanced Materials · doi:10.1002/adma.202101262 · Cited by 481
Flexible Wearable Sensors for Cardiovascular Health Monitoring
Chen, S., Qi, J., Fan, S., Qiao, Z., Yeo, J. C., & Lim, C. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100116 · Cited by 453
Self-citationYang, J., Luo, S., Zhou, X., Li, J., Fu, J., Yang, W., & Wei, D. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b02049 · Cited by 433
Zhou, Z., Padgett, S., Cai, Z., Conta, G., Wu, Y., He, Q., Zhang, S., Sun, C., Liu, J., Fan, E., et al. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112064 · Cited by 313
Metadata
- Authors
- Chen, S., Wu, N., Ma, L., Lin, S., Yuan, F., Xu, Z., Li, W., Wang, B., & Zhou, J.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-01-17
- Volume
- 10
- Issue
- 4
- Pages
- 3660-3667
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2782155276
- Cited by
- 170
- References
- 13
- FWCI
- 6.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.