The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Anodized Aluminum Oxide-Assisted Low-Cost Flexible Capacitive Pressure Sensors Based on Double-Sided Nanopillars by a Facile Fabrication Method
Abstract
Flexible pressure sensors have garnered enormous attention in recent years as they hold great promise in wearable electronic devices. However, the realization of a high-performance flexible pressure sensor via a facile and cost-effective approach still remains a challenge. In this work, a capacitive pressure sensor based on a poly(vinylidenefluoride- co -trifluoroethylene) [P(VDF-TrFE)] dielectric film that incorporates nanopillars into both sides is demonstrated. Unlike the previous complicated and expensive methods, large-scale regular and uniform nanopillars are easily and economically achieved by the pattern transfer of anodized aluminum oxide templates. The double-sided nanopillars constituting the P(VDF-TrFE) dielectric layer enable the pressure sensor with high sensitivity (∼0.35 kPa –1 ), wide working range (4 Pa to 25 kPa), short response time (∼48 ms), and excellent durability. In addition to these salient features, our sensor also exhibits superior performances under bending states, ensuring that it can be used for detecting diverse practical stimuli as experimentally validated by perceiving real-time and in-site human physiological signals and body motions that, respectively, correspond to the low- and high-pressure range. A sensor array is finally constructed and is shown to be capable of perceiving the spatial pressure distribution of either a contact or noncontact object. These demonstrations show a promising future of our sensor in healthcare monitoring, smart robot skin, and human–machine interfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Ultrasensitive mechanical crack-based sensor inspired by the spider sensory system
Kang, D., Pikhitsa, P. V., Choi, Y. W., Lee, C., Shin, S. S., Piao, L., Park, B., Suh, K.-Y., Kim, T.-I., & Choi, M. (2014) · Nature · doi:10.1038/nature14002 · Cited by 1,626
Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients
Blacher, J., Asmar, R., Djane, S., London, G. M., & Safar, M. E. (1999) · Hypertension · doi:10.1161/01.hyp.33.5.1111 · Cited by 1,493
Stretchable silicon nanoribbon electronics for skin prosthesis
Kim, J., Lee, M., Shim, H. J., Ghaffari, R., Cho, H. R., Son, D., Jung, Y. H., Soh, M., Choi, C., Jung, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms6747 · Cited by 1,435
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Nanowire active-matrix circuitry for low-voltage macroscale artificial skin
Takei, K., Takahashi, T., Ho, J. C., Ko, H., Gillies, A. G., Leu, P. W., Fearing, R. S., & Javey, A. (2010) · Nature Materials · doi:10.1038/nmat2835 · Cited by 1,274
User-interactive electronic skin for instantaneous pressure visualization
Wang, C., Hwang, D., Yu, Z., Takei, K., Park, J., Chen, T., Ma, B., & Javey, A. (2013) · Nature Materials · doi:10.1038/nmat3711 · Cited by 1,182
Recent Advances in Flexible and Stretchable Bio‐Electronic Devices Integrated with Nanomaterials
Choi, S., Lee, H., Ghaffari, R., Hyeon, T., & Kim, D. (2016) · Advanced Materials · doi:10.1002/adma.201504150 · Cited by 1,104
Wu, W., Wen, X., & Wang, Z. L. (2013) · Science · doi:10.1126/science.1234855 · Cited by 931
Kim, K. K., Hong, S., Cho, H. M., Lee, J., Suh, Y. D., Ham, J., & Ko, S. H. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b01505 · Cited by 626
Cited by
Flexible and Stretchable Capacitive Sensors with Different Microstructures
Qin, J., Yin, L., Hao, Y., Zhong, S., Zhang, D., Bi, K., Zhang, Y., Zhao, Y., & Dang, Z. (2021) · Advanced Materials · doi:10.1002/adma.202008267 · Cited by 616
Sharma, S., Chhetry, A., Sharifuzzaman, M., Yoon, H., & Park, J. Y. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c05819 · Cited by 454
Progress of flexible strain sensors for physiological signal monitoring
Shen, Z., Liu, F., Huang, S., Wang, H., Yang, C., Hang, T., Tao, J., Xia, W., & Xie, X. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114298 · Cited by 250
Yuan, H., Zhang, Q., Zhou, T., Wu, W., Li, H., Yin, Z., Ma, J., & Jiao, T. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.149926 · Cited by 180
Nanostructured perovskites for nonvolatile memory devices
Liu, Q., Gao, S., Xu, L., Yue, W., Zhang, C., Kan, H., Li, Y., & Shen, G. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00886b · Cited by 163
Self-citation
Metadata
- Authors
- Guo, Y., Gao, S., Yue, W., Zhang, C., & Li, Y.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-11-26
- Volume
- 11
- Issue
- 51
- Pages
- 48594-48603
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2990618388
- Cited by
- 219
- References
- 14
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Anodized Aluminum Oxide-Assisted Low-Cost Flexible Capacitive Pressure Sensors Based on Double-Sided Nanopillars by a Facile Fabrication Method. https://app.cochat.ai/papers/10.1021/acsami.9b17966
- The paper
- Guo, Y., Gao, S., Yue, W., Zhang, C., & Li, Y. (2019). Anodized Aluminum Oxide-Assisted Low-Cost Flexible Capacitive Pressure Sensors Based on Double-Sided Nanopillars by a Facile Fabrication Method. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.9b17966
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.