CoChat

Highly Elastic and Moldable Polyester Biomaterial for Cardiac Tissue Engineering Applications

Davenport Huyer, Locke, Zhang, Boyang, Korolj, Anastasia, Montgomery, Miles, Drecun, Stasja, Conant, Genevieve, Zhao, Yimu, Reis, Lewis, Radisic, Milica · 2016 · ACS Biomaterials Science & Engineering
Cited by 100

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Polyester biomaterials are used in tissue engineering as scaffolds for implantation of tissues developed in vitro. An ideal biodegradable elastomer for cardiac tissue engineering exhibits a relatively low Young's modulus, with high elongation and tensile strength. Here we describe a novel polyester biomaterial that exhibits improved elastic properties for cardiac tissue engineering applications. We synthesized poly(octamethylene maleate (anhydride) 1,2,4-butanetricarboxylate) (124 polymer) prepolymer gel in a one-step polycondensation reaction. The prepolymer was then molded as desired and exposed to ultraviolet (UV) light to produce a cross-linked elastomer. 124 polymer exhibited highly elastic properties under aqueous conditions that were tunable according to the UV light exposure, monomer composition, and porosity of the cured elastomer. Its elastomeric properties fell within the range of adult heart myocardium, but they could also be optimized for higher elasticity for weaker immature constructs. The polymer showed relatively stable degradation characteristics, both hydrolytically and in a cellular environment, suggesting maintenance of material properties as a scaffold support for potential tissue implants. When assessed for cell interaction, this polymer supported rat cardiac cell attachment in vitro as well as comparable acute in vivo host response when compared to poly(l-lactic acid) control. This suggests the potential applicability of this material as an elastomer for cardiac tissue engineered constructs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsbiomaterials.5b00525

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 100

Metadata

Authors
Davenport Huyer, L., Zhang, B., Korolj, A., Montgomery, M., Drecun, S., Conant, G., Zhao, Y., Reis, L., & Radisic, M.
Venue
ACS Biomaterials Science & Engineering
Published
2016-04-28
Volume
2
Issue
5
Pages
780-788
ISSN
2373-9878 (ISSN-L)
OpenAlex
W2344600570
Cited by
100
References
10
FWCI
3.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly Elastic and Moldable Polyester Biomaterial for Cardiac Tissue Engineering Applications. https://app.cochat.ai/papers/10.1021/acsbiomaterials.5b00525
The paper
Davenport Huyer, L., Zhang, B., Korolj, A., Montgomery, M., Drecun, S., Conant, G., Zhao, Y., Reis, L., & Radisic, M. (2016). Highly Elastic and Moldable Polyester Biomaterial for Cardiac Tissue Engineering Applications. ACS Biomaterials Science & Engineering. https://doi.org/10.1021/acsbiomaterials.5b00525

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.