Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 167

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Highly Thermal-Wet Comfortable and Conformal Silk-Based Electrodes for On-Skin Sensors with Sweat Tolerance

Open access
Li, Qingsong, Chen, Geng, Cui, Yajing, Ji, Shaobo, Liu, Zhiyuan, Wan, Changjin, Liu, Yuping, Lu, Yehu, Wang, Changxian, Zhang, Nan, Cheng, Yuan, Zhang, Ke-Qin, Chen, Xiaodong·2021·ACS Nano

Abstract

Noninvasive and seamless interfacing between the sensors and human skin is highly desired for wearable healthcare. Thin-film-based soft and stretchable sensors can to some extent form conformal contact with skin even under dynamic movements for high-fidelity signals acquisition. However, sweat accumulation underneath these sensors for long-term monitoring would compromise the thermal-wet comfort, electrode adherence to the skin, and signal fidelity. Here, we report the fabrication of a highly thermal-wet comfortable and conformal silk-based electrode, which can be used for on-skin electrophysiological measurement under sweaty conditions. It is realized through incorporating conducting polymers poly(3,4-ethylenedioxythiophene): polystyrenesulfonate (PEDOT:PSS) into glycerol-plasticized silk fiber mats. Glycerol plays the role of tuning the mechanical properties of silk fiber mats and enhancing the conductivity of PEDOT:PSS. Our silk-based electrodes show high stretchability (>250%), low thermal insulation (∼0.13 °C·m 2 ·W –1 ), low evaporative resistance (∼23 Pa·m 2 ·W –1, 10 times lower than ∼1.3 mm thick commercial gel electrodes), and high water-vapor transmission rate (∼117 g·m –2 ·h –1 under sweaty conditions, 2 times higher than skin water loss). These features enable a better electrocardiography signal quality than that of commercial gel electrodes without disturbing the heat dissipation during sweat evaporation and provide possibilities for textile integration to monitor the muscle activities under large deformation. Our glycerol-plasticized silk-based electrodes possessing superior physiological comfortability may further engage progress in on-skin electronics with sweat tolerance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsnano.1c01431

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 167

Metadata

Authors
Li, Q., Chen, G., Cui, Y., Ji, S., Liu, Z., Wan, C., Liu, Y., Lu, Y., Wang, C., Zhang, N., Cheng, Y., Zhang, K.-Q., & Chen, X.
Venue
ACS Nano
Published
2021-06-10
Volume
15
Issue
6
Pages
9955-9966
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W3170999054
Cited by
167
References
10
FWCI
7.70
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly Thermal-Wet Comfortable and Conformal Silk-Based Electrodes for On-Skin Sensors with Sweat Tolerance. https://app.cochat.ai/papers/10.1021/acsnano.1c01431
The paper
Li, Q., Chen, G., Cui, Y., Ji, S., Liu, Z., Wan, C., Liu, Y., Lu, Y., Wang, C., Zhang, N., Cheng, Y., Zhang, K.-Q., & Chen, X. (2021). Highly Thermal-Wet Comfortable and Conformal Silk-Based Electrodes for On-Skin Sensors with Sweat Tolerance. ACS Nano. https://doi.org/10.1021/acsnano.1c01431

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.