The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Diagnosis and Classification of 17 Diseases from 1404 Subjects via Pattern Analysis of Exhaled Molecules
Open accessAbstract
We report on an artificially intelligent nanoarray based on molecularly modified gold nanoparticles and a random network of single-walled carbon nanotubes for noninvasive diagnosis and classification of a number of diseases from exhaled breath. The performance of this artificially intelligent nanoarray was clinically assessed on breath samples collected from 1404 subjects having one of 17 different disease conditions included in the study or having no evidence of any disease (healthy controls). Blind experiments showed that 86% accuracy could be achieved with the artificially intelligent nanoarray, allowing both detection and discrimination between the different disease conditions examined. Analysis of the artificially intelligent nanoarray also showed that each disease has its own unique breathprint, and that the presence of one disease would not screen out others. Cluster analysis showed a reasonable classification power of diseases from the same categories. The effect of confounding clinical and environmental factors on the performance of the nanoarray did not significantly alter the obtained results. The diagnosis and classification power of the nanoarray was also validated by an independent analytical technique, i.e., gas chromatography linked with mass spectrometry. This analysis found that 13 exhaled chemical species, called volatile organic compounds, are associated with certain diseases, and the composition of this assembly of volatile organic compounds differs from one disease to another. Overall, these findings could contribute to one of the most important criteria for successful health intervention in the modern era, viz. easy-to-use, inexpensive (affordable), and miniaturized tools that could also be used for personalized screening, diagnosis, and follow-up of a number of diseases, which can clearly be extended by further development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnosing lung cancer in exhaled breath using gold nanoparticles
Peng, G., Tisch, U., Adams, O., Hakim, M., Shehada, N., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., & Haick, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.235 · Cited by 1,263
Self-citationA review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Effect of aging on respiratory system physiology and immunology
Sharma, G., & Goodwin, J. (2006) · Clinical Interventions in Aging · doi:10.2147/ciia.2006.1.3.253 · Cited by 1,037
Volatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953
Self-citationVolatile organic compounds in breath as markers of lung cancer: a cross-sectional study
Phillips, M., Gleeson, K., Hughes, J. M. B., Greenberg, J., Cataneo, R. N., Baker, L., & McVay, W. P. (1999) · The Lancet · doi:10.1016/s0140-6736(98)07552-7 · Cited by 918
Human exhaled air analytics: biomarkers of diseases
Buszewski, B., Kęsy, M., Ligor, T., & Amann, A. (2007) · Biomedical Chromatography · doi:10.1002/bmc.835 · Cited by 792
Peng, G., Hakim, M., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., Tisch, U., & Haick, H. (2010) · British Journal of Cancer · doi:10.1038/sj.bjc.6605810 · Cited by 775
Self-citationAssessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Self-citationSensors for Breath Testing: From Nanomaterials to Comprehensive Disease Detection
Konvalina, G., & Haick, H. (2014) · Accounts of Chemical Research · doi:10.1021/ar400070m · Cited by 561
Self-citationNanomaterial-Based Sensors for Detection of Disease by Volatile Organic Compounds
Broza, Y. Y., & Haick, H. (2013) · Nanomedicine · doi:10.2217/nnm.13.64 · Cited by 358
Self-citation
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
Carbon Nanotube Chemical Sensors
Schroeder, V., Savagatrup, S., He, M., Lin, S., & Swager, T. M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00340 · Cited by 1,131
Biomarkers in Lung Cancer Screening: Achievements, Promises, and Challenges
Seijo, L. M., Peled, N., Ajona, D., Boeri, M., Field, J. K., Sozzi, G., Pio, R., Zulueta, J. J., Spira, A., Massion, P. P., et al. (2019) · Journal of Thoracic Oncology · doi:10.1016/j.jtho.2018.11.023 · Cited by 539
Self-citationSensors for Volatile Organic Compounds
Khatib, M., & Haick, H. (2022) · ACS Nano · doi:10.1021/acsnano.1c10827 · Cited by 533
Self-citationBroza, Y. Y., Zhou, X., Yuan, M., Qu, D., Zheng, Y., Vishinkin, R., Khatib, M., Wu, W., & Haick, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00437 · Cited by 461
Self-citationBreath Sensors for Health Monitoring
Güntner, A. T., Abegg, S., Königstein, K., Gerber, P. A., Schmidt-Trucksäss, A., & Pratsinis, S. E. (2019) · ACS Sensors · doi:10.1021/acssensors.8b00937 · Cited by 410
Multiplexed Nanomaterial-Based Sensor Array for Detection of COVID-19 in Exhaled Breath
Shan, B., Broza, Y. Y., Li, W., Wang, Y., Wu, S., Liu, Z., Wang, J., Gui, S., Wang, L., Zhang, Z., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c05657 · Cited by 384
Self-citationElectronic Noses: From Advanced Materials to Sensors Aided with Data Processing
Hu, W., Wan, L., Jian, Y., Ren, C., Jin, K., Su, X., Bai, X., Haick, H., Yao, M., & Wu, W. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201800488 · Cited by 366
Self-citationAdvanced Materials for Health Monitoring with Skin‐Based Wearable Devices
Jin, H., Abu‐Raya, Y. S., & Haick, H. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700024 · Cited by 317
Self-citationNanosensors for water quality monitoring
Vikesland, P. J. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0209-9 · Cited by 287
Ingestible electronics for diagnostics and therapy
Steiger, C., Abramson, A., Nadeau, P., Chandrakasan, A. P., Langer, R., & Traverso, G. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0070-3 · Cited by 274
Innovative Nanosensor for Disease Diagnosis
Kim, S.-J., Choi, S.-J., Jang, J.-S., Cho, H.-J., & Kim, I.-D. (2017) · Accounts of Chemical Research · doi:10.1021/acs.accounts.7b00047 · Cited by 264
Koh, H.-J., Kim, S. J., Maleski, K., Cho, S.-Y., Kim, Y.-J., Ahn, C. W., Gogotsi, Y., & Jung, H.-T. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00310 · Cited by 257
Recent Progress in Sensor Arrays: From Construction Principles of Sensing Elements to Applications
Li, T., Zhu, X., Hai, X., Bi, S., & Zhang, X. (2023) · ACS Sensors · doi:10.1021/acssensors.2c02596 · Cited by 257
Artificial Intelligence in Medical Sensors for Clinical Decisions
Haick, H., & Tang, N. (2021) · ACS Nano · doi:10.1021/acsnano.1c00085 · Cited by 231
Self-citationFlexible Plasmonic Biosensors for Healthcare Monitoring: Progress and Prospects
Song, L., Chen, J., Xu, B. B., & Huang, Y. (2021) · ACS Nano · doi:10.1021/acsnano.1c07176 · Cited by 186
Electronic nose: a non-invasive technology for breath analysis of diabetes and lung cancer patients
Behera, B., Joshi, R., Anil Vishnu, G. K., Bhalerao, S., & Pandya, H. J. (2019) · Journal of Breath Research · doi:10.1088/1752-7163/aafc77 · Cited by 179
Machine Learning-Based Rapid Detection of Volatile Organic Compounds in a Graphene Electronic Nose
Capman, N. S. S., Zhen, X. V., Nelson, J. T., Chaganti, V. R. S. K., Finc, R. C., Lyden, M. J., Williams, T. L., Freking, M., Sherwood, G. J., Bühlmann, P., et al. (2022) · ACS Nano · doi:10.1021/acsnano.2c10240 · Cited by 115
Electrical sensing of volatile organic compounds in exhaled breath for disease diagnosis
Yan, H., & Zhou, Y.-G. (2022) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2021.100922 · Cited by 29
Metadata
- Authors
- Nakhleh, M. K., Amal, H., Jeries, R., Broza, Y. Y., Aboud, M., Gharra, A., Ivgi, H., Khatib, S., Badarneh, S., Har-Shai, L., Glass-Marmor, L., Lejbkowicz, I., Miller, A., Badarny, S., Winer, R., Finberg, J., Cohen-Kaminsky, S., Perros, F., Montani, D., Girerd, B., Garcia, G., Simonneau, G., Nakhoul, F., Baram, S., Salim, R., Hakim, M., Gruber, M., Ronen, O., Marshak, T., Doweck, I., Nativ, O., Bahouth, Z., Shi, D.-Y., Zhang, W., Hua, Q.-L., Pan, Y.-Y., Tao, L., Liu, H., Karban, A., Koifman, E., Rainis, T., Skapars, R., Sivins, A., Ancans, G., Liepniece-Karele, I., Kikuste, I., Lasina, I., Tolmanis, I., Johnson, D., Millstone, S. Z., Fulton, J., Wells, J. W., Wilf, L. H., Humbert, M., Leja, M., Peled, N., & Haick, H.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-12-21
- Volume
- 11
- Issue
- 1
- Pages
- 112-125
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2564083981
- Cited by
- 510
- References
- 66
- FWCI
- 24.17
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.