Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 453

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Bioinspired Ultrasensitive and Stretchable MXene-Based Strain Sensor via Nacre-Mimetic Microscale “Brick-and-Mortar” Architecture

Shi, Xinlei, Wang, Huike, Xie, Xueting, Xue, Qingwen, Zhang, Jingyu, Kang, Siqi, Wang, Conghui, Liang, Jiajie, Chen, Yongsheng·2019·ACS Nano

Abstract

The development of wearable strain sensors with simultaneous large stretchability (strain >55%) and high sensitivity (gauge factor >100) remains a grand challenge to this day. Drawing on inspiration from nature, nacre has demonstrated outstanding mechanical properties, especially combining high strength and toughness, which is due in part to its delicate hierarchical layered architecture with rich interfacial interactions. We demonstrate that strain sensors based on this nacre-mimetic microscale “brick-and-mortar” architecture can simultaneously achieve ultrahigh sensitivity and large stretchability while performing well in linearity, reliability, long-term durability, and monotonicity. The bioinspired sensor demonstrated a gauge factor >200 over a range of working strains up to 83% and achieved a high gauge factor exceeding 8700 in the strain region of 76–83%. This successful combination of high sensitivity and large stretchability is attributed to (1) the microscale hierarchical architecture derived from the amalgamation of 2D titanium carbide (MXene) Ti 3 C 2 T x /1D silver nanowire “brick” and poly(dopamine)/Ni 2+ “mortar” and (2) the synergistic toughing effects from interfacial interactions of hydrogen and coordination bonding, layer slippage, and molecular chain stretching. The synergistic behavior of the “brick” and “mortar” allows for controlled crack generation for high sensitivity but can also dissipate considerable loading energy to promote the stepwise propagation of cracks while stretching, guaranteeing the significant comprehensive sensing performance. Moreover, this bioinspired strain sensor is employed to monitor human activities under different motion states to demonstrate its feasibility for wearable, full-spectrum human health and motion monitoring systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsnano.8b07805

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 453

Metadata

Authors
Shi, X., Wang, H., Xie, X., Xue, Q., Zhang, J., Kang, S., Wang, C., Liang, J., & Chen, Y.
Venue
ACS Nano
Published
2018-12-19
Volume
13
Issue
1
Pages
649-659
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W2904858388
Cited by
453
References
9
FWCI
13.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bioinspired Ultrasensitive and Stretchable MXene-Based Strain Sensor via Nacre-Mimetic Microscale “Brick-and-Mortar” Architecture. https://app.cochat.ai/papers/10.1021/acsnano.8b07805
The paper
Shi, X., Wang, H., Xie, X., Xue, Q., Zhang, J., Kang, S., Wang, C., Liang, J., & Chen, Y. (2019). Bioinspired Ultrasensitive and Stretchable MXene-Based Strain Sensor via Nacre-Mimetic Microscale “Brick-and-Mortar” Architecture. ACS Nano. https://doi.org/10.1021/acsnano.8b07805

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.