Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 655

The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.

Self-Folding Thermo-Magnetically Responsive Soft Microgrippers

Open access
Breger, Joyce C., Yoon, ChangKyu, Xiao, Rui, Kwag, Hye Rin, Wang, Martha O., Fisher, John P., Nguyen, Thao D., Gracias, David H.·2015·ACS Applied Materials & Interfaces

Abstract

Hydrogels such as poly(N-isopropylacrylamide-co-acrylic acid) (pNIPAM-AAc) can be photopatterned to create a wide range of actuatable and self-folding microstructures. Mechanical motion is derived from the large and reversible swelling response of this cross-linked hydrogel in varying thermal or pH environments. This action is facilitated by their network structure and capacity for large strain. However, due to the low modulus of such hydrogels, they have limited gripping ability of relevance to surgical excision or robotic tasks such as pick-and-place. Using experiments and modeling, we design, fabricate, and characterize photopatterned, self-folding functional microgrippers that combine a swellable, photo-cross-linked pNIPAM-AAc soft-hydrogel with a nonswellable and stiff segmented polymer (polypropylene fumarate, PPF). We also show that we can embed iron oxide (Fe2O3) nanoparticles into the porous hydrogel layer, allowing the microgrippers to be responsive and remotely guided using magnetic fields. Using finite element models, we investigate the influence of the thickness and the modulus of both the hydrogel and stiff polymer layers on the self-folding characteristics of the microgrippers. Finally, we illustrate operation and functionality of these polymeric microgrippers for soft robotic and surgical applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/am508621s

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 4

  1. Nguyen, 2004, A Polymeric Microgripper with Integrated Thermal Actuators, J. Micromech. Microeng., 14, 969, 10.1088/0960-1317/14/7/018 · doi:10.1088/0960-1317/14/7/018
  2. Chronis, 2005, Electrothermally Activated SU-8 Microgripper for Single Cell Manipulation in Solution, J. Microelectromech. Syst., 14, 857, 10.1109/JMEMS.2005.845445 · doi:10.1109/jmems.2005.845445
  3. Kuo, 2014, A Hydrogel-Based Intravascular Microgripper Manipulated Using Magnetic Fields, Sens. Actuators, A, 211, 121, 10.1016/j.sna.2014.02.028 · doi:10.1016/j.sna.2014.02.028
  4. Guo, 2005, Organic-Dye-Coupled Magnetic Nanoparticles Encaged Inside Thermoresponsive PNIPAM Microcapsules, Small, 1, 737, 10.1002/smll.200400145 · doi:10.1002/smll.200400145

Cited by

See all 655

Metadata

Authors
Breger, J. C., Yoon, C., Xiao, R., Kwag, H. R., Wang, M. O., Fisher, J. P., Nguyen, T. D., & Gracias, D. H.
Venue
ACS Applied Materials & Interfaces
Published
2015-01-28
Volume
7
Issue
5
Pages
3398-3405
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2335171300
Cited by
655
References
47
FWCI
40.54
Type
journal article
Language
en
Open access
hybrid
Funders
  • NIH Office of the Director (DP2-OD004346-01)
  • National Institute of Arthritis and Musculoskeletal and Skin Diseases (R01 AR0614606)
  • National Institute of Biomedical Imaging and Bioengineering (R01EB017742)
  • National Institute of Dental and Craniofacial Research (R01 DE013740)
  • Division of Chemical, Bioengineering, Environmental, and Transport Systems (CBET-1066898)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.