The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Responsive MRI Agents for Sensing Metabolism in Vivo
Open accessAbstract
Magnetic resonance imaging (MRI) has inherent advantages in safety, three-dimensional output, and clinical relevance when compared with optical and radiotracer imaging methods. However, MRI contrast agents are inherently less sensitive than agents used in other imaging modalities primarily because MRI agents are detected indirectly by changes in either the water proton relaxation rates (T(1), T(2), and T(*)(2)) or water proton intensities (chemical exchange saturation transfer and paramagnetic chemical exchange saturation transfer, CEST and PARACEST). Consequently, the detection limit of an MRI agent is determined by the characteristics of the background water signal; by contrast, optical and radiotracer-based methods permit direct detection of the agent itself. By virtue of responding to background water (which reflects bulk cell properties), however, MRI contrast agents have considerable advantages in "metabolic" imaging, that is, spatially resolving tissue variations in pH, redox state, oxygenation, or metabolite levels. In this Account, we begin by examining sensitivity limits in targeted contrast agents and then address contrast agents that respond to a physiological change; these responsive agents are effective metabolic imaging sensors. The sensitivity requirements for a metabolic imaging agent are quite different from those for a targeted Gd(3+)-based T(1) agent (for example, sensing cell receptors). Targeted Gd(3+) agents must have either an extraordinarily high water proton relaxivity (r(1)) or multiple Gd(3+) complexes clustered together at the target site on a polymer platform or nanoparticle assembly. Metabolic MRI agents differ in that the high relaxivity requirement, although helpful, is eased because these agents respond to bulk properties of tissues rather than low concentrations of a specific biological target. For optimal sensing, metabolic imaging agents should display a large change in relaxivity (deltar(1)) in response to the physiological or metabolic parameter of interest. Metabolic imaging agents have only recently begun to appear in the literature and only a few have been demonstrated in vivo. MRI maps of absolute tissue pH have been obtained with Gd(3+)-based T(1) sensors. The requirement of an independent measure of agent concentration in tissues complicates these experiments, but if qualitative changes in tissue pH are acceptable, then these agents can be quite useful. In this review, we describe examples of imaging extracellular pH in brain tumors, ischemic hearts, and pancreatic islets with Gd(3+)-based pH sensors and discuss the potential of CEST and PARACEST agents as metabolic imaging sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gadolinium(III) Chelates as MRI Contrast Agents: Structure, Dynamics, and Applications
Caravan, P., Ellison, J. J., McMurry, T. J., & Lauffer, R. B. (1999) · Chemical Reviews · doi:10.1021/cr980440x · Cited by 4,483
Iron oxide MR contrast agents for molecular and cellular imaging
Bulte, J. W. M., & Kraitchman, D. L. (2004) · NMR in Biomedicine · doi:10.1002/nbm.924 · Cited by 1,500
Ward, K. M., Aletras, A. H., & Balaban, R. S. (2000) · Journal of Magnetic Resonance · doi:10.1006/jmre.1999.1956 · Cited by 1,429
Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI
Zhou, J., Payen, J.-F., Wilson, D. A., Traystman, R. J., & van Zijl, P. C. M. (2003) · Nature Medicine · doi:10.1038/nm907 · Cited by 1,198
In vivo visualization of gene expression using magnetic resonance imaging
Louie, A. Y., Hüber, M. M., Ahrens, E. T., Rothbächer, U., Moats, R., Jacobs, R. E., Fraser, S. E., & Meade, T. J. (2000) · Nature Biotechnology · doi:10.1038/73780 · Cited by 1,141
Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo
Rooney, W. D., Johnson, G., Li, X., Cohen, E. R., Kim, S., Ugurbil, K., & Springer, C. S. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21122 · Cited by 652
Chemical exchange saturation transfer imaging and spectroscopy
Zhou, J., & Zijl, P. C. M. V. (2006) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2006.01.001 · Cited by 485
Chemical Exchange Saturation Transfer Contrast Agents for Magnetic Resonance Imaging
Sherry, A. D., & Woods, M. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151929 · Cited by 356
Self-citationPerez, J. M., O'Loughin, T., Simeone, F. J., Weissleder, R., & Josephson, L. (2002) · Journal of the American Chemical Society · doi:10.1021/ja017773n · Cited by 355
Gd(III)-BASED CONTRAST AGENTS FOR MRI
AIME, S., BOTTA, M., & TERRENO, E. (2005) · Advances in Inorganic Chemistry · doi:10.1016/s0898-8838(05)57004-1 · Cited by 345
A “Smart” Magnetic Resonance Imaging Agent That Reports on Specific Enzymatic Activity
Moats, R. A., Fraser, S. E., & Meade, T. J. (1997) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199707261 · Cited by 330
McMahon, M. T., Gilad, A. A., Zhou, J., Sun, P. Z., Bulte, J. W. M., & van Zijl, P. C. M. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20818 · Cited by 330
A Novel pH‐Sensitive MRI Contrast Agent
Zhang, S., Wu, K., & Sherry, A. D. (1999) · Angewandte Chemie International Edition · Cited by 259
Self-citationMR contrast agents, the old and the new
Bellin, M.-F. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2006.06.021 · Cited by 247
Atanasijevic, T., Shusteff, M., Fam, P., & Jasanoff, A. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0606749103 · Cited by 242
Extracellular gadolinium-based contrast media: An overview
Bellin, M.-F., & Van Der Molen, A. J. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.01.023 · Cited by 226
A Peptoid “Antibody Surrogate” That Antagonizes VEGF Receptor 2 Activity
Udugamasooriya, D. G., Dineen, S. P., Brekken, R. A., & Kodadek, T. (2008) · Journal of the American Chemical Society · doi:10.1021/ja711193x · Cited by 222
Chen, W., Tomalia, D. A., & Thomas, J. L. (2000) · Macromolecules · doi:10.1021/ma000791p · Cited by 185
MRI Thermometry Based on PARACEST Agents
Zhang, S., Malloy, C. R., & Sherry, A. D. (2005) · Journal of the American Chemical Society · doi:10.1021/ja053799t · Cited by 173
Self-citationHigh resolution pHe imaging of rat glioma using pH‐dependent relaxivity
Garcia‐Martin, M. L., Martinez, G. V., Raghunand, N., Sherry, A. D., Zhang, S., & Gillies, R. J. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20773 · Cited by 164
Self-citationSynthesis and Relaxometric Studies of a Dendrimer‐Based pH‐Responsive MRI Contrast Agent
Ali, M. M., Woods, M., Caravan, P. D., Opina, A. C. L., Spiller, M., Fettinger, J. C., & Sherry, A. D. (2008) · Chemistry - A European Journal · doi:10.1002/chem.200800402 · Cited by 120
Self-citationTerreno, E., Castelli, D. D., Cravotto, G., Milone, L., & Aime, S. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000116607.26372.d0 · Cited by 116
Dendritic PARACEST contrast agents for magnetic resonance imaging
Pikkemaat, J. A., Wegh, R. T., Lamerichs, R. M. J. N., van de Molengraaf, R. A., Langereis, S., Burdinski, D., Raymond, A. Y. F., Janssen, H. M., de Waal, B. F. M., Willard, N. P., et al. (2007) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.149 · Cited by 103
Imaging the tissue distribution of glucose in livers using a PARACEST sensor
Ren, J., Trokowski, R., Zhang, S., Malloy, C. R., & Sherry, A. D. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21722 · Cited by 78
Self-citationCyclen-Based Phenylboronate Ligands and Their Eu3+ Complexes for Sensing Glucose by MRI
Trokowski, R., Zhang, S., & Sherry, A. D. (2004) · Bioconjugate Chemistry · doi:10.1021/bc0498976 · Cited by 69
Self-citationDetermination of nanoparticle vehicle unpackaging by MR imaging of a T2 magnetic relaxation switch
Park, I., Ng, C. P., Wang, J., Chu, B., Yuan, C., Zhang, S., & Pun, S. H. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.10.018 · Cited by 62
Raghunand, N., Zhang, S., Sherry, A. D., et al. (2002) · Academic Radiology · doi:10.1016/s1076-6332(03)80270-2 · Cited by 51
Self-citation
Cited by
A Molecular Imaging Primer: Modalities, Imaging Agents, and Applications
James, M. L., & Gambhir, S. S. (2012) · Physiological Reviews · doi:10.1152/physrev.00049.2010 · Cited by 1,140
Dunn, W. B., Broadhurst, D. I., Atherton, H. J., Goodacre, R., & Griffin, J. L. (2011) · Chem. Soc. Rev. · doi:10.1039/b906712b · Cited by 860
Chemical Design and Synthesis of Functionalized Probes for Imaging and Treating Tumor Hypoxia
Liu, J.-N., Bu, W., & Shi, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00525 · Cited by 838
Alternatives to Gadolinium-Based Metal Chelates for Magnetic Resonance Imaging
Viswanathan, S., Kovacs, Z., Green, K. N., Ratnakar, S. J., & Sherry, A. D. (2010) · Chemical Reviews · doi:10.1021/cr900284a · Cited by 439
Self-citationZaiss, M., & Bachert, P. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/r221 · Cited by 323
Metadata
- Authors
- De Leon-Rodriguez, L. M., Lubag, A. J. M., Malloy, C. R., Martinez, G. V., Gillies, R. J., & Sherry, A. D.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-03-06
- Volume
- 42
- Issue
- 7
- Pages
- 948-957
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W1988754328
- Cited by
- 256
- References
- 27
- FWCI
- 16.27
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.