The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Folding-Based Electrochemical Biosensors: The Case for Responsive Nucleic Acid Architectures
Open accessAbstract
Biomolecular recognition is versatile, specific, and high affinity, qualities that have motivated decades of research aimed at adapting biomolecules into a general platform for molecular sensing. Despite significant effort, however, so-called "biosensors" have almost entirely failed to achieve their potential as reagentless, real-time analytical devices; the only quantitative, reagentless biosensor to achieve commercial success so far is the home glucose monitor, employed by millions of diabetics. The fundamental stumbling block that has precluded more widespread success of biosensors is the failure of most biomolecules to produce an easily measured signal upon target binding. Antibodies, for example, do not change their shape or dynamics when they bind their recognition partners, nor do they emit light or electrons upon binding. It has thus proven difficult to transduce biomolecular binding events into a measurable output signal, particularly one that is not readily spoofed by the binding of any of the many potentially interfering species in typical biological samples. Analytical approaches based on biomolecular recognition are therefore mostly cumbersome, multistep processes relying on analyte separation and isolation (such as Western blots, ELISA, and other immunochemical methods); these techniques have proven enormously useful, but are limited almost exclusively to laboratory settings. In this Account, we describe how we have refined a potentially general solution to the problem of signal detection in biosensors, one that is based on the binding-induced "folding" of electrode-bound DNA probes. That is, we have developed a broad new class of biosensors that employ electrochemistry to monitor binding-induced changes in the rigidity of a redox-tagged probe DNA that has been site-specifically attached to an interrogating electrode. These folding-based sensors, which have been generalized to a wide range of specific protein, nucleic acid, and small-molecule targets, are rapid (responding in seconds to minutes), sensitive (detecting sub-picomolar to micromolar concentrations), and reagentless. They are also greater than 99% reusable, are supported on micrometer-scale electrodes, and are readily fabricated into densely packed sensor arrays. Finally, and critically, their signaling is linked to a binding-specific change in the physics of the probe DNA, and not simply to adsorption of the target onto the sensor head. Accordingly, they are selective enough to be employed directly in blood, crude soil extracts, cell lysates, and other grossly contaminated clinical and environmental samples. Indeed, we have recently demonstrated the ability to quantitatively monitor a specific small molecule in real-time directly in microliters of flowing, unmodified blood serum. Because of their sensitivity, substantial background suppression, and operational convenience, these folding-based biosensors appear potentially well suited for electronic, on-chip applications in pathogen detection, proteomics, metabolomics, and drug discovery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
Anderson, N. L., & Anderson, N. G. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r200007-mcp200 · Cited by 4,414
Molecular Beacons: Probes that Fluoresce upon Hybridization
Tyagi, S., & Kramer, F. R. (1996) · Nature Biotechnology · doi:10.1038/nbt0396-303 · Cited by 4,155
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Enzyme-linked immunosorbent assay (ELISA) quantitative assay of immunoglobulin G
Engvall, E., & Perlmann, P. (1971) · Immunochemistry · doi:10.1016/0019-2791(71)90454-x · Cited by 3,777
Selection of single-stranded DNA molecules that bind and inhibit human thrombin
Bock, L. C., Griffin, L. C., Latham, J. A., Vermaas, E. H., & Toole, J. J. (1992) · Nature · doi:10.1038/355564a0 · Cited by 2,469
UPDIKE, S. J., & HICKS, G. P. (1967) · Nature · doi:10.1038/214986a0 · Cited by 1,336
Selection in vitro of an RNA enzyme that specifically cleaves single-stranded DNA
Robertson, D. L., & Joyce, G. F. (1990) · Nature · doi:10.1038/344467a0 · Cited by 1,331
Fan, C., Plaxco, K. W., & Heeger, A. J. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1633515100 · Cited by 1,043
Self-citation
Cited by
Zhou, W., Saran, R., & Liu, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00063 · Cited by 931
Device integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
Photoelectrochemical DNA Biosensors
Zhao, W.-W., Xu, J.-J., & Chen, H.-Y. (2014) · Chemical Reviews · doi:10.1021/cr500100j · Cited by 857
Using personal glucose meters and functional DNA sensors to quantify a variety of analytical targets
Xiang, Y., & Lu, Y. (2011) · Nature Chemistry · doi:10.1038/nchem.1092 · Cited by 677
Electrochemistry of Nucleic Acids
Paleček, E., & Bartošík, M. (2012) · Chemical Reviews · doi:10.1021/cr200303p · Cited by 668
Dai, Y., Somoza, R. A., Wang, L., Welter, J. F., Li, Y., Caplan, A. I., & Liu, C. C. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201910772 · Cited by 660
Aptamer-integrated DNA nanostructures for biosensing, bioimaging and cancer therapy
Meng, H.-M., Liu, H., Kuai, H., Peng, R., Mo, L., & Zhang, X.-B. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00645g · Cited by 608
Rational, modular adaptation of enzyme-free DNA circuits to multiple detection methods
Li, B., Ellington, A. D., & Chen, X. (2011) · Nucleic Acids Research · doi:10.1093/nar/gkr504 · Cited by 534
Feng, L., Chen, Y., Ren, J., & Qu, X. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.01.002 · Cited by 476
Adsorption of DNA onto gold nanoparticles and graphene oxide: surface science and applications
Liu, J. (2012) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp41186e · Cited by 408
Arduini, F., Micheli, L., Moscone, D., Palleschi, G., Piermarini, S., Ricci, F., & Volpe, G. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.01.032 · Cited by 395
Triplex DNA Nanostructures: From Basic Properties to Applications
Hu, Y., Cecconello, A., Idili, A., Ricci, F., & Willner, I. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201701868 · Cited by 336
Detection and beyond: challenges and advances in aptamer-based biosensors
Yoo, H., Jo, H., & Oh, S. S. (2020) · Materials Advances · doi:10.1039/d0ma00639d · Cited by 334
Aptamer-Based Electrochemical Biosensor for Interferon Gamma Detection
Liu, Y., Tuleouva, N., Ramanculov, E., & Revzin, A. (2010) · Analytical Chemistry · doi:10.1021/ac101409t · Cited by 324
Paleček, E., Tkáč, J., Bartošík, M., Bertók, T., Ostatná, V., & Paleček, J. (2015) · Chemical Reviews · doi:10.1021/cr500279h · Cited by 319
Liu, P., Yang, X., Sun, S., Wang, Q., Wang, K., Huang, J., Liu, J., & He, L. (2013) · Analytical Chemistry · doi:10.1021/ac4001157 · Cited by 302
Aptamer Modules as Sensors and Detectors
Famulok, M., & Mayer, G. (2011) · Accounts of Chemical Research · doi:10.1021/ar2000293 · Cited by 300
Graphene Platform for Hairpin-DNA-Based Impedimetric Genosensing
Bonanni, A., & Pumera, M. (2011) · ACS Nano · doi:10.1021/nn200091p · Cited by 298
Non‐invasive Analyte Access and Sensing through Eccrine Sweat: Challenges and Outlook circa 2016
Heikenfeld, J. (2016) · Electroanalysis · doi:10.1002/elan.201600018 · Cited by 294
Rationally Engineered Nucleic Acid Architectures for Biosensing Applications
Xiao, M., Lai, W., Man, T., Chang, B., Li, L., Chandrasekaran, A. R., & Pei, H. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00121 · Cited by 290
Shen, J., Li, Y., Gu, H., Xia, F., & Zuo, X. (2014) · Chemical Reviews · doi:10.1021/cr300248x · Cited by 273
Kesler, V., Murmann, B., & Soh, H. T. (2020) · ACS Nano · doi:10.1021/acsnano.0c08622 · Cited by 262
Aptamer Nanomedicine for Cancer Therapeutics: Barriers and Potential for Translation
Lao, Y.-H., Phua, K. K. L., & Leong, K. W. (2015) · ACS Nano · doi:10.1021/nn507494p · Cited by 259
Metadata
- Authors
- Lubin, A. A., & Plaxco, K. W.
- Venue
- Accounts of Chemical Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-03-04
- Volume
- 43
- Issue
- 4
- Pages
- 496-505
- ISSN
- 0001-4842 (ISSN-L)
- 1520-4898
- OpenAlex
- W2091826118
- Cited by
- 506
- References
- 65
- FWCI
- 15.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.