Assessment of Potential Stimuli for Mechano-Dependent Gating of MscL: Effects of Pressure, Tension, and Lipid Headgroups
Abstract
MscL is a mechanosensitive channel of large conductance that serves as an "emergency relief valve", protecting bacteria from acute hypoosmotic stress. Although it is well-accepted that the MscL protein and an adequate membrane matrix are necessary and sufficient for the function of this channel, the exact role of the membrane has yet to be elucidated. Here, we address the role of the membrane matrix through in vitro reconstitution of the MscL protein in defined lipid bilayers. We have applied Laplace's law to visualized membrane patches where we can measure patch curvature as described in previous studies. Here, by comparing patches with different curvatures, we demonstrate that the MscL channel senses tension within the membrane and that the pressure across it plays no detectable role as a stimulus. In addition, gating only occurs when the smallest radius of curvature is nearly achieved, suggesting that the lateral tension rather than membrane curvature is the important biophysical parameter. Finally, we have examined the contribution of specific headgroups by measuring their effect on the membrane tension required to gate the channel. We have found that the addition of neither anionic nor endogenous lipids to a non-native membrane effected a leftward shift in the activation curve. In fact, the major endogenous lipid of the Escherichia coli membrane, phosphatidylethanolamine, led to a channel activity at a higher tension threshold, suggesting that this lipid effects altered activity through changes in the biophysical properties of the membrane, rather than through an MscL-specific interaction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Emerging roles for lipids in shaping membrane-protein function
Phillips, R., Ursell, T., Wiggins, P., & Sens, P. (2009) · Nature · doi:10.1038/nature08147 · Cited by 984
Bilayer Thickness and Membrane Protein Function: An Energetic Perspective
Andersen, O. S., & Koeppe, R. E. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132643 · Cited by 866
Mechanically Activated Ion Channels
Ranade, S. S., Syeda, R., & Patapoutian, A. (2015) · Neuron · doi:10.1016/j.neuron.2015.08.032 · Cited by 652
Touch, Tension, and Transduction – The Function and Regulation of Piezo Ion Channels
Wu, J., Lewis, A. H., & Grandl, J. (2017) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2016.09.004 · Cited by 570
Cox, C. D., Bae, C., Ziegler, L., Hartley, S., Nikolova-Krstevski, V., Rohde, P. R., Ng, C.-A., Sachs, F., Gottlieb, P. A., & Martinac, B. (2016) · Nature Communications · doi:10.1038/ncomms10366 · Cited by 528
Responses of microorganisms to osmotic stress.
Bremer, E., & Krämer, R. (2019) · Annual Review of Microbiology · doi:10.1146/annurev-micro-020518-115504 · Cited by 463
Structure-based membrane dome mechanism for Piezo mechanosensitivity
Guo, Y. R., & MacKinnon, R. (2017) · eLife · doi:10.7554/elife.33660 · Cited by 446
Force-induced conformational changes in PIEZO1
Lin, Y.-C., Guo, Y. R., Miyagi, A., Levring, J., MacKinnon, R., & Scheuring, S. (2019) · Nature · doi:10.1038/s41586-019-1499-2 · Cited by 433
Mechanical sensitivity of Piezo1 ion channels can be tuned by cellular membrane tension
Lewis, A. H., & Grandl, J. (2015) · eLife · doi:10.7554/elife.12088 · Cited by 427
Mechanosensitivity is mediated directly by the lipid membrane in TRAAK and TREK1 K + channels
Brohawn, S. G., Su, Z., & MacKinnon, R. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1320768111 · Cited by 403
Mechanosensitive Channels: What Can They Do and How Do They Do It?
Haswell, E. S., Phillips, R., & Rees, D. C. (2011) · Structure · doi:10.1016/j.str.2011.09.005 · Cited by 378
Marsh, D. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.107938 · Cited by 367
Mechanosensitive Channels in Microbes
Kung, C., Martinac, B., & Sukharev, S. (2010) · Annual Review of Microbiology · doi:10.1146/annurev.micro.112408.134106 · Cited by 328
Protein modulation of lipids, and vice-versa, in membranes
Marsh, D. (2008) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2008.01.015 · Cited by 320
Xerocytosis is caused by mutations that alter the kinetics of the mechanosensitive channel PIEZO1
Bae, C., Gnanasambandam, R., Nicolai, C., Sachs, F., & Gottlieb, P. A. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1219777110 · Cited by 313
Stretch-Activated Ion Channels: What Are They?
Sachs, F. (2010) · Physiology · doi:10.1152/physiol.00042.2009 · Cited by 308
Feeling the hidden mechanical forces in lipid bilayer is an original sense
Anishkin, A., Loukin, S. H., Teng, J., & Kung, C. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1313364111 · Cited by 300
Davis, M. J., Earley, S., Li, Y.-S., & Chien, S. (2023) · Physiological Reviews · doi:10.1152/physrev.00053.2021 · Cited by 273
Magnetic nanomaterials for wireless thermal and mechanical neuromodulation
Signorelli, L., Hescham, S. A., Pralle, A., & Gregurec, D. (2022) · iScience · doi:10.1016/j.isci.2022.105401 · Cited by 32
Metadata
- Authors
- Moe, P., & Blount, P.
- Venue
- Biochemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-08-17
- Volume
- 44
- Issue
- 36
- Pages
- 12239-12244
- ISSN
- 0006-2960 (ISSN-L)
- 1520-4995
- OpenAlex
- W2060817925
- Cited by
- 201
- References
- 0
- FWCI
- 3.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.