Nitric Oxide-Producing Polyurethanes
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Thrombus formation and eventual intimal hyperplasia are the leading causes of small-diameter synthetic vascular graft failure. To combat these issues, we have incorporated a diazeniumdiolate-modified nitric oxide (NO)-producing peptide into a polyurethane to improve the thromboresistance of this biocompatible polymer. NO production by polyurethane films occurred for approximately 2 months under physiological conditions, and mechanical properties of the material were suitable for vascular graft applications. Platelet adhesion to NO-releasing polyurethane was dramatically decreased compared to control polyurethane. Furthermore, endothelial cell growth was stimulated in the presence of the NO-releasing polyurethane, while smooth muscle cell growth was greatly inhibited. The ability of this bioactive material to inhibit platelet adhesion and smooth muscle cell proliferation while encouraging endothelialization suggests that this NO-generating polyurethane may be suitable as a candidate material for small-diameter vascular grafts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maragos, C. M., Morley, D., Wink, D. A., Dunams, T. M., Saavedra, J. E., Hoffman, A., Bove, A. A., Isaac, L., Hrabie, J. A., & Keefer, L. K. (1991) · Journal of Medicinal Chemistry · doi:10.1021/jm00115a013 · Cited by 722
Mowery, K. A., H. Schoenfisch, M., Saavedra, J. E., Keefer, L. K., & Meyerhoff, M. E. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00127-1 · Cited by 219
Nitric Oxide-Releasing Polymers Containing the [N(O)NO]-Group
Smith, D. J., Chakravarthy, D., Pulfer, S., Simmons, M. L., Hrabie, J. A., Citro, M. L., Saavedra, J. E., Davies, K. M., Hutsell, T. C., Mooradian, D. L., et al. (1996) · Journal of Medicinal Chemistry · doi:10.1021/jm950652b · Cited by 208
Zhang, H., Annich, G. M., Miskulin, J., Osterholzer, K., Merz, S. I., Bartlett, R. H., & Meyerhoff, M. E. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00274-5 · Cited by 168
Improved haemocompatibility of cysteine-modified polymers via endogenous nitric oxide
Duan, X., & Lewis, R. S. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00234-4 · Cited by 75
Cited by
Biofunctionalization of Biomaterials for Accelerated in Situ Endothelialization: A Review
de Mel, A., Jell, G., Stevens, M. M., & Seifalian, A. M. (2008) · Biomacromolecules · doi:10.1021/bm800681k · Cited by 351
Development of Small‐Diameter Vascular Grafts
Wang, X., Lin, P., Yao, Q., & Chen, C. (2007) · World Journal of Surgery · doi:10.1007/s00268-006-0731-z · Cited by 206
“Thus, it suggests that this NO-generating polyurethane may be suitable as a candidate material for small-diameter vascular grafts.(36,37)”
Nitric Oxide Donors for Cardiovascular Implant Applications
Naghavi, N., de Mel, A., Alavijeh, O. S., Cousins, B. G., & Seifalian, A. M. (2013) · Small · doi:10.1002/smll.201200458 · Cited by 188
Kushwaha, M., Anderson, J. M., Bosworth, C. A., Andukuri, A., Minor, W. P., Lancaster, J. R., Anderson, P. G., Brott, B. C., & Jun, H.-W. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.10.051 · Cited by 187
“These results indicate that the PA-YK-NO nanofibrous matrix enhances endothelial cell growth but limits smooth muscle cell growth, which is consistent with earlier studies [18,19].”
BackgroundMethodResultSelf-citationA platform for nitric oxide delivery
Kim, J., Saravanakumar, G., Choi, H. W., Park, D., & Kim, W. J. (2014) · J. Mater. Chem. B · doi:10.1039/c3tb21259a · Cited by 166
Biohybrid nanosystems with polymer nanofibers and nanotubes
Greiner, A., Wendorff, J. H., Yarin, A. L., & Zussman, E. (2006) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-006-0356-z · Cited by 161
“Furthermore, coreshell nanofibers with the core fiber spun from water solutions containing enzymes have been used for controlled catalytic processes (Jia et al. 2002; Jun et al. 2005).”
BackgroundMethodNovel thromboresistant materials
Jordan, S. W., & Chaikof, E. L. (2007) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2007.02.048 · Cited by 153
Taite, L. J., Yang, P., Jun, H., & West, J. L. (2008) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30850 · Cited by 136
Self-citationRational design of biodegradable thermoplastic polyurethanes for tissue repair
Xu, C., & Hong, Y. (2022) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.11.029 · Cited by 109
“Many approaches have been used to reduce thrombogenicity and improve the intimal hyperplasia inhibition of biodegradable PUs based small diameter vascular grafts, such as surface/compositional modification with nonthrombogenic moieties [173–175], NO release [186, 187], drug release [229,230], and endothelialization [2…”
BackgroundMethodSeabra, A. B., Da Silva, R., De Souza, G. F. P., & De Oliveira, M. G. (2008) · Artificial Organs · doi:10.1111/j.1525-1594.2008.00540.x · Cited by 63
Harding, J. L., & Reynolds, M. M. (2014) · J. Mater. Chem. B · doi:10.1039/c3tb21458c · Cited by 43
Wang, C., Yang, F., Xu, Z., Shi, D., Chen, D., Dai, J., Gu, N., & Jiang, Q. (2013) · Thrombosis Research · doi:10.1016/j.thromres.2012.11.002 · Cited by 28
Preparation and characterization of diazeniumdiolate releasing ethylcellulose films
Wan, A., Gao, Q., & Li, H. (2009) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-008-3511-5 · Cited by 14
Metadata
- Authors
- Jun, H.-W., Taite, L. J., & West, J. L.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-01-19
- Volume
- 6
- Issue
- 2
- Pages
- 838-844
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2036886263
- Cited by
- 116
- References
- 5
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.