Cited by 694Catalysis and Hydrodesulfurization StudiesBiodiesel Production and ApplicationsCatalysis for Biomass Conversion

Heterogeneous catalytic deoxygenation of stearic acid for production of biodiesel

Snåre, Mathias, Kubičková, Iva, Mäki-Arvela, Päivi, Eränen, Kari, Murzin, Dmitry Yu.·2006·Industrial & Engineering Chemistry Research

Abstract

A novel method for production of diesel-like hydrocarbons via catalytic deoxygenation of fatty acid is discussed. The model compound stearic acid is deoxygenated to heptadecane, originating from the stearic acid alkyl chain. The deoxygenation reaction is carried out in a semibatch reactor under constant temperature and pressure, 300 °C and 6 bar, respectively. A thorough catalyst screening was performed to obtain the most promising metal and support combination. The catalysts were characterized by N 2 -physisorption, CO-chemisorption, and temperature-programmed desorption of hydrogen. A highly active and selective in the deoxygenation reaction of stearic acid carbon supported palladium catalyst converted stearic acid completely with >98% selectivity toward deoxygenated C17 products.

Integrity signals

Registry

Crossref · 10.1021/ie060334i

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Snåre et al. further investigated this catalytic reactivity, identifying a greater variety of catalysts that could be used for deoxygenation processes, including Pd/C.

    “Snåre et al. [130] further investigated this catalytic reactivity, identifying a greater variety of catalysts that could be used for deoxygenation processes, including Pd/C.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Snåre, M., Kubičková, I., Mäki-Arvela, P., Eränen, K., & Murzin, D. Y.
Affiliations
  • Åbo Akademi University (FI)
  • Laboratory of Industrial Chemistry, Process Chemistry Centre, Åbo Akademi University, Biskopsgatan 8, FIN-20500 Turku/Åbo, Finland
Corresponding author
Murzin, Dmitry Yu.
Venue
Industrial & Engineering Chemistry Research
Published
2006-06-28
Volume
45
Issue
16
Pages
5708-5715
ISSN
  • 0888-5885 (ISSN-L)
  • 1520-5045
OpenAlex
W2064811153
Cited by
694
References
12
Citations by year
2026: 23 · 2025: 26 · 2024: 41 · 2023: 39 · 2022: 33 · 2021: 41 · 2020: 38 · 2019: 50 · 2018: 51 · 2017: 46 · 2016: 55 · 2015: 46 · 2014: 36 · 2013: 54 · 2012: 38
FWCI
24.85
Type
journal article
Language
en
Open access
closed
Locations
  • Industrial & Engineering Chemistry Research (publishedVersion)
  • Åbo Akademi University Research Portal (submittedVersion)
Funders
Academy of Finland
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Catalysis and Hydrodesulfurization Studies
  • Physical Sciences › Engineering › Biomedical Engineering › Biodiesel Production and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Catalysis for Biomass Conversion
Keywords
catalytic deoxygenation, stearic acid, biodiesel, heptadecane, fatty acid conversion, palladium catalysts, heterogeneous catalysis, catalyst screening, semi-batch reactor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review