The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Solvent-Resistant Photocurable “Liquid Teflon” for Microfluidic Device Fabrication
Abstract
We report the first fabrication of a solvent-compatible microfluidic device based on photocurable "Liquid Teflon" materials. The materials are highly fluorinated functionalized perfluoropolyethers (PFPEs) that have liquidlike viscosities that can be cured into tough, highly durable elastomers that exhibit the remarkable chemical resistance of fluoropolymers such as Teflon. Poly(dimethylsiloxane) (PDMS) elastomers have rapidly become the material of choice for many recent microfluidic device applications. Despite the advantages of PDMS in relation to microfluidics technology, the material suffers from a serious drawback in that it swells in most organic solvents. The swelling of PDMS-based devices in organic solvents greatly disrupts the micrometer-sized features and makes it impossible for fluids to flow inside the channels. Our approach to this problem has been to replace PDMS with photocurable perfluoropolyethers. Device fabrication and valve actuation were accomplished using established procedures for PDMS devices. The additional advantage of photocuring allows fabrication time to be decreased from several hours to a matter of minutes. The PFPE-based device exhibited mechanical properties similar to those of Sylgard 184 before and after curing as well as remarkable resistance to organic solvents. This work has the potential to expand the field of microfluidics to many novel applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rubinstein, M., & Colby, R. H. (2003) · doi:10.1093/oso/9780198520597.001.0001 · Cited by 5,686
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Self-citationPoly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Self-citationSelf-Assembly of Highly Phosphorylated Silaffins and Their Function in Biosilica Morphogenesis
Kröger, N., Lorenz, S., Brunner, E., & Sumper, M. (2002) · Science · doi:10.1126/science.1076221 · Cited by 792
Chain Mobility in the Amorphous Region of Nylon 6 Observed under Active Uniaxial Deformation
Loo, L. S., Cohen, R. E., & Gleason, K. K. (2000) · Science · doi:10.1126/science.288.5463.116 · Cited by 229
Perfluoropolyether Synthesis in Liquid Carbon Dioxide by Hexafluoropropylene Photooxidation
Bunyard, W. C., Romack, T. J., & DeSimone, J. M. (1999) · Macromolecules · doi:10.1021/ma981588l · Cited by 28
Self-citation
Cited by
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Strategies in the design of nanoparticles for therapeutic applications
Petros, R. A., & DeSimone, J. M. (2010) · Nature Reviews Drug Discovery · doi:10.1038/nrd2591 · Cited by 3,651
Self-citationNew Approaches to Nanofabrication: Molding, Printing, and Other Techniques
Gates, B. D., Xu, Q., Stewart, M., Ryan, D., Willson, C. G., & Whitesides, G. M. (2005) · Chemical Reviews · doi:10.1021/cr030076o · Cited by 2,020
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Developing optofluidic technology through the fusion of microfluidics and optics
Psaltis, D., Quake, S. R., & Yang, C. (2006) · Nature · doi:10.1038/nature05060 · Cited by 1,733
Self-citationThe development of microgels/nanogels for drug delivery applications
Oh, J. K., Drumright, R., Siegwart, D. J., & Matyjaszewski, K. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.01.002 · Cited by 1,598
Dastjerdi, R., & Montazer, M. (2010) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2010.03.029 · Cited by 1,355
The past, present and potential for microfluidic reactor technology in chemical synthesis
Elvira, K. S., i Solvas, X. C., Wootton, R. C. R., & deMello, A. J. (2013) · Nature Chemistry · doi:10.1038/nchem.1753 · Cited by 1,203
PDMS absorption of small molecules and consequences in microfluidic applications
Toepke, M. W., & Beebe, D. J. (2006) · Lab on a Chip · doi:10.1039/b612140c · Cited by 1,190
Greener Approaches to Organic Synthesis Using Microreactor Technology
Mason, B. P., Price, K. E., Steinbacher, J. L., Bogdan, A. R., & McQuade, D. T. (2007) · Chemical Reviews · doi:10.1021/cr050944c · Cited by 985
Materials for Microfluidic Chip Fabrication
Ren, K., Zhou, J., & Wu, H. (2013) · Accounts of Chemical Research · doi:10.1021/ar300314s · Cited by 974
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Patterning surfaces with functional polymers
Nie, Z., & Kumacheva, E. (2008) · Nature Materials · doi:10.1038/nmat2109 · Cited by 935
Polymer microfabrication technologies for microfluidic systems
Becker, H., & Gärtner, C. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1692-2 · Cited by 860
Oh, K. W., & Ahn, C. H. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/5/r01 · Cited by 838
Biological implications of polydimethylsiloxane-based microfluidic cell culture
Regehr, K. J., Domenech, M., Koepsel, J. T., Carver, K. C., Ellison-Zelski, S. J., Murphy, W. L., Schuler, L. A., Alarid, E. T., & Beebe, D. J. (2009) · Lab on a Chip · doi:10.1039/b903043c · Cited by 719
Abgrall, P., & Gué, A.-M. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/5/r01 · Cited by 561
Multistep Synthesis of a Radiolabeled Imaging Probe Using Integrated Microfluidics
Lee, C.-C., Sui, G., Elizarov, A., Shu, C. J., Shin, Y.-S., Dooley, A. N., Huang, J., Daridon, A., Wyatt, P., Stout, D., et al. (2005) · Science · doi:10.1126/science.1118919 · Cited by 510
Self-citationDisposable Microfluidic Devices: Fabrication, Function, and Application
Fiorini, G. S., & Chiu, D. T. (2005) · BioTechniques · doi:10.2144/05383rv02 · Cited by 487
Membranes and microfluidics: a review
de Jong, J., Lammertink, R. G. H., & Wessling, M. (2006) · Lab on a Chip · doi:10.1039/b603275c · Cited by 483
Applications of microfluidics in chemical biology
Weibel, D. B., & Whitesides, G. M. (2006) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2006.10.016 · Cited by 443
Computerized microfluidic cell culture using elastomeric channels and Braille displays
Gu, W., Zhu, X., Futai, N., Cho, B. S., & Takayama, S. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0404353101 · Cited by 403
Control of polymeric nanoparticle size to improve therapeutic delivery
Hickey, J. W., Santos, J. L., Williford, J.-M., & Mao, H.-Q. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.10.006 · Cited by 379
Microfluidics for medical diagnostics and biosensors
Rivet, C., Lee, H., Hirsch, A., Hamilton, S., & Lu, H. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.08.015 · Cited by 356
Glass coating for PDMS microfluidic channels by sol–gel methods
Abate, A. R., Lee, D., Do, T., Holtze, C., & Weitz, D. A. (2008) · Lab on a Chip · doi:10.1039/b800001h · Cited by 318
Moragues, T., Arguijo, D., Beneyton, T., Modavi, C., Simutis, K., Abate, A. R., Baret, J.-C., deMello, A. J., Densmore, D., & Griffiths, A. D. (2023) · Nature Reviews Methods Primers · doi:10.1038/s43586-023-00212-3 · Cited by 316
High‐Resolution Soft Lithography: Enabling Materials for Nanotechnologies
Rolland, J. P., Hagberg, E. C., Denison, G. M., Carter, K. R., & De Simone, J. M. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200461122 · Cited by 292
Self-citationBartolo, D., Degré, G., Nghe, P., & Studer, V. (2008) · Lab Chip · doi:10.1039/b712368j · Cited by 265
Fluorinated Oligomers and Polymers in Photopolymerization
Vitale, A., Bongiovanni, R., & Ameduri, B. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00120 · Cited by 257
Rhee, M., Valencia, P. M., Rodriguez, M. I., Langer, R., Farokhzad, O. C., & Karnik, R. (2011) · Advanced Materials · doi:10.1002/adma.201004333 · Cited by 236
Future of the Particle Replication in Nonwetting Templates (PRINT) Technology
Xu, J., Wong, D. H. C., Byrne, J. D., Chen, K., Bowerman, C., & DeSimone, J. M. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201209145 · Cited by 208
Self-citationSurface Modification Techniques for Endothelial Cell Seeding in PDMS Microfluidic Devices
Akther, F., Yakob, S. B., Nguyen, N.-T., & Ta, H. T. (2020) · Biosensors · doi:10.3390/bios10110182 · Cited by 182
Simple, Expendable, 3D-Printed Microfluidic Systems for Sample Preparation of Petroleum
Kataoka, É. M., Murer, R. C., Santos, J. M., Carvalho, R. M., Eberlin, M. N., Augusto, F., Poppi, R. J., Gobbi, A. L., & Hantao, L. W. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04413 · Cited by 63
Metadata
- Authors
- Rolland, J. P., Van Dam, R. M., Schorzman, D. A., Quake, S. R., & DeSimone, J. M.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-02-06
- Volume
- 126
- Issue
- 8
- Pages
- 2322-2323
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1966062221
- Cited by
- 440
- References
- 7
- FWCI
- 16.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.