The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Cyanine-Based Fluorescent Probe for Highly Selective Detection of Glutathione in Cell Cultures and Live Mouse Tissues
Open accessAbstract
Glutathione (GSH) plays a crucial role in human pathologies. Near-infrared fluorescence-based sensors capable of detecting intracellular GSH in vivo would be useful tools to understand the mechanisms of diseases. In this work, two cyanine-based fluorescent probes, 1 and 2, containing sulfonamide groups were prepared. Evaluation of the fluorescence changes displayed by probe 1, which contains a 2,4-dinitrobenzenesulfonamide group, shows that it is cell-membrane-permeable and can selectively detect thiols such as GSH, cysteine (Cys), and homocysteine (Hcy) in living cells. The response of 1 to thiols can be reversed by treatment with N-methylmaleimide (NMM). Probe 2, which possesses a 5-(dimethylamino)naphthalenesulfonamide group, displays high selectivity for GSH over Cys and Hcy, and its response can be reversed using NMM. The potential biological utility of 2 was shown by its use in fluorescence imaging of GSH in living cells. Furthermore, probe 2 can determine changes in the intracellular levels of GSH modualated by H2O2. The properties of 2 enable its use in monitoring GSH in vivo in a mouse model. The results showed that intravenous injection of 2 into a mouse generates a dramatic image in which strong fluorescence is emitted from various tissues, including the liver, kidney, lung, and spleen. Importantly, 2 can be utilized to monitor the depletion of GSH in mouse tissue cells promoted by excessive administration of the painkiller acetaminophen. The combined results coming from this effort suggest that the new probe will serve as an efficient tool for detecting cellular GSH in animals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meister, A., & Anderson, M. E. (1983) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.52.070183.003431 · Cited by 5,680
Structure, mechanism and regulation of peroxiredoxins
Wood, Z. A., Schröder, E., Robin Harris, J., & Poole, L. B. (2003) · Trends in Biochemical Sciences · doi:10.1016/s0968-0004(02)00003-8 · Cited by 2,544
The importance of glutathione in human disease
Townsend, D. M., Tew, K. D., & Tapiero, H. (2003) · Biomedicine & Pharmacotherapy · doi:10.1016/s0753-3322(03)00043-x · Cited by 2,004
Yuan, L., Lin, W., Zheng, K., He, L., & Huang, W. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35313j · Cited by 1,822
Recent progress in the development of near-infrared fluorescent probes for bioimaging applications
Guo, Z., Park, S., Yoon, J., & Shin, I. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60271k · Cited by 1,801
Self-citationFluorescent and colorimetric probes for detection of thiols
Chen, X., Zhou, Y., Peng, X., & Yoon, J. (2010) · Chemical Society Reviews · doi:10.1039/b925092a · Cited by 1,580
Self-citationA Molecular Imaging Primer: Modalities, Imaging Agents, and Applications
James, M. L., & Gambhir, S. S. (2012) · Physiological Reviews · doi:10.1152/physrev.00049.2010 · Cited by 1,140
REGULATION OF GENE EXPRESSION BY REACTIVE OXYGEN
Dalton, T. P., Shertzer, H. G., & Puga, A. (1999) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev.pharmtox.39.1.67 · Cited by 1,118
Lead Phthalocyanine as a Selective Carrier for Preparation of a Cysteine-Selective Electrode
Shahrokhian, S. (2001) · Analytical Chemistry · doi:10.1021/ac010541m · Cited by 1,033
Near-infrared fluorescence: application to in vivo molecular imaging
Hilderbrand, S. A., & Weissleder, R. (2010) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2009.09.029 · Cited by 1,023
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Self-citationNiu, L.-Y., Guan, Y.-S., Chen, Y.-Z., Wu, L.-Z., Tung, C.-H., & Yang, Q.-Z. (2012) · Journal of the American Chemical Society · doi:10.1021/ja309079f · Cited by 901
Recent progress in luminescent and colorimetric chemosensors for detection of thiols
Jung, H. S., Chen, X., Kim, J. S., & Yoon, J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60024f · Cited by 882
Self-citationRecent progress in fluorescent and colorimetric chemosensors for detection ofamino acids
Zhou, Y., & Yoon, J. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15159b · Cited by 760
Self-citationBioinorganic Photochemistry: Frontiers and Mechanisms
Szaciłowski, K., Macyk, W., Drzewiecka-Matuszek, A., Brindell, M., & Stochel, G. (2005) · Chemical Reviews · doi:10.1021/cr030707e · Cited by 725
Glutathione deficiency is associated with impaired survival in HIV disease
Herzenberg, L. A., De Rosa, S. C., Dubs, J. G., Roederer, M., Anderson, M. T., Ela, S. W., Deresinski, S. C., & Herzenberg, L. A. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.5.1967 · Cited by 670
Yang, X., Guo, Y., & Strongin, R. M. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201103759 · Cited by 658
Fluorescent probes for sensing and imaging
Ueno, T., & Nagano, T. (2011) · Nature Methods · doi:10.1038/nmeth.1663 · Cited by 633
Thiol-addition reactions and their applications in thiol recognition
Yin, C., Huo, F., Zhang, J., Martínez-Máñez, R., Yang, Y., Lv, H., & Li, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60055f · Cited by 554
Zhang, M., Yu, M., Li, F., Zhu, M., Li, M., Gao, Y., Li, L., Liu, Z., Zhang, J., Zhang, D., et al. (2007) · Journal of the American Chemical Society · doi:10.1021/ja073140i · Cited by 502
Pittet, M. J., & Weissleder, R. (2011) · Cell · doi:10.1016/j.cell.2011.11.004 · Cited by 466
Guo, Z., Nam, S., Park, S., & Yoon, J. (2012) · Chemical Science · doi:10.1039/c2sc20540h · Cited by 431
Self-citationSaito, C., Zwingmann, C., & Jaeschke, H. (2010) · Hepatology · doi:10.1002/hep.23267 · Cited by 430
Homocysteine and vitamins in cardiovascular disease
Jacobsen, D. W. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.8.1833 · Cited by 418
Tang, B., Xing, Y., Li, P., Zhang, N., Yu, F., & Yang, G. (2007) · Journal of the American Chemical Society · doi:10.1021/ja072572q · Cited by 413
Lee, M. H., Han, J. H., Kwon, P.-S., Bhuniya, S., Kim, J. Y., Sessler, J. L., Kang, C., & Kim, J. S. (2012) · Journal of the American Chemical Society · doi:10.1021/ja210065g · Cited by 408
Hyman, L. M., & Franz, K. J. (2012) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2012.03.009 · Cited by 325
A Two-Photon Fluorescent Probe for Thiols in Live Cells and Tissues
Lee, J. H., Lim, C. S., Tian, Y. S., Han, J. H., & Cho, B. R. (2010) · Journal of the American Chemical Society · doi:10.1021/ja9090676 · Cited by 314
Van de Bittner, G. C., Bertozzi, C. R., & Chang, C. J. (2013) · Journal of the American Chemical Society · doi:10.1021/ja309078t · Cited by 292
Myochin, T., Kiyose, K., Hanaoka, K., Kojima, H., Terai, T., & Nagano, T. (2011) · Journal of the American Chemical Society · doi:10.1021/ja1063058 · Cited by 284
Sreejith, S., Divya, K. P., & Ajayaghosh, A. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200803194 · Cited by 269
Shao, N., Jin, J., Wang, H., Zheng, J., Yang, R., Chan, W., & Abliz, Z. (2010) · Journal of the American Chemical Society · doi:10.1021/ja908215t · Cited by 268
Shao, J., Sun, H., Guo, H., Ji, S., Zhao, J., Wu, W., Yuan, X., Zhang, C., & James, T. D. (2012) · Chem. Sci. · doi:10.1039/c2sc00762b · Cited by 265
A Fluorophore Capable of Crossword Puzzles and Logic Memory
Guo, Z., Zhu, W., Shen, L., & Tian, H. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200700526 · Cited by 260
Sreejith, S., Divya, K. P., & Ajayaghosh, A. (2008) · Angewandte Chemie · doi:10.1002/ange.200803194 · Cited by 256
Ratiometric optical oxygen sensing: a review in respect of material design
Feng, Y., Cheng, J., Zhou, L., Zhou, X., & Xiang, H. (2012) · The Analyst · doi:10.1039/c2an35907c · Cited by 233
A near-infrared reversible fluorescent probe for real-time imaging of redox status changes in vivo
Xu, K., Qiang, M., Gao, W., Su, R., Li, N., Gao, Y., Xie, Y., Kong, F., & Tang, B. (2013) · Chemical Science · doi:10.1039/c2sc22076h · Cited by 201
Guy, J., Caron, K., Dufresne, S., Michnick, S. W., Skene, & Keillor, J. W. (2007) · Journal of the American Chemical Society · doi:10.1021/ja0738125 · Cited by 179
Spectroscopy of Biological Molecules: Modern Trends
(1997) · Springer eBooks · doi:10.1007/978-94-011-5622-6 · Cited by 136
Maity, D., & Govindaraju, T. (2012) · Organic & Biomolecular Chemistry · doi:10.1039/c2ob27138a · Cited by 87
A Fast Response Highly Selective Probe for the Detection of Glutathione in Human Blood Plasma
Guo, Y., Yang, X., Hakuna, L., Barve, A., Escobedo, J. O., Lowry, M., & Strongin, R. M. (2012) · Sensors · doi:10.3390/s120505940 · Cited by 84
Chang, P. V., & Bertozzi, C. R. (2012) · Chemical Communications · doi:10.1039/c2cc31845h · Cited by 84
Mitchell, D. B., Acosta, D., & Bruckner, J. V. (1985) · Toxicology · doi:10.1016/0300-483x(85)90119-2 · Cited by 52
Hilderbrand, S. A., & Lippard, S. J. (2004) · Inorganic Chemistry · doi:10.1021/ic049649l · Cited by 46
Fu, N., Su, D. G. T., Cort, J., Chen, B., Xiong, Y., Qian, W., Konopka, A. E., Bigelow, D. J., & Squier, T. C. (2013) · Journal of the American Chemical Society · doi:10.1021/ja3117284 · Cited by 28
Biswal, B., & Bag, B. (2013) · Organic & Biomolecular Chemistry · doi:10.1039/c3ob40648b · Cited by 25
Cited by
Anti-quenching NIR-II molecular fluorophores for in vivo high-contrast imaging and pH sensing
Wang, S., Fan, Y., Li, D., Sun, C., Lei, Z., Lu, L., Wang, T., & Zhang, F. (2019) · Nature Communications · doi:10.1038/s41467-019-09043-x · Cited by 510
Umezawa, K., Yoshida, M., Kamiya, M., Yamasoba, T., & Urano, Y. (2017) · Nature Chemistry · doi:10.1038/nchem.2648 · Cited by 508
Chemically diverse small molecule fluorescent chemosensors for copper ion
Sivaraman, G., Iniya, M., Anand, T., Kotla, N. G., Sunnapu, O., Singaravadivel, S., Gulyani, A., & Chellappa, D. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.11.020 · Cited by 391
Near-infrared (NIR) fluorescence-emitting small organic molecules for cancer imaging and therapy
Li, H., Kim, Y., Jung, H., Hyun, J. Y., & Shin, I. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00722c · Cited by 356
A Reversible Fluorescent Probe for Real‐Time Quantitative Monitoring of Cellular Glutathione
Liu, Z., Zhou, X., Miao, Y., Hu, Y., Kwon, N., Wu, X., & Yoon, J. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201702114 · Cited by 312
Self-citation
Metadata
- Authors
- Yin, J., Kwon, Y., Kim, D., Lee, D., Kim, G., Hu, Y., Ryu, J.-H., & Yoon, J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-04-01
- Volume
- 136
- Issue
- 14
- Pages
- 5351-5358
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2069079930
- Cited by
- 599
- References
- 46
- FWCI
- 28.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.