The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Formation of Droplets and Mixing in Multiphase Microfluidics at Low Values of the Reynolds and the Capillary Numbers
Abstract
This paper reports an experimental characterization of a simple method for rapid formation of droplets, or plugs, of multiple aqueous reagents without bringing reagents into contact prior to mixing. Droplet-based microfluidics offers a simple method of achieving rapid mixing and transport with no dispersion. In addition, this paper shows that organic dyes at high concentrations should not be used for the visualization of flow patterns and mixing of aqueous plugs in multiphase flows in this system (fluorinated carrier fluid and PDMS microchannels). It reports an inorganic dye that can be used instead. This work focuses on mixing in plugs moving through straight channels. It demonstrates that, when traveling through straight microchannels, mixing within plugs by steady recirculating flow is highly sensitive to the initial distribution of the aqueous reagents established by the eddy flow at the tip of the forming plug (twirling). The results also show how plugs with proper distribution of the aqueous reagents could be formed in order to achieve optimal mixing of the reagents in this system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Dynamic Pattern Formation in a Vesicle-Generating Microfluidic Device
Thorsen, T., Roberts, R. W., Arnold, F. H., & Quake, S. R. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4163 · Cited by 2,051
Integrated Genomic and Proteomic Analyses of a Systematically Perturbed Metabolic Network
Ideker, T., Thorsson, V., Ranish, J. A., Christmas, R., Buhler, J., Eng, J. K., Bumgarner, R., Goodlett, D. R., Aebersold, R., & Hood, L. (2001) · Science · doi:10.1126/science.292.5518.929 · Cited by 2,050
A Group-IV Ferromagnetic Semiconductor: Mn x Ge 1− x
Park, Y. D., Hanbicki, A. T., Erwin, S. C., Hellberg, C. S., Sullivan, J. M., Mattson, J. E., Ambrose, T. F., Wilson, A., Spanos, G., & Jonker, B. T. (2002) · Science · doi:10.1126/science.1066348 · Cited by 1,631
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
Hydrodynamic Focusing on a Silicon Chip: Mixing Nanoliters in Microseconds
Knight, J. B., Vishwanath, A., Brody, J. P., & Austin, R. H. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.3863 · Cited by 887
Vital Involvement of a Natural Killer Cell Activation Receptor in Resistance to Viral Infection
Brown, M. G., Dokun, A. O., Heusel, J. W., Smith, H. R. C., Beckman, D. L., Blattenberger, E. A., Dubbelde, C. E., Stone, L. R., Scalzo, A. A., & Yokoyama, W. M. (2001) · Science · doi:10.1126/science.1060042 · Cited by 627
Ismagilov, R. F., Stroock, A. D., Kenis, P. J. A., Whitesides, G., & Stone, H. A. (2000) · Applied Physics Letters · doi:10.1063/1.126351 · Cited by 540
Self-citationMicrofabricated Multiphase Packed-Bed Reactors: Characterization of Mass Transfer and Reactions
Losey, M. W., Schmidt, M. A., & Jensen, K. F. (2001) · Industrial & Engineering Chemistry Research · doi:10.1021/ie000523f · Cited by 446
Phosphorylation and Activation of 13 S Condensin by Cdc2 in Vitro
Kimura, K., Hirano, M., Kobayashi, R., & Hirano, T. (1998) · Science · doi:10.1126/science.282.5388.487 · Cited by 378
Vesicles and Polymerized Vesicles from Thiophene‐Containing Rod–Coil Block Copolymers
Vriezema, D. M., Hoogboom, J., Velonia, K., Takazawa, K., Christianen, P. C. M., Maan, J. C., Rowan, A. E., & Nolte, R. J. M. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390204 · Cited by 334
Surface tension by pendant drop
Hansen, F., & Rødsrud, G. (1991) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(91)90296-k · Cited by 284
Fields, S. (2001) · Science · doi:10.1126/science.291.5507.1221 · Cited by 262
Efficient Mixing and Reactions within Microfluidic Channels Using Microbead-Supported Catalysts
Seong, G. H., & Crooks, R. M. (2002) · Journal of the American Chemical Society · doi:10.1021/ja020932y · Cited by 193
Mathematical modeling of drop mixing in a slit-type microchannel
Handique, K., & Burns, M. A. (2001) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/11/5/316 · Cited by 116
Rise of Liquids and Bubbles in Angular Capillary Tubes
Bico, J., & Quéré, D. (2002) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2001.8106 · Cited by 116
Putting the Brakes on Regeneration
McKerracher, L. J., & Ellezam, B. (2002) · Science · doi:10.1126/science.1073590 · Cited by 9
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Formation of droplets and bubbles in a microfluidic T-junction—scaling and mechanism of break-up
Garstecki, P., Fuerstman, M. J., Stone, H. A., & Whitesides, G. M. (2006) · Lab on a Chip · doi:10.1039/b510841a · Cited by 2,339
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Self-citationMicrofluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Control and detection of chemical reactions in microfluidic systems
deMello, A. J. (2006) · Nature · doi:10.1038/nature05062 · Cited by 1,495
Metadata
- Authors
- Tice, J. D., Song, H., Lyon, A. D., & Ismagilov, R. F.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-08-12
- Volume
- 19
- Issue
- 22
- Pages
- 9127-9133
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W1975330940
- Cited by
- 722
- References
- 20
- FWCI
- 19.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.