Abstract
This paper provides a synthesis of current knowledge about the associations of ventilation system types in office buildings with sick building syndrome (SBS) symptoms and discusses potential explanations for the associations. Most studies completed to date indicate that relative to natural ventilation, air conditioning, with or without humidification, was consistently associated with a statistically significant increase in the prevalence of one or more SBS symptoms, by approximately 30 to 200%. In two of three analyses from a single study (assessments), symptom prevalences were also significantly higher in air-conditioned buildings than in buildings with simple mechanical ventilation and no humidification. The available data also suggest, with less consistency, an increase in risk of symptoms with simple mechanical ventilation relative to natural ventilation. Insufficient information was available for conclusions about the potential increased risk of SBS symptoms with humidification or recirculation of return air. The statistically significant associations of mechanical ventilation and air conditioning with SBS symptoms are much more frequent than expected from chance and also not likely to be a consequence of confounding by several potential personal, job, or building-related confounders. Multiple deficiencies in HVAC system design, construction, operation, or maintenance, including some which cause pollutant emissions from HVAC systems, may contribute to the increases in symptom prevalences but other possible reasons remain unclear.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, J., & Yu, K. F. (1998) · JAMA · doi:10.1001/jama.280.19.1690 · Cited by 4,138
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876 · cited 2×
“Ventilation rates, which are associated with symptom prevalences (Seppanen et al. 1999), may have varied between types of HVAC systems and confounded results, but the ventilation rate was only measured in a few studies.”
BackgroundResultSelf-citationImpact of Temperature and Humidity on the Perception of Indoor Air Quality
Fang, L., Clausen, G., & Fanger, P. O. (1998) · Indoor Air · doi:10.1111/j.1600-0668.1998.t01-2-00003.x · Cited by 534
SICK BUILDING SYNDROME: A STUDY OF 4373 OFFICE WORKERS
(1987) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/31.4a.493 · Cited by 416
The sick building syndrome: prevalence studies.
Finnegan, M. J., Pickering, C. A., & Burge, P. S. (1984) · BMJ · doi:10.1136/bmj.289.6458.1573 · Cited by 373
Non-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic Literature
Mendell, M. J. (1993) · Indoor Air · doi:10.1111/j.1600-0668.1993.00003.x · Cited by 284
Treptow, W. (1927) · Angewandte Chemie · doi:10.1002/ange.19270400214 · Cited by 258
Mendell, M. J., & Smith, A. H. (1990) · American Journal of Public Health · doi:10.2105/ajph.80.10.1193 · Cited by 258
Proceedings of Healthy Buildings
Brohus, H. (2006) · Cited by 249
European Indoor Air Quality Audit Project in 56 Office Buildings
Bluyssen, P. M., Oliveira Fernandes, E., Groes, L., Clausen, G., Fanger, P. O., Valbjorn, O., Bernhard, C. A., & Roulet, C. A. (1996) · Indoor Air · doi:10.1111/j.1600-0668.1996.00002.x · Cited by 237
Cited by
Thermal comfort in naturally ventilated buildings: revisions to ASHRAE Standard 55
de Dear, R. J., & Brager, G. S. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00005-1 · Cited by 1,438
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034
Mendell, M. J., Mirer, A. G., Cheung, K., Tong, M., & Douwes, J. (2011) · Environmental Health Perspectives · doi:10.1289/ehp.1002410 · Cited by 986
Occupant productivity and office indoor environment quality: A review of the literature
Al Horr, Y., Arif, M., Kaushik, A., Mazroei, A., Katafygiotou, M., & Elsarrag, E. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.06.001 · Cited by 843
Al horr, Y., Arif, M., Katafygiotou, M., Mazroei, A., Kaushik, A., & Elsarrag, E. (2016) · International Journal of Sustainable Built Environment · doi:10.1016/j.ijsbe.2016.03.006 · Cited by 817
Ventilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740
“In a large majority of comparison studies, SBS symptom prevalence rates are lower in naturally ventilated buildings than in mechanically ventilated, air-conditioned buildings, despite the limited evidence that particle and viable fungi concentrations are higher in naturally ventilated buildings (Seppänen and Fisk, 200…”
BackgroundSelf-citationProgress in thermal comfort research over the last twenty years
de Dear, R. J., Akimoto, T., Arens, E. A., Brager, G., Candido, C., Cheong, K. W. D., Li, B., Nishihara, N., Sekhar, S. C., Tanabe, S., et al. (2013) · Indoor Air · doi:10.1111/ina.12046 · Cited by 523
Healthy Places: Exploring the Evidence
Frumkin, H. (2003) · American Journal of Public Health · doi:10.2105/ajph.93.9.1451 · Cited by 504
Meadow, J. F., Altrichter, A. E., Kembel, S. W., Kline, J., Mhuireach, G., Moriyama, M., Northcutt, D., O'Connor, T. K., Womack, A. M., Brown, G. Z., et al. (2014) · Indoor Air · doi:10.1111/ina.12047 · Cited by 411
Influence of indoor environmental quality on human health and productivity - A review
Mujan, I., Anđelković, A. S., Munćan, V., Kljajić, M., & Ružić, D. (2019) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.01.307 · Cited by 405
(2005) · Choice Reviews Online · doi:10.5860/choice.42-4060 · Cited by 372
Wargocki, P., & Wyon, D. P. (2007) · HVAC&R Research · doi:10.1080/10789669.2007.10390951 · Cited by 364
Public health and economic impact of dampness and mold
Mudarri, D., & Fisk, W. J. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00474.x · Cited by 319
Self-citationProviding better thermal and air quality conditions in school classrooms would be cost-effective
Wargocki, P., & Wyon, D. P. (2013) · Building and Environment · doi:10.1016/j.buildenv.2012.10.007 · Cited by 309
Wolkoff, P., Azuma, K., & Carrer, P. (2021) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2021.113709 · Cited by 279
Brandl, H. (2011) · The Open Environmental & Biological Monitoring Journal · doi:10.2174/1875040001104010083 · Cited by 256
Association between ventilation rates in 390 Swedish homes and allergic symptoms in children
Bornehag, C. G., Sundell, J., Hagerhed-Engman, L., & Sigsgaard, T. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2005.00372.x · Cited by 199
Passive alternatives to mechanical air conditioning of building: A review
Samuel, D. G. L., Nagendra, S. M. S., & Maiya, M. P. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.04.016 · Cited by 184
Evolving opportunities for providing thermal comfort
Brager, G., Zhang, H., & Arens, E. (2015) · Building Research & Information · doi:10.1080/09613218.2015.993536 · Cited by 164
Some Quantitative Relations between Indoor Environmental Quality and Work Performance or Health
Seppänen, O. A., & Fisk, W. (2006) · HVAC&R Research · doi:10.1080/10789669.2006.10391446 · Cited by 53
Self-citationGallego, E., Roca, F. J., Perales, J. F., & Guardino, X. (2011) · Sick Building Syndrome · doi:10.1007/978-3-642-17919-8_16 · Cited by 9
Metadata
- Authors
- Seppänen, O., & Fisk, W. J.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2002-06
- Volume
- 12
- Issue
- 2
- Pages
- 98-112
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2118071847
- Cited by
- 277
- References
- 29
- FWCI
- 6.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.