Ventilation and health in non-industrial indoor environments: report from a European Multidisciplinary Scientific Consensus Meeting (EUROVEN): Ventilation and health in non-industrial indoor environments
Open accessThe DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
Abstract
Ventilation and health in non-industrial indoor environments: report from a European Multidisciplinary Scientific Consensus Meeting (EUROVEN) Introduction Ventilation is the process of exchanging indoor (polluted) air with outdoor (presumably fresh and clean) air.Its main purpose is to create optimal conditions for humans in indoor environments, taking into account their health, comfort, and productivity by providing air for breathing, for removing and diluting indoor pollutants, for adding or removing moisture, and for heating or cooling.Abstract Scientific literature on the effects of ventilation on health, comfort, and productivity in non-industrial indoor environments (offices, schools, homes, etc.) has been reviewed by a multidisciplinary group of European scientists, called EUROVEN, with expertise in medicine, epidemiology, toxicology, and engineering.The group reviewed 105 papers published in peer-reviewed scientific journals and judged 30 as conclusive, providing sufficient information on ventilation, health effects, data processing, and reporting, 14 as providing relevant background information on the issue, 43 as relevant but non-informative or inconclusive, and 18 as irrelevant for the issue discussed.Based on the data in papers judged conclusive, the group agreed that ventilation is strongly associated with comfort (perceived air quality) and health [Sick Building Syndrome (SBS) symptoms, inflammation, infections, asthma, allergy, short-term sick leave], and that an association between ventilation and productivity (performance of office work) is indicated.The group also concluded that increasing outdoor air supply rates in non-industrial environments improves perceived air quality; that outdoor air supply rates below 25 l/s per person increase the risk of SBS symptoms, increase short-term sick leave, and decrease productivity among occupants of office buildings; and that ventilation rates above 0.5 air changes per hour (h )1 ) in homes reduce infestation of house dust mites in Nordic countries.The group concluded additionally that the literature indicates that in buildings with airconditioning systems there may be an increased risk of SBS symptoms compared with naturally or mechanically ventilated buildings, and that improper maintenance, design, and functioning of air-conditioning systems contributes to increased prevalence of SBS symptoms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Constitution of the World Health Organization
(1982) · International Organization and Integration Annotated Basic Documents and Descriptive Directory of International Organization and Arrangements · doi:10.1163/9789004634121_013 · Cited by 797
WARGOCKI, P., WYON, D. P., SUNDELL, J., CLAUSEN, G., & FANGER, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 688
Self-citationEstimates of Improved Productivity and Health from Better Indoor Environments
Fisk, W. J., & Rosenfeld, A. H. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.t01-1-00002.x · Cited by 549
Wargocki, P., Wyon, D. P., Baik, Y. K., Clausen, G., & Fanger, P. O. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.t01-1-00003.x · Cited by 507
Self-citationSICK BUILDING SYNDROME: A STUDY OF 4373 OFFICE WORKERS
(1987) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/31.4a.493 · Cited by 416
The sick building syndrome: prevalence studies.
Finnegan, M. J., Pickering, C. A., & Burge, P. S. (1984) · BMJ · doi:10.1136/bmj.289.6458.1573 · Cited by 373
Fanger, P. O. (1988) · Energy and Buildings · doi:10.1016/0378-7788(88)90051-5 · Cited by 371
Self-citationMILTON, D. K., GLENCROSS, P. M., & WALTERS, M. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004212.x · Cited by 364
APTE, M. G., FISK, W. J., & DAISEY, J. M. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004246.x · Cited by 341
Asthmatic symptoms and volatile organic compounds, formaldehyde, and carbon dioxide in dwellings.
Norbäck, D., Björnsson, E., Janson, C., Widström, J., & Boman, G. (1995) · Occupational and Environmental Medicine · doi:10.1136/oem.52.6.388 · Cited by 331
Non-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic Literature
Mendell, M. J. (1993) · Indoor Air · doi:10.1111/j.1600-0668.1993.00003.x · Cited by 284
Indoor air quality and personal factors related to the sick building syndrome.
Norback, D., Michel, I., & Widstrom, J. (1990) · Scandinavian Journal of Work, Environment & Health · doi:10.5271/sjweh.1808 · Cited by 272
An Epidemic of Pneumococcal Disease in an Overcrowded, Inadequately Ventilated Jail
Hoge, C. W., Reichler, M. R., Dominguez, E. A., Bremer, J. C., Mastro, T. D., Hendricks, K. A., Musher, D. M., Elliott, J. A., Facklam, R. R., & Breiman, R. F. (1994) · New England Journal of Medicine · doi:10.1056/nejm199409083311004 · Cited by 271
Airborne Infection: Theoretical Limits of Protection Achievable by Building Ventilation
Nardell, E. A., Keegan, J., Cheney, S. A., & Etkind, S. C. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.2.302 · Cited by 261
Mendell, M. J., & Smith, A. H. (1990) · American Journal of Public Health · doi:10.2105/ajph.80.10.1193 · Cited by 258
European Indoor Air Quality Audit Project in 56 Office Buildings
Bluyssen, P. M., Oliveira Fernandes, E., Groes, L., Clausen, G., Fanger, P. O., Valbjorn, O., Bernhard, C. A., & Roulet, C. A. (1996) · Indoor Air · doi:10.1111/j.1600-0668.1996.00002.x · Cited by 237
Self-citationThe “sick” building syndrome in the office environment: The Danish town hall study
Skov, P., Valbjørn, O., & DISG (1987) · Environment International · doi:10.1016/0160-4120(87)90190-5 · Cited by 233
Skov, P., Valbjorn, O., & Pedersen, B. V. (1990) · Scandinavian Journal of Work, Environment & Health · doi:10.5271/sjweh.1772 · Cited by 214
Norback, D., Torgen, M., & Edling, C. (1990) · Occupational and Environmental Medicine · doi:10.1136/oem.47.11.733 · Cited by 202
Ventilation in Homes and Bronchial Obstruction in Young Children
oie, L., Nafstad, P., Botten, G., Magnus, P., & Jaakkola, J. J. K. (1999) · Epidemiology · doi:10.1097/00001648-199905000-00018 · Cited by 188
1989 ASHRAE handbook : Fundamentals
Refrigerating (1977) · Medical Entomology and Zoology · Cited by 170
Air pollution sources in offices and assembly halls, quantified by the olf unit
Fanger, P. O., Lauridsen, J., Bluyssen, P., & Clausen, G. (1988) · Energy and Buildings · doi:10.1016/0378-7788(88)90052-7 · Cited by 168
Self-citationMenzies, D., & Bourbeau, J. (1997) · New England Journal of Medicine · doi:10.1056/nejm199711203372107 · Cited by 167
Health and Indoor Climate Complaints of 7043 office Workers in 61 Buildings in the Netherlands
Zweers, T., Preller, L., Brunekreef, B., & Boleij, J. S. M. (1992) · Indoor Air · doi:10.1111/j.1600-0668.1992.00001.x · Cited by 159
Building-Associated Risk of Febrile Acute Respiratory Diseases in Army Trainees
Brundage, J. F. (1988) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1988.03720140028029 · Cited by 158
Air-conditioning and Mortality in Hot Weather
Rogot, E., Sorlie, P. D., & Backlund, E. (1992) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a116413 · Cited by 154
The Effect of Varying Levels of Outdoor-Air Supply on the Symptoms of Sick Building Syndrome
Menzies, R., Tamblyn, R. M., Farant, J.-P., Hanley, J. A., Nunes, F., & Tamblyn, R. T. (1993) · New England Journal of Medicine · doi:10.1056/nejm199303253281201 · Cited by 148
New Ventilation Systems at Select Schools in Sweden—Effects on Asthma and Exposure
Smedje, G., & Norbäck, D. (2000) · Archives of Environmental Health An International Journal · doi:10.1080/00039890009603380 · Cited by 143
Jaakkola, J. J. K., Heinoneon, O. P., & Seppänen, O. (1991) · Indoor Air · doi:10.1111/j.1600-0668.1991.02-12.x · Cited by 128
Self-citationWork-related illness in offices: A proposed model of the “sick building syndrome”
Hedge, A., Burge, P. S., Robertson, A. S., Wilson, S., & Harris-Bass, J. (1989) · Environment International · doi:10.1016/0160-4120(89)90020-2 · Cited by 125
Relationships Between Ventilation and Indoor Air Quality: A Review
Godish, T., & Spengler, J. D. (1996) · Indoor Air · doi:10.1111/j.1600-0668.1996.00010.x · Cited by 125
Subjective Indoor Air Quality in Schools in Relation to Exposure
Smedje, G., Norbäck, D., & Edling, C. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.00009.x · Cited by 120
Ventilation requirements in buildings—I. Control of occupancy odor and tobacco smoke odor
Cain, W. S., Leaderer, B. P., Isseroff, R., Berglund, L. G., Huey, R. J., Lipsitt, E. D., & Perlman, D. (1983) · Atmospheric Environment (1967) · doi:10.1016/0004-6981(83)90341-4 · Cited by 112
Robertson, A. S., Burge, P. S., Hedge, A., Sims, J., Gill, F. S., Finnegan, M., Pickering, C. A., & Dalton, G. (1985) · BMJ · doi:10.1136/bmj.291.6492.373 · Cited by 108
Warner, J. A., Frederick, J. M., Bryant, T. N., Weich, C., Raw, G. J., Hunter, C., Stephend, F. R., McIntyre, D. A., & Warner, J. O. (2000) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(00)90181-7 · Cited by 108
Stenberg, B., Eriksson, N., Höög, J., Sundell, J., & Wall, S. (1994) · International Journal of Epidemiology · doi:10.1093/ije/23.6.1190 · Cited by 102
Self-citationHaghighat, F., & Donnini, G. (1999) · Building and Environment · doi:10.1016/s0360-1323(98)00034-1 · Cited by 100
House‐dust mites and associated environmental conditions in Danish homes
Harving, H., Korsgaard, J., & Dahl, R. (1993) · Allergy · doi:10.1111/j.1398-9995.1993.tb00694.x · Cited by 100
Predicting sick building syndrome at the individual and aggregate levels
Hedge, A., Erickson, W., & Rubin, G. (1996) · Environment International · doi:10.1016/0160-4120(95)00099-2 · Cited by 94
Sick buildings and the experimental approach
Wyon, D. P. (1992) · Environmental Technology · doi:10.1080/09593339209385159 · Cited by 88
Ventilation in homes infested by house‐dust mites
Sundell, J., Wickman, M. C., Pershagen, G., & Nordvall, S. L. (1995) · Allergy · doi:10.1111/j.1398-9995.1995.tb05065.x · Cited by 83
Self-citationOutbreak of Japanese Encephalitis on the Island of Saipan, 1990
Paul, W. S., Moore, P. S., Karabatsos, N., et al. (1993) · The Journal of Infectious Diseases · doi:10.1093/infdis/167.5.1053 · Cited by 80
Harving, H., Korsgaard, J., & Dahl, R. (1994) · Allergy · doi:10.1111/j.1398-9995.1994.tb00789.x · Cited by 78
Report of an outbreak: nursing home architecture and influenza-A attack rates
Drinka, P. J., Krause, P., Schilling, M., Miller, B. A., Shult, P., & Gravenstein, S. (1996) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1996.tb01859.x · Cited by 77
Nordström, K., Norbäck, D., & Akselsson, R. (1995) · Occupational and Environmental Medicine · doi:10.1136/oem.52.3.170 · Cited by 77
Wålinder, R., Norbäck, D., Wieslander, G., Smedje, G., Erwall, C., & Venge, P. (1998) · International Archives of Occupational and Environmental Health · doi:10.1007/s004200050309 · Cited by 74
Phase 1 of the California Healthy Building Study: A Summary
Fisk, W. J., Mendell, M. J., Daisey, J. M., Faulkner, D. M., Hodgson, A. T., Nematollahi, M., & Macher, J. M. (1993) · Indoor Air · doi:10.1111/j.1600-0668.1993.00005.x · Cited by 74
Sundell, J., Lindvall, T., & Stenberg, B. (1994) · Environment International · doi:10.1016/0160-4120(94)90141-4 · Cited by 71
Self-citationKodama, A. M., & McGee, R. I. (1986) · Archives of Environmental Health An International Journal · doi:10.1080/00039896.1986.9936702 · Cited by 69
Ventilation rate in office buildings and sick building syndrome.
Jaakkola, J. J. K., & Miettinen, P. (1995) · Occupational and Environmental Medicine · doi:10.1136/oem.52.11.709 · Cited by 68
Elevated Symptom Prevalence Associated with Ventilation Type in Office Buildings
Mendell, M. J., Fisk, W. J., Deddens, J. A., Seavey, W., Smith, A. H., Smith, D. F., Hodgson, A. T., Daisey, J. M., & Goldman, L. R. (1996) · Epidemiology · doi:10.1097/00001648-199611000-00004 · Cited by 68
Korver, W. O. E. (2001) · Elsevier eBooks · doi:10.1016/b978-0-8155-1449-7.50011-6 · Cited by 68
Respiratory disease among military personnel in Saudi Arabia during Operation Desert Shield.
Richards, A. L., Hyams, K. C., Watts, D. M., Rozmajzl, P. J., Woody, J. N., & Merrell, B. R. (1993) · American Journal of Public Health · doi:10.2105/ajph.83.9.1326 · Cited by 67
Building-related asthma in Denver office workers.
Hoffman, R. E., Wood, R. C., & Kreiss, K. (1993) · American Journal of Public Health · doi:10.2105/ajph.83.1.89 · Cited by 65
Health symptoms and the work environment in four nonproblem United States office buildings
Nelson, N. A., Kaufman, J. D., Burt, J., & Karr, C. J. (1995) · Scandinavian Journal of Work Environment & Health · doi:10.5271/sjweh.8 · Cited by 63
Sieber, W. K., Stayner, L. T., Malkin, R., et al. (1996) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1996.10389435 · Cited by 59
Norbäck, D. (1995) · Indoor Air · doi:10.1111/j.1600-0668.1995.00003.x · Cited by 58
Effect of a New Ventilation System on Health and Well-Being of Office Workers
Menzies, D., Pasztor, J., Nunes, F., Leduc, J., & Chan, C.-H. (1997) · Archives of Environmental Health An International Journal · doi:10.1080/00039899709602212 · Cited by 57
Sundell, J., Lindvall, T., Stenberg, B., & Wall, S. (1994) · Indoor Air · doi:10.1111/j.1600-0668.1994.t01-2-00003.x · Cited by 56
Self-citationVentilation requirements for the control of body odor in spaces occupied by women
Berg-Munch, B., Clausen, G., & Fanger, P. O. (1986) · Environment International · doi:10.1016/0160-4120(86)90030-9 · Cited by 53
Self-citationNasal Mucosal Swelling in Relation to Low Air Exchange Rate in Schools
Wålinder, R., Norbäck, D., Wieslander, G., Smedje, G., & Erwall, C. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.t01-1-00005.x · Cited by 48
Effect of Renovating an Office Building on Occupants’ Comfort and Health
Pejtersen, J., Brohus, H., Hyldgaard, C. E., Nielsen, J. B., Valbjørn, O., Hauschildt, P., Kjærgaard, S. K., & Wolkoff, P. (2001) · Indoor Air · doi:10.1034/j.1600-0668.2001.011001010.x · Cited by 45
Asthma and the indoor environment: Assessment of the health implications of high indoor air humidity
Andersen, I., & Korsgaard, J. (1986) · Environment International · doi:10.1016/0160-4120(86)90022-x · Cited by 43
Air recirculation and sick building syndrome: a blinded crossover trial.
Jaakkola, J. J. K., Tuomaala, P., & Seppänen, O. (1994) · American Journal of Public Health · doi:10.2105/ajph.84.3.422 · Cited by 41
Self-citationThe Effect of Domestic Factors on Respiratory Symptoms and FEV1
Hosein, H. R., Corey, P., & ROBERTSON, J. M. D. (1989) · International Journal of Epidemiology · doi:10.1093/ije/18.2.390 · Cited by 38
Prevalence of irritative symptoms in a nonproblem air-conditioned office building
Muzi, G., Abbritti, G., Accattoli, M. P., & Dell’Omo, M. (1998) · International Archives of Occupational and Environmental Health · doi:10.1007/s004200050295 · Cited by 37
Wieslander, G., Norbäck, D., Wålinder, R., Erwall, C., & Venge, P. (1999) · International Archives of Occupational and Environmental Health · doi:10.1007/s004200050408 · Cited by 35
Jaakkola, J. J. K., Reinikainen, L. M., Heinonen, O. P., Majanen, A., & Seppänen, O. (1991) · Environment International · doi:10.1016/0160-4120(91)90025-l · Cited by 34
Self-citationIndividual and Occupational Correlates of the Sick Building Syndrome
Hedge, A., Erickson, W., & Rubin, G. (1995) · Indoor Air · doi:10.1111/j.1600-0668.1995.t01-3-00003.x · Cited by 32
Nordström, K., Norbäck, D., & Akselsson, R. (1995) · Indoor Environment · doi:10.1177/1420326x9500400105 · Cited by 31
Heat wave mortality in nursing homes
Marmor, M. F. (1978) · Environmental Research · doi:10.1016/0013-9351(78)90065-8 · Cited by 31
The effect of ventilation and air pollution on perceived indoor air quality in five town halls
Zweers, T., Skov, P., Valbjørn, O., & Mølhave, L. (1990) · Energy and Buildings · doi:10.1016/0378-7788(90)90038-k · Cited by 25
Health and comfort changes among tenants after retrofitting of their housing
Iversen, M., Bach, E., & Lundqvist, G. R. (1986) · Environment International · doi:10.1016/0160-4120(86)90026-7 · Cited by 25
Nasal Congestion in Relation to Low Air Exchange Rate in Schools: Evaluation by Acoustic Rhinometry
Walinder, R., Norback, D., Wieslander, G., Smedje, G., & Erwall, C. (1997) · Acta Oto-Laryngologica · doi:10.3109/00016489709113467 · Cited by 24
Gustafsson, D., Andersson, K., Fagerlund, I., & Kjellman, N. ‐. M. (1996) · Allergy · doi:10.1111/j.1398-9995.1996.tb00024.x · Cited by 24
Hill, B. A., Craft, B. F., & Burkart, J. A. (1992) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1992.10388030 · Cited by 20
Tamblyn, R. M. (1992) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(92)90132-7 · Cited by 17
Design, construction, and operation of healthy buildings : solutions to global and regional concerns
Moschandreas, D. J., & Buildings, H. (1998) · American Society of Heating, Refrigerating and Air-Conditioning Engineers eBooks · Cited by 13
Ventilation rate as a determinant of symptoms and perceived odors among workers in daycare centers
Ruotsalainen, R., Jaakkola, N., & Jaakkola, J. J. K. (1994) · Environment International · doi:10.1016/0160-4120(94)90305-0 · Cited by 13
Indoor infection in a modern building.
SHIGEMATSU, I., & Minowa, M. (1985) · PubMed · Cited by 9
Cited by
Housing and Health: Time Again for Public Health Action
Krieger, J., & Higgins, D. L. (2002) · American Journal of Public Health · doi:10.2105/ajph.92.5.758 · Cited by 1,550
Li, Y., Leung, G. M., Tang, J. W., Yang, X., Chao, C. Y. H., Lin, J. Z., Lu, J. W., Nielsen, P. V., Niu, J., Qian, H., et al. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00445.x · Cited by 1,055
Self-citationBornehag, C.-G., Sundell, J., Weschler, C. J., Sigsgaard, T., Lundgren, B., Hasselgren, M., & Hägerhed-Engman, L. (2004) · Environmental Health Perspectives · doi:10.1289/ehp.7187 · Cited by 851
Self-citationAl horr, Y., Arif, M., Katafygiotou, M., Mazroei, A., Kaushik, A., & Elsarrag, E. (2016) · International Journal of Sustainable Built Environment · doi:10.1016/j.ijsbe.2016.03.006 · Cited by 817
Ventilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740
Self-citation
Metadata
- Authors
- Wargocki, P., Sundell, J., Bischof, W., Brundrett, G., Fanger, P. O., Gyntelberg, F., Hanssen, S. O., Harrison, P., Pickering, A., Seppänen, O., & Wouters, P.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2002-06
- Volume
- 12
- Issue
- 2
- Pages
- 113-128
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W1976577765
- Cited by
- 418
- References
- 81
- FWCI
- 8.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.