CoChat

Blood Pressure Measurement: Retrospective and Prospective Views

Smulyan, H., Safar, M. E. · 2011 · American Journal of Hypertension
Cited by 102

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Measurement of the arterial blood pressure (BP) is a time-honored, vital piece of medical information whose accuracy is seldom questioned. This review identifies the unappreciated weakness of the early validation data that compared the cuff to intra-arterial BP's. Unfortunately, the inaccuracy of the auscultatory systolic (SBP) and diastolic (DBP) measurements are necessarily transmitted to the arithmetically calculated mean (MBP) and pulse pressures (PP). The errors in cuff SBP have limited recent efforts to measure central SBP noninvasively because of the need for cuff pressure calibration of the recorded peripheral pulses. Furthermore, cuff DBP's routinely overestimate intra-arterial values adding to the error in the calculation of central PP-a recognized cardiovascular risk predictor.Validation data for the newer automatic oscillometric SBP and DBP measurements are little better. Oscillometric devices, however, offer some improvement in their recognition of the MBP, a measurement made independently of the SBP and DBP. The algorithms used to identify the SBP and DBP by the oscillometric device manufacturers are proprietary and differ from one another. Thus, the accuracy of the commercial devices cannot be compared or standardized. A data base listing those devices that have been "validated" against the inaccurate auscultatory method is available, but many commercial devices are not listed.In addition to the SBP and DBP, there is increasing interest in the information contained within the arterial and aortic pulses. Values such as pulse augmentation and amplification ratios are independent of calibration requirements and add risk assessment information beyond that of the BP itself.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/ajh.2011.22

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 102

Metadata

Authors
Smulyan, H., & Safar, M. E.
Venue
American Journal of Hypertension
Published
2011-06-01
Volume
24
Issue
6
Pages
628-634
ISSN
  • 0895-7061 (ISSN-L)
  • 1941-7225
OpenAlex
W2333733804
Cited by
102
References
7
FWCI
6.77
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Blood Pressure Measurement: Retrospective and Prospective Views. https://app.cochat.ai/papers/10.1038/ajh.2011.22
The paper
Smulyan, H., & Safar, M. E. (2011). Blood Pressure Measurement: Retrospective and Prospective Views. American Journal of Hypertension. https://doi.org/10.1038/ajh.2011.22

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.