CoChat

Extracellular matrix-based intracortical microelectrodes: Toward a microfabricated neural interface based on natural materials

Open access
Shen, Wen, Karumbaiah, Lohitash, Liu, Xi, Saxena, Tarun, Chen, Shuodan, Patkar, Radhika, Bellamkonda, Ravi V., Allen, Mark G. · 2015 · Microsystems & Nanoengineering
Cited by 57

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Extracellular matrix (ECM)-based implantable neural electrodes (NEs) were achieved using a microfabrication strategy on natural-substrate-based organic materials. The ECM-based design minimized the introduction of non-natural products into the brain. Further, it rendered the implants sufficiently rigid for penetration into the target brain region and allowed them subsequently to soften to match the elastic modulus of brain tissue upon exposure to physiological conditions, thereby reducing inflammatory strain fields in the tissue. Preliminary studies suggested that ECM-NEs produce a reduced inflammatory response compared with inorganic rigid and flexible approaches. In vivo intracortical recordings from the rat motor cortex illustrate one mode of use for these ECM-NEs. Researchers have combined biocompatible collagen fibers with a gelatinous protein mixture for improved brain–prosthetic interfaces. Mark Allen from the University of Pennsylvania and co-workers from the Georgia Institute of Technology set out to solve the problems typically associated with clinical brain applications—such as a mismatch between the rigidness of the implant and brain tissue, which leads to strain and inflammation. The researchers developed new electrodes that are embedded in a collagen/gelatinous mixture and have sufficient rigidity to enter target brain tissue. After incorporation into the brain, the electrodes soften and produce desireable biomechanical characteristics under physiological conditions. In vivo experiments demonstrated that this strategy yields reduced long-term inflammatory responses than existing methods, representingone step toward the development of implantable devices with improved functionality and reduced strain on patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/micronano.2015.10

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

Metadata

Authors
Shen, W., Karumbaiah, L., Liu, X., Saxena, T., Chen, S., Patkar, R., Bellamkonda, R. V., & Allen, M. G.
Venue
Microsystems & Nanoengineering
Published
2015-06-29
Volume
1
Issue
1
ISSN
2055-7434 (ISSN-L)
OpenAlex
W2625219434
Cited by
57
References
12
FWCI
3.57
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.