Extracellular matrix-based intracortical microelectrodes: Toward a microfabricated neural interface based on natural materials
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Extracellular matrix (ECM)-based implantable neural electrodes (NEs) were achieved using a microfabrication strategy on natural-substrate-based organic materials. The ECM-based design minimized the introduction of non-natural products into the brain. Further, it rendered the implants sufficiently rigid for penetration into the target brain region and allowed them subsequently to soften to match the elastic modulus of brain tissue upon exposure to physiological conditions, thereby reducing inflammatory strain fields in the tissue. Preliminary studies suggested that ECM-NEs produce a reduced inflammatory response compared with inorganic rigid and flexible approaches. In vivo intracortical recordings from the rat motor cortex illustrate one mode of use for these ECM-NEs. Researchers have combined biocompatible collagen fibers with a gelatinous protein mixture for improved brain–prosthetic interfaces. Mark Allen from the University of Pennsylvania and co-workers from the Georgia Institute of Technology set out to solve the problems typically associated with clinical brain applications—such as a mismatch between the rigidness of the implant and brain tissue, which leads to strain and inflammation. The researchers developed new electrodes that are embedded in a collagen/gelatinous mixture and have sufficient rigidity to enter target brain tissue. After incorporation into the brain, the electrodes soften and produce desireable biomechanical characteristics under physiological conditions. In vivo experiments demonstrated that this strategy yields reduced long-term inflammatory responses than existing methods, representingone step toward the development of implantable devices with improved functionality and reduced strain on patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Hydrogels as extracellular matrix mimics for 3D cell culture
Tibbitt, M. W., & Anseth, K. S. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22361 · Cited by 2,727
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Cortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
McConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480
Self-citationProgress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
Subbaroyan, J., Martin, D. C., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/006 · Cited by 368
The elastic modulus of Matrigel™ as determined by atomic force microscopy
Soofi, S. S., Last, J. A., Liliensiek, S. J., Nealey, P. F., & Murphy, C. J. (2009) · Journal of Structural Biology · doi:10.1016/j.jsb.2009.05.005 · Cited by 309
Relationship between intracortical electrode design and chronic recording function
Karumbaiah, L., Saxena, T., Carlson, D., Patil, K., Patkar, R., Gaupp, E. A., Betancur, M., Stanley, G. B., Carin, L., & Bellamkonda, R. V. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.016 · Cited by 241
Self-citation
Cited by
A review on mechanical considerations for chronically-implanted neural probes
Lecomte, A., Descamps, E., & Bergaud, C. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8b4f · Cited by 205
“Besides enhancing mechanical mimetism, hydrogel systems may benefit from modifications to incorporate covalently-bound bioactive agents, that promote neuritic outgrowth and cell density around the probe [28, 30, 33].”
BackgroundNeurohybrid Memristive CMOS-Integrated Systems for Biosensors and Neuroprosthetics
Mikhaylov, A., Pimashkin, A., Pigareva, Y., Gerasimova, S., Gryaznov, E., Shchanikov, S., Zuev, A., Talanov, M., Lavrov, I., Demin, V., et al. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00358 · Cited by 185
“…damaged brain, such tools of network structure manipulation allow one to mimic brain areas, which are involved in reflex activity, pattern retrieval in multilayered unidirectional network (Brewer et al., 2013; Poli et al., 2017) for neural tissue recovery from brain injury (Shimba et al., 2019).”
BackgroundThe Future of Neuroimplantable Devices: A Materials Science and Regulatory Perspective
Obidin, N., Tasnim, F., & Dagdeviren, C. (2020) · Advanced Materials · doi:10.1002/adma.201901482 · Cited by 126
Flexible and highly biocompatible nanofiber-based electrodes for neural surface interfacing
Heo, D. N., Kim, H.-J., Lee, Y. J., Heo, M., Lee, S. J., Lee, D., Do, S. H., Lee, S. H., & Kwon, I. K. (2017) · ACS Nano · doi:10.1021/acsnano.6b08390 · Cited by 86
Thukral, A., Ershad, F., Enan, N., Rao, Z., & Yu, C. (2018) · IEEE Nanotechnology Magazine · doi:10.1109/mnano.2017.2781290 · Cited by 19
The Pursuit of Chronically Reliable Neural Interfaces: A Materials Perspective
Guo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00599 · Cited by 19
“(A) Macroporous nanowire electrode array with integrated tissue scaffold (Tian et al., 2012), and (B) ECM-based microelectrodes (Shen et al., 2015).”
Method
Metadata
- Authors
- Shen, W., Karumbaiah, L., Liu, X., Saxena, T., Chen, S., Patkar, R., Bellamkonda, R. V., & Allen, M. G.
- Venue
- Microsystems & Nanoengineering
- Published
- 2015-06-29
- Volume
- 1
- Issue
- 1
- ISSN
- 2055-7434 (ISSN-L)
- OpenAlex
- W2625219434
- Cited by
- 57
- References
- 12
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.