A subfemtotesla multichannel atomic magnetometer
The DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
The magnetic field is one of the most fundamental and ubiquitous physical observables, carrying information about all electromagnetic phenomena. For the past 30 years, superconducting quantum interference devices (SQUIDs) operating at 4 K have been unchallenged as ultrahigh-sensitivity magnetic field detectors, with a sensitivity reaching down to 1 fT Hz(-1/2) (1 fT = 10(-15) T). They have enabled, for example, mapping of the magnetic fields produced by the brain, and localization of the underlying electrical activity (magnetoencephalography). Atomic magnetometers, based on detection of Larmor spin precession of optically pumped atoms, have approached similar levels of sensitivity using large measurement volumes, but have much lower sensitivity in the more compact designs required for magnetic imaging applications. Higher sensitivity and spatial resolution combined with non-cryogenic operation of atomic magnetometers would enable new applications, including the possibility of mapping non-invasively the cortical modules in the brain. Here we describe a new spin-exchange relaxation-free (SERF) atomic magnetometer, and demonstrate magnetic field sensitivity of 0.54 fT Hz(-1/2) with a measurement volume of only 0.3 cm3. Theoretical analysis shows that fundamental sensitivity limits of this device are below 0.01 fT Hz(-1/2). We also demonstrate simple multichannel operation of the magnetometer, and localization of magnetic field sources with a resolution of 2 mm.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The emerging optically pumped magnetometer (OPM), which is based on the Zeeman effect and light-atom interactions, is one of the most sensitive magnetometers that can reach a sensitivity as high as the SQUID sensor (32–34) without the cryogenic operational condition.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [32]
In the citing paper
“After approximately 40 years, OPM technology has reached femtotesla sensitivity with the advantage to work at room temperature (RT) (271, 272)”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [271]
In the citing paper
“At present, the main contenders are optical atomic magnetometers.Two different types of these have been proposed for MEG [47,48] and MCG [49].”
From Biomagnetism using SQUIDs: status and perspectives (2006) · cites this paper as [48]
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Perception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Self-citationResonant nonlinear magneto-optical effects in atoms
Budker, D., Gawlik, W., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Weis, A. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.1153 · Cited by 809
Functional Organization of Primate Visual Cortex Revealed by High Resolution Optical Imaging
Ts'o, D. Y., Frostig, R. D., Lieke, E. E., & Grinvald, A. (1990) · Science · doi:10.1126/science.2165630 · Cited by 524
Zimmerman, J. E., Thiene, P., & Harding, J. T. (1970) · Journal of Applied Physics · doi:10.1063/1.1659074 · Cited by 394
SQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Sensitive magnetometry based on nonlinear magneto-optical rotation
Budker, D., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Zolotorev, M. (2000) · Physical Review A · doi:10.1103/physreva.62.043403 · Cited by 335
Phase-Sensitive Evidence ford-Wave Pairing Symmetry in Electron-Doped Cuprate Superconductors
Tsuei, C. C., & Kirtley, J. R. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.182 · Cited by 322
Liquid-State NMR and Scalar Couplings in Microtesla Magnetic Fields
McDermott, R., Trabesinger, A. H., Mück, M., Hahn, E. L., Pines, A., & Clarke, J. (2002) · Science · doi:10.1126/science.1069280 · Cited by 300
Effect of rapid spin exchange on the magnetic-resonance spectrum of alkali vapors
Happer, W., & Tam, A. C. (1977) · Physical Review A · doi:10.1103/physreva.16.1877 · Cited by 288
Nonlinear Magneto-optic Effects with Ultranarrow Widths
Budker, D., Yashchuk, V., & Zolotorev, M. (1998) · Physical Review Letters · doi:10.1103/physrevlett.81.5788 · Cited by 239
Application of superconducting quantum interference devices to nuclear magnetic resonance
Greenberg, Y. S. (1998) · Reviews of Modern Physics · doi:10.1103/revmodphys.70.175 · Cited by 214
Detection of very weak magnetic fields (10−9gauss) by 87Rb zero-field level crossing resonances
Dupont-Roc, J., Haroche, S., & Cohen-Tannoudji, C. (1969) · Physics Letters A · doi:10.1016/0375-9601(69)90480-0 · Cited by 182
Magnetic field fluctuations arising from thermal motion of electric charge in conductors
Varpula, T., & Poutanen, T. J. (1984) · Journal of Applied Physics · doi:10.1063/1.332990 · Cited by 160
Magnetoencephalography - a noninvasive brain imaging method with 1 ms time resolution
Gratta, C. D., Pizzella, V., Tecchio, F., & Romani, G. L. (2001) · Reports on Progress in Physics · doi:10.1088/0034-4885/64/12/204 · Cited by 141
Paleomagnetic Evidence of a Low-Temperature Origin of Carbonate in the Martian Meteorite ALH84001
Kirschvink, J. L., Maine, A., & Vali, H. (1997) · Science · doi:10.1126/science.275.5306.1629 · Cited by 124
Thermal noise in biomagnetic measurements
Nenonen, J., Montonen, J., & Katila, T. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147514 · Cited by 81
An all-optical, high-sensitivity magnetic gradiometer
Affolderbach, C., Stähler, M., Knappe, S. A., & Wynands, R. (2002) · Applied Physics B · doi:10.1007/s00340-002-0959-8 · Cited by 72
Practical SQUID instrument for nondestructive testing
Tralshawala, N., Claycomb, J. R., & Miller, J. H. (1997) · Applied Physics Letters · doi:10.1063/1.119974 · Cited by 43
Improved direct-coupled dc SQUID read-out electronics with automatic bias voltage tuning
Drung, D., Bechstein, S., Franke, K.-P., Scheiner, M., & Schurig, T. (2001) · IEEE Transactions on Applied Superconductivity · doi:10.1109/77.919485 · Cited by 43
Low-drift broadband directly coupled dc SQUID read-out electronics
Oukhanski, N., Stolz, R., Zakosarenko, V., & Meyer, H. ‐. (2002) · Physica C Superconductivity · doi:10.1016/s0921-4534(01)01160-1 · Cited by 34
LASER PUMPING IN THE SCHEME OF AN MX-MAGNETOMETER
Aleksandrov, E. B., Balabas, M. V., Vershovskii, A. K., Ivanov, A. E., Yakobson, N. N., Velichanskiǐ, V. L., & Senkov, N. V. (1995) · Optics and Spectroscopy · Cited by 33
Harry, G. M., Jin, I., Paik, H. J., Stevenson, T. R., & Wellstood, F. C. (2000) · Applied Physics Letters · doi:10.1063/1.126059 · Cited by 29
Harry, G. M., Jin, I., Paik, H. J., Stevenson, T. R., Wellstood, F. C., & Revtex, T. U. (2008) · Cited by 25
Superconducting Magnetic Gradiometers For Underwater Target Detection
Clem, T. R. (1998) · Naval Engineers Journal · doi:10.1111/j.1559-3584.1998.tb02393.x · Cited by 24
Kandori, A., Miyashita, T., & Tsukada, K. (2000) · Review of Scientific Instruments · doi:10.1063/1.1150603 · Cited by 19
Research works printed but not linked: 1
- Alexandrov, E. B., Balabas, M. V., Pasgalev, A. S., Vershovskii, A. K. & Yakobson, N. N. Double-resonance atomic magnetometers: From gas discharge to laser pumping. Laser Phys. 6, 244–251 (1996)
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Nanoscale magnetic sensing with an individual electronic spin in diamond
Maze, J. R., Stanwix, P. L., Hodges, J. S., Hong, S., Taylor, J. M., Cappellaro, P., Jiang, L., Dutt, M. V. G., Togan, E., Zibrov, A. S., et al. (2008) · Nature · doi:10.1038/nature07279 · Cited by 1,984
High-sensitivity diamond magnetometer with nanoscale resolution
Taylor, J. M., Cappellaro, P., Childress, L., Jiang, L., Budker, D., Hemmer, P. R., Yacoby, A., Walsworth, R., & Lukin, M. D. (2008) · Nature Physics · doi:10.1038/nphys1075 · Cited by 1,959
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
“Presently, the most sensitive atomic optical magnetometer is the spin-exchange-relaxation-free (SERF) magnetometer whose demonstrated sensitivity exceeds 10−15 T/ √ Hz, with projected fundamental limits below 10−17 T/ √ Hz [12].”
InfluentialSelf-citationQuantum metrology with nonclassical states of atomic ensembles
Pezzè, L., Smerzi, A., Oberthaler, M. K., Schmied, R., & Treutlein, P. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.035005 · Cited by 1,682
“Current optical magnetometers are approaching quantum noise limits (Kominis et al., 2003; Wasilewski et al., 2010).”
Background
Metadata
- Authors
- Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V.
- Affiliations
- Princeton University (US)
- University of Washington (US)
- Corresponding author
- Romalis, M. V.
- Venue
- Nature
- Published
- 2003-04
- Volume
- 422
- Issue
- 6932
- Pages
- 596-599
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W1963919378
- Cited by
- 1,631
- References
- 28
- Citations by year
- 2026: 122 · 2025: 167 · 2024: 141 · 2023: 148 · 2022: 132 · 2021: 112 · 2020: 88 · 2019: 80 · 2018: 68 · 2017: 55 · 2016: 62 · 2015: 53 · 2014: 42 · 2013: 44 · 2012: 40
- FWCI
- 17.25
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Funders
- David and Lucile Packard Foundation
- Princeton University
- National Institutes of Health
- Lawrence Berkeley National Laboratory
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- atomic magnetometer, magnetic localization, measurement volume, magnetoencephalography, optically pumped atoms
- MeSH terms
- Magnetics, Sensitivity and Specificity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.