A subfemtotesla multichannel atomic magnetometer
The DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
The magnetic field is one of the most fundamental and ubiquitous physical observables, carrying information about all electromagnetic phenomena. For the past 30 years, superconducting quantum interference devices (SQUIDs) operating at 4 K have been unchallenged as ultrahigh-sensitivity magnetic field detectors, with a sensitivity reaching down to 1 fT Hz(-1/2) (1 fT = 10(-15) T). They have enabled, for example, mapping of the magnetic fields produced by the brain, and localization of the underlying electrical activity (magnetoencephalography). Atomic magnetometers, based on detection of Larmor spin precession of optically pumped atoms, have approached similar levels of sensitivity using large measurement volumes, but have much lower sensitivity in the more compact designs required for magnetic imaging applications. Higher sensitivity and spatial resolution combined with non-cryogenic operation of atomic magnetometers would enable new applications, including the possibility of mapping non-invasively the cortical modules in the brain. Here we describe a new spin-exchange relaxation-free (SERF) atomic magnetometer, and demonstrate magnetic field sensitivity of 0.54 fT Hz(-1/2) with a measurement volume of only 0.3 cm3. Theoretical analysis shows that fundamental sensitivity limits of this device are below 0.01 fT Hz(-1/2). We also demonstrate simple multichannel operation of the magnetometer, and localization of magnetic field sources with a resolution of 2 mm.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The emerging optically pumped magnetometer (OPM), which is based on the Zeeman effect and light-atom interactions, is one of the most sensitive magnetometers that can reach a sensitivity as high as the SQUID sensor (32–34) without the cryogenic operational condition.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [32]
In the citing paper
“After approximately 40 years, OPM technology has reached femtotesla sensitivity with the advantage to work at room temperature (RT) (271, 272)”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [271]
In the citing paper
“At present, the main contenders are optical atomic magnetometers.Two different types of these have been proposed for MEG [47,48] and MCG [49].”
From Biomagnetism using SQUIDs: status and perspectives (2006) · cites this paper as [48]
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Perception's shadow: long-distance synchronization of human brain activity
Rodriguez, E., George, N., Lachaux, J.-P., Martinerie, J., Renault, B., & Varela, F. J. (1999) · Nature · doi:10.1038/17120 · Cited by 1,915
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Self-citationResonant nonlinear magneto-optical effects in atoms
Budker, D., Gawlik, W., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Weis, A. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.1153 · Cited by 809
Functional Organization of Primate Visual Cortex Revealed by High Resolution Optical Imaging
Ts'o, D. Y., Frostig, R. D., Lieke, E. E., & Grinvald, A. (1990) · Science · doi:10.1126/science.2165630 · Cited by 524
Zimmerman, J. E., Thiene, P., & Harding, J. T. (1970) · Journal of Applied Physics · doi:10.1063/1.1659074 · Cited by 394
SQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Sensitive magnetometry based on nonlinear magneto-optical rotation
Budker, D., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Zolotorev, M. (2000) · Physical Review A · doi:10.1103/physreva.62.043403 · Cited by 335
Phase-Sensitive Evidence ford-Wave Pairing Symmetry in Electron-Doped Cuprate Superconductors
Tsuei, C. C., & Kirtley, J. R. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.182 · Cited by 322
Liquid-State NMR and Scalar Couplings in Microtesla Magnetic Fields
McDermott, R., Trabesinger, A. H., Mück, M., Hahn, E. L., Pines, A., & Clarke, J. (2002) · Science · doi:10.1126/science.1069280 · Cited by 300
Research works printed but not linked: 1
- Alexandrov, E. B., Balabas, M. V., Pasgalev, A. S., Vershovskii, A. K. & Yakobson, N. N. Double-resonance atomic magnetometers: From gas discharge to laser pumping. Laser Phys. 6, 244–251 (1996)
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Nanoscale magnetic sensing with an individual electronic spin in diamond
Maze, J. R., Stanwix, P. L., Hodges, J. S., Hong, S., Taylor, J. M., Cappellaro, P., Jiang, L., Dutt, M. V. G., Togan, E., Zibrov, A. S., et al. (2008) · Nature · doi:10.1038/nature07279 · Cited by 1,984
High-sensitivity diamond magnetometer with nanoscale resolution
Taylor, J. M., Cappellaro, P., Childress, L., Jiang, L., Budker, D., Hemmer, P. R., Yacoby, A., Walsworth, R., & Lukin, M. D. (2008) · Nature Physics · doi:10.1038/nphys1075 · Cited by 1,959
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
“Presently, the most sensitive atomic optical magnetometer is the spin-exchange-relaxation-free (SERF) magnetometer whose demonstrated sensitivity exceeds 10−15 T/ √ Hz, with projected fundamental limits below 10−17 T/ √ Hz [12].”
InfluentialSelf-citationQuantum metrology with nonclassical states of atomic ensembles
Pezzè, L., Smerzi, A., Oberthaler, M. K., Schmied, R., & Treutlein, P. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.035005 · Cited by 1,682
“Current optical magnetometers are approaching quantum noise limits (Kominis et al., 2003; Wasilewski et al., 2010).”
BackgroundSearch for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560
“The measurement technique is based on the principles of spin-exchange-relaxation-free (SERF) magnetometry Allred et al. (2002); Kominis et al. (2003); Kornack et al. (2005); Kornack and Romalis (2002).”
MethodMoving magnetoencephalography towards real-world applications with a wearable system
Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., et al. (2018) · Nature · doi:10.1038/nature26147 · Cited by 1,377
Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Dang, H. B., Maloof, A. C., & Romalis, M. V. (2010) · Applied Physics Letters · doi:10.1063/1.3491215 · Cited by 891
Self-citationKitching, J. (2018) · Applied Physics Reviews · doi:10.1063/1.5026238 · Cited by 621
Nuclear Spin Gyroscope Based on an Atomic Comagnetometer
Kornack, T. W., Ghosh, R. K., & Romalis, M. V. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.230801 · Cited by 565
Self-citationApplications of the signal space separation method
Taulu, S., Simola, J., & Kajola, M. (2005) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2005.853302 · Cited by 548
“In principle, any direction in the signal space represents a valid result of a magnetic field measurement.”
BackgroundChip-scale atomic magnetometer
Schwindt, P. D. D., Knappe, S., Shah, V., Hollberg, L., Kitching, J., Liew, L.-A., & Moreland, J. (2004) · Applied Physics Letters · doi:10.1063/1.1839274 · Cited by 481
Quantum metrology and its application in biology
Taylor, M. A., & Bowen, W. P. (2016) · Physics Reports · doi:10.1016/j.physrep.2015.12.002 · Cited by 470
“With recent advances, atom based magnetometers can now provide the sensitivity of a SQUID while operating at room temperature [192, 193, 32].”
BackgroundElectric dipole moments of atoms, molecules, nuclei, and particles
Chupp, T. E., Fierlinger, P., Ramsey-Musolf, M. J., & Singh, J. T. (2019) · Reviews of Modern Physics · doi:10.1103/revmodphys.91.015001 · Cited by 450
“…as long as 60 s in alkene-coated cells (Balabas et al., 2010).9 Spin exchange between atoms is a fundamental limitation that has been suppressed by increasing the alkali-metal density or attaining very high polarization in spin-exchange relaxation-free or SERF magnetometers (Kominis et al., 2003).”
BackgroundMagnetoencephalography with an atomic magnetometer
Xia, H., Ben-Amar Baranga, A., Hoffman, D., & Romalis, M. V. (2006) · Applied Physics Letters · doi:10.1063/1.2392722 · Cited by 441
Self-citationQuantum-enhanced measurements without entanglement
Braun, D., Adesso, G., Benatti, F., Floreanini, R., Marzolino, U., Mitchell, M. W., & Pirandola, S. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.035006 · Cited by 434
“…interferometers at high power (Aasi et al., 2013; The LIGO Scientific Collaboration, 2011), high-density atomic magnetometers (Dang et al., 2010; Kominis et al., 2003; Shah et al., 2010; Vasilakis et al., 2011) and highdensity atomic clocks (Deutsch et al., 2010), the assumption of uncoupled…”
BackgroundSubpicotesla atomic magnetometry with a microfabricated vapour cell
Shah, V., Knappe, S., Schwindt, P. D. D., & Kitching, J. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.201 · Cited by 415
“For comparison, the sensitivity obtained under similar conditions using an orthogonal pump–probe configuratio”
MethodOptically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400
“This regime is often referred to as the spin exchange relaxation free(SERF) regime (Allred et al., 2002; Kominis et al., 2003).”
BackgroundSpin-exchange-relaxation-free magnetometry with Cs vapor
Ledbetter, M. P., Savukov, I. M., Acosta, V. M., Budker, D., & Romalis, M. V. (2008) · Physical Review A · doi:10.1103/physreva.77.033408 · Cited by 399
Self-citationPresentation of electromagnetic multichannel data: The signal space separation method
Taulu, S., & Kajola, M. (2005) · Journal of Applied Physics · doi:10.1063/1.1935742 · Cited by 390
Spin Hyperpolarization in Modern Magnetic Resonance
Eills, J., Budker, D., Cavagnero, S., Chekmenev, E. Y., Elliott, S. J., Jannin, S., Lesage, A., Matysik, J., Meersmann, T., Prisner, T., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00534 · Cited by 368
Subfemtotesla Scalar Atomic Magnetometry Using Multipass Cells
Sheng, D., Li, S., Dural, N., & Romalis, M. V. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.160802 · Cited by 364
Self-citationKitching, J., Knappe, S., & Donley, E. A. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2157679 · Cited by 330
“For example, atomic (optical) magnetometers with a sensitivity below 1 have recently been demonstrated [1], as have nuclear magnetic resonances (NMR) gyroscopes with an angle-random walk (ARW) below 0.”
BackgroundMagnetic Sensitivity Beyond the Projection Noise Limit by Spin Squeezing
Sewell, R. J., Koschorreck, M., Napolitano, M., Dubost, B., Behbood, N., & Mitchell, M. W. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.253605 · Cited by 323
A compact, high performance atomic magnetometer for biomedical applications
Shah, V. K., & Wakai, R. T. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/22/8153 · Cited by 322
“(Some figures may appear in colour only in the online journal)”
BackgroundUnshielded three-axis vector operation of a spin-exchange-relaxation-free atomic magnetometer
Seltzer, S. J., & Romalis, M. V. (2004) · Applied Physics Letters · doi:10.1063/1.1814434 · Cited by 320
Self-citationFemtotesla Magnetic Field Measurement with Magnetoresistive Sensors
Pannetier, M., Fermon, C., Le Goff, G., Simola, J., & Kerr, E. (2004) · Science · doi:10.1126/science.1096841 · Cited by 314
Tunable Atomic Magnetometer for Detection of Radio-Frequency Magnetic Fields
Savukov, I. M., Seltzer, S. J., Romalis, M. V., & Sauer, K. L. (2005) · Physical Review Letters · doi:10.1103/physrevlett.95.063004 · Cited by 313
Self-citationLow-temperature thermodynamics with quantum coherence
Narasimhachar, V., & Gour, G. (2015) · Nature Communications · doi:10.1038/ncomms8689 · Cited by 306
Sarracanie, M., LaPierre, C. D., Salameh, N., Waddington, D. E. J., Witzel, T., & Rosen, M. S. (2015) · Scientific Reports · doi:10.1038/srep15177 · Cited by 295
Magnetoencephalography: From SQUIDs to neuroscience
Hari, R., & Salmelin, R. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.074 · Cited by 285
“Atomic magnetometers (Kominis et al., 2003) have been used to detect auditory-evoked brain responses (Xia et al., 2006).”
Multi-Channel Whole-Head OPM-MEG: Helmet Design and a Comparison with a Conventional System
Hill, R. M., Boto, E., Rea, M., Holmes, N., Leggett, J., Coles, L. A., Papastavrou, M., Everton, S. K., Hunt, B. A. E., Sims, D., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116995 · Cited by 285
“OPMs have been shown to have sensitivities close to that of commercial SQUIDs (Allred et al., 2002; Dang et al., 2010; Kominis et al., 2003) and microfabrication techniques have enabled miniaturisation (Griffith et al., 2010; Schwindt et al., 2007; Shah et al., 2007; Shah and Romalis, 2009; Shah…”
BackgroundSpin-exchange relaxation-free magnetometry using elliptically polarized light
Shah, V., & Romalis, M. V. (2009) · Physical Review A · doi:10.1103/physreva.80.013416 · Cited by 273
Self-citationPolarized Alkali-Metal Vapor with Minute-Long Transverse Spin-Relaxation Time
Balabas, M. V., Karaulanov, T., Ledbetter, M. P., & Budker, D. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.070801 · Cited by 272
Magnetoresistive Sensor Development Roadmap (Non-Recording Applications)
Zheng, C., Zhu, K., Cardoso de Freitas, S., Chang, J.-Y., Davies, J. E., Eames, P., Freitas, P. P., Kazakova, O., Kim, C., Leung, C.-W., et al. (2019) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2896036 · Cited by 268
The future of ultra-high field MRI and fMRI for study of the human brain
Duyn, J. H. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.065 · Cited by 261
“Examples are diamond magnetometers to detect single spins (Balasubramanian et al., 2008; Maze et al., 2008), and alkali-metal magnetometers (Kominis et al., 2003).”
BackgroundPortable Magnetometry for Detection of Biomagnetism in Ambient Environments
Limes, M. E., Foley, E. L., Kornack, T. W., Caliga, S., McBride, S., Braun, A., Lee, W., Lucivero, V. G., & Romalis, M. V. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.14.011002 · Cited by 257
“Most sensitive atomic magnetometers operate using alkali vapors near zero field in a spin-exchange relaxation-free (SERF) regime [6].”
BackgroundSelf-citationA low-noise ferrite magnetic shield
Kornack, T. W., Smullin, S. J., Lee, S.-K., & Romalis, M. V. (2007) · Applied Physics Letters · doi:10.1063/1.2737357 · Cited by 247
Self-citationNMR Detection with an Atomic Magnetometer
Savukov, I. M., & Romalis, M. V. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.123001 · Cited by 250
Self-citationInteraction-based quantum metrology showing scaling beyond the Heisenberg limit
Napolitano, M., Koschorreck, M., Dubost, B., Behbood, N., Sewell, R. J., & Mitchell, M. W. (2011) · Nature · doi:10.1038/nature09778 · Cited by 245
High-Resolution Magnetometry with a Spinor Bose-Einstein Condensate
Vengalattore, M., Higbie, J. M., Leslie, S. R., Guzman, J., Sadler, L. E., & Stamper-Kurn, D. M. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.200801 · Cited by 246
Squeezed-Light Optical Magnetometry
Wolfgramm, F., Cerè, A., Beduini, F. A., Predojević, A., Koschorreck, M., & Mitchell, M. W. (2010) · Physical Review Letters · doi:10.1103/physrevlett.105.053601 · Cited by 238
Effects of spin-exchange collisions in a high-density alkali-metal vapor in low magnetic fields
Savukov, I. M., & Romalis, M. V. (2005) · Physical Review A · doi:10.1103/physreva.71.023405 · Cited by 232
Self-citationZalesskiy, S. S., Danieli, E., Blümich, B., & Ananikov, V. P. (2014) · Chemical Reviews · doi:10.1021/cr400063g · Cited by 232
Recording brain activities in unshielded Earth’s field with optically pumped atomic magnetometers
Zhang, R., Xiao, W., Ding, Y., Feng, Y., Peng, X., Shen, L., Sun, C., Wu, T., Wu, Y., Yang, Y., et al. (2020) · Science Advances · doi:10.1126/sciadv.aba8792 · Cited by 222
Magnetoencephalography with a two-color pump-probe, fiber-coupled atomic magnetometer
Johnson, C., Schwindt, P. D. D., & Weisend, M. (2010) · Applied Physics Letters · doi:10.1063/1.3522648 · Cited by 210
Toward Quantitative Bio-sensing with Nitrogen–Vacancy Center in Diamond
Zhang, T., Pramanik, G., Zhang, K., Gulka, M., Wang, L., Jing, J., Xu, F., Li, Z., Wei, Q., Cigler, P., et al. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00415 · Cited by 208
Online and offline tools for head movement compensation in MEG
Stolk, A., Todorovic, A., Schoffelen, J.-M., & Oostenveld, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.11.047 · Cited by 209
“Future advances with optically pumped magnetometers (Kominis et al., 2003; Sander et al., 2012) may result in a cap-style MEG sensor array that can move along with the head.”
Single-Spin Magnetometry with Multipulse Sensing Sequences
de Lange, G., Ristè, D., Dobrovitski, V. V., & Hanson, R. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.080802 · Cited by 209
Biosensing Using Magnetic Particle Detection Techniques
Chen, Y.-T., Kolhatkar, A. G., Zenasni, O., Xu, S., & Lee, T. R. (2017) · Sensors · doi:10.3390/s17102300 · Cited by 206
“01 ft/Hz1/2 for a spin-exchange relaxation-free magnetometer [227].”
Fano resonances and all-optical switching in a resonantly coupled plasmonic–atomic system
Stern, L., Grajower, M., & Levy, U. (2014) · Nature Communications · doi:10.1038/ncomms5865 · Cited by 196
On the Potential of a New Generation of Magnetometers for MEG: A Beamformer Simulation Study
Boto, E., Bowtell, R., Krüger, P., Fromhold, T. M., Morris, P. G., Meyer, S. S., Barnes, G. R., & Brookes, M. J. (2016) · PLOS ONE · doi:10.1371/journal.pone.0157655 · Cited by 194
“demonstrated [34, 35]; working in the spin-exchange relaxation-free (SERF) regime [36, 37].”
BackgroundPetrosyan, D., & Malakyan, Y. P. (2004) · Physical Review A · doi:10.1103/physreva.70.023822 · Cited by 190
Femtotesla atomic magnetometry in a microfabricated vapor cell
Griffith, W. C., Knappe, S., & Kitching, J. (2010) · Optics Express · doi:10.1364/oe.18.027167 · Cited by 183
Advances in Atomic Gyroscopes: A View from Inertial Navigation Applications
Fang, J., & Qin, J. (2012) · Sensors · doi:10.3390/s120506331 · Cited by 183
“The demonstrated ASG based on comagnetometer used alkali metal atoms which are in the SpinExchange Relaxation Free (SERF) regime [78,79] to increase the fundamental sensitivity of rotation.”
MethodA 20-channel magnetoencephalography system based on optically pumped magnetometers
Borna, A., Carter, T. R., Goldberg, J. D., Colombo, A. P., Jau, Y.-Y., Berry, C., McKay, J., Stephen, J., Weisend, M., & Schwindt, P. D. D. (2017) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa93d1 · Cited by 173
“er beams travel collinearly through the sensor. The scheme is an extension of an OPM using elliptically polarized light [12], and operates in the so-called spin-exchange relaxation-free (SERF) regime [22]. In the SERF regime, the OPM is operated at a high density of the rubidium vapor and near zero magnetic field— und…”
Biomagnetism using SQUIDs: status and perspectives
Sternickel, K., & Braginski, A. I. (2006) · Superconductor Science and Technology · doi:10.1088/0953-2048/19/3/024 · Cited by 180
A tool for functional brain imaging with lifespan compliance
Hill, R. M., Boto, E., Holmes, N., Hartley, C., Seedat, Z. A., Leggett, J., Roberts, G., Shah, V., Tierney, T. M., Woolrich, M. W., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-12486-x · Cited by 180
A microfabricated optically-pumped magnetic gradiometer
Sheng, D., Perry, A. R., Krzyzewski, S. P., Geller, S., Kitching, J., & Knappe, S. (2017) · Applied Physics Letters · doi:10.1063/1.4974349 · Cited by 179
Highly sensitive magnetometers—a review
Robbes, D. (2006) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2005.11.023 · Cited by 177
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174
Sensitivity enhancement in solution NMR: Emerging ideas and new frontiers
Lee, J. H., Okuno, Y., & Cavagnero, S. (2014) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2014.01.005 · Cited by 175
“In optical magnetometry, for instance, the precession of laser-polarized alkali atoms is probed by laser light to detect small local magnetic fields below femtotesla arising from the NMR samples [146,147].”
Fully integrated, standalone zero field optically pumped magnetometer for biomagnetism
Shah, V., Osborne, J., Orton, J., & Alem, O. (2018) · Steep Dispersion Engineering and Opto-Atomic Precision Metrology XI · doi:10.1117/12.2299197 · Cited by 173
“Landmark work by Romalis and coworkers demonstrated OPM with sub-femtotesla level sensitivity using spin-exchange suppression in low magnetic fields [4].”
BackgroundBohnet, J. G., Cox, K. C., Norcia, M. A., Weiner, J. M., Chen, Z., & Thompson, J. K. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.151 · Cited by 173
“5(9) in this example data set, with measurement strengthMt = 2.”
BackgroundMulti-channel atomic magnetometer for magnetoencephalography: A configuration study
Kim, K., Begus, S., Xia, H., Lee, S.-K., Jazbinsek, V., Trontelj, Z., & Romalis, M. V. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.040 · Cited by 170
“The sensitivity of a spin-exchange relaxation free (SERF) magnetometer is sufficient for measuring an MEG signal (Kominis et al., 2003).”
Self-citationSpin squeezing of 1011 atoms by prediction and retrodiction measurements
Bao, H., Duan, J., Jin, S., Lu, X., Li, P., Qu, W., Wang, M., Novikova, I., Mikhailov, E. E., Zhao, K.-F., et al. (2020) · Nature · doi:10.1038/s41586-020-2243-7 · Cited by 167
Magnetic resonance imaging with an optical atomic magnetometer
Xu, S., Yashchuk, V. V., Donaldson, M. H., Rochester, S. M., Budker, D., & Pines, A. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0605396103 · Cited by 168
IFCN-endorsed practical guidelines for clinical magnetoencephalography (MEG)
Hari, R., Baillet, S., Barnes, G., Burgess, R., Forss, N., Gross, J., Hämäläinen, M., Jensen, O., Kakigi, R., Mauguière, F., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.03.042 · Cited by 167
“Optically pumpedmagnetometers (OPMs) (Kominis et al., 2003) have also been introduced for brain recordings although their use in large multichannel instruments is still under exploration (Boto et al.”
BackgroundSub-Projection-Noise Sensitivity in Broadband Atomic Magnetometry
Koschorreck, M., Napolitano, M., Dubost, B., & Mitchell, M. W. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.093602 · Cited by 165
Parahydrogen-enhanced zero-field nuclear magnetic resonance
Theis, T., Ganssle, P., Kervern, G., Knappe, S., Kitching, J., Ledbetter, M. P., Budker, D., & Pines, A. (2011) · Nature Physics · doi:10.1038/nphys1986 · Cited by 165
Search for axion-like dark matter with spin-based amplifiers
Jiang, M., Su, H., Garcon, A., Peng, X., & Budker, D. (2021) · Nature Physics · doi:10.1038/s41567-021-01392-z · Cited by 163
“Compared to 87Rb magnetometer, K magnetometer has demonstrated higher sensitivity [4, 20] and a 3He-39K spin-based amplifier can achieve larger amplification factor as stated below.”
A high-sensitivity laser-pumped Mx magnetometer
Groeger, S., Bison, G., Schenker, J.-L., Wynands, R., & Weis, A. (2006) · The European Physical Journal D · doi:10.1140/epjd/e2006-00037-y · Cited by 164
“The coating can signi cantly lengthen the spin-relaxation time up to a second [9].”
BackgroundNon-Invasive Functional-Brain-Imaging with an OPM-based Magnetoencephalography System
Borna, A., Carter, T. R., Colombo, A. P., Jau, Y.-Y., McKay, J., Weisend, M., Taulu, S., Stephen, J. M., & Schwindt, P. D. D. (2020) · PLOS ONE · doi:10.1371/journal.pone.0227684 · Cited by 158
“These sensors operate in the spin-exchange-relaxation-free (SERF) regime [7].”
BackgroundOptical magnetometer array for fetal magnetocardiography
Wyllie, R., Kauer, M., Wakai, R. T., & Walker, T. G. (2012) · Optics Letters · doi:10.1364/ol.37.002247 · Cited by 169
Nanoscale light–matter interactions in atomic cladding waveguides
Stern, L., Desiatov, B., Goykhman, I., & Levy, U. (2013) · Nature Communications · doi:10.1038/ncomms2554 · Cited by 159
Tarduno, J. A., Cottrell, R. D., & Smirnov, A. V. (2006) · Reviews of Geophysics · doi:10.1029/2005rg000189 · Cited by 160
“…[Wikswo, 1996; Weiss et al., 2001] or the atomic RG1002 Tarduno et al.: PALEOMAGNETISM OF SINGLE SILICATE CRYSTALS 6 of 31 RG1002 magnetometer [Kominis et al., 2003; Fitzgerald, 2003], notwithstanding debate on the subject [e.g., Wikswo, 2004], might ultimately assist efforts to read the…”
BackgroundDetection of NMR signals with a radio-frequency atomic magnetometer
Savukov, I., Seltzer, S. J., & Romalis, M. V. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.12.012 · Cited by 153
Self-citationQuantum Kalman Filtering and the Heisenberg Limit in Atomic Magnetometry
Geremia, J. M., Stockton, J. K., Doherty, A. C., & Mabuchi, H. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.250801 · Cited by 190
Four-channel optically pumped atomic magnetometer for magnetoencephalography
Colombo, A. P., Carter, T. R., Borna, A., Jau, Y., Johnson, C., Dagel, A. L., & Schwindt, P. D. D. (2016) · Optics Express · doi:10.1364/oe.24.015403 · Cited by 162
Theoretical advantages of a triaxial optically pumped magnetometer magnetoencephalography system
Brookes, M. J., Boto, E., Rea, M., Shah, V., Osborne, J., Holmes, N., Hill, R. M., Leggett, J., Rhodes, N., & Bowtell, R. W. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118025 · Cited by 165
Can a Quantum Nondemolition Measurement Improve the Sensitivity of an Atomic Magnetometer?
Auzinsh, M. P., Budker, D., Kimball, D. F. J., Rochester, S., Stalnaker, J. E., Sushkov, A. O., & Yashchuk, V. V. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.173002 · Cited by 153
Kuwahata, A., Kitaizumi, T., Saichi, K., Sato, T., Igarashi, R., Ohshima, T., MASUYAMA, Y., Iwasaki, T., Hatano, M., Jelezko, F., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-59064-6 · Cited by 161
SERF Atomic Magnetometer–Recent Advances and Applications: A Review
Li, J., Quan, W., Zhou, B., Wang, Z., Lu, J., Hu, Z., Liu, G., & Fang, J. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2863707 · Cited by 166
“During the early stage of atomic magnetometer research, hot airflow heating was widely employed by major research institutes, such as Princeton university [1], UC Berkeley [33], Sandia National Laboratory [44], etc.”
BackgroundMethodObject perception in underwater environments: a survey on sensors and sensing methodologies
Huy, D. Q., Sadjoli, N., Azam, A. B., Elhadidi, B., Cai, Y., & Seet, G. (2022) · Ocean Engineering · doi:10.1016/j.oceaneng.2022.113202 · Cited by 161
Single-molecule scale magnetic resonance spectroscopy using quantum diamond sensors
Du, J., Shi, F., Kong, X., Jelezko, F., & Wrachtrup, J. (2024) · Reviews of Modern Physics · doi:10.1103/revmodphys.96.025001 · Cited by 196
Microscopic magnetic-field imaging
Wildermuth, S., Hofferberth, S., Lesanovsky, I., Haller, E., Andersson, L. M., Groth, S., Bar-Joseph, I., Krüger, P., & Schmiedmayer, J. (2005) · Nature · doi:10.1038/435440a · Cited by 142
Low-noise high-density alkali-metal scalar magnetometer
Smullin, S., Savukov, I., Vasilakis, G., Ghosh, R. K., & Romalis, M. V. (2009) · Physical Review A · doi:10.1103/physreva.80.033420 · Cited by 143
Self-citationHigh-temperature alkali vapor cells with antirelaxation surface coatings
Seltzer, S. J., & Romalis, M. V. (2009) · Journal of Applied Physics · doi:10.1063/1.3236649 · Cited by 148
Self-citationTayler, M. C. D., Theis, T., Sjolander, T. F., Blanchard, J. W., Kentner, A., Pustelny, S., Pines, A., & Budker, D. (2017) · Review of Scientific Instruments · doi:10.1063/1.5003347 · Cited by 141
Towards OPM-MEG in a Virtual Reality Environment
Roberts, G., Holmes, N., Alexander, N., Boto, E., Leggett, J., Hill, R. M., Shah, V., Rea, M., Vaughan, R., Maguire, E. A., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.010 · Cited by 128
“However, recent developments in quantum technology have led to the introduction of new sensors known as optically-pumped magnetometers (OPMs) (Kominis et al., 2003).”
BackgroundUltra-sensitive magnetometry based on free precession of nuclear spins
Gemmel, C., Heil, W., Karpuk, S., Lenz, K., Ludwig, C., Sobolev, Y., Tullney, K., Burghoff, M., Kilian, W., Knappe-Grüneberg, S., et al. (2010) · The European Physical Journal D · doi:10.1140/epjd/e2010-00044-5 · Cited by 165
Hyperpolarized xenon in NMR and MRI
Oros, A. M., & Shah, N. J. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/20/r01 · Cited by 152
Strand, S., Lutter, W., Strasburger, J. F., Shah, V., Baffa, O., & Wakai, R. T. (2019) · Journal of the American Heart Association · doi:10.1161/jaha.119.013436 · Cited by 136
“This situation changed, however, following the demonstration of a new type of optically pumped magnetometer (OPM) that can achieve SQUID sensitivity in a room temperature device.(7) In the succeeding years, considerable effort has been devoted to making OPMs small and easy to use.”
BackgroundNear-Zero-Field Nuclear Magnetic Resonance
Ledbetter, M. P., Theis, T., Blanchard, J. W., Ring, H. L., Ganssle, P. J., Appelt, S., Blümich, B., Pines, A., & Budker, D. (2011) · Physical Review Letters · doi:10.1103/physrevlett.107.107601 · Cited by 135
Magnetocardiography with a 16-channel fiber-coupled single-cell Rb optically pumped magnetometer
Kim, Y. J., Savukov, I., & Newman, S. (2019) · Applied Physics Letters · doi:10.1063/1.5094339 · Cited by 133
Precision Magnetometers for Aerospace Applications: A Review
Bennett, J. S., Vyhnalek, B. E., Greenall, H., Bridge, E. M., Gotardo, F., Forstner, S., Harris, G. I., Miranda, F. A., & Bowen, W. P. (2021) · Sensors · doi:10.3390/s21165568 · Cited by 145
Parametric modulation of an atomic magnetometer
Li, Z., Wakai, R. T., & Walker, T. G. (2006) · Applied Physics Letters · doi:10.1063/1.2357553 · Cited by 135
Zero-field remote detection of NMR with a microfabricated atomic magnetometer
Ledbetter, M. P., Savukov, I., Budker, D., Shah, V., Knappe, S. A., Kitching, J. E., Michalak, D. J., Xu, S., & Pines, A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0711505105 · Cited by 133
Colloquium : Quantum limits to the energy resolution of magnetic field sensors
Mitchell, M. W., & Palacios, S. (2020) · Reviews of Modern Physics · doi:10.1103/revmodphys.92.021001 · Cited by 148
“Volumetric sensors include OPMs (Dang et al., 2010a; Gawlik and Pustelny, 2017; Griffith et al., 2010; Jiménez-Mart́ınez and Knappe, 2017; Kominis et al., 2003; Savukov, 2017; Weis et al., 2017), ensemble NVD sensors (Barry et al., 2016; Jensen et al., 2017; Wolf et al., 2015), and others.”
BackgroundMulti-sensor magnetoencephalography with atomic magnetometers
Johnson, C., Schwindt, P. D. D., & Weisend, M. P. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/17/6065 · Cited by 144
“0031-9155/13/176065+13$33.00 © 2013 Institute of Physics and Engineering in Medicine Printed in the UK & the USA 6065 Over the past decade, AM technology has advanced into the sub-fT sensitivity range (Kominis et al 2003) with a record sensitivity of 0.2 fT/ √ Hz (Dang et al 2010).”
BackgroundInfluential
Metadata
- Authors
- Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V.
- Affiliations
- Princeton University (US)
- University of Washington (US)
- Corresponding author
- Romalis, M. V.
- Venue
- Nature
- Published
- 2003-04
- Volume
- 422
- Issue
- 6932
- Pages
- 596-599
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W1963919378
- Cited by
- 1,631
- References
- 28
- Citations by year
- 2026: 122 · 2025: 167 · 2024: 141 · 2023: 148 · 2022: 132 · 2021: 112 · 2020: 88 · 2019: 80 · 2018: 68 · 2017: 55 · 2016: 62 · 2015: 53 · 2014: 42 · 2013: 44 · 2012: 40
- FWCI
- 17.25
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Funders
- David and Lucile Packard Foundation
- Princeton University
- National Institutes of Health
- Lawrence Berkeley National Laboratory
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- atomic magnetometer, magnetic localization, measurement volume, magnetoencephalography, optically pumped atoms
- MeSH terms
- Magnetics, Sensitivity and Specificity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.