Label-free immunodetection with CMOS-compatible semiconducting nanowires
The DOI matches its Crossref record; 31 of the 32 references it cites were found in a registry or an index.
Abstract
Semiconducting nanowires have the potential to function as highly sensitive and selective sensors for the label-free detection of low concentrations of pathogenic microorganisms. Successful solution-phase nanowire sensing has been demonstrated for ions, small molecules, proteins, DNA and viruses; however, 'bottom-up' nanowires (or similarly configured carbon nanotubes) used for these demonstrations require hybrid fabrication schemes, which result in severe integration issues that have hindered widespread application. Alternative 'top-down' fabrication methods of nanowire-like devices produce disappointing performance because of process-induced material and device degradation. Here we report an approach that uses complementary metal oxide semiconductor (CMOS) field effect transistor compatible technology and hence demonstrate the specific label-free detection of below 100 femtomolar concentrations of antibodies as well as real-time monitoring of the cellular immune response. This approach eliminates the need for hybrid methods and enables system-scale integration of these sensors with signal processing and information systems. Additionally, the ability to monitor antibody binding and sense the cellular immune response in real time with readily available technology should facilitate widespread diagnostic applications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,809
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Directed Assembly of One-Dimensional Nanostructures into Functional Networks
Huang, Y., Duan, X., Wei, Q., & Lieber, C. M. (2001) · Science · doi:10.1126/science.291.5504.630 · Cited by 2,199
Physics of semiconductor devices /2nd edition/
Sze, S. M. (1981) · New York eBooks · Cited by 1,599
Hahm, J.-I., & Lieber, C. M. (2004) · Nano Letters · doi:10.1021/nl034853b · Cited by 1,308
Electrical detection of single viruses
Patolsky, F., Zheng, G., Hayden, O., Lakadamyali, M., Zhuang, X., & Lieber, C. M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406159101 · Cited by 1,258
The Physics of Semi-Conductor Devices: D. A.Fraser Clarendon Press, Oxford, 1977; p. IX–148
Quaranta, A. A. (1979) · Il Nuovo Cimento B Series 11 · doi:10.1007/bf02743444 · Cited by 1,170
(1996) · Elsevier eBooks · doi:10.1016/b978-0-12-342335-1.x5000-3 · Cited by 1,016
Intermolecular and Surface Forces
(2011) · doi:10.1016/c2009-0-21560-1 · Cited by 871
Sequence-Specific Label-Free DNA Sensors Based on Silicon Nanowires
Li, Z., Chen, Y., Li, X., Kamins, T. I., Nauka, K., & Williams, R. S. (2004) · Nano Letters · doi:10.1021/nl034958e · Cited by 706
Cited by
Items 101–200 of 1,000
Nanostructure-based electrical biosensors
Roy, S., & Gao, Z. (2009) · Nano Today · doi:10.1016/j.nantod.2009.06.003 · Cited by 174
Silicon nanowire field-effect-transistor based biosensors: From sensitive to ultra-sensitive
Shen, M.-Y., Li, B.-R., & Li, Y.-K. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.03.057 · Cited by 171
Si, SiGe Nanowire Devices by Top–Down Technology and Their Applications
Singh, N., Buddharaju, K. D., Manhas, S. K., Agarwal, A., Rustagi, S. C., Lo, G. Q., Balasubramanian, N., & Kwong, D.-L. (2008) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2008.2005154 · Cited by 171
Tripathi, K. M., Kim, T., Losic, D., & Tung, T. T. (2016) · Carbon · doi:10.1016/j.carbon.2016.08.040 · Cited by 171
Electrolytic Gated Organic Field-Effect Transistors for Application in Biosensors—A Review
Wang, D., Noël, V., & Piro, B. (2016) · Electronics · doi:10.3390/electronics5010009 · Cited by 165
Zhang, G.-J., Chua, J. H., Chee, R.-E., Agarwal, A., Wong, S. M., Buddharaju, K. D., & Balasubramanian, N. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.02.006 · Cited by 161
“For this reaon, low ionic strength buffer solutions were used for all reports n SiNW biosensors for DNA or proteins (Hahm and Lieber, 004; Li et al., 2004; Zheng et al., 2005; Stern et al., 2007).”
BackgroundMethodInfluentialHybrid strategies in nanolithography
Saavedra, H. M., Mullen, T. J., Zhang, P., Dewey, D. C., Claridge, S. A., & Weiss, P. S. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/3/036501 · Cited by 167
Ghittorelli, M., Lingstedt, L., Romele, P., Crăciun, N. I., Kovács-Vajna, Z. M., Blom, P. W. M., & Torricelli, F. (2018) · Nature Communications · doi:10.1038/s41467-018-03932-3 · Cited by 163
Al2O3/Silicon NanoISFET with Near Ideal Nernstian Response
Chen, S., Bomer, J. G., Carlen, E. T., & van den Berg, A. (2011) · Nano Letters · doi:10.1021/nl200623n · Cited by 164
Recent advances in nanowires-based field-effect transistors for biological sensor applications
Ahmad, R., Mahmoudi, T., Ahn, M.-S., & Hahn, Y.-B. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.09.024 · Cited by 162
“Further in recent reports by Stern et al. (2007a), (2007b), the streptavidin detection limit was improved to fM concentration using top-down fabrication methods.”
BackgroundSilicon Nanowires for Gas Sensing: A Review
Akbari-Saatlu, M., Procek, M., Mattsson, C., Thungström, G., Nilsson, H.-E., Xiong, W., Xu, B., Li, Y., & Radamson, H. H. (2020) · Nanomaterials · doi:10.3390/nano10112215 · Cited by 159
“The lithography technique is presented by photolithography [51–53], E-beam lithography [47,48,54,55], deep UV (DUV) nanoimprint lithography [53,56], and side-wall transfer lithography (STL) process [57,58].”
MethodOn the origin of enhanced sensitivity in nanoscale FET-based biosensors
Shoorideh, K., & Chui, C. O. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1315485111 · Cited by 162
Real-time imaging of microparticles and living cells with CMOS nanocapacitor arrays
Laborde, C., Pittino, F., Verhoeven, H. A., Lemay, S. G., Selmi, L., Jongsma, M. A., & Widdershoven, F. P. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.163 · Cited by 164
Graphene Solution‐Gated Field‐Effect Transistor Array for Sensing Applications
Dankerl, M., Hauf, M. V., Lippert, A., Hess, L. H., Birner, S., Sharp, I. D., Mahmood, A., Mallet, P., Veuillen, J., Stutzmann, M., et al. (2010) · Advanced Functional Materials · doi:10.1002/adfm.201000724 · Cited by 163
Nanowire sensors for multiplexed detection of biomolecules
He, B., Morrow, T. J., & Keating, C. D. (2008) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2008.08.027 · Cited by 159
Microfluidic Chips for Immunoassays
Han, K. N., Li, C. A., & Seong, G. H. (2013) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062012-092616 · Cited by 160
Zhang, T., Lang, Q., Yang, D., Li, L., Zeng, L., Zheng, C., Li, T., Wei, M., & Liu, A. (2013) · Electrochimica Acta · doi:10.1016/j.electacta.2013.05.055 · Cited by 161
Electrochemical biosensors at the nanoscale
Wei, D., Bailey, M. J. A., Andrew, P., & Ryhänen, T. (2009) · Lab on a Chip · doi:10.1039/b903118a · Cited by 158
Lowe, B. M., Sun, K., Zeimpekis, I., Skylaris, C., & Green, N. G. (2017) · The Analyst · doi:10.1039/c7an00455a · Cited by 171
Bespalov, I., Datler, M., Buhr, S., Drachsel, W., Rupprechter, G., & Suchorski, Y. (2015) · Ultramicroscopy · doi:10.1016/j.ultramic.2015.02.016 · Cited by 156
An ultrasensitive and low-cost graphene sensor based on layer-by-layer nano self-assembly
Zhang, B., & Cui, T. (2011) · Applied Physics Letters · doi:10.1063/1.3557504 · Cited by 155
Dual‐Gate Organic Field‐Effect Transistors as Potentiometric Sensors in Aqueous Solution
Spijkman, M., Brondijk, J. J., Geuns, T. C. T., Smits, E. C. P., Cramer, T., Zerbetto, F., Stoliar, P., Biscarini, F., Blom, P. W. M., & de Leeuw, D. M. (2010) · Advanced Functional Materials · doi:10.1002/adfm.200901830 · Cited by 154
Strain induced change of bandgap and effective mass in silicon nanowires
Shiri, D., Kong, Y., Buin, A., & Anantram, M. P. (2008) · Applied Physics Letters · doi:10.1063/1.2973208 · Cited by 161
Nanostructuring of Sensors Determines the Efficiency of Biomolecular Capture
Bin, X., Sargent, E. H., & Kelley, S. O. (2010) · Analytical Chemistry · doi:10.1021/ac101164n · Cited by 154
Translational nanomedicine: status assessment and opportunities
Murday, J. S., Siegel, R. W., Stein, J. A., & Wright, J. F. (2009) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2009.06.001 · Cited by 176
Determination of Molecular Configuration by Debye Length Modulation
Vacic, A., Criscione, J. M., Rajan, N. K., STERN, E. W., Fahmy, T. M., & Reed, M. A. (2011) · Journal of the American Chemical Society · doi:10.1021/ja205684a · Cited by 152
Self-citationLook, M., Bandyopadhyay, A., Blum, J. S., & Fahmy, T. M. (2009) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.011 · Cited by 166
“An alternative nanoscale diagnostic strategy is to use semiconducting nanowires as an electrical transducer for serological measurements [166] and functional responses by antigenspecific immune cells [167].”
BackgroundSelf-citationSilicon Nanowire‐Based Devices for Gas-Phase Sensing
Cao, A., Sudhölter, E. J. R., & de Smet, L. C. P. M. (2013) · Sensors · doi:10.3390/s140100245 · Cited by 166
“Compared to devices prepared from carbon nanotubes and organic materials like wires from conducting polymers, SiNW-based devices are more compatible with very-large-scale integration (VLSI) processes and complementary metal–oxide–semiconductor (CMOS) technologies [12,13].”
MethodReal‐Time DNA Detection Using Reduced Graphene Oxide Field Effect Transistors
Stine, R., Robinson, J. T., Sheehan, P. E., & Tamanaha, C. R. (2010) · Advanced Materials · doi:10.1002/adma.201002121 · Cited by 151
Dorvel, B. R., Reddy, B., Go, J., Duarte-Guevara, C., Salm, E. M., Alam, M. A., & Bashir, R. (2012) · ACS Nano · doi:10.1021/nn301495k · Cited by 154
“The wires were then defined via electron beam lithography and wet etched with 25% TMAH to define the active silicon area.(16,60) The source and drain regions were doped with boron (doping 10(19)/cm(3)) by ion implantation and annealed at 1000 C for 5 min to active the dopants.”
MethodA Calibration Method for Nanowire Biosensors to Suppress Device-to-Device Variation
Ishikawa, F. N., Curreli, M., Chang, H.-K., Chen, P.-C., Zhang, R., Côté, R. J., Thompson, M. E., & Zhou, C. (2009) · ACS Nano · doi:10.1021/nn9011384 · Cited by 163
Rapid Flu Diagnosis Using Silicon Nanowire Sensor
Shen, F., Wang, J., Xu, Z., Wu, Y. H., Chen, Q., Li, X., Xu, J., Li, L., Yao, M., Guo, X., et al. (2012) · Nano Letters · doi:10.1021/nl301516z · Cited by 149
Recent advances in nano-materials for packaging of electronic devices
Zhang, S., Xu, X., Lin, T., & He, P. (2019) · Journal of Materials Science Materials in Electronics · doi:10.1007/s10854-019-01790-3 · Cited by 148
InAs Nanowire Transistors as Gas Sensor and the Response Mechanism
Du, J., Dong, L., Tang, H., & Gao, X. (2009) · Nano Letters · doi:10.1021/nl902611f · Cited by 171
Silicon Nanowire Field-Effect Transistors—A Versatile Class of Potentiometric Nanobiosensors
Mu, L., Chang, Y., Sawtelle, S. D., Wipf, M., Duan, X., & Reed, M. A. (2015) · IEEE Access · doi:10.1109/access.2015.2422842 · Cited by 156
“Stern et al. also used a mask-and-etch method to fabricate nanowires from optically defined nanoribbons, using tetramethylammonium hydroxide (TMAH) [11].”
BackgroundMethodSelf-citationSemiconducting Nanowire Field-Effect Transistor Biomolecular Sensors
Stern, E., Vacic, A., & Reed, M. A. (2008) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2008.2005168 · Cited by 163
“5(c) and (d)], rendering this scheme unacceptable [56].”
BackgroundMethodSelf-citationUniversal Block Copolymer Lithography for Metals, Semiconductors, Ceramics, and Polymers
Jeong, S., Xia, G., Kim, B. H., Shin, D. O., Kwon, S., Kang, S., & Kim, S. O. (2008) · Advanced Materials · doi:10.1002/adma.200702930 · Cited by 158
Surface Functionalization of Zinc Oxide by Carboxyalkylphosphonic Acid Self-Assembled Monolayers
Zhang, B., Kong, T., Xu, W., Su, R., Gao, Y., & Cheng, G. (2010) · Langmuir · doi:10.1021/la9042827 · Cited by 145
Palladium/silicon nanowire Schottky barrier-based hydrogen sensors
Skucha, K., Fan, Z., Jeon, K., Javey, A., & Boser, B. E. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.11.067 · Cited by 152
“(1) into (2), and noting that sensor resistance is inversely proportional to the current for a constant bias Vds, yields the sensor response: Rf − R0 R0 = R R0 = C × [H2] (3)”
Magnetic sensing platform technologies for biomedical applications
Lin, G., Makarov, D., & Schmidt, O. G. (2017) · Lab on a Chip · doi:10.1039/c7lc00026j · Cited by 153
Label‐Free Sensing of Biomolecules with Field‐Effect Devices for Clinical Applications
Poghossian, A., & Schöning, M. J. (2014) · Electroanalysis · doi:10.1002/elan.201400073 · Cited by 142
Nanowired Bioelectric Interfaces: Focus Review
Tian, B., & Lieber, C. M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00795 · Cited by 146
Ultrasensitive Field‐Effect Biosensors Enabled by the Unique Electronic Properties of Graphene
Zhang, X., Jing, Q., Shen, A., Schneider, G. F., Kireev, D., Zhang, Z., & Fu, W. (2019) · Small · doi:10.1002/smll.201902820 · Cited by 148
Biologically sensitive field-effect transistors: from ISFETs to NanoFETs
Pachauri, V., & Ingebrandt, S. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150009 · Cited by 152
Effect of Nanowire Number, Diameter, and Doping Density on Nano-FET Biosensor Sensitivity
Li, J., Zhang, Y., To, S., You, L., & Sun, Y. (2011) · ACS Nano · doi:10.1021/nn202182p · Cited by 138
Label-free technologies for quantitative multiparameter biological analysis
Qavi, A. J., Washburn, A. L., Byeon, J.-Y., & Bailey, R. C. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-2637-8 · Cited by 138
Engineering Applications of Biomolecular Motors
Hess, H. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124644 · Cited by 153
“The ongoing research into nanoscale sensors, such as semiconducting nanowires (79), may provide the ideal detector as partner for an active aggregation step.”
BackgroundIII-nitride micro-emitter arrays: development and applications
Fan, Z., Lin, J. Y., & Jiang, H. X. (2008) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/41/9/094001 · Cited by 137
Lee, H.-S., Kim, K. S., Kim, C., Hahn, S. K., & Jo, M. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.08.036 · Cited by 137
“…(NW-FETs) can be a promising one, because they can provide the high sensitivity, specificity, direct and label-free electrical readout scheme (Byon and Choi, 2006; Cui et al., 2001; Gao et al., 2007; Hahm and Lieber, 2004; Kim et al., 2007; Patolsky et al., 2004, 2006; Stern et al., 2007).”
BackgroundKong, T., Su, R., Zhang, B., Zhang, Q., & Cheng, G. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.02.019 · Cited by 136
Nanogap Field‐Effect Transistor Biosensors for Electrical Detection of Avian Influenza
Gu, B., Park, T. J., Ahn, J., Huang, X., Lee, S. Y., & Choi, Y. (2009) · Small · doi:10.1002/smll.200900450 · Cited by 134
Hammock, M. L., Knopfmacher, O., Naab, B. D., Tok, J. B.-H., & Bao, Z. (2013) · ACS Nano · doi:10.1021/nn305903q · Cited by 128
Aptamer-Based Field-Effect Transistor for Detection of Avian Influenza Virus in Chicken Serum
Kwon, J. H., Lee, Y., Lee, T., & Ahn, J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c00348 · Cited by 137
Silicon nanowires as field-effect transducers for biosensor development: A review
Noor, M. O., & Krull, U. J. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.03.016 · Cited by 139
Li, Y., Yang, C., & Guo, X. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.9b00347 · Cited by 133
Kinked p–n Junction Nanowire Probes for High Spatial Resolution Sensing and Intracellular Recording
Jiang, Z., Qing, Q., Xie, P., Gao, R., & Lieber, C. M. (2012) · Nano Letters · doi:10.1021/nl300256r · Cited by 149
Gas Detection with Vertical InAs Nanowire Arrays
Offermans, P., Crego‐Calama, M., & Brongersma, S. H. (2010) · Nano Letters · doi:10.1021/nl1005405 · Cited by 146
Lin, C.-H., Hung, C.-H., Hsiao, C.-Y., Lin, H., Ko, F., & Yang, Y. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.03.014 · Cited by 130
“Silicon nanowires (SiNWs) have recently been developed to function as transducer for ultrasensitive biosensors and chemical sensors (Hsiao et al., 2009; Lin et al., 2008; Gao et al., 2007; Stern et al., 2007; Li et al., 2004; Patolsky et al., 2004; Cui et al., 2001).”
BackgroundRobust ultrasensitive tunneling-FET biosensor for point-of-care diagnostics
Gao, A., Lü, N., Wang, Y., & Li, T. (2016) · Scientific Reports · doi:10.1038/srep22554 · Cited by 135
“(a) ID/VG curve measured in solutions at different pH values (5, 6, 7, 8, 9) for VD = 1 V.”
Recent Advancements in Electrochemical Biosensors for Monitoring the Water Quality
Hui, Y., Huang, Z., Alahi, M. E. E., Nag, A., Feng, S., & Mukhopadhyay, S. C. (2022) · Biosensors · doi:10.3390/bios12070551 · Cited by 139
Martínez, J. I., Martínez, R. V., & Garcia, R. A. (2008) · Nano Letters · doi:10.1021/nl801599k · Cited by 138
Noy, A. (2010) · Advanced Materials · doi:10.1002/adma.201003751 · Cited by 140
Electrophoretic and field-effect graphene for all-electrical DNA array technology
Xu, G., Abbott, J., Qin, L., Yeung, K. Y. M., Song, Y., Yoon, H., Kong, J., & Ham, D. (2014) · Nature Communications · doi:10.1038/ncomms5866 · Cited by 126
High performance of ZnO nanowire protein sensors enhanced by the piezotronic effect
Yu, R., Pan, C., & Wang, Z. L. (2012) · Energy & Environmental Science · doi:10.1039/c2ee23718k · Cited by 125
Eivazzadeh‐Keihan, R., Pashazadeh‐Panahi, P., Mahmoudi, T., Chenab, K. K., Baradaran, B., Hashemzaei, M., Radinekiyan, F., Mokhtarzadeh, A., & Maleki, A. R. (2019) · Microchimica Acta · doi:10.1007/s00604-019-3420-y · Cited by 125
Ajay, Narang, R., Saxena, M. K., & Gupta, M. (2015) · Superlattices and Microstructures · doi:10.1016/j.spmi.2015.04.040 · Cited by 125
Mechanism and Optimization of pH Sensing Using SnO2 Nanobelt Field Effect Transistors
Cheng, Y., Xiong, P., Yun, C. S., Strouse, G. F., Zheng, J. P., Yang, R., & Wang, Z. L. (2008) · Nano Letters · doi:10.1021/nl801696b · Cited by 121
Optimal signal-to-noise ratio for silicon nanowire biochemical sensors
Rajan, N. K., Routenberg, D. A., & Reed, M. A. (2011) · Applied Physics Letters · doi:10.1063/1.3608155 · Cited by 121
Self-citationLü, N., Gao, A., Dai, P., Song, S., Fan, C., Wang, Y., & Li, T. (2014) · Small · doi:10.1002/smll.201302990 · Cited by 128
Charge Transport Dilemma of Solution-Processed Nanomaterials
Kim, J., & Kotov, N. A. (2013) · Chemistry of Materials · doi:10.1021/cm402675k · Cited by 128
Improving the Limit of Detection of Nanoscale Sensors by Directed Binding to High-Sensitivity Areas
Feuz, L., Jönsson, P., Jonsson, M. P., & Höök, F. (2010) · ACS Nano · doi:10.1021/nn901457f · Cited by 119
Advances in nanowire bioelectronics
Zhou, W., Dai, X., & Lieber, C. M. (2017) · Reports on Progress in Physics · doi:10.1088/0034-4885/80/1/016701 · Cited by 117
Molecular Analysis of Blood with Micro‐/Nanoscale Field‐Effect‐Transistor Biosensors
Makowski, M. S., & Ivanisevic, A. (2011) · Small · doi:10.1002/smll.201100211 · Cited by 132
Kim, J.-Y., Ahn, J., Choi, S., Im, M., Kim, S., Duarte, J. P., Kim, C., Park, T. J., Lee, S. Y., & Choi, Y. (2011) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2011.2175006 · Cited by 119
“ever, unlike reported biosensors that were placed in bionic solution [6], [7], the previously presented underlap-FET biosensor was exposed in air ambient during measurement.”
BackgroundReview of nanostructured devices for thermoelectric applications
Pennelli, G. (2014) · Beilstein Journal of Nanotechnology · doi:10.3762/bjnano.5.141 · Cited by 131
Angione, M. D., Cotrone, S., Magliulo, M., Mallardi, A., Altamura, D., Giannini, C., Cioffi, N., Sabbatini, L., Fratini, E., Baglioni, P., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1200549109 · Cited by 128
“Nanostructured channel materials allow both the close coupling between the biorecognition event and the field-induced transport, along with a conveniently low interaction cross-section, both contributing to achieve extremely sensitive responses (6, 8).”
BackgroundDesign of Surface Modifications for Nanoscale Sensor Applications
Reimhult, E., & Höök, F. (2015) · Sensors · doi:10.3390/s150101635 · Cited by 125
“For example, semiconductor nanowires sense changes in interfacial charge [13,14], which makes them best suited to probe highly charged molecules, such as DNA, that strongly increase the charge accumulation close to the sensor surface or charge translocation across cell-membrane mimics.”
BackgroundThin Film Polycrystalline Silicon Nanowire Biosensors
Hakim, M. M. A., Lombardini, M., Sun, K., Giustiniano, F., Roach, P. L., Davies, D. E., Howarth, P. H., de Planque, M. R. R., Morgan, H., & Ashburn, P. (2012) · Nano Letters · doi:10.1021/nl2042276 · Cited by 116
Krivitsky, V., Hsiung, L.-C., Lichtenstein, A., Brudnik, B., Kantaev, R., Elnathan, R., Pevzner, A., Khatchtourints, A., & Patolsky, F. (2012) · Nano Letters · doi:10.1021/nl3021889 · Cited by 123
Timko, B. P., Cohen-Karni, T., Qing, Q., Tian, B., & Lieber, C. M. (2010) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2009.2031807 · Cited by 114
“... with an SNR >3 for concentrations down to 75 fg/mL, or approximately 2 fM [36]; this represents a sensitivity limit 10 4 –10 9 times below that afforded by stateof-the-art ion sensitive planar FETs [39]–[41]! It is important to note that these exquisite sensitivities were also verified by a different group in 2007…”
BackgroundMethodParallel Array InAs Nanowire Transistors for Mechanically Bendable, Ultrahigh Frequency Electronics
Takahashi, T., Takei, K., Adabi, E., Fan, Z., Niknejad, A. M., & Javey, A. (2010) · ACS Nano · doi:10.1021/nn1018329 · Cited by 114
Ajay, Narang, R., Saxena, M., & Gupta, M. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2716102 · Cited by 114
“2716102 advantages over other methods including direct transduction, high sensitivity, mass production, miniaturization and compatibility with the standard complementary metal-oxidesemiconductor (CMOS) technology [7].”
BackgroundA 256 Pixel Magnetoresistive Biosensor Microarray in 0.18 µm CMOS
Hall, D. A., Gaster, R. S., Makinwa, K. A. A., Wang, S. X., & Murmann, B. (2013) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2245058 · Cited by 122
“On the other hand, label-free techniques detect an intrinsic property of the biomolecule, such as the mass [14], charge [15], thermal reactivity [16], size [17], or its optical interaction with a surface [18].”
BackgroundTran, D. P., Pham, T. T. T., Wolfrum, B. L., Offenhäusser, A., & Thierry, B. (2018) · Materials · doi:10.3390/ma11050785 · Cited by 114
“Various metals and metallic alloys including Al [32,62–64], Ti [18,57,65], Pt [66–68], Co [69,70], Ni [71–73], and Cr [62,64,74] can be vacuum deposited to form good Ohmic contacts with SiNWs.”
BackgroundDesign and Synthesis of Nanostructured Materials for Sensor Applications
Noah, N. M. (2020) · Journal of Nanomaterials · doi:10.1155/2020/8855321 · Cited by 119
“Many novel structures such as nanowires which can be used to detect biological samples without labelling have been fabricated using this approach [15].”
BackgroundAnalytical techniques for multiplex analysis of protein biomarkers
van Gool, A. J., Corrales, F. J., Čolović, M. B., Krstic, D. Z., Oliver‐Martos, B., Martínez-Cáceres, E. M., Jakaša, I., Gajski, G., Brun, V., Kyriacou, K. C., et al. (2020) · Expert Review of Proteomics · doi:10.1080/14789450.2020.1763174 · Cited by 120
“effect transistors (immunoFETs) [150,151] are promising technologies for label-free sensing offering ultralow sensitivities (fM),”
BackgroundAnalytical description of the metal-assisted growth of III–V nanowires: Axial and radial growths
Plante, M. C., & LaPierre, R. (2009) · Journal of Applied Physics · doi:10.1063/1.3131676 · Cited by 109
Chemical Sensing with Nanowires
Penner, R. M. (2012) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062011-143007 · Cited by 106
Doucey, M., & Carrara, S. (2018) · Trends in biotechnology · doi:10.1016/j.tibtech.2018.07.014 · Cited by 113
Kim, D., Goldstein, B., Tang, W., Sigworth, F. J., & Culurciello, E. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2192273 · Cited by 107
“Another application where a LCMS is used is in large-scale nanosensing devices [4], where low chemical and biological concentrations translate in pico-ampere to tens of nano-ampere level currents”
MethodCMOS‐Compatible Nanowire Sensor Arrays for Detection of Cellular Bioelectricity
Pui, T. S., Agarwal, A., Ye, F., Balasubramanian, N., & Chen, P. (2009) · Small · doi:10.1002/smll.200800919 · Cited by 116
Liu, S., Shen, Q. H., Cao, Y., Gan, L., Wang, Z., Steigerwald, M. L., & Guo, X. (2009) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2009.11.007 · Cited by 115
Srivastava, M., Nirala, N. R., Srivastava, S., & Prakash, R. (2018) · Scientific Reports · doi:10.1038/s41598-018-19733-z · Cited by 105
Fabrication and application of silicon nanowire transistor arrays for biomolecular detection
Vu, X. T., Moulick, R. G., Eschermann, J. F., Stockmann, R., Offenhäusser, A., & Ingebrandt, S. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.11.048 · Cited by 113
Zafar, S., D'Emic, C. P., Jagtiani, A. V., Kratschmer, E., Miao, X., Zhu, Y., Mo, R. T., Sosa, N. E., Hamann, H. F., SHAHIDI, G. G., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b01339 · Cited by 103
Current and emerging challenges of field effect transistor based bio-sensing
Matsumoto, A., & Miyahara, Y. (2013) · Nanoscale · doi:10.1039/c3nr02703a · Cited by 112
Electrochemical processes and mechanistic aspects of field-effect sensors for biomolecules
Huang, W., Diallo, A. K., Dailey, J., Besar, K., & Katz, H. E. (2015) · Journal of Materials Chemistry C · doi:10.1039/c5tc00755k · Cited by 113
Quasi-Two-Dimensional Metal Oxide Semiconductors Based Ultrasensitive Potentiometric Biosensors
Chen, H., Rim, Y. S., Wang, I. C., Li, C., Zhu, B., Sun, M., Goorsky, M. S., He, X., & Yang, Y. (2017) · ACS Nano · doi:10.1021/acsnano.7b00628 · Cited by 106
Novel Top-Down Wafer-Scale Fabrication of Single Crystal Silicon Nanowires
Tong, H. D., Chen, S., van der Wiel, W. G., Carlen, E. T., & van den Berg, A. (2009) · Nano Letters · doi:10.1021/nl803181x · Cited by 100
Arbiol, J., Estradé, S., Prades, J. D., Cirera, A., Furtmayr, F., Stark, C. J. M., Laufer, A., Stutzmann, M., Eickhoff, M., Gass, M. H., et al. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/14/145704 · Cited by 99
Metadata
- Authors
- Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A.
- Affiliations
- Yale University (US)
- Corresponding author
- Fahmy, Tarek M.
- Reed, Mark A.
- Venue
- Nature
- Published
- 2007-02
- Volume
- 445
- Issue
- 7127
- Pages
- 519-522
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2077609143
- Cited by
- 1,352
- References
- 32
- Citations by year
- 2026: 17 · 2025: 19 · 2024: 37 · 2023: 29 · 2022: 32 · 2021: 49 · 2020: 51 · 2019: 47 · 2018: 58 · 2017: 49 · 2016: 86 · 2015: 92 · 2014: 93 · 2013: 118 · 2012: 124
- FWCI
- 76.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Nanowire Synthesis and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- semiconductor nanowires, field-effect transistor sensors, antibody detection, femtomolar sensitivity, pathogen detection, top-down nanowire fabrication, sensor integration
- MeSH terms
- Animals, Antibodies, Infections, Semiconductors, Sensitivity and Specificity, T-Lymphocytes, CD3 Complex, Mice, Nanowires
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.