Label-free immunodetection with CMOS-compatible semiconducting nanowires
The DOI matches its Crossref record; 31 of the 32 references it cites were found in a registry or an index.
Abstract
Semiconducting nanowires have the potential to function as highly sensitive and selective sensors for the label-free detection of low concentrations of pathogenic microorganisms. Successful solution-phase nanowire sensing has been demonstrated for ions, small molecules, proteins, DNA and viruses; however, 'bottom-up' nanowires (or similarly configured carbon nanotubes) used for these demonstrations require hybrid fabrication schemes, which result in severe integration issues that have hindered widespread application. Alternative 'top-down' fabrication methods of nanowire-like devices produce disappointing performance because of process-induced material and device degradation. Here we report an approach that uses complementary metal oxide semiconductor (CMOS) field effect transistor compatible technology and hence demonstrate the specific label-free detection of below 100 femtomolar concentrations of antibodies as well as real-time monitoring of the cellular immune response. This approach eliminates the need for hybrid methods and enables system-scale integration of these sensors with signal processing and information systems. Additionally, the ability to monitor antibody binding and sense the cellular immune response in real time with readily available technology should facilitate widespread diagnostic applications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,809
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Directed Assembly of One-Dimensional Nanostructures into Functional Networks
Huang, Y., Duan, X., Wei, Q., & Lieber, C. M. (2001) · Science · doi:10.1126/science.291.5504.630 · Cited by 2,199
Physics of semiconductor devices /2nd edition/
Sze, S. M. (1981) · New York eBooks · Cited by 1,599
Hahm, J.-I., & Lieber, C. M. (2004) · Nano Letters · doi:10.1021/nl034853b · Cited by 1,308
Electrical detection of single viruses
Patolsky, F., Zheng, G., Hayden, O., Lakadamyali, M., Zhuang, X., & Lieber, C. M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406159101 · Cited by 1,258
The Physics of Semi-Conductor Devices: D. A.Fraser Clarendon Press, Oxford, 1977; p. IX–148
Quaranta, A. A. (1979) · Il Nuovo Cimento B Series 11 · doi:10.1007/bf02743444 · Cited by 1,170
(1996) · Elsevier eBooks · doi:10.1016/b978-0-12-342335-1.x5000-3 · Cited by 1,016
Intermolecular and Surface Forces
(2011) · doi:10.1016/c2009-0-21560-1 · Cited by 871
Sequence-Specific Label-Free DNA Sensors Based on Silicon Nanowires
Li, Z., Chen, Y., Li, X., Kamins, T. I., Nauka, K., & Williams, R. S. (2004) · Nano Letters · doi:10.1021/nl034958e · Cited by 706
Cited by
Items 801–900 of 1,000
Studying Effect Dimensions of Design and Simulation Silicon Nanowire Filed Effect Biosensor
Al-Mufti, M. W., Hashim, U., Rahman, M. M., Adam, T., Arshad, M. K. M., Ruslinda, A. R., & Ramzan, M. A. (2015) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.754-755.854 · Cited by 12
“When starting a new project, using COMSOL helps you understand your problem [4,9]”
MethodLithographic resists as amazing compact imaging systems – A review
Okoroanyanwu, U. (2024) · Micro and Nano Engineering · doi:10.1016/j.mne.2024.100280 · Cited by 13
Surface-modified CMOS biosensors
Dehghandehnavi, F., Sajal, M., & Dandin, M. P. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1441430 · Cited by 12
Integrated freestanding single-crystal silicon nanowires: conductivity and surface treatment
Lee, C.-H., Ritz, C. S., Huang, M., Ziwisky, M., Blise, R. J., & Lagally, M. G. (2010) · Nanotechnology · doi:10.1088/0957-4484/22/5/055704 · Cited by 12
Resonant inelastic light scattering and photoluminescence in isolated nc-Si/SiO2 quantum dots
Bairamov, B. H., Toporov, V. V., Poloskin, E. D., Bairamov, H., Röder, C., Sprung, C., Bohmhammel, K., Seidel, J., Irmer, G., Lashkul, A. V., et al. (2013) · Semiconductors · doi:10.1134/s106378261302005x · Cited by 12
Molecular relaxation dynamics in organic monolayer junctions
Pleutin, S., Clément, N., Guérin, D., & Vuillaume, D. (2010) · Physical Review B · doi:10.1103/physrevb.82.125436 · Cited by 12
Study of parasitic resistance effects in nanowire and nanoribbon biosensors
Zeimpekis, I., Sun, K., Hu, C., Thomas, O., de Planque, M. R. R., Chong, H. M. H., Morgan, H., & Ashburn, P. (2015) · Nanoscale Research Letters · doi:10.1186/s11671-015-0794-6 · Cited by 12
“Stern E, Klemic JF, Routenberg DA, Wyrembak PN, Turner-Evans DB, Hamilton AD, et al. Label-free immunodetection with CMOS-compatible semiconducting nanowires.”
BackgroundBiotin-Streptavidin Sensitive BioFETs and Their Properties
Windbacher, T., Sverdlov, V. A., & Selberherr, S. (2010) · Communications in computer and information science · doi:10.1007/978-3-642-11721-3_6 · Cited by 13
“biotin-streptavidin [9,10,11,12], albumin [13], and transferrin [14].”
Intelligent Quantification of Picomolar Protein Concentration in Serum by Functionalized Nanopores
Das, N., Ray, R., Ray, S., & Roychaudhuri, C. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2872853 · Cited by 12
A Microcolumn DC Graphene Sensor for Rapid, Sensitive, and Universal Chemical Vapor Detection
Zang, W., Liu, Z., Kulkarni, G. S., Zhu, H., Wu, Y. S., Lee, K., Li, M. W.-H., Fan, X., & Zhong, Z. (2021) · Nano Letters · doi:10.1021/acs.nanolett.1c03416 · Cited by 13
Review of scaling effects on physical properties and practicalities of cantilever sensors
Yang, C.-K., van der Drift, E. W. J. M., & French, P. J. (2022) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ac8559 · Cited by 12
Design of a Double Cavity Nanotube Tunnel Field-Effect Transistor-based Biosenser
Gedam, A., Acharya, B., & Mishra, G. P. (2022) · ECS Journal of Solid State Science and Technology · doi:10.1149/2162-8777/ac8835 · Cited by 12
The detection of a transgenic soybean biochip using gold label silver stain technology
Deng, Z., Ge, Y. T., Cao, Q., & Han, K. L. (2011) · Bioorganic & Medicinal Chemistry Letters · doi:10.1016/j.bmcl.2011.07.037 · Cited by 12
Kandasamy, K., Marimuthu, M., Sung, G. Y., Ahn, C. G., & Kim, S. (2010) · Analytical Sciences · doi:10.2116/analsci.26.1215 · Cited by 12
Lehoucq, G., Bondavalli, P., Xavier, S., Legagneux, P., Abbyad, P., Baroud, C. N., & Pribat, D. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.01.054 · Cited by 12
Wu, H., Lee, W., Lin, C., & Chen, W. (2013) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2012.12.017 · Cited by 12
A novel SiNW/CMOS hybrid biosensor for high sensitivity/low noise
Lee, J., Hwang, S., Choi, B., Lee, J. H., Moon, D., Seol, M., Kim, C., Chung, I.-Y., Park, B., Choi, Y., et al. (2013) · Technical digest - International Electron Devices Meeting/Technical digest · doi:10.1109/iedm.2013.6724631 · Cited by 12
“Introduction Silicon nanowires (SiNWs) show outstanding potential in biosensor applications due to their high sensitivity, real-time label-free detection capabilities and low cost [1].”
BackgroundExternal-Noise-Induced Small-Signal Detection with Solution-Gated Carbon Nanotube Transistor
Hakamata, Y., Ohno, Y., Maehashi, K., Inoue, K., & Matsumoto, K. (2011) · Applied Physics Express · doi:10.1143/apex.4.045102 · Cited by 12
Nanodrähte in Chemo‐ und Biosensoren: aktueller Stand und Fahrplan für die Zukunft
Fennell, J. F., Liu, S. F., Azzarelli, J. M., Weis, J. G., Rochat, S., Mirica, K. A., Ravnsbæk, J. B., & Swager, T. M. (2015) · Angewandte Chemie · doi:10.1002/ange.201505308 · Cited by 12
AFM-based technologies as the way towards the reverse Avogadro number
Pleshakova, T. O., Shumov, I. D., Ivanov, Y. D., Malsagova, K. A., Kaysheva, A. L., & Archakov, A. I. (2015) · Biomeditsinskaya Khimiya · doi:10.18097/pbmc20156102239 · Cited by 12
Application of Carbon-Based Nanomaterials as Biosensor
Ray, S. C., & Jana, N. R. (2017) · Elsevier eBooks · doi:10.1016/b978-0-323-47906-6.00003-5 · Cited by 13
Application of nanocavity embedded dual metal double gate TFET in biomolecule detection
Noor, S. L., & Khan, M. Z. R. (2017) · IEEE Region Humanitarian Technology Conference · doi:10.1109/r10-htc.2017.8288971 · Cited by 13
“FET-based sensors have attracted researchers’ interest due to its advantages like miniaturization, standardization, and mass-production, dimensional compatibility with different biological species, high sensitivity and scope for real-time diagnosis [1]–[3].”
BackgroundNano-scale transistors for interfacing with brain: design criteria, progress and prospect
El‐Atab, N., Shaikh, S. F., & Hussain, M. M. (2019) · Nanotechnology · doi:10.1088/1361-6528/ab3534 · Cited by 13
“Another advantage of nanostructures is their small size which is of the same order of magnitude of the biological building blocks, as a result, this enables their seamless integration with cells and tissues and provides unique opportunities for biomedical applications [54-67].”
BackgroundMaeda, T., Kanamori, R., Choi, Y., Taki, M., Noda, T., Sawada, K., & Takahashi, K. (2022) · Sensors · doi:10.3390/s22041356 · Cited by 12
“Therefore, it is necessary to dilute the analyte by 10–10,000 fold for reducing the ionic strength [16,17].”
BackgroundBranched nanotrees with immobilized acetylcholine esterase for nanobiosensor applications
Risveden, K., Dick, K. A., Bhand, S., Rydberg, P., Samuelson, L., & Danielsson, B. R. G. (2009) · Nanotechnology · doi:10.1088/0957-4484/21/5/055102 · Cited by 13
Towards Nanowire (Bio) Sensors
Dawson, K., & O'Riordan, A. J. (2011) · Journal of Physics Conference Series · doi:10.1088/1742-6596/307/1/012004 · Cited by 12
Engineered multifunctional nanowires as novel biosensing tools for highly sensitive detection
Arora, P., Sindhu, A., Dilbaghi, N., & Chaudhury, A. (2012) · Applied Nanoscience · doi:10.1007/s13204-012-0142-4 · Cited by 14
“A third electrode known as the gate electrode (McAlpine et al. 2007; Stern et al. 2007) regulates the conductance between the source and the outer drainage of a semiconductor.”
BackgroundMolecular Modulation of Conductivity on H‐Terminated Silicon‐On‐Insulator Substrates
Dubey, G., Rosei, F., & Lopinski, G. P. (2010) · Small · doi:10.1002/smll.201001285 · Cited by 12
Biomolecule detection using a silicon nanoribbon: accumulation mode versus inversion mode
Elfström, N., & Linnros, J. (2008) · Nanotechnology · doi:10.1088/0957-4484/19/23/235201 · Cited by 12
Bae, T.-E., Jang, H., Lee, S., & Cho, W.-J. (2013) · Japanese Journal of Applied Physics · doi:10.7567/jjap.52.06gk03 · Cited by 12
Nanostructured biosensing platform—shadow edge lithography for high-throughput nanofabrication
Bai, J. G., Yeo, W., & Chung, J.-H. (2008) · Lab on a Chip · doi:10.1039/b811400e · Cited by 12
Geetha, B. T., Kumar, J. A., Arthy, M., Krithiga, T., Senthilkumar, G., Roomi, A. B., Shather, A. H., & Sillanpää, M. E. T. (2024) · Chemical Papers · doi:10.1007/s11696-024-03501-7 · Cited by 13
“The nanomembrane-based structure attracted the scientific community to the development of nanosensors (Stern et al. 2007).”
Contact behavior of focused ion beam deposited Pt on p-type Si nanowires
Ho, C. Y., Chiu, S. H., Ke, J. J., Tsai, K. T., Dai, Y.-A., Hsu, J.-F., Chang, M., & He, J. (2010) · Nanotechnology · doi:10.1088/0957-4484/21/13/134008 · Cited by 11
Biomolecule detection based on Si single-electron transistors for practical use
Nakajima, A., Kudo, T., & Furuse, S. (2013) · Applied Physics Letters · doi:10.1063/1.4816267 · Cited by 11
Lin, H., Kasai, N., Xu, N., Nakajima, H., Kato, S., Zeng, H., Lin, J., Mao, S., & Uchiyama, K. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114788 · Cited by 11
A review on H2 sensors based on FET
Guochao, Y. A. N., & Xiao, S. (2024) · Chinese Journal of Analytical Chemistry · doi:10.1016/j.cjac.2024.100401 · Cited by 12
Yadav, S., & Rewari, S. (2024) · Microsystem Technologies · doi:10.1007/s00542-024-05796-8 · Cited by 11
“…scalability, affordability, and compatibility with complementary metal-oxide-semiconductor (CMOS) technology, positions them as exemplary candidates for further integration with signal processing tools like system-on-chip (SoC) solutions (Im et al. 2007; Stern et al. 2007; Gao et al. 2010).”
Imaging surface charge distribution near carbon nanotube device in aqueous environments
Park, J., Son, B.-H., Park, J., Lee, S., & Ahn, Y. H. (2014) · Applied Physics Letters · doi:10.1063/1.4902401 · Cited by 11
A biristor based on a floating-body silicon nanowire for biosensor applications
Moon, D., Peycelon, M., Kim, J.-Y., Ahn, J., Park, T. J., & Choi, Y. (2013) · Applied Physics Letters · doi:10.1063/1.4789904 · Cited by 11
Silicon Field Effect Transistors as Dual-Use Sensor-Heater Hybrids
Reddy, B., Elibol, O. H., Nair, P. R., Dorvel, B. R., Butler, F., Ahsan, Z. S., Bergstrom, D. E., Alam, M. A., & Bashir, R. (2011) · Analytical Chemistry · doi:10.1021/ac102566f · Cited by 12
Routenberg, D. A., & Reed, M. A. (2009) · Lab on a Chip · doi:10.1039/b913912e · Cited by 11
Self-citationFernandes, P. G., Chapman, R. A., Seitz, O., Stiegler, H. J., Wen, H.-C., Chabal, Y. J., & Vogel, E. M. (2012) · IEEE Electron Device Letters · doi:10.1109/led.2011.2179115 · Cited by 13
“Finally, we use a pH sensing measurement to demonstrate that coupling allows for sensing experiments at lower operating voltages, an important factor in improving sensor reliability [3].”
BackgroundMethodInfluentialMacro modeling of ion sensitive field effect transistor with current drift
Kwon, D. W., Kim, S., Lee, R., Mo, H.-S., Kim, D. H., & Park, B. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.03.110 · Cited by 11
Detecting a Zeptogram of Pyridine with a Hybrid Plasmonic–Photonic Nanosensor
Proust, J., Martin, J., Gérard, D., Bijeon, J.-L., & Plain, J. (2019) · ACS Sensors · doi:10.1021/acssensors.8b01068 · Cited by 11
Ahn, C.-G., Ah, C. S., Kim, T., Park, C. W., Yang, J., Kim, A., & Sung, G. Y. (2010) · Applied Physics Letters · doi:10.1063/1.3486179 · Cited by 11
Impedance Modelling of FET-Based Biosensors
Shinwari, M. W., & Deen, M. J. (2011) · Journal of The Electrochemical Society · doi:10.1149/1.3579509 · Cited by 11
Sensitivity of silicon nanowires in biosensor applications
Elfström, N., & Linnros, J. (2008) · Journal of Physics Conference Series · doi:10.1088/1742-6596/100/5/052042 · Cited by 11
BioFET-SIM Web Interface: Implementation and Two Applications
Hediger, M. R., Jensen, J. H., & Vico, L. D. (2012) · PLoS ONE · doi:10.1371/journal.pone.0045379 · Cited by 11
“Currently, a large research effort is dedicated to the development and application of bionanosensors including pH measurement [1], protein sensing [2–5], DNA detection [6,7], blood analysis [8], nanotechnology based medicine [9], and the description of fundamental performance limits of these sensors”
BackgroundMultiscale modeling of fluctuations in stochastic elliptic PDE models of nanosensors
Heitzinger, C., & Ringhofer, C. A. (2013) · Communications in Mathematical Sciences · doi:10.4310/cms.2014.v12.n3.a1 · Cited by 11
“Recently, nanoscale field-effect biosensors [30, 31, 33, 36] and gas sensors [22, 25, 29, 34, 37] have been demonstrated experimentally.”
BackgroundVello, T. P., da Silva, L. M. B., da Silva, G. O., de Camargo, D. H. S., Corrêa, C. C., & Bufon, C. C. B. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.08.050 · Cited by 11
Nanowire platform for mapping neural circuits
Xie, C., & Cui, Y. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1000450107 · Cited by 12
Liu, Q., He, Y., Wang, Q., Min, S., Geng, H., Liu, Y., & Xu, T. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.118074 · Cited by 13
Mariello, M. (2026) · Advanced Sensor Research · doi:10.1002/adsr.202500111 · Cited by 11
Improving selectivity of ion-sensitive membrane by polyethylene glycol doping
Hu, Q., Chen, S., Wang, Z., & Zhang, Z. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.128955 · Cited by 10
Bhattacharjee, A., Nguyen, T. C., Pachauri, V., Ingebrandt, S., & Vu, X. T. (2020) · Micromachines · doi:10.3390/mi12010039 · Cited by 10
“The biomolecules of interest are detected by measuring the change in the threshold voltage [17–19] or the change in the drain-source current (IDS) [4,5,10] of the SiNW-FET device upon the binding to specific receptor molecules at the gate surface.”
BackgroundMuratore, C., Muratore, M. K., Austin, D., Miesle, P., Benton, A., Beagle, L. K., Motala, M. J., Moore, D. C., Slocik, J. M., Brothers, M. C., et al. (2022) · Advanced Materials Interfaces · doi:10.1002/admi.202102209 · Cited by 10
Defect-related energy structures of AlN nanotips probed by photoluminescence
Chen, H., Chen, G., Zhou, X., Zhu, W., Chen, X., & Zeng, X. (2011) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/44/50/505304 · Cited by 10
Electrokinetic effects on detection time of nanowire biosensor
Liu, Y., Guo, Q., Wang, S., & Hu, W. W. (2012) · Applied Physics Letters · doi:10.1063/1.3701721 · Cited by 10
DNA sequencing using polymerase substrate-binding kinetics
Previte, M. J. R., Zhou, C., Kellinger, M. W., Pantoja, R., Chen, C.-Y., Shi, J. P., Wang, B., Kia, A., Etchin, S., Vieceli, J., et al. (2015) · Nature Communications · doi:10.1038/ncomms6936 · Cited by 10
“It is also possible to use the intrinsic properties of the polymerase, such as charge and size, as the readout for label-free detection on a semiconductor sensor chip 24–26 .”
DNA hybridization assay at individual, biofunctionalized zinc oxide nanowires
Leiterer, C., Seise, B., Slowik, I., Brönstrup, G., Niepelt, R., Weber, K., Ronning, C., Christiansen, S. H., & Fritzsche, W. (2012) · Journal of Biophotonics · doi:10.1002/jbio.201200023 · Cited by 10
Detection of DNA of genetically modified maize by a silicon nanowire field-effect transistor
Pham, V. B., Pham, X. T. T., Dang, N. T. D., Le, T. T. T., Tran, P. D., Nguyen, T. C., Nguyen, V. Q., Dang, C. M., van Rijn, C. J. M., & Tong, D. H. (2011) · Advances in Natural Sciences Nanoscience and Nanotechnology · doi:10.1088/2043-6262/2/2/025010 · Cited by 10
AFM-based technologies as the way towards the reverse Avogadro number
Pleshakova, T. O., Shumov, I. D., Ivanov, Y. D., Malsagova, K. A., Kaysheva, A. L., & Archakov, A. I. (2015) · Biochemistry (Moscow) Supplement Series B Biomedical Chemistry · doi:10.1134/s1990750815030063 · Cited by 10
A Quantitative Relaxometric Version of the ELISA Test for the Measurement of Cell Surface Biomarkers
Alberti, D., Erve, M. V., Stefanìa, R., Ruggiero, M. R., Tapparo, M., Crich, S. G., & Aime, S. (2014) · Angewandte Chemie · doi:10.1002/ange.201310959 · Cited by 10
Wang, H., Liu, J., Wei, J., Xiao, K., Chen, Y., Jiang, Y.-L., & Wan, J. (2023) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2022.3233544 · Cited by 10
“Besides, since the Si technology is so mature that the electrolyte-gated Si BioFET is also studied [14].”
BackgroundIntegration of microfluidic sample delivery system on silicon nanowire-based biosensor
Hemmilä, S., Gao, A., Lü, N., Li, T., Wang, Y., & Kallio, P. J. (2014) · Microsystem Technologies · doi:10.1007/s00542-014-2076-0 · Cited by 10
Hu, X., Lv, G., Jia, Z., Jiang, J., Xiao, T., Yuan, M., & Tang, Y. (2011) · Applied Surface Science · doi:10.1016/j.apsusc.2011.05.088 · Cited by 10
Si nanowire ion-sensitive field-effect transistors with a shared floating gate
Nishiguchi, K., Clément, N., Yamaguchi, T., & Fujiwara, A. (2009) · Applied Physics Letters · doi:10.1063/1.3123002 · Cited by 10
Structure and morphology of polar and semi-polar pyramidal surfaces coating wurtzite ZnO micro-wires
Tang, D., Allard, L. F., Boley, A., Smith, D. J., & Liu, J. (2013) · Journal of Materials Science · doi:10.1007/s10853-013-7187-y · Cited by 10
Tuchinda, W., Enomoto, K., Sakurai, T., Padalkar, V. S., Cheng, H. L., Tang, M. T., Horio, A., Sakamaki, D., Omichi, M., Saeki, A., et al. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00070 · Cited by 10
Fabrication of a protein microarray by fluorous-fluorous interactions
Li, B.-Y., Juang, D. S., Adak, A. K., Hwang, K., & Lin, C. (2017) · Scientific Reports · doi:10.1038/s41598-017-07571-4 · Cited by 10
Nonlinear Chemical Sensitivity Enhancement of Nanowires in the Ultralow Concentration Regime
Lynall, D., Tseng, A., Nair, S. V., Savelyev, I. G., Blumin, M., Wang, S., Wang, Z., & Ruda, H. E. (2020) · ACS Nano · doi:10.1021/acsnano.9b08253 · Cited by 13
Chen, H.-Y., Lin, C., Chen, M., Huang, C.-C., & Chien, C.-H. (2011) · Japanese Journal of Applied Physics · doi:10.1143/jjap.50.04dl05 · Cited by 10
Addressable Nanowire Field-Effect-Transistor Biosensors With Local Backgates
Baek, D. J., Choi, S., Ahn, J., Kim, J.-Y., & Choi, Y. (2012) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2012.2201484 · Cited by 10
“(FET)-type biosensors have shown to be capable of detecting analyte molecules with high sensitivity and specificity [4]–[6].”
BackgroundOptimization of the response of nanowire biosensors
Naumova, O. V., & Fomin, B. I. (2016) · Optoelectronics Instrumentation and Data Processing · doi:10.3103/s8756699016050034 · Cited by 10
“In these sensors, any particle adsorbed on the NW surface acts as a local virtual gate, causing a change in the surface potential and, hence, conductivity of the NW [1, 2].”
BackgroundSub-femtomolar vertical graphene field effect immunosensor for detection of lung tumor markers
Liu, R., Song, H., Wu, H., Yang, Z., Fang, S., Zhu, J., & Ba, L. (2024) · Talanta · doi:10.1016/j.talanta.2024.126498 · Cited by 9
Ma, H., Chen, S., Zhang, X., Sun, T., Huo, P., Cui, X., Man, B., Yang, C., & Wei, D. (2024) · Nano Letters · doi:10.1021/acs.nanolett.4c03989 · Cited by 9
Gorla, S. R. K., & Pandey, C. K. (2024) · Micro and Nanostructures · doi:10.1016/j.micrna.2024.208060 · Cited by 9
Guha, S., & Chakrabarty, S. (2025) · Advances in Physics X · doi:10.1080/23746149.2024.2435278 · Cited by 23
Field Effect Transistor Nanosensor for Breast Cancer Diagnostics
Mohanty, P., Chen, Y., Wang, X., Hong, M. K., Rosenberg, C. L., Weaver, D. T., & Erramilli, S. (2012) · Series in sensors · doi:10.1201/b12138-53 · Cited by 9
“3 concentration, demonstrated here over a span of 17 U/ml to 2,200 U/ml, and underscores the broad dynamic range that is achievable, which has utility for both early stage diagnosis (low concentration) and later-stage prognosis and monitoring to treatment (high concentration) without…”
Kudo, T., & Nakajima, A. (2012) · Applied Physics Letters · doi:10.1063/1.3676664 · Cited by 9
Tunable nanowire Wheatstone bridge for improved sensitivity in molecular recognition
Maedler, C., Erramilli, S., House, L. J., Hong, M., & Mohanty, P. (2013) · Applied Physics Letters · doi:10.1063/1.4789994 · Cited by 9
Selecting the optimum engineering model for the frequency response of fcc nanowire resonators
Esfahani, M. N., Yilmaz, M., Sonne, M. R., Hattel, J. H., & Alaca, B. E. (2016) · Applied Mathematical Modelling · doi:10.1016/j.apm.2016.10.022 · Cited by 9
Nanobionics: From plant empowering to the infectious disease treatment
Hassanzadeh, P., Atyabi, F., & Dinarvand, R. (2022) · Journal of Controlled Release · doi:10.1016/j.jconrel.2022.07.028 · Cited by 9
Lale, A., Grappin, A., Lecestre, A., Mazenq, L., Launay, J., & Temple‐Boyer, P. (2022) · Thin Solid Films · doi:10.1016/j.tsf.2022.139609 · Cited by 9
Wenga, G., Jacques, E., Salaün, A., Rogel, R., Pichon, L., & Geneste, F. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.09.172 · Cited by 9
CMOS biosensor devices and applications
Reed, M. A. (2013) · Technical digest - International Electron Devices Meeting/Technical digest · doi:10.1109/iedm.2013.6724587 · Cited by 9
Self-citationFree-standing luminescent layers of porous silicon
Goryachev, D. N., Belyakov, L. V., & Sreseli, O. M. (2010) · Semiconductors · doi:10.1134/s1063782610120092 · Cited by 9
Highly sensitive ion detection using Si single-electron transistors
Takashi, K., & Nakajima, A. (2011) · Applied Physics Letters · doi:10.1063/1.3569148 · Cited by 9
Avalanche breakdown in surface modified silicon nanowires
Elfström, N., & Linnros, J. (2007) · Applied Physics Letters · doi:10.1063/1.2779110 · Cited by 9
Schottky Contacted Nanowire Field-Effect Sensing Device With Intrinsic Amplification
Shin, K.-S., Lee, K., Park, J. H., Kang, J. Y., & Chui, C. O. (2010) · IEEE Electron Device Letters · doi:10.1109/led.2010.2070833 · Cited by 9
Liu, H. H., Lin, T. H., & Sheu, J.-T. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.10.102 · Cited by 9
Semiconductor nanowire sensors
Neizvestny, I. G. (2009) · Russian Microelectronics · doi:10.1134/s1063739709040015 · Cited by 9
Nanoparticle-based biosensing using interfacial electrokinetic transduction
Crivellari, F., Mavrogiannis, N., & Gagnon, Z. R. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.09.029 · Cited by 9
50 nm Gate Length FinFET Biosensor & the Outlook for Single-Molecule Detection
Santermans, S., Barge, D., Hellings, G., Mori, C. A. B., Migacz, K. J., Rip, J., Spampinato, V., Vos, R., Bois, B. D., Chaudhuri, A. R., et al. (2020) · Technical digest - International Electron Devices Meeting/Technical digest · doi:10.1109/iedm13553.2020.9371908 · Cited by 9
Mechanistic Influence of Nanometer Length-Scale Surface Chemistry on DNA Hybridization
Das, P., & Zafar, S. (2015) · ACS Nano · doi:10.1021/acsnano.5b02530 · Cited by 9
“biosensors such as nanowire field effect transitor sensors.(27) 29 Hence, this biosensor is well suited for capturing details of a real time measurement curve.”
BackgroundA transport equation for confined structures derived from the Boltzmann equation
Heitzinger, C., & Ringhofer, C. A. (2011) · Communications in Mathematical Sciences · doi:10.4310/cms.2011.v9.n3.a8 · Cited by 9
“The applications in mind here are geometrically complex structures, such as ion channels with a large number of charges on the channel walls [4, 10, 12], nanowires for sensor applications [15, 13, 14, 9, 7, 6, 8], and nanopores.”
BackgroundRamadan, S., Bowen, L., Popescu, S., Fu, C., Kwa, K. S. K., & O'Neill, A. G. (2020) · Applied Surface Science · doi:10.1016/j.apsusc.2020.146516 · Cited by 11
Harika, P., Sravani, K. G., & Rao, K. S. (2023) · Devices for Integrated Circuit (DevIC) · doi:10.1109/devic57758.2023.10134925 · Cited by 8
Ghosh, R., Nelapati, R. P., Saha, P., Chinthaginjala, R., Kim, T.-H., & Kumar, S. (2024) · PLoS ONE · doi:10.1371/journal.pone.0301479 · Cited by 9
Cubells-Gómez, A., Lucío, M. I., Bañuls, M., & Maquieira, Á. (2024) · Talanta · doi:10.1016/j.talanta.2024.126563 · Cited by 9
Metadata
- Authors
- Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A.
- Affiliations
- Yale University (US)
- Corresponding author
- Fahmy, Tarek M.
- Reed, Mark A.
- Venue
- Nature
- Published
- 2007-02
- Volume
- 445
- Issue
- 7127
- Pages
- 519-522
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2077609143
- Cited by
- 1,352
- References
- 32
- Citations by year
- 2026: 17 · 2025: 19 · 2024: 37 · 2023: 29 · 2022: 32 · 2021: 49 · 2020: 51 · 2019: 47 · 2018: 58 · 2017: 49 · 2016: 86 · 2015: 92 · 2014: 93 · 2013: 118 · 2012: 124
- FWCI
- 76.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Nanowire Synthesis and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- semiconductor nanowires, field-effect transistor sensors, antibody detection, femtomolar sensitivity, pathogen detection, top-down nanowire fabrication, sensor integration
- MeSH terms
- Animals, Antibodies, Infections, Semiconductors, Sensitivity and Specificity, T-Lymphocytes, CD3 Complex, Mice, Nanowires
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.