Label-free immunodetection with CMOS-compatible semiconducting nanowires
The DOI matches its Crossref record; 31 of the 32 references it cites were found in a registry or an index.
Abstract
Semiconducting nanowires have the potential to function as highly sensitive and selective sensors for the label-free detection of low concentrations of pathogenic microorganisms. Successful solution-phase nanowire sensing has been demonstrated for ions, small molecules, proteins, DNA and viruses; however, 'bottom-up' nanowires (or similarly configured carbon nanotubes) used for these demonstrations require hybrid fabrication schemes, which result in severe integration issues that have hindered widespread application. Alternative 'top-down' fabrication methods of nanowire-like devices produce disappointing performance because of process-induced material and device degradation. Here we report an approach that uses complementary metal oxide semiconductor (CMOS) field effect transistor compatible technology and hence demonstrate the specific label-free detection of below 100 femtomolar concentrations of antibodies as well as real-time monitoring of the cellular immune response. This approach eliminates the need for hybrid methods and enables system-scale integration of these sensors with signal processing and information systems. Additionally, the ability to monitor antibody binding and sense the cellular immune response in real time with readily available technology should facilitate widespread diagnostic applications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,809
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Directed Assembly of One-Dimensional Nanostructures into Functional Networks
Huang, Y., Duan, X., Wei, Q., & Lieber, C. M. (2001) · Science · doi:10.1126/science.291.5504.630 · Cited by 2,199
Physics of semiconductor devices /2nd edition/
Sze, S. M. (1981) · New York eBooks · Cited by 1,599
Hahm, J.-I., & Lieber, C. M. (2004) · Nano Letters · doi:10.1021/nl034853b · Cited by 1,308
Electrical detection of single viruses
Patolsky, F., Zheng, G., Hayden, O., Lakadamyali, M., Zhuang, X., & Lieber, C. M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406159101 · Cited by 1,258
The Physics of Semi-Conductor Devices: D. A.Fraser Clarendon Press, Oxford, 1977; p. IX–148
Quaranta, A. A. (1979) · Il Nuovo Cimento B Series 11 · doi:10.1007/bf02743444 · Cited by 1,170
(1996) · Elsevier eBooks · doi:10.1016/b978-0-12-342335-1.x5000-3 · Cited by 1,016
Intermolecular and Surface Forces
(2011) · doi:10.1016/c2009-0-21560-1 · Cited by 871
Sequence-Specific Label-Free DNA Sensors Based on Silicon Nanowires
Li, Z., Chen, Y., Li, X., Kamins, T. I., Nauka, K., & Williams, R. S. (2004) · Nano Letters · doi:10.1021/nl034958e · Cited by 706
Cited by
Items 201–300 of 1,000
Wipf, M., Stoop, R. L., Tarasov, A., Bedner, K., Fu, W., Wright, I. A., Martin, C. J., Constable, E. C., Calame, M., & Schönenberger, C. (2013) · ACS Nano · doi:10.1021/nn401678u · Cited by 99
Chen, S., Bomer, J. G., van der Wiel, W. G., Carlen, E. T., & van den Berg, A. (2009) · ACS Nano · doi:10.1021/nn901220g · Cited by 100
“from void formation that has been reported for other masking layers.(11,19,20)”
BackgroundBiomolecular recognition with a sensitivity-enhanced nanowire transistor biosensor
Li, B., Chen, C.-W., Yang, W.-L., Lin, T., Pan, C., & Chen, Y. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.02.009 · Cited by 102
“…development of silicon nanowire FETs (SiNW-FETs), fabricated by both ‘‘bottom-up’’ (Lin et al., 2010; Patolsky et al., 2006) and ‘‘top-down’’ (Lin et al., 2009; Stern et al., 2007a) techniques, can take advantage of the processing techniques and mature fabrication methods of the silicon industry.”
BackgroundMethodQuantum Confinement Induced Performance Enhancement in Sub-5-nm Lithographic Si Nanowire Transistors
Trivedi, K., Yuk, H.-S., Floresca, H. C., Kim, M. J., & Hu, W. W. (2011) · Nano Letters · doi:10.1021/nl103278a · Cited by 97
The Smartest Materials: The Future of Nanoelectronics in Medicine
Cohen‐Karni, T., Langer, R., & Kohane, D. S. (2012) · ACS Nano · doi:10.1021/nn302915s · Cited by 99
25th Anniversary Article: Label‐Free Electrical Biodetection Using Carbon Nanostructures
Balasubramanian, K., & Kern, K. (2014) · Advanced Materials · doi:10.1002/adma.201304912 · Cited by 104
Challenges in the use of 1D nanostructures for on-chip biosensing and diagnostics: A review
Balasubramanian, K. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.07.041 · Cited by 99
“It has been proposed that he binding event must occur within the EDL of the nanowire or he nanotube in order to maximize sensitivity (Stern et al., 2007b). owever, it is difficult to realize immunosensors with immobilized ntibodies that can lie within the EDL in physiological buffers.”
BackgroundCohen‐Karni, T., Casanova, D., Cahoon, J. F., Qing, Q., Bell, D. C., & Lieber, C. M. (2012) · Nano Letters · doi:10.1021/nl3011337 · Cited by 96
Signal-to-Noise Ratio Enhancement of Silicon Nanowires Biosensor with Rolling Circle Amplification
Gao, A., Zou, N., Dai, P., Lü, N., Li, T., Wang, Y., Zhao, J., & Mao, H. (2013) · Nano Letters · doi:10.1021/nl401628y · Cited by 98
High mobility graphene ion-sensitive field-effect transistors by noncovalent functionalization
Fu, W., Nef, C., Tarasov, A., Wipf, M., Stoop, R. L., Knopfmacher, O., Weiss, M., Calame, M., & Schönenberger, C. (2013) · Nanoscale · doi:10.1039/c3nr03940d · Cited by 105
Design and Performance Assessment of Dielectrically Modulated Nanotube TFET Biosensor
Gedam, A., Acharya, B., & Mishra, G. P. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3080922 · Cited by 97
Yuan, Q., Zhou, Z., Zhuang, J., & Wang, X. (2010) · Chemistry of Materials · doi:10.1021/cm903844t · Cited by 95
Molecular Recognition and Specific Interactions for Biosensing Applications
Kim, D. C., & Kang, D. J. (2008) · Sensors · doi:10.3390/s8106605 · Cited by 91
“The use of nanowire or carbon nanotube (CNT) transistors as an active transducer in the fabrication of biosensors enabled the real-time detection of single viruses, small molecules, and proteins [136, 137].”
BackgroundMethodInfluentialZhang, G., Luo, Z. H. H., Huang, M. J., Tay, G. K. I., & Lim, E.-J. A. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.04.001 · Cited by 91
Optical Switching of Porphyrin-Coated Silicon Nanowire Field Effect Transistors
Winkelmann, C. B., Ionica, I., Chevalier, X., Royal, G., Bucher, C., & Bouchiat, V. (2007) · Nano Letters · doi:10.1021/nl0630485 · Cited by 89
den Hertog, M., Gonzalez-Posada, F., Songmuang, R., Rouvière, J., Fournier, T., Fernandez, B., & Monroy, E. (2012) · Nano Letters · doi:10.1021/nl302890f · Cited by 88
Li, K.-H., Fu, W. Y., & Choi, H. W. (2020) · Progress in Quantum Electronics · doi:10.1016/j.pquantelec.2020.100247 · Cited by 90
A reversible surface functionalized nanowire transistor to study protein–protein interactions
Lin, S., Pan, C., Tseng, K.-C., Lin, M.-C., Chen, C.-D., Tsai, C.-C., Yu, S.-H., Sun, Y., Lin, T., & Chen, Y. (2009) · Nano Today · doi:10.1016/j.nantod.2009.04.005 · Cited by 93
Dwivedi, P., & Kranti, A. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2640192 · Cited by 87
“A large difference between pH of the solution and the pI of the biomolecule increases the detection sensitivity [3].”
BackgroundRecent advances in gold nanostructures based biosensing and bioimaging
Zhang, Y., Wang, G., Lü, Y., Wang, F., & Liu, A. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2018.05.005 · Cited by 91
Selective ion sensors based on ionophore-modified graphene field-effect transistors
Maehashi, K., Sofue, Y., Okamoto, S., Ohno, Y., Inoue, K., & Matsumoto, K. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.09.033 · Cited by 87
Cheng, Y., Chen, K.-S., Meyer, N., Yuan, J. H., Hirst, L. S., Chase, P. B., & Xiong, P. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.05.019 · Cited by 93
“Electrical detection of a variety of physiologically important macromolecules including proteins (Stern et al., 2007; Zheng et al., 2005) and DNA (Bunimovich et al., 2006), macromolecular complexes such as viruses (Patolsky et al., 2004), and electrical signaling of neurons (Patolsky et al., 2006),…”
BackgroundGong, J. (2010) · Small · doi:10.1002/smll.200902132 · Cited by 87
Yang, Z., & Dou, X. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504846 · Cited by 91
Nanowire-Based Sensors for Biological and Medical Applications
Wang, Z., Lee, S., Koo, K.-I., & Kim, K. (2016) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2016.2528258 · Cited by 96
Planar Growth, Integration, and Applications of Semiconducting Nanowires
Sun, Y., Dong, T., Yu, L., Xu, J., & Chen, K. (2019) · Advanced Materials · doi:10.1002/adma.201903945 · Cited by 90
Microfluidic-integrated DNA nanobiosensors
Ansari, I. H., Hassan, S., Qurashi, A., & Khanday, F. A. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.05.009 · Cited by 86
Electrochemical nanobiosensing in whole blood: Recent advances
Hasanzadeh, M., & Shadjou, N. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.07.018 · Cited by 85
Su, J. (2017) · Sensors · doi:10.3390/s17030540 · Cited by 96
“Compared to other nanoscale sensors, such as nanowires [8], cantilevers [9], and plasmonic particles [10], WGM sensors have a larger effective capture area, thus making analyte detection events more likely.”
BackgroundZhang, J., Rupakula, M., Bellando, F., Garcia-Cordero, E., Longo, J., Wildhaber, F., Herment, G., Guérin, H., & Ionescu, A. M. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00597 · Cited by 87
Current nanotechnology advances in diagnostic biosensors
Barbosa, A. I., Rebelo, R., Reis, R. L., Bhattacharya, M., & Correlo, V. M. (2020) · Medical Devices & Sensors · doi:10.1002/mds3.10156 · Cited by 98
“Three independent SiNW biosensors with three different antibodies (PSA, carcinoembryonic antigen (CEA) and mucin-1) immobilized on them were developed (Stern et al., 2007).”
MethodSilicon nanowire circuits fabricated by AFM oxidation nanolithography
Martínez, R. V., Martı́nez, J., & Garcia, R. A. (2010) · Nanotechnology · doi:10.1088/0957-4484/21/24/245301 · Cited by 85
Kim, A., Ah, C. S., Park, C. W., Yang, J., Kim, T., Ahn, C.-G., Park, S. H., & Sung, G. Y. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.12.026 · Cited by 94
“When we used the reference buffer containing 100 M phoshate and 200 M NaCl, reproducible detection of 0.2 and 1.2 ng/mL EA concentrations was not performed due to insufficient Debye ength (7.3 nm) (Stern et al., 2007b).”
BackgroundMethodInfluentialKenry, K., & Lim, C. T. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2013.01.001 · Cited by 85
Zhang, G., Luo, Z. H. H., Huang, M. J., Ang, J. J., Kang, T. G., & Ji, H. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.07.007 · Cited by 83
“…has emerged as a promising device for sensitive and rapid detection of nucleic acids (Hahm and Lieber, 2004; Zhang et al., 2008a,b, 2009, 2010a,b), protein biomarkers (Chua et al., 2009; Lin et al., 2010; Stern et al., 2007; Zheng et al., 2005) and protein–DNA interactions (Zhang et al., 2010).”
BackgroundSarkar, A., Ghosh, A. B., Saha, N., Srivastava, D. N., Paul, P., & Adhikary, B. (2016) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2016.08.023 · Cited by 84
Sub-10-nm Nanochannels by Self-Sealing and Self-Limiting Atomic Layer Deposition
Nam, S., Lee, M., Lee, S., Lee, D.-J., Rossnagel, S. M., & Kim, K. B. (2010) · Nano Letters · doi:10.1021/nl100999e · Cited by 87
Periodically porous top electrodes on vertical nanowire arrays for highly sensitive gas detection
In, H. J., Field, C. R., & Pehrsson, P. E. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/35/355501 · Cited by 85
Flexible Sensory Platform Based on Oxide-based Neuromorphic Transistors
Liu, N., Zhu, L. Q., Feng, P., Wan, C., Liu, Y., Shi, Y., & Wan, Q. C. (2015) · Scientific Reports · doi:10.1038/srep18082 · Cited by 85
Multiple MoS2 Transistors for Sensing Molecule Interaction Kinetics
Nam, H., Oh, B.-R., Chen, P., Chen, M., Wi, S., Wan, W., Kurabayashi, K., & Liang, X. (2015) · Scientific Reports · doi:10.1038/srep10546 · Cited by 82
Machín, A., & Márquez, F. (2025) · Chemosensors · doi:10.3390/chemosensors13090345 · Cited by 89
A Highly Responsive Silicon Nanowire/Amplifier MOSFET Hybrid Biosensor
Lee, J., Jang, J., Choi, B., Yoon, J., Kim, J.-Y., Choi, Y., Kim, D. M., Kim, D. H., & Choi, S. (2015) · Scientific Reports · doi:10.1038/srep12286 · Cited by 80
Enhanced sensitivity of double gate junctionless transistor architecture for biosensing applications
Parihar, M. S., & Kranti, A. (2015) · Nanotechnology · doi:10.1088/0957-4484/26/14/145201 · Cited by 79
Probing Flow Velocity with Silicon Nanowire Sensors
Kim, D. R., Lee, C. H., & Zheng, X. (2009) · Nano Letters · doi:10.1021/nl900238a · Cited by 79
Nanowire Transistors: Physics of Devices and Materials in One Dimension
Colinge, J. P., & Greer, J. C. (2016) · Cambridge University Press eBooks · doi:10.1017/cbo9781107280779 · Cited by 89
Hydrogel Gate Graphene Field-Effect Transistors as Multiplexed Biosensors
Bay, H. H., Vo, R., Dai, X., Hsu, L. H. H., Mo, Z., Cao, S., Li, W., Omenetto, F. G., & Jiang, X. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b00431 · Cited by 78
Applications, techniques, and microfluidic interfacing for nanoscale biosensing
Kim, J., Junkin, M., Kim, D., Kwon, S., Shin, Y. S., Wong, P. K., & Gale, B. K. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0431-8 · Cited by 83
“Several research groups have already demonstrated the successful solution-phase SiNW sensing of DNA (Bunimovich et al. 2006), viruses (Patolsky et al. 2004), small molecules (Wang et al. 2005) and proteins (Stern et al. 2007a; Zheng et al. 2005).”
BackgroundMethodHigh-k dielectric Al2O3 nanowire and nanoplate field effect sensors for improved pH sensing
Reddy, B., Dorvel, B. R., Go, J., Nair, P. R., Elibol, O. H., Credo, G. M., Daniels, J. S., Chow, E. K. C., Su, X., Varma, M., et al. (2011) · Biomedical Microdevices · doi:10.1007/s10544-010-9497-z · Cited by 86
Choi, K., Kim, J.-Y., Ahn, J.-H., Choi, J.-M., Im, M., & Choi, Y.-K. (2012) · Lab on a Chip · doi:10.1039/c2lc21203j · Cited by 77
Shreya, S., Khan, A. H., Kumar, N., Amin, S. I., & Anand, S. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2944885 · Cited by 79
“ISFET, proposed by Befgveld [5] in 1970, was able to detect charged biomolecules but was inefficient in the detection of neutral biomolecules as well as inefficient with complementary metal oxide semiconductor (CMOS) [6].”
Ramos, D., Tamayo, J., Mertens, J., Calleja, M., Villanueva, L. G., & Zaballos, Á. (2007) · Nanotechnology · doi:10.1088/0957-4484/19/03/035503 · Cited by 77
Growth of Metal Oxide Nanowires from Supercooled Liquid Nanodroplets
Kim, M. H., Lee, B., Lee, S., Larson, C. E., Baik, J. M., Yavuz, C. T., Seifert, S., Vajda, Š., Winans, R. E., Moskovits, M., et al. (2009) · Nano Letters · doi:10.1021/nl902357q · Cited by 79
Lisowski, C. E., & Hutchison, J. E. (2009) · Analytical Chemistry · doi:10.1021/ac902271t · Cited by 76
Ultrasensitive detection of dopamine using a polysilicon nanowire field-effect transistor.
Lin, C.-H., Hsiao, C.-Y., Hung, C.-H., Lo, Y.-R., Lee, C.-C., Su, C.-J., Lin, H.-C., Ko, F.-H., Huang, T.-Y., & Yang, Y.-S. (2008) · Chemical Communications · doi:10.1039/b812968a · Cited by 69
Khan, H. U., Roberts, M. E., Knoll, W., & Bao, Z. (2011) · Chemistry of Materials · doi:10.1021/cm103685c · Cited by 76
Dastagir, T., Forzani, E., Zhang, R., Amlani, I., Nagahara, L. A., Tsui, R. K., & Tao, N. J. (2007) · The Analyst · doi:10.1039/b707025j · Cited by 76
Smart Surgical Catheter for C‐Reactive Protein Sensing Based on an Imperceptible Organic Transistor
Ji, X., Zhou, P., Zhong, L., Xu, A., Tsang, A. C. O., & Chan, P. K. L. (2018) · Advanced Science · doi:10.1002/advs.201701053 · Cited by 79
Label-free biosensing of a gene mutation using a silicon nanowire field-effect transistor
Wu, C.-C., Ko, F., Yang, Y., Hsia, D.-L., Lee, B.-S., & Su, T.-S. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.08.031 · Cited by 75
Regonda, S., Tian, R., Gao, J., Greene, S., Ding, J.-H., & Hu, W. W. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.01.027 · Cited by 75
Chung, I.-Y., Jang, H., Lee, J., Moon, H., Seo, S. M., & Kim, D. H. (2012) · Nanotechnology · doi:10.1088/0957-4484/23/6/065202 · Cited by 74
Tian, R., Regonda, S., Gao, J., Liu, Y., & Hu, W. W. (2011) · Lab on a Chip · doi:10.1039/c0lc00605j · Cited by 74
Chemiresistive nanosensors with convex/concave structures
Chen, S., Tang, Y., Zhan, K., Sun, D., & Hou, X. (2018) · Nano Today · doi:10.1016/j.nantod.2018.04.006 · Cited by 76
Zhao, W., Zhang, W., Chen, J., Li, H., Han, L. G., Li, X., Wang, J., Song, W., Xu, C., Cai, X., et al. (2024) · ACS Sensors · doi:10.1021/acssensors.4c00322 · Cited by 79
Control and stability of self-assembled monolayers under biosensing conditions
Seitz, O., Fernandes, P. G., Tian, R., Karnik, N., Wen, H.-C., Stiegler, H. J., Chapman, R. A., Vogel, E. M., & Chabal, Y. J. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm10132c · Cited by 72
Ultrasensitive Detection of Dual Cancer Biomarkers with Integrated CMOS-Compatible Nanowire Arrays
Lü, N., Gao, A., Dai, P., Mao, H., Zuo, X., Fan, C., Wang, Y., & Li, T. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01729 · Cited by 74
General surfactant-free synthesis of MTiO3 (M = Ba, Sr, Pb) perovskite nanostrips
Deng, H., Qiu, Y., & Yang, S. (2009) · Journal of Materials Chemistry · doi:10.1039/b815698k · Cited by 71
Advances in Nanowire Transistor‐Based Biosensors
Li, Q., Lü, N., Wang, L., & Fan, C. (2018) · Small Methods · doi:10.1002/smtd.201700263 · Cited by 73
Liu, Y.-C. C., Rieben, N., Iversen, L., Sørensen, B. S., Park, J., Nygård, J., & Martinez, K. L. (2010) · Nanotechnology · doi:10.1088/0957-4484/21/24/245105 · Cited by 74
Sakthivel, R., Kubendhiran, S., & Chen, S. (2019) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2019.02.013 · Cited by 70
Numerical Characterization and Optimization of the Microfluidics for Nanowire Biosensors
Kim, D. R., & Zheng, X. (2008) · Nano Letters · doi:10.1021/nl801559m · Cited by 70
Label-free Electronic Detection of the Antigen-Specific T-Cell Immune Response
Stern, E., Steenblock, E. R., Reed, M. A., & Fahmy, T. M. (2008) · Nano Letters · doi:10.1021/nl801693k · Cited by 70
Self-citationDielectric modulated junctionless biotube FET (DM-JL-BT-FET) Bio-Sensor
Goel, A., Rewari, S., Verma, S., Deswal, S. S., & Gupta, R. S. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3077540 · Cited by 69
Transport characterization in nanowires using an electrical nanoprobe
Talin, A. A., Léonard, F., Katzenmeyer, A. M., Swartzentruber, B. S., Picraux, S. T., Toimil‐Molares, M. E., Cederberg, J. G., Wang, X., Hersee, S. D., & Rishinaramangalum, A. (2010) · Semiconductor Science and Technology · doi:10.1088/0268-1242/25/2/024015 · Cited by 69
Action potentials of HL-1 cells recorded with silicon nanowire transistors
Eschermann, J. F., Stockmann, R., Hueske, M., Vu, X. T., Ingebrandt, S., & Offenhäusser, A. (2009) · Applied Physics Letters · doi:10.1063/1.3194138 · Cited by 76
Aroonyadet, N., Wang, X., Song, Y. L., Chen, H., Côté, R. J., Thompson, M. E., Datar, R. H., & Zhou, C. (2015) · Nano Letters · doi:10.1021/nl5047889 · Cited by 69
Direct, Label-Free, and Rapid Transistor-Based Immunodetection in Whole Serum
Gutiérrez‐Sanz, Ó., Andoy, N. M., Filipiak, M. S., Haustein, N., & Tarasov, A. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00187 · Cited by 71
Highly sensitive gas sensing platforms based on field effect Transistor-A review
Zhang, P., Xiao, Y., Zhang, J., Liu, B., Ma, X., & Wang, Y. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338575 · Cited by 73
Microfabricated Electrochemical Cell-Based Biosensors for Analysis of Living Cells In Vitro
Wang, J., Wu, C., Hu, N., Zhou, J., Du, L., & Wang, P. (2012) · Biosensors · doi:10.3390/bios2020127 · Cited by 69
“semiconductor sensor based on field-effect [47,48], a potential difference related to H concentration of the electrolyte arises on the insulator (Si3N4/SiO2)-solution interface.”
BackgroundTop‐down processed silicon nanowire transistor arrays for biosensing
Vu, X. T., Eschermann, J. F., Stockmann, R., Moulick, R. G., Offenhäusser, A., & Ingebrandt, S. (2009) · physica status solidi (a) · doi:10.1002/pssa.200880475 · Cited by 74
High-performance vertical hydrogen sensors using Pd-coated rough Si nanowires
Noh, J., Kim, H., Kim, B. S., Lee, E., Cho, H. H., & Lee, W. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm12701b · Cited by 67
Abouzar, M. H., Poghossian, A., Cherstvy, A. G., Pedraza, A. M., Ingebrandt, S., & Schöning, M. J. (2012) · physica status solidi (a) · doi:10.1002/pssa.201100710 · Cited by 70
Hybrid Integrated Label-Free Chemical and Biological Sensors
Mehrabani, S., Maker, A. J., & Armani, A. M. (2014) · Sensors · doi:10.3390/s140405890 · Cited by 77
“Using these methods, electrical sensors based on nanopores [20], nanowires [3,35,49,53,283,284] and carbon nanotubes [25,28,33,36,45,125,275,279] have been developed which can selectively detect low concentrations of analytes and even single molecules and viruses [20,43,283].”
MethodZhang, W., Hu, M., Liu, X., Wei, Y., Li, N., & Qin, Y. (2016) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2016.03.287 · Cited by 67
Li, J., Pud, S., Petrychuk, M. V., Offenhäusser, A., & Vitusevich, S. A. (2014) · Nano Letters · doi:10.1021/nl5010724 · Cited by 67
$\hbox{1}/f$ Noise of Silicon Nanowire BioFETs
Rajan, N. K., Routenberg, D. A., Chen, J., & Reed, M. A. (2010) · IEEE Electron Device Letters · doi:10.1109/led.2010.2047000 · Cited by 66
“However, efforts to fabricate such devices by top-down lithographic methods have often exhibited degraded electrical characteristics associated with the exposed silicon surfaces and high surface-to-volume ratios inherent in NW sensors [1]–[3].”
BackgroundSelf-citationPhotoconductivity in single AlN nanowires by subband gap excitation
Huang, H. M., Chen, R. S., Chen, H., Liu, T. W., Kuo, C. C., Chen, C. P., Hsu, H., Chen, L., Chen, K., & Yang, Y. J. (2010) · Applied Physics Letters · doi:10.1063/1.3292211 · Cited by 66
Zafar, S., D'Emic, C. P., Afzali, A., Fletcher, B. J., Zhu, Y., & Ning, T. H. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/40/405501 · Cited by 74
Light‐Induced Bipolar‐Resistance Effect Based on Metal–Oxide–Semiconductor Structures of Ti/SiO2/Si
Yu, C., & Wang, H. (2010) · Advanced Materials · doi:10.1002/adma.200903070 · Cited by 67
Nanowire-enabled bioelectronics
Zhang, A., Lee, J., & Lieber, C. M. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101135 · Cited by 71
Optimization of the Sensitivity of FET-Based Biosensors via Biasing and Surface Charge Engineering
Shoorideh, K., & Chui, C. O. (2012) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2012.2214221 · Cited by 65
“F IELD-EFFECT transistor (FET)-based biosensors have become one of the major technologies for detection of ions [1], [2], pH [2], [3], deoxyribonucleic acid (DNA) [4], proteins [2], [5], and other macromolecules in biologically relevant solutions.”
BackgroundPerformance limitations for nanowire/nanoribbon biosensors
Rajan, N. K., Duan, X., & Reed, M. A. (2013) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1235 · Cited by 75
Self-citationGiant Persistent Photoconductivity in Rough Silicon Nanomembranes
Feng, P., Mönch, I., Harazim, S. M., Huang, G., Mei, Y., & Schmidt, O. G. (2009) · Nano Letters · doi:10.1021/nl9016557 · Cited by 65
Wenga, G., Jacques, E., Salaün, A.-C., Rogel, R., Pichon, L., & Geneste, F. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.07.001 · Cited by 65
“Silicon nanowires have recently been developed as transducers for ultrasensitive biosensors and chemical sensors [Lin et al., 2009; Gao et al., 2007; Stern et al., 2007; Patolsky et al., 2006, Wu et al., 2009].”
BackgroundGao, A., Lü, N., Dai, P., Fan, C., Wang, Y., & Li, T. (2014) · Nanoscale · doi:10.1039/c4nr03210a · Cited by 64
Tan, F., Saucedo, N. M., Ramnani, P., & Mulchandani, A. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b01674 · Cited by 68
An impedance-based integrated biosensor for suspended DNA characterization
Ma, H., Wallbank, R. W. R., Chaji, R., Li, J., Suzuki, Y., Jiggins, C. D., & Nathan, A. (2013) · Scientific Reports · doi:10.1038/srep02730 · Cited by 67
Lin, S.-F., Wang, C., Ding, T.-J., Tsai, Y.-L., Yang, T., Chen, W., & Chang, J.-Y. (2012) · Optics Express · doi:10.1364/oe.20.014584 · Cited by 63
Chemical functionalisation of silicon and germanium nanowires
Collins, G., & Holmes, J. D. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm11028d · Cited by 70
Top down fabrication of long silicon nanowire devices by means of lateral oxidation
Pennelli, G. (2009) · Microelectronic Engineering · doi:10.1016/j.mee.2009.02.032 · Cited by 62
TiO2 Nanophotonic Sensors for Efficient Integrated Evanescent Raman Spectroscopy
Evans, C. C., Liu, C., & Suntivich, J. (2016) · ACS Photonics · doi:10.1021/acsphotonics.6b00314 · Cited by 72
Metadata
- Authors
- Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A.
- Affiliations
- Yale University (US)
- Corresponding author
- Fahmy, Tarek M.
- Reed, Mark A.
- Venue
- Nature
- Published
- 2007-02
- Volume
- 445
- Issue
- 7127
- Pages
- 519-522
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2077609143
- Cited by
- 1,352
- References
- 32
- Citations by year
- 2026: 17 · 2025: 19 · 2024: 37 · 2023: 29 · 2022: 32 · 2021: 49 · 2020: 51 · 2019: 47 · 2018: 58 · 2017: 49 · 2016: 86 · 2015: 92 · 2014: 93 · 2013: 118 · 2012: 124
- FWCI
- 76.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Nanowire Synthesis and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- semiconductor nanowires, field-effect transistor sensors, antibody detection, femtomolar sensitivity, pathogen detection, top-down nanowire fabrication, sensor integration
- MeSH terms
- Animals, Antibodies, Infections, Semiconductors, Sensitivity and Specificity, T-Lymphocytes, CD3 Complex, Mice, Nanowires
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.