Label-free immunodetection with CMOS-compatible semiconducting nanowires
The DOI matches its Crossref record; 31 of the 32 references it cites were found in a registry or an index.
Abstract
Semiconducting nanowires have the potential to function as highly sensitive and selective sensors for the label-free detection of low concentrations of pathogenic microorganisms. Successful solution-phase nanowire sensing has been demonstrated for ions, small molecules, proteins, DNA and viruses; however, 'bottom-up' nanowires (or similarly configured carbon nanotubes) used for these demonstrations require hybrid fabrication schemes, which result in severe integration issues that have hindered widespread application. Alternative 'top-down' fabrication methods of nanowire-like devices produce disappointing performance because of process-induced material and device degradation. Here we report an approach that uses complementary metal oxide semiconductor (CMOS) field effect transistor compatible technology and hence demonstrate the specific label-free detection of below 100 femtomolar concentrations of antibodies as well as real-time monitoring of the cellular immune response. This approach eliminates the need for hybrid methods and enables system-scale integration of these sensors with signal processing and information systems. Additionally, the ability to monitor antibody binding and sense the cellular immune response in real time with readily available technology should facilitate widespread diagnostic applications.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Nanowire Nanosensors for Highly Sensitive and Selective Detection of Biological and Chemical Species
Cui, Y., Wei, Q., Park, H., & Lieber, C. M. (2001) · Science · doi:10.1126/science.1062711 · Cited by 5,809
Multiplexed electrical detection of cancer markers with nanowire sensor arrays
Zheng, G., Patolsky, F., Cui, Y., Wang, W. U., & Lieber, C. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1138 · Cited by 2,436
Directed Assembly of One-Dimensional Nanostructures into Functional Networks
Huang, Y., Duan, X., Wei, Q., & Lieber, C. M. (2001) · Science · doi:10.1126/science.291.5504.630 · Cited by 2,199
Physics of semiconductor devices /2nd edition/
Sze, S. M. (1981) · New York eBooks · Cited by 1,599
Hahm, J.-I., & Lieber, C. M. (2004) · Nano Letters · doi:10.1021/nl034853b · Cited by 1,308
Electrical detection of single viruses
Patolsky, F., Zheng, G., Hayden, O., Lakadamyali, M., Zhuang, X., & Lieber, C. M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406159101 · Cited by 1,258
The Physics of Semi-Conductor Devices: D. A.Fraser Clarendon Press, Oxford, 1977; p. IX–148
Quaranta, A. A. (1979) · Il Nuovo Cimento B Series 11 · doi:10.1007/bf02743444 · Cited by 1,170
(1996) · Elsevier eBooks · doi:10.1016/b978-0-12-342335-1.x5000-3 · Cited by 1,016
Intermolecular and Surface Forces
(2011) · doi:10.1016/c2009-0-21560-1 · Cited by 871
Sequence-Specific Label-Free DNA Sensors Based on Silicon Nanowires
Li, Z., Chen, Y., Li, X., Kamins, T. I., Nauka, K., & Williams, R. S. (2004) · Nano Letters · doi:10.1021/nl034958e · Cited by 706
Cited by
Items 401–500 of 1,000
Ono, T., Oe, T., Kanai, Y., Ikuta, T., Ohno, Y., Maehashi, K., Inoue, K., Watanabe, Y., Nakakita, S., Suzuki, Y., et al. (2017) · Japanese Journal of Applied Physics · doi:10.7567/jjap.56.030302 · Cited by 44
Label-Free Electronic Detection of DNA Using Simple Double-Walled Carbon Nanotube Resistors
Dong, X., Fu, D., Xu, Y., Wei, J., Shi, Y., Chen, P., & Li, L. (2008) · The Journal of Physical Chemistry C · doi:10.1021/jp7121714 · Cited by 43
Asymmetric Doping in Silicon Nanostructures: The Impact of Surface Dangling Bonds
Hong, K., Kim, J., Lee, J. H., Shin, J., & Chung, U. (2010) · Nano Letters · doi:10.1021/nl904282v · Cited by 42
Quantifying signal changes in nano-wire based biosensors
Vico, L. D., Sørensen, M. H., Iversen, L., Rogers, D. M., Sørensen, B. S., Brandbyge, M., Nygård, J., Martinez, K. L., & Jensen, J. H. (2011) · Nanoscale · doi:10.1039/c0nr00442a · Cited by 47
Hierarchically Driven IrO2 Nanowire Electrocatalysts for Direct Sensing of Biomolecules
Shim, J. H., Lee, Y., Kang, M., Lee, J., Baik, J. M., Lee, Y., Lee, C., & Kim, M. H. (2012) · Analytical Chemistry · doi:10.1021/ac300573b · Cited by 43
Lü, N., Dai, P., Gao, A., Väliaho, J., Kallio, P. J., Wang, Y., & Li, T. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am505915y · Cited by 45
Nanowire gate all around-TFET-based biosensor by considering ambipolar transport
Reddy, N. N., & Panda, D. K. (2021) · Applied Physics A · doi:10.1007/s00339-021-04840-y · Cited by 48
Bionanoelectronics with 1D materials
Noy, A., Artyukhin, A. B., & Misra, N. (2009) · Materials Today · doi:10.1016/s1369-7021(09)70248-2 · Cited by 50
Peptide receptor-based selective dinitrotoluene detection using a microcantilever sensor
Hwang, K. S., Lee, M. H., Lee, J., Yeo, W., Lee, J. H., Kim, K.-M., Kang, J. Y., & Kim, T. S. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.09.021 · Cited by 42
Advances in field-effect biosensors towards point-of-use
Chen, S., & Bashir, R. (2023) · Nanotechnology · doi:10.1088/1361-6528/acf3f0 · Cited by 52
The memristive effect as a novelty in drug monitoring
Tzouvadaki, I., Aliakbarinodehi, N., Micheli, G. D., & Carrara, S. (2017) · Nanoscale · doi:10.1039/c7nr01297g · Cited by 41
Wu, T., Alharbi, A., You, K.-D., Kisslinger, K., Stach, E. A., & Shahrjerdi, D. (2017) · ACS Nano · doi:10.1021/acsnano.7b02986 · Cited by 44
Nanowire-based sensor electronics for chemical and biological applications
Zhang, G., Zeng, H., Liu, J., Nagashima, K., Takahashi, T., Hosomi, T., Tanaka, W., & Yanagida, T. (2021) · The Analyst · doi:10.1039/d1an01096d · Cited by 49
Choi, B., Ahn, J., Lee, J., Yoon, J., Lee, J., Jeon, M., Kim, D. M., Kim, D. H., Park, I., & Choi, S. (2015) · Solid-State Electronics · doi:10.1016/j.sse.2015.07.012 · Cited by 41
“Silicon nanowires (SiNWs) are being actively explored for various sensor applications, such as pH sensors [1,2], biosensors [1–3], vapor sensors [4], and gas sensors [5–7], because of the high sensitivity resulting from their high surface/volume ratio.”
BackgroundAccurate single-particle determination of the band gap in silicon nanowires
Rurali, R., Aradi, B., Frauenheim, T., & Gali, Á. (2007) · Physical Review B · doi:10.1103/physrevb.76.113303 · Cited by 41
Vico, L. D., Iversen, L., Sørensen, M. H., Brandbyge, M., Nygård, J., Martinez, K. L., & Jensen, J. H. (2011) · Nanoscale · doi:10.1039/c1nr10316d · Cited by 41
Micro- and nanodevices integrated with biomolecular probes
Alapan, Y., İçöz, K., & Gurkan, U. A. (2015) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.09.001 · Cited by 44
“By using silicon or indium oxide FETs, antibodies (Stern et al., 2007), ssDNA (Kim et al.”
Livi, P., Kwiat, M., Shadmani, A., Pevzner, A., Navarra, G., Rothe, J., Stettler, A., Chen, Y., Patolsky, F., & Hierlemann, A. R. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02604 · Cited by 42
Integration of biomolecules and nanomaterials: Towards highly selective and sensitive biosensors
Song, H. S., & Park, T. H. (2011) · Biotechnology Journal · doi:10.1002/biot.201100006 · Cited by 40
“On the other hand, top-down approaches using advanced lithographic technique for the fabrication of SiNW have been successfully demonstrated in recent reports [17, 18].”
MethodFabrication and application of a microfluidic‐embedded silicon nanowire biosensor chip
Vu, X. T., Stockmann, R., Wolfrum, B. L., Offenhäusser, A., & Ingebrandt, S. (2010) · physica status solidi (a) · doi:10.1002/pssa.200983316 · Cited by 43
Tarasov, A., Tsai, M., Flynn, E. M., Joiner, C. A., Taylor, R. C., & Vogel, E. M. (2015) · 2D Materials · doi:10.1088/2053-1583/2/4/044008 · Cited by 43
Silicon nanowire pH sensors fabricated with CMOS compatible sidewall mask technology
Zhou, K., Zhao, Z., Pan, L., & Wang, Z. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.09.114 · Cited by 40
Reversible Modulation of Spontaneous Emission by Strain in Silicon Nanowires
Shiri, D., Verma, A., Selvakumar, C. R., & Anantram, M. P. (2012) · Scientific Reports · doi:10.1038/srep00461 · Cited by 42
Rani, D., Pachauri, V., Mueller, A., Vu, X. T., Nguyen, T. C., & Ingebrandt, S. (2016) · ACS Omega · doi:10.1021/acsomega.6b00014 · Cited by 39
Application of nanotechnology in biosensors for enhancing pathogen detection
Sposito, A., Kurdekar, A. D., Zhao, J., & HEWLETT, I. K. (2018) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1512 · Cited by 44
Zhang, G., Huang, M. J., Luo, Z. H. H., Tay, G. K. I., Lim, E.-J. A., Liu, E. T., & Thomsen, J. S. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.07.129 · Cited by 39
Silicon-on-Glass Graphene-Functionalized Leaky Cavity Mode Nanophotonic Biosensor
Guo, Q., Zhu, H. H., Liu, F., Zhu, A. Y., Reed, J. C., Yi, F., & Cubukcu, E. (2014) · ACS Photonics · doi:10.1021/ph400073w · Cited by 39
Jo, G., Maeng, J., Kim, T., Hong, W., Choi, B.-S., & Lee, T. (2007) · Journal of Applied Physics · doi:10.1063/1.2799960 · Cited by 42
Micro- and nano-structure based oligonucleotide sensors
Ferrier, D. C., Shaver, M. P., & Hands, P. J. W. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.01.031 · Cited by 39
Chen, H., Zhao, X., Xi, Z., Zhang, Y., Li, H., Li, Z., Shi, H., Huang, L., Shen, R., Tao, J., et al. (2019) · International Journal of Nanomedicine · doi:10.2147/ijn.s198734 · Cited by 40
Signal Enhancement of Silicon Nanowire Field-Effect Transistor Immunosensors by RNA Aptamer
Vu, C.-A., Hu, W.-P., Yang, Y., Chan, H. W.-H., & Chen, W. (2019) · ACS Omega · doi:10.1021/acsomega.9b01264 · Cited by 39
Gao, A., Wang, Y., Zhang, D., He, Y., Zhang, L., Liu, Y., Wang, Y., Song, H., & Li, T. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.127762 · Cited by 39
Review—Thin-Film Transistors (TFTs) for Highly Sensitive Biosensing Applications: A Review
Kumar, A., Goyal, A. K., & Gupta, N. (2020) · ECS Journal of Solid State Science and Technology · doi:10.1149/2162-8777/abb2b3 · Cited by 46
Drain Current Model of a Four-Gate Dielectric Modulated MOSFET for Application as a Biosensor
Ajay, Narang, R., Saxena, M. K., & Gupta, M. (2015) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2015.2441753 · Cited by 39
Tsai, C., Chiang, P., Sun, C., Lin, T., Tsai, M., Chang, Y. C., & Chen, Y. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/13/135503 · Cited by 42
Atomic Layer Deposited Hafnium Oxide Gate Dielectrics for Charge-Based Biosensors
Chen, Y. W., Liu, M., Kaneko, T., & McIntyre, P. C. (2010) · Electrochemical and Solid-State Letters · doi:10.1149/1.3280224 · Cited by 38
Surface-modified silicon nano-channel for urea sensing
Chen, Y., Wang, X., Hong, M. K., Erramilli, S., & Mohanty, P. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.03.033 · Cited by 40
Automated nanomanipulation for nanodevice construction
Zhang, Y. L., Li, J., To, S., Zhang, Y., Ye, X., You, L., & Sun, Y. (2012) · Nanotechnology · doi:10.1088/0957-4484/23/6/065304 · Cited by 37
One‐Dimensional Nano‐Interconnection Formation
Ji, J., Zhou, Z., Yang, X., Zhang, W., Sang, S., & Li, P. (2013) · Small · doi:10.1002/smll.201201318 · Cited by 37
Probing the sensitivity of nanowire-based biosensors using liquid-gating
Lu, M.-P., Hsiao, C.-Y., Lai, W.-T., & Yang, Y. (2010) · Nanotechnology · doi:10.1088/0957-4484/21/42/425505 · Cited by 39
Ma, S., Li, X., Lee, Y.-K., & Zhang, A. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.05.061 · Cited by 40
“…2006; Gao et al., 2012; Hao et al., 2014; Ma et al., 2018; Xie et al., 2012; Zhang et al., 2008), protein detection (Elfström et al., 2008; Hakim et al., 2012; Hu et al., 2016; Kumar M et al., 2011; Selvanayagam et al., 2002; Stern et al., 2007; Yacoub-George et al., 1996; Yu et al., 2013), etc.”
BackgroundSilicon Nanoribbon pH Sensors Protected by a Barrier Membrane with Carbon Nanotube Porins
Chen, X., Zhang, H., Tunuguntla, R. H., & Noy, A. (2018) · Nano Letters · doi:10.1021/acs.nanolett.8b02898 · Cited by 38
Nanosensors in biomedical and environmental applications: Perspectives and prospects
Rabbani, M., Hoque, M. E., & Mahbub, Z. B. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-820702-4.00007-6 · Cited by 48
Dielectric‐Modulated Biosensing with Ultrahigh‐Frequency‐Operated Graphene Field‐Effect Transistors
Zhang, X., Liu, T., Boyle, A. L., Bahreman, A., Bao, L., Jing, Q., Xue, H., Kieltyka, R. E., Kros, A., Schneider, G. F., et al. (2022) · Advanced Materials · doi:10.1002/adma.202106666 · Cited by 43
Liu, W., Chen, L., Yin, D., Yang, Z., Feng, J., Sun, Q., Lai, L., & Guo, X. (2023) · Nature Communications · doi:10.1038/s41467-023-41018-x · Cited by 39
Buitrago, E., Fernández-Bolaños, M., Rigante, S., Zilch, C. F., Schröter, N. S., Nightingale, A. M., & Ionescu, A. M. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.11.123 · Cited by 37
Modeling and simulation of field-effect biosensors (BioFETs) and their deployment on the nanoHUB
Heitzinger, C., Kennell, R., Klimeck, G., Mauser, N. J., McLennan, M. J., & Ringhofer, C. A. (2008) · Journal of Physics Conference Series · doi:10.1088/1742-6596/107/1/012004 · Cited by 37
“Conductance simulations of nanowire sensors with different diameters provide numerical evidence for the importance of the dipole moment of the biofunctionalized surface layer in addition to its surface charge.”
BackgroundTCAD-Based Simulation Method for the Electrolyte–Insulator–Semiconductor Field-Effect Transistor
Choi, B., Lee, J., Yoon, J., Ahn, J., Park, T. J., Kim, D. M., Kim, D. H., & Choi, S. (2015) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2015.2395875 · Cited by 37
“Many research groups have attempted to obtain significant experimental results on various types of EISFET-based biosensors [2] and to beat the Nernst limit as well [3].”
BackgroundLiu, N., Liu, Y., Feng, P., Zhu, L. Q., Shi, Y., & Wan, Q. C. (2015) · Applied Physics Letters · doi:10.1063/1.4913445 · Cited by 39
Detection of marker miRNAs in plasma using SOI-NW biosensor
Ivanov, Y. D., Pleshakova, T. O., Malsagova, K. A., Kozlov, A. F., Kaysheva, A. L., Shumov, I. D., Galiullin, R. A., Kurbatov, L. K., Popov, V. P., Naumova, O. V., et al. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.01.153 · Cited by 38
Harika, P., Sravani, K. G., Rao, K. S., & Lay-Ekuakille, A. (2024) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2024.3386586 · Cited by 38
Graphene field-effect transistors: the road to bioelectronics
Donnelly, M. J., Mao, D., Park, J., & Xu, G. (2018) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/aadcca · Cited by 38
Electrically nanowired-enzymes for probe modification and sensor fabrication
Bagal-Kestwal, D., Pan, M. H., & Chiang, B. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.09.018 · Cited by 37
Dwivedi, P., & Singh, R. K. (2020) · Engineering Research Express · doi:10.1088/2631-8695/ab9bf0 · Cited by 39
Su, Q., Xu, P., Zhou, L., Wu, F., Dong, A., Wan, Y., & Qian, W. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c10926 · Cited by 36
Single-Electron-Resolution Electrometer Based on Field-Effect Transistor
Nishiguchi, K., Koechlin, C., Ono, Y., Fujiwara, A., Inokawa, H., & Yamaguchi, H. (2008) · Japanese Journal of Applied Physics · doi:10.1143/jjap.47.8305 · Cited by 36
Vacic, A., Criscione, J. M., STERN, E. W., Rajan, N. K., Fahmy, T. M., & Reed, M. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.07.025 · Cited by 36
“Bonded chips integrated with a fluidic mixing chamber (Stern et al., 2007) were functionalized with CA15.”
MethodSelf-citationHan, Q., Sun, S., Sun, D., Zhu, J., & Wang, X. (2011) · RSC Advances · doi:10.1039/c1ra00379h · Cited by 36
Hu, C., Zeimpekis, I., Sun, K., Anderson, S., Ashburn, P., & Morgan, H. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b00702 · Cited by 37
Applications of Nanowire Arrays in Nanomedicine
Berthing, T., Sørensen, C. B., Nygård, J., & Martinez, K. L. (2009) · Journal of Nanoneuroscience · doi:10.1166/jns.2009.001 · Cited by 39
Label-free SnO 2 nanowire FET biosensor for protein detection
Jakob, M. H., Dong, B., Gutsch, S., Chatelle, C. V., Krishnaraja, A., Weber, W., & Zacharias, M. (2017) · Nanotechnology · doi:10.1088/1361-6528/aa7015 · Cited by 38
Tunable diameter electrostatically formed nanowire for high sensitivity gas sensing
Henning, A., Swaminathan, N., Godkin, A., Shalev, G., Amit, I., & Rosenwaks, Y. (2015) · Nano Research · doi:10.1007/s12274-015-0730-1 · Cited by 36
“3 [19,20], it involves the use of sophisticated”
BackgroundRecent Advances in AIV Biosensors Composed of Nanobio Hybrid Material
Lee, T., Ahn, J., Park, S. Y., Kim, G., Kim, J., Kim, T. P., Nam, I., Park, C., & Lee, M. (2018) · Micromachines · doi:10.3390/mi9120651 · Cited by 35
“The electrical detection of biomolecules including AIVs with field-effect transistors (FETs) provides several advantages: high sensitivity in the pico-and femtomolar range, ease of use based on the label-free technique, portability due to the compact sizes of sensors and readout circuits, and low-cost mass production…”
BackgroundWoo, K., Kang, W., Lee, K., Lee, P., Kim, Y., Yoon, T., Cho, C., Park, K., Ha, M.-W., & Lee, H. H. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112186 · Cited by 35
Abdurhman, A. A. M., Zhang, Y., Zhang, G., & Wang, S. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-8989-3 · Cited by 37
Alexander, F. A., Price, D. T., & Bhansali, S. (2012) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2012.2222023 · Cited by 40
Silicon nanowire sensor for gas detection fabricated by nanoimprint on SU8/SiO2/PMMA trilayer
Wan, J., Deng, S., Yang, R., Shu, Z., Lu, B.-R., Xie, S., Chen, Y., Huq, E., Liu, R., & Qu, X.-P. (2008) · Microelectronic Engineering · doi:10.1016/j.mee.2008.12.022 · Cited by 46
Silicon nanowire based single-molecule SERS sensor
Wang, H., Han, X., Ou, X., Lee, C., Zhang, X., & Lee, S. (2013) · Nanoscale · doi:10.1039/c3nr01879b · Cited by 35
Towards in vitro molecular diagnostics using nanostructures
Kurkina, T., & Balasubramanian, K. (2011) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-011-0855-7 · Cited by 37
Yen, P.-W., Huang, C.-W., Yu-Jie, H., Chen, M., Liao, H.-H., Lu, S., & Chih-Ting, L. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.05.010 · Cited by 35
“…nanowire (SiNW) field-effect sensor has attracted substantial attentions because of its ultra-high sensitivity for different biological molecules, such as viruses, DNA/miRNA, proteins, and antibodies (He et al. 2008; Patolsky et al. 2007; Patolsky et al. 2004; Stern et al. 2007; Stern et al. 2010).”
BackgroundA graphene field-effect capacitor sensor in electrolyte
Chen, S., Zhang, Z., Ma, L., Ahlberg, P., Gao, X., Qiu, Z., Wu, D., Ren, W., Cheng, H., & Zhang, S. (2012) · Applied Physics Letters · doi:10.1063/1.4759147 · Cited by 40
Observation of Space-Charge-Limited Transport in InAs Nanowires
Katzenmeyer, A. M., Léonard, F., Talin, A. A., Toimil‐Molares, M. E., Cederberg, J. G., Huang, J., & Lensch-Falk, J. L. (2010) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2010.2062198 · Cited by 35
“their basic electrical characteristics have to be measured accurately and reproducibly; however, bulk techniques such as Hall measurements cannot be easily [1] implemented with NWs due to the small dimensions.”
BackgroundSensitivity Limits and Scaling of Bioelectronic Graphene Transducers
Cheng, Z., Hou, J., Zhou, Q., Li, T., Li, H., Yang, L., Jiang, K., Wang, C., Li, Y., & Fang, Y. Z. (2013) · Nano Letters · doi:10.1021/nl401276n · Cited by 38
Imaging Ultrafast Carrier Transport in Nanoscale Field-Effect Transistors
Son, B. H., Park, J., Hong, J. T., Park, J., Lee, S., & Ahn, Y. H. (2014) · ACS Nano · doi:10.1021/nn5042619 · Cited by 37
Noise spectroscopy as an equilibrium analysis tool for highly sensitive electrical biosensing
Guo, Q., Kong, T., Su, R., Zhang, Q., & Cheng, G. (2012) · Applied Physics Letters · doi:10.1063/1.4748931 · Cited by 34
Hydrogen sensing properties of Pt/Pd bimetal decorated on highly hydrophobic Si nanowires
Hassan, K., Uddin, A. S. M. I., & Chung, G. (2016) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2016.04.124 · Cited by 34
Multiplexed Silicon Nanowire Tunnel FET-Based Biosensors With Optimized Multi-Sensing Currents
Kim, S., Lee, R., Kwon, D., Kim, T., Park, T. J., Choi, S., Mo, H.-S., Kim, D. H., & Park, B. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3054052 · Cited by 34
“Thereafter, several researchers have demonstrated the nanowire biosensors by utilizing top-down processes [9]–[21].”
BackgroundCherik, I. C., & Mohammadi, S. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3163475 · Cited by 34
Fringe-fields-modulated double-gate tunnel-FET biosensor
Cherik, I. C., & Mohammadi, S. (2024) · Scientific Reports · doi:10.1038/s41598-023-50723-y · Cited by 38
Applications of Zero-Valent Silicon Nanostructures in Biomedicine
Kafshgari, M. H., Voelcker, N. H., & Harding, F. J. (2015) · Nanomedicine · doi:10.2217/nnm.15.91 · Cited by 34
Rajan, N. K., Routenberg, D. A., Chen, J., & Reed, M. A. (2010) · Applied Physics Letters · doi:10.1063/1.3526382 · Cited by 34
Self-citationAccumulation mode field-effect transistors for improved sensitivity in nanowire-based biosensors
Baek, D. J., Duarte, J. P., Moon, D., Kim, C., Ahn, J., & Choi, Y. (2012) · Applied Physics Letters · doi:10.1063/1.4723843 · Cited by 34
Schroth, P., Köhl, M., Hornung, J.-W., Dimakis, E., Somaschini, C., Geelhaar, L., Biermanns, A., Bauer, S., Lazarev, S., Pietsch, U., et al. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.055504 · Cited by 36
Chen, D., Xu, T., Dou, Y., & Li, T. (2024) · ACS Nano · doi:10.1021/acsnano.4c01937 · Cited by 36
Performance Analysis of Si Nanowire Biosensor by Numerical Modeling for Charge Sensing
Yang, X., Frensley, W. R., Zhou, D., & Hu, W. W. (2011) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2011.2178101 · Cited by 33
“To mitigate process induced performance variation, SiNW or nanoribbon fabricated on silicon-on-insulator (SOI) substrate by lithography, similar to finFETs without top-gate, have often been chosen in favor of its CMOS compatible processing techniques [2], [6], [7], [12].”
BackgroundMethodPolyelectrolyte multilayer electrostatic gating of graphene field-effect transistors
Wang, Y. Y., & Burke, P. J. (2014) · Nano Research · doi:10.1007/s12274-014-0525-9 · Cited by 33
Jiang, F., Liu, J., Li, Y., Fan, L., Ding, Y., & Li, Y. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201102800 · Cited by 33
Optical Regulation of Protein Adsorption and Cell Adhesion by Photoresponsive GaN Nanowires
Li, J., Han, Q., Zhang, Y., Zhang, W., Dong, M., Besenbacher, F., Yang, R., & Wang, C. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am403070g · Cited by 35
Malsagova, K. A., Pleshakova, T. O., Galiullin, R. A., Shumov, I. D., Kozlov, A. F., Romanova, T. S., Popov, V. P., Glukhov, A. V., Konev, V. A., Archakov, A. I., et al. (2020) · Coatings · doi:10.3390/coatings10080753 · Cited by 33
Optimization of nanowire DNA sensor sensitivity using self-consistent simulation
Baumgartner, S., Vasicek, M., Bulyha, A., & Heitzinger, C. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/42/425503 · Cited by 39
Logic inverters composed of controlled depletion-mode and enhancement-mode ZnO nanowire transistors
Jo, G., Hong, W., Maeng, J., Choe, M., Park, W., & Lee, T. (2009) · Applied Physics Letters · doi:10.1063/1.3127514 · Cited by 33
CMOS Cell Sensors for Point-of-Care Diagnostics
Adıgüzel, Y., & Külah, H. (2012) · Sensors · doi:10.3390/s120810042 · Cited by 33
“Stern and co-workers [94] fabricated silicon nanowires with a CMOS-compatible technology, and performed label-free immunodetection of mouse immunoglobulins G and A, at sub-100 fM levels, as”
Chemiresistors based on ultrathin gold nanowires for sensing halides, pyridine and dopamine
Muratova, I. S., Mikhelson, K. N., Ermolenko, Y. Е., Offenhäusser, A., & Mourzina, Y. G. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.03.151 · Cited by 33
Nanoelectronic Heterodyne Sensor: A New Electronic Sensing Paradigm
Kulkarni, G. S., Zang, W., & Zhong, Z. (2016) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00329 · Cited by 32
Detection of the Early Stage of Recombinational DNA Repair by Silicon Nanowire Transistors
Chiesa, M., Cárdenas, P. P., Otón, F., Martı́nez, J., Mas‐Torrent, M., García, F., Alonso, J. C., Rovira, C., & Garcia, R. A. (2012) · Nano Letters · doi:10.1021/nl2037547 · Cited by 32
Biosensing using photonic crystal nanolasers
Baba, T. (2015) · MRS Communications · doi:10.1557/mrc.2015.73 · Cited by 32
Formation of oxides on CoCrMo surfaces at room temperature: An XPS study
Badovinac, I. J., Piltaver, I. K., Peter, R., Šarić, I., & Petravić, M. (2018) · Applied Surface Science · doi:10.1016/j.apsusc.2018.12.004 · Cited by 32
Rollo, S., Rani, D., Leturcq, R., Olthuis, W., & García, C. P. (2019) · Nano Letters · doi:10.1021/acs.nanolett.8b04988 · Cited by 32
“e (hemicylindrical), which results in a much faster adsorption of analytes[7, 8, 9]. SiNWs have shown low limits of detection for different biomarkers comprising DNA [10, 11, 12, 13, 14] and proteins [2, 15, 16, 17] in different media including biological fluids [18, 19, 20, 21] and tissues [22, 23]. Owing to the well…”
BackgroundConductometric Sensing with Individual InAs Nanowires
Demontis, V., Rocci, M., Donarelli, M., Maiti, R., Zannier, V., Beltram, F., Sorba, L., Roddaro, S., Rossella, F., & Baratto, C. (2019) · Sensors · doi:10.3390/s19132994 · Cited by 34
Kim, H.-G., Yun, J., Gao, M., Kim, H., Cho, M., & Park, I. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c10785 · Cited by 32
Metadata
- Authors
- Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A.
- Affiliations
- Yale University (US)
- Corresponding author
- Fahmy, Tarek M.
- Reed, Mark A.
- Venue
- Nature
- Published
- 2007-02
- Volume
- 445
- Issue
- 7127
- Pages
- 519-522
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2077609143
- Cited by
- 1,352
- References
- 32
- Citations by year
- 2026: 17 · 2025: 19 · 2024: 37 · 2023: 29 · 2022: 32 · 2021: 49 · 2020: 51 · 2019: 47 · 2018: 58 · 2017: 49 · 2016: 86 · 2015: 92 · 2014: 93 · 2013: 118 · 2012: 124
- FWCI
- 76.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Nanowire Synthesis and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- semiconductor nanowires, field-effect transistor sensors, antibody detection, femtomolar sensitivity, pathogen detection, top-down nanowire fabrication, sensor integration
- MeSH terms
- Animals, Antibodies, Infections, Semiconductors, Sensitivity and Specificity, T-Lymphocytes, CD3 Complex, Mice, Nanowires
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.