Restoration of grasp following paralysis through brain-controlled stimulation of muscles
Open accessAbstract
Patients with spinal cord injury lack the connections between brain and spinal cord circuits that are essential for voluntary movement. Clinical systems that achieve muscle contraction through functional electrical stimulation (FES) have proven to be effective in allowing patients with tetraplegia to regain control of hand movements and to achieve a greater measure of independence in daily activities. In existing clinical systems, the patient uses residual proximal limb movements to trigger pre-programmed stimulation that causes the paralysed muscles to contract, allowing use of one or two basic grasps. Instead, we have developed an FES system in primates that is controlled by recordings made from microelectrodes permanently implanted in the brain. We simulated some of the effects of the paralysis caused by C5 or C6 spinal cord injury by injecting rhesus monkeys with a local anaesthetic to block the median and ulnar nerves at the elbow. Then, using recordings from approximately 100 neurons in the motor cortex, we predicted the intended activity of several of the paralysed muscles, and used these predictions to control the intensity of stimulation of the same muscles. This process essentially bypassed the spinal cord, restoring to the monkeys voluntary control of their paralysed muscles. This achievement is a major advance towards similar restoration of hand function in human patients through brain-controlled FES. We anticipate that in human patients, this neuroprosthesis would allow much more flexible and dexterous use of the hand than is possible with existing FES systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“CNS-based neuroprostheses, or brain–machine interfaces (BMIs), are systems whereby neural electrical activities are decoded and used to control robotic limbs [76, 89, 105] or to stimulate muscles for restoring limb function [35].”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [35]
In the citing paper
“Currently, all reported BMI experiments with human patients [26, 35, 57, 58, 150] require the subjects tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [35]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Targeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094
McDonald, J. W., & Sadowsky, C. L. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07603-1 · Cited by 1,858
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Relation of pyramidal tract activity to force exerted during voluntary movement.
Evarts, E. V. (1968) · Journal of Neurophysiology · doi:10.1152/jn.1968.31.1.14 · Cited by 1,258
Direct control of paralysed muscles by cortical neurons
Moritz, C. T., Perlmutter, S. I., & Fetz, E. E. (2008) · Nature · doi:10.1038/nature07418 · Cited by 610
Spasticity after spinal cord injury
Adams, M. M., & Hicks, A. L. (2005) · Spinal Cord · doi:10.1038/sj.sc.3101757 · Cited by 517
Motor and sensory recovery following incomplete tetraplegia
Waters, R. L., Adkins, R. H., Yakura, J. S., & Sie, I. H. (1994) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/0003-9993(94)90034-5 · Cited by 438
Predicting Measures of Motor Performance from Multiple Cortical Spike Trains
Humphrey, D. R., Schmidt, E. M., & Thompson, W. (1970) · Science · doi:10.1126/science.170.3959.758 · Cited by 372
Peckham, P. H., Keith, M. W., Kilgore, K. L., Grill, J. H., Wuolle, K. S., Thrope, G. B., Gorman, P., Hobby, J., Mulcahey, M. J., Carroll, S., et al. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.25910 · Cited by 319
Implantable functional neuromuscular stimulation in the tetraplegic hand
Keith, M. W., Peckham, P. H., Thrope, G. B., Stroh, K. C., Smith, B., Buckett, J. R., Kilgore, K. L., & Jatich, J. W. (1989) · The Journal Of Hand Surgery · doi:10.1016/s0363-5023(89)80017-6 · Cited by 212
Flagged first, then by citations
Cited by
Sorted by citations
Items 101–200 of 480
Animal models of axon regeneration after spinal cord injury
Lee, D.-H., & Lee, J. K. (2013) · Neuroscience Bulletin · doi:10.1007/s12264-013-1365-4 · Cited by 63
Intraspinal microstimulation produces over-ground walking in anesthetized cats
Holinski, B. J., Mazurek, K. A., Everaert, D. G., Toossi, A., Lucas‐Osma, A. M., Troyk, P. R., Etienne‐Cummings, R., Stein, R. B., & Mushahwar, V. K. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056016 · Cited by 63
A muscle-activity-dependent gain between motor cortex and EMG
Naufel, S. N., Glaser, J. I., Kording, K. P., Perreault, E. J., & Miller, L. E. (2018) · Journal of Neurophysiology · doi:10.1152/jn.00329.2018 · Cited by 64
Self-citationRao, R. P. N. (2019) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2019.03.008 · Cited by 63
Intrafascicular peripheral nerve stimulation produces fine functional hand movements in primates
Badi, M., Wurth, S. M., Scarpato, I., Roussinova, E., Losanno, E., Bogaard, A. R., Delacombaz, M., Borgognon, S., Čvančara, P., Fallegger, F., et al. (2021) · Science Translational Medicine · doi:10.1126/scitranslmed.abg6463 · Cited by 62
A High-Performance Keyboard Neural Prosthesis Enabled by Task Optimization
Nuyujukian, P., Fan, J. M., Kao, J. C., Ryu, S. I., & Shenoy, K. V. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2354697 · Cited by 61
Pizzolato, C., Gunduz, M. A., Palipana, D. B., Wu, J., Grant, G. D., Hall, S., Dennison, R., ZAFONTE, R. D., Lloyd, D. G., & Teng, Y. D. (2021) · Experimental Neurology · doi:10.1016/j.expneurol.2021.113612 · Cited by 64
Brain–Machine Interface Control Algorithms
Shanechi, M. M. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2639501 · Cited by 61
Targeting Sensory and Motor Integration for Recovery of Movement After CNS Injury
Asan, A. S., McIntosh, J. R., & Carmel, J. B. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.791824 · Cited by 71
A cortical–spinal prosthesis for targeted limb movement in paralysed primate avatars
Shanechi, M. M., Hu, R. C., & Williams, Z. M. (2014) · Nature Communications · doi:10.1038/ncomms4237 · Cited by 62
Bidirectional brain-computer interfaces
Hughes, C. L., Herrera, A. J., Gaunt, R. A., & Collinger, J. L. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00013-5 · Cited by 65
Wang, D., Zhang, Q., Li, Y., Wang, Y., Zhu, J., Zhang, S., & Zheng, X. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/036009 · Cited by 60
Preliminary studies on the basic factors of bionics
Ren, L., & Liang, Y. (2014) · Science China Technological Sciences · doi:10.1007/s11431-013-5449-1 · Cited by 58
Bayesian statistics: relevant for the brain?
Kording, K. P. (2014) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2014.01.003 · Cited by 58
Cutrone, A., & Micera, S. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801345 · Cited by 58
Corticospinal neuroprostheses to restore locomotion after spinal cord injury
Borton, D. A., Bonizzato, M., Beauparlant, J., DiGiovanna, J., Moraud, E. M., Wenger, N., Евгеньевич, М. П., Minev, I. R., Lacour, S. P., Millán, J. D. R., et al. (2013) · Neuroscience Research · doi:10.1016/j.neures.2013.10.001 · Cited by 60
Implantable neurotechnologies: electrical stimulation and applications
Nag, S., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1442-0 · Cited by 56
Hanuschkin, A., Ganguli, S., & Hahnloser, R. H. R. (2013) · Frontiers in Neural Circuits · doi:10.3389/fncir.2013.00106 · Cited by 54
Oby, E. R., Éthier, C., & Miller, L. E. (2012) · Journal of Neurophysiology · doi:10.1152/jn.00331.2012 · Cited by 57
Self-citationHiremath, S. V., Chen, W., Wang, W., Foldes, S., Yang, Y., Tyler-Kabara, E. C., Collinger, J. L., & Boninger, M. L. (2015) · Frontiers in Integrative Neuroscience · doi:10.3389/fnint.2015.00040 · Cited by 53
Greenwald, E., Masters, M. R., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1429-x · Cited by 53
Nason, S. R., Mender, M. J., Vaskov, A. K., Willsey, M. S., Kumar, N. G., Kung, T. A., Patil, P. G., & Chestek, C. A. (2021) · Neuron · doi:10.1016/j.neuron.2021.08.009 · Cited by 55
Creating new functional circuits for action via brain-machine interfaces
Orsborn, A. L., & Carmena, J. M. (2013) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2013.00157 · Cited by 55
A Spatio-Temporal Fractal Model for a CPS Approach to Brain-Machine-Body Interfaces
Xue, Y., Rodríguez, S. H., & Bogdan, P. (2016) · Design, Automation, and Test in Europe · doi:10.3850/9783981537079_0502 · Cited by 52
Independent Mobility Achieved through a Wireless Brain-Machine Interface
Libedinsky, C., So, R. Q., Xu, Z., Kyar, T. K., Ho, D., Lim, C., Chan, L., Chua, Y., Yao, L., Cheong, J. H., et al. (2016) · PLoS ONE · doi:10.1371/journal.pone.0165773 · Cited by 52
Collinger, J. L., Gaunt, R. A., & Schwartz, A. B. (2018) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2018.11.005 · Cited by 53
Perel, S., Sadtler, P. T., Oby, E. R., Ryu, S. I., Tyler‐Kabara, E. C., Batista, A. P., & Chase, S. M. (2015) · Journal of Neurophysiology · doi:10.1152/jn.00293.2014 · Cited by 55
Self-citationCheung, V. C. K., Niu, C. M., Li, S., Xie, Q., & Lan, N. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2874132 · Cited by 53
Personalized Brain–Computer Interface and Its Applications
Ma, Y., Gong, A., Nan, W., Ding, P., Wang, F., & Fu, Y. (2022) · Journal of Personalized Medicine · doi:10.3390/jpm13010046 · Cited by 52
Carè, M., Chiappalone, M., & Cota, V. R. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1363128 · Cited by 51
Adversarial Domain Adaptation for Stable Brain-Machine Interfaces
Farshchian, A., Gallego, J. A., Cohen, J. P., Bengio, Y., Miller, L. E., & Solla, S. A. (2018) · arXiv · doi:10.48550/arxiv.1810.00045 · Cited by 48
Self-citationSystems Neuroengineering: Understanding and Interacting with the Brain
Edelman, B. J., Johnson, N., Sohrabpour, A., Tong, S., Thakor, N., & He, B. (2015) · Engineering · doi:10.15302/j-eng-2015078 · Cited by 45
Physiological properties of brain-machine interface input signals
Slutzky, M. W., & Flint, R. D. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00070.2017 · Cited by 47
Dangi, S., Gowda, S., Moorman, H. G., Orsborn, A. L., So, K., Shanechi, M. M., & Carmena, J. M. (2014) · Neural Computation · doi:10.1162/neco_a_00632 · Cited by 45
Murphy, M. D., Guggenmos, D. J., Bundy, D. T., & Nudo, R. J. (2016) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2015.00497 · Cited by 46
Optimal Feedback Control for Predicting Dynamic Stiffness During Arm Movement
Ueyama, Y., & Miyashita, E. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2273473 · Cited by 43
Toward a Proprioceptive Neural Interface that Mimics Natural Cortical Activity
Tomlinson, T., & Miller, L. E. (2016) · Advances in experimental medicine and biology · doi:10.1007/978-3-319-47313-0_20 · Cited by 44
Self-citationDonut‐Shaped Stretchable Kirigami: Enabling Electronics to Integrate with the Deformable Muscle
Morikawa, Y., Yamagiwa, S., Sawahata, H., Numano, R., Koida, K., & Kawano, T. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900939 · Cited by 43
Neurotechnologies to restore hand functions
Losanno, E., Mender, M. J., Chestek, C. A., Shokur, S., & Micera, S. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00054-4 · Cited by 45
Comparing temporal aspects of visual, tactile, and microstimulation feedback for motor control
Godlove, J. M., Whaite, E. O., & Batista, A. P. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/4/046025 · Cited by 46
Towards autonomous neuroprosthetic control using Hebbian reinforcement learning
Mahmoudi, B., Pohlmeyer, E. A., Prins, N. W., Geng, S., & Sanchez, J. C. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066005 · Cited by 42
Injecting Instructions into Premotor Cortex
Mazurek, K. A., & Schieber, M. H. (2017) · Neuron · doi:10.1016/j.neuron.2017.11.006 · Cited by 42
Prediction of Imagined Single-Joint Movements in a Person With High-Level Tetraplegia
Ajiboye, A. B., Simeral, J. D., Donoghue, J. P., Hochberg, L. R., & Kirsch, R. F. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2209882 · Cited by 44
Samejima, S., Henderson, R. P., Pradarelli, J. J., Mondello, S. E., & Moritz, C. T. (2022) · Experimental Neurology · doi:10.1016/j.expneurol.2022.114178 · Cited by 42
Enabling Low-Power, Multi-Modal Neural Interfaces Through a Common, Low-Bandwidth Feature Space
Irwin, Z. T., Thompson, D. E., Schroeder, K. E., Tat, D. M., Hassani, A., Bullard, A. J., Woo, S. L., Urbanchek, M. G., Sachs, A. J., Cederna, P. S., et al. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2501752 · Cited by 43
Leveraging neural dynamics to extend functional lifetime of brain-machine interfaces
Kao, J. C., Ryu, S. I., & Shenoy, K. V. (2017) · Scientific Reports · doi:10.1038/s41598-017-06029-x · Cited by 42
Kazim, S. F., Bowers, C. A., Cole, C. D., Varela, S., Karimov, Z., Martinez, E., Ogulnick, J. V., & Schmidt, M. H. (2021) · Molecular Neurobiology · doi:10.1007/s12035-021-02484-w · Cited by 45
Byun, D., Cho, S. J., & Kim, S. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/12/125010 · Cited by 39
Cracking the neural code, treating paralysis and the future of bioelectronic medicine
Bouton, C. E. (2017) · Journal of Internal Medicine · doi:10.1111/joim.12610 · Cited by 40
Tinkhauser, G., & Moraud, E. M. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.734186 · Cited by 39
Brain-controlled muscle stimulation for the restoration of motor function
Éthier, C., & Miller, L. E. (2014) · Neurobiology of Disease · doi:10.1016/j.nbd.2014.10.014 · Cited by 40
Self-citationEXiO—A Brain-Controlled Lower Limb Exoskeleton for Rhesus Macaques
Vouga, T., Zhuang, K., Olivier, J., Lebedev, M., Nicolelis, M. A. L., Bouri, M., & Bleuler, H. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2659654 · Cited by 40
Krucoff, M. O., Miller, J. P., Saxena, T. K., Bellamkonda, R., Rahimpour, S., Harward, S. C., Lad, S. P., & Turner, D. A. (2018) · Neurosurgery · doi:10.1093/neuros/nyy128 · Cited by 38
Sasada, S., Kato, K. H., Kadowaki, S., Groiss, S. J., Ugawa, Y., Komiyama, T., & Nishimura, Y. (2014) · Journal of Neuroscience · doi:10.1523/jneurosci.4674-13.2014 · Cited by 37
Multi-Muscle FES Force Control of the Human Arm for Arbitrary Goals
Schearer, E. M., Liao, Y.-W., Perreault, E. J., Tresch, M. C., Memberg, W. D., Kirsch, R. F., & Lynch, K. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2282903 · Cited by 37
Optimizing the learning rate for adaptive estimation of neural encoding models
Hsieh, H.-L., & Shanechi, M. M. (2018) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1006168 · Cited by 38
Design, control, and sensory feedback of externally powered hand prostheses: a literature review
Cloutier, A., & Yang, J. (2013) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2013007887 · Cited by 36
Real-Time Evaluation of a Noninvasive Neuroprosthetic Interface for Control of Reach
Corbett, E. A., Kording, K. P., & Perreault, E. J. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2251664 · Cited by 36
Now is the Critical Time for Engineered Neuroplasticity
Moritz, C. T. (2018) · Neurotherapeutics · doi:10.1007/s13311-018-0637-0 · Cited by 37
Decoding and geometry of ten finger movements in human posterior parietal cortex and motor cortex
Guan, C., Aflalo, T., KADLEC, K. H., Gámez, J., Rosario, E. R., Bari, A., Pouratian, N., & Andersen, R. A. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acd3b1 · Cited by 38
Oby, E. R., Perel, S., Sadtler, P. T., Ruff, D. A., Mischel, J., Montez, D. F., Cohen, M. R., Batista, A. P., & Chase, S. M. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036009 · Cited by 35
Self-citationManohar, A., Foffani, G., Ganzer, P. D., Bethea, J. R., & Moxon, K. A. (2017) · eLife · doi:10.7554/elife.23532 · Cited by 38
Chandrasekaran, S., Fifer, M. S., Bickel, S., Osborn, L. E., Herrero, J. L., Christie, B. P., Xu, J., Murphy, R. K. J., Singh, S., Glasser, M. F., et al. (2021) · Bioelectronic Medicine · doi:10.1186/s42234-021-00076-6 · Cited by 39
Khan, M. A., Saibene, M., Das, R., Brunner, I. C., & Puthusserypady, S. K. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac36aa · Cited by 35
Mrachacz-Kersting, N., Voigt, M., Stevenson, A. J. T., Aliakbaryhosseinabadi, S., Jiang, N., Dremstrup, K., & Farina, D. (2017) · Brain Research · doi:10.1016/j.brainres.2017.08.025 · Cited by 35
Augmenting intracortical brain-machine interface with neurally driven error detectors
Even-Chen, N., Stavisky, S. D., Kao, J. C., Ryu, S. I., & Shenoy, K. V. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8dc1 · Cited by 35
Electrical induction of vision
Tehovnik, E. J., & Slocum, W. M. (2013) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2013.03.012 · Cited by 33
An, H., Nason, S. R., Lim, J., Kwon, K., Willsey, M. S., Patil, P. G., Kim, H.-S., Sylvester, D., Chestek, C. A., & Blaauw, D. T. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3175926 · Cited by 33
Transfer of information by BMI
Tehovnik, E. J., Woods, L., & Slocum, W. M. (2013) · Neuroscience · doi:10.1016/j.neuroscience.2013.10.003 · Cited by 32
Perruchoud, D., Pisotta, I., Carda, S., Murray, M. M., & Ionta, S. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/041001 · Cited by 32
Forward Prediction in the Posterior Parietal Cortex and Dynamic Brain-Machine Interface
Cui, H. (2016) · Frontiers in Integrative Neuroscience · doi:10.3389/fnint.2016.00035 · Cited by 33
Zhang, M., Schwemmer, M. A., Ting, J. E., Majstorovic, C., Friedenberg, D. A., Bockbrader, M. A., Mysiw, W. J., Rezai, A. R., Annetta, N. V., Bouton, C. E., et al. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0011-x · Cited by 33
Bypassing stroke-damaged neural pathways via a neural interface induces targeted cortical adaptation
Kato, K., Sawada, M., & Nishimura, Y. (2019) · Nature Communications · doi:10.1038/s41467-019-12647-y · Cited by 33
A modular strategy for next-generation upper-limb sensory-motor neuroprostheses
Shokur, S., Mazzoni, A., Schiavone, G., Weber, D. J., & Micera, S. (2021) · Med · doi:10.1016/j.medj.2021.05.002 · Cited by 35
Chen, C., Shin, D., Watanabe, H., Nakanishi, Y., Kambara, H., Yoshimura, N., Nambu, A., Isa, T., Nishimura, Y., & Koike, Y. (2014) · Neuroscience Research · doi:10.1016/j.neures.2014.03.010 · Cited by 33
A training platform for many-dimensional prosthetic devices using a virtual reality environment
Putrino, D. F., Wong, Y. T., Weiss, A., & Pesaran, B. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.03.010 · Cited by 32
Decoding Hindlimb Movement for a Brain Machine Interface after a Complete Spinal Transection
Manohar, A., Flint, R. D., Knudsen, E. B., & Moxon, K. A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0052173 · Cited by 34
The future of upper extremity rehabilitation robotics: research and practice
Vu, P. P., Chestek, C. A., Nason, S. R., Kung, T. A., Kemp, S. W. P., & Cederna, P. S. (2020) · Muscle & Nerve · doi:10.1002/mus.26860 · Cited by 33
Kumaravelu, K., Tomlinson, T., Callier, T., Sombeck, J. T., Bensmaı̈a, S. J., Miller, L. E., & Grill, W. M. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abacd8 · Cited by 32
Self-citationGeneralizable cursor click decoding using grasp-related neural transients
Dekleva, B. M., Weiss, J. M., Boninger, M. L., & Collinger, J. L. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac16b2 · Cited by 33
FES Control of Isometric Forces in the Rat Hindlimb Using Many Muscles
Jarc, A., Berniker, M., & Tresch, M. C. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2237768 · Cited by 31
Designing Dynamical Properties of Brain–Machine Interfaces to Optimize Task-Specific Performance
Gowda, S., Orsborn, A. L., Overduin, S. A., Moorman, H. G., & Carmena, J. M. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2309673 · Cited by 33
Cortical Control of Virtual Self-Motion Using Task-Specific Subspaces
Schroeder, K. E., Perkins, S. M., Wang, Q., & Churchland, M. M. (2021) · Journal of Neuroscience · doi:10.1523/jneurosci.2687-20.2021 · Cited by 31
Degraded EEG decoding of wrist movements in absence of kinaesthetic feedback
Galán, F., Baker, M. R., Alter, K., & Baker, S. N. (2014) · Human Brain Mapping · doi:10.1002/hbm.22653 · Cited by 30
Neuroplasticity subserving the operation of brain–machine interfaces
Oweiss, K. G., & Badreldin, I. S. (2015) · Neurobiology of Disease · doi:10.1016/j.nbd.2015.05.001 · Cited by 33
New Perspectives on Neuroengineering and Neurotechnologies: NSF-DFG Workshop Report
Moritz, C. T., Ruther, P., Goering, S., Stett, A., Ball, T., Burgard, W., Chudler, E. H., & Rao, R. P. N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2543662 · Cited by 30
Evaluation of high-density, multi-contact nerve cuffs for activation of grasp muscles in monkeys
Brill, N., Naufel, S. N., Polasek, K. H., Éthier, C., Cheesborough, J. E., Agnew, S. P., Miller, L. E., & Tyler, D. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8735 · Cited by 30
Self-citationWidge, A. S., & Moritz, C. T. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/024001 · Cited by 29
Primary motor cortical discharge during force field adaptation reflects muscle-like dynamics
Cherian, A., Fernandes, H. L., & Miller, L. E. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00109.2012 · Cited by 30
Self-citationEvolution, biomechanics, and neurobiology converge to explain selective finger motor control
Xu, J., Mawase, F., & Schieber, M. H. (2024) · Physiological Reviews · doi:10.1152/physrev.00030.2023 · Cited by 32
Brain–computer interfaces for patients with disorders of consciousness
Gibson, R. M., Owen, A. M., & Cruse, D. (2016) · Progress in brain research · doi:10.1016/bs.pbr.2016.04.003 · Cited by 29
Akan, O. B., Ramezani, H., Civas, M., Cetinkaya, O., Bilgin, B. A., & Abbasi, N. A. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3056455 · Cited by 28
An implantable, wireless, battery-free system for tactile pressure sensing
Du, L., Hao, H., Ding, Y., Gabros, A. D., Mier, T. C. E., der Spiegel, J. V., Lucas, T. H., Aflatouni, F., Richardson, A. G., & Allen, M. G. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00602-3 · Cited by 27
Xu, S., Li, C., Wei, C., Kang, X., Shu, S., Liu, G., Xu, Z., Han, M., Luo, J., & Tang, W. (2024) · Advanced Science · doi:10.1002/advs.202304763 · Cited by 27
Interfacing with the nervous system: a review of current bioelectric technologies
Sahyouni, R., Mahmoodi, A., Chen, J. W., Chang, D. T., Moshtaghi, O., Djalilian, H. R., & Lin, H. W. (2017) · Neurosurgical Review · doi:10.1007/s10143-017-0920-2 · Cited by 28
Motor maps and the cortical control of movement
Harrison, T. C., & Murphy, T. H. (2013) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2013.08.018 · Cited by 28
Intracortical Brain-Machine Interfaces Advance Sensorimotor Neuroscience
Schroeder, K. E., & Chestek, C. A. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00291 · Cited by 28
Distributed stimulation increases force elicited with functional electrical stimulation
Buckmire, A. J., Lockwood, D. R., Doane, C. J., & Fuglevand, A. J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9820 · Cited by 26
Rastogi, A., Vargas-Irwin, C. E., Willett, F. R., Abreu, J., Crowder, D. C., Murphy, B. A., Memberg, W. D., Miller, J. P., Sweet, J. A., Walter, B. L., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-58097-1 · Cited by 28
Speech-related dorsal motor cortex activity does not interfere with iBCI cursor control
Stavisky, S. D., Willett, F. R., Avansino, D. T., Hochberg, L. R., Shenoy, K. V., & Henderson, J. M. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5b72 · Cited by 25
Metadata
- Authors
- Ethier, C., Oby, E. R., Bauman, M. J., & Miller, L. E.
- Affiliations
- Northwestern University (US)
- University of Pittsburgh (US)
- Corresponding author
- Miller, L. E.
- Venue
- Nature
- Published
- 2012-04-18
- Volume
- 485
- Issue
- 7398
- Pages
- 368-371
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- PMC
- PMC3358575
- OpenAlex
- W1988067967
- Cited by
- 485
- References
- 26
- Citations by year
- 2026: 9 · 2025: 22 · 2024: 24 · 2023: 27 · 2022: 24 · 2021: 33 · 2020: 29 · 2019: 28 · 2018: 42 · 2017: 44 · 2016: 46 · 2015: 38 · 2014: 55 · 2013: 46 · 2012: 18
- FWCI
- 20.69
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (R01NS053603, F31NS071737, #NS053603)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- brain-computer interface, functional electrical stimulation, paralysis, spinal cord injury, motor cortex, neural prostheses, hand grasping, rhesus monkeys, tetraplegia, hand function recovery, prosthetic hand control
- MeSH terms
- Animals, Electric Stimulation, Electrodes, Implanted, Hand, Macaca mulatta, Microelectrodes, Motor Cortex, Movement, Muscles, Nerve Block, Paralysis, Quadriplegia, Spinal Cord Injuries, Hand Strength, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review