The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Restoration of grasp following paralysis through brain-controlled stimulation of muscles
Open accessAbstract
Patients with spinal cord injury lack the connections between brain and spinal cord circuits that are essential for voluntary movement. Clinical systems that achieve muscle contraction through functional electrical stimulation (FES) have proven to be effective in allowing patients with tetraplegia to regain control of hand movements and to achieve a greater measure of independence in daily activities. In existing clinical systems, the patient uses residual proximal limb movements to trigger pre-programmed stimulation that causes the paralysed muscles to contract, allowing use of one or two basic grasps. Instead, we have developed an FES system in primates that is controlled by recordings made from microelectrodes permanently implanted in the brain. We simulated some of the effects of the paralysis caused by C5 or C6 spinal cord injury by injecting rhesus monkeys with a local anaesthetic to block the median and ulnar nerves at the elbow. Then, using recordings from approximately 100 neurons in the motor cortex, we predicted the intended activity of several of the paralysed muscles, and used these predictions to control the intensity of stimulation of the same muscles. This process essentially bypassed the spinal cord, restoring to the monkeys voluntary control of their paralysed muscles. This achievement is a major advance towards similar restoration of hand function in human patients through brain-controlled FES. We anticipate that in human patients, this neuroprosthesis would allow much more flexible and dexterous use of the hand than is possible with existing FES systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“CNS-based neuroprostheses, or brain–machine interfaces (BMIs), are systems whereby neural electrical activities are decoded and used to control robotic limbs [76, 89, 105] or to stimulate muscles for restoring limb function [35].”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [35]
In the citing paper
“Currently, all reported BMI experiments with human patients [26, 35, 57, 58, 150] require the subjects tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [35]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Targeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094
McDonald, J. W., & Sadowsky, C. L. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07603-1 · Cited by 1,858
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761
Relation of pyramidal tract activity to force exerted during voluntary movement.
Evarts, E. V. (1968) · Journal of Neurophysiology · doi:10.1152/jn.1968.31.1.14 · Cited by 1,258
Direct control of paralysed muscles by cortical neurons
Moritz, C. T., Perlmutter, S. I., & Fetz, E. E. (2008) · Nature · doi:10.1038/nature07418 · Cited by 610
Spasticity after spinal cord injury
Adams, M. M., & Hicks, A. L. (2005) · Spinal Cord · doi:10.1038/sj.sc.3101757 · Cited by 517
Motor and sensory recovery following incomplete tetraplegia
Waters, R. L., Adkins, R. H., Yakura, J. S., & Sie, I. H. (1994) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/0003-9993(94)90034-5 · Cited by 438
Predicting Measures of Motor Performance from Multiple Cortical Spike Trains
Humphrey, D. R., Schmidt, E. M., & Thompson, W. (1970) · Science · doi:10.1126/science.170.3959.758 · Cited by 372
Peckham, P. H., Keith, M. W., Kilgore, K. L., Grill, J. H., Wuolle, K. S., Thrope, G. B., Gorman, P., Hobby, J., Mulcahey, M. J., Carroll, S., et al. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.25910 · Cited by 319
Implantable functional neuromuscular stimulation in the tetraplegic hand
Keith, M. W., Peckham, P. H., Thrope, G. B., Stroh, K. C., Smith, B., Buckett, J. R., Kilgore, K. L., & Jatich, J. W. (1989) · The Journal Of Hand Surgery · doi:10.1016/s0363-5023(89)80017-6 · Cited by 212
Cited by
Sorted by citations
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Restoring cortical control of functional movement in a human with quadriplegia
Bouton, C. E., Shaikhouni, A., Annetta, N. V., Bockbrader, M. A., Friedenberg, D. A., Nielson, D. M., Sharma, G., Sederberg, P. B., Glenn, B. C., Mysiw, W. J., et al. (2016) · Nature · doi:10.1038/nature17435 · Cited by 924
Ajiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862
Neural Manifolds for the Control of Movement
Gallego, J. Á., Perich, M. G., Miller, L. E., & Solla, S. A. (2017) · Neuron · doi:10.1016/j.neuron.2017.05.025 · Cited by 676
Self-citationBrain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 695
A brain–spine interface alleviating gait deficits after spinal cord injury in primates
Capogrosso, M., Milekovic, T., Borton, D., Wagner, F., Moraud, E. M., Mignardot, J.-B., Buse, N., Gandar, J., Barraud, Q., Xing, D., et al. (2016) · Nature · doi:10.1038/nature20118 · Cited by 635
Pandarinath, C., Nuyujukian, P., Blabe, C. H., Sorice, B. L., Saab, J., Willett, F. R., Hochberg, L. R., Shenoy, K. V., & Henderson, J. M. (2017) · eLife · doi:10.7554/elife.18554 · Cited by 566
“Additionally, Ethier et al ( Ethier et al., 2012 ). showed that monkeys whose grasping movements were prevented using a paralytic agent were still able to reliably generate grasping-related cortical activity, which could then be decoded to activate a functional electrical stimulation system that…”
BackgroundWodlinger, B., Downey, J. E., Tyler-Kabara, E. C., Schwartz, A. B., Boninger, M. L., & Collinger, J. L. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016011 · Cited by 536
Spinal cord repair: advances in biology and technology
Courtine, G., & Sofroniew, M. V. (2019) · Nature Medicine · doi:10.1038/s41591-019-0475-6 · Cited by 508
Long-term stability of cortical population dynamics underlying consistent behavior
Gallego, J. Á., Perich, M. G., Chowdhury, R. H., Solla, S. A., & Miller, L. E. (2020) · Nature Neuroscience · doi:10.1038/s41593-019-0555-4 · Cited by 429
Self-citationRestoring sensorimotor function through intracortical interfaces: progress and looming challenges
Bensmaia, S. J., & Miller, L. E. (2014) · Nature Reviews Neuroscience · doi:10.1038/nrn3724 · Cited by 368
Self-citationJarosiewicz, B., Sarma, A. A., Bacher, D., Masse, N. Y., Simeral, J. D., Sorice, B., Oakley, E. M., Blabe, C., Pandarinath, C., Gilja, V., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac7328 · Cited by 340
Machine Learning for Neural Decoding
Glaser, J. I., Benjamin, A. S., Chowdhury, R. H., Perich, M. G., Miller, L. E., & Kording, K. P. (2020) · eNeuro · doi:10.1523/eneuro.0506-19.2020 · Cited by 361
Self-citationCortical population activity within a preserved neural manifold underlies multiple motor behaviors
Gallego, J. Á., Perich, M. G., Naufel, S. N., Éthier, C., Solla, S. A., & Miller, L. E. (2018) · Nature Communications · doi:10.1038/s41467-018-06560-z · Cited by 355
Self-citationBrain–machine interfaces in neurorehabilitation of stroke
Soekadar, S. R., Birbaumer, N., Slutzky, M. W., & Cohen, L. G. (2014) · Neurobiology of Disease · doi:10.1016/j.nbd.2014.11.025 · Cited by 352
A polymer optoelectronic interface restores light sensitivity in blind rat retinas
Ghezzi, D., Antognazza, M. R., Maccarone, R., Bellani, S., Lanzarini, E., Martino, N., Mete, M., Pertile, G., Bisti, S., Lanzani, G., et al. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.34 · Cited by 327
Summary of over Fifty Years with Brain-Computer Interfaces—A Review
Kawala‐Sterniuk, A., Browarska, N., Al‐Bakri, A. F., Pelc, M., Zygarlicki, J., Šidiková, M., Martínek, R., & Gorzelańczyk, E. J. (2021) · Brain Sciences · doi:10.3390/brainsci11010043 · Cited by 321
Brain–machine interfaces from motor to mood
Shanechi, M. M. (2019) · Nature Neuroscience · doi:10.1038/s41593-019-0488-y · Cited by 263
Khan, M. A., Das, R., Iversen, H. K., & Puthusserypady, S. K. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103843 · Cited by 269
Neural interfaces for the brain and spinal cord—restoring motor function
Andrew, J. O., & Zimmermann, J. B. (2012) · Nature Reviews Neurology · doi:10.1038/nrneurol.2012.219 · Cited by 260
A Brain-to-Brain Interface for Real-Time Sharing of Sensorimotor Information
Pais-Vieira, M., Lebedev, M., Kunicki, C., Wang, J., & Nicolelis, M. A. L. (2013) · Scientific Reports · doi:10.1038/srep01319 · Cited by 252
Hramov, A. E., Александрович, М. В., & Pisarchik, A. N. (2021) · Physics Reports · doi:10.1016/j.physrep.2021.03.002 · Cited by 228
Wenger, N., Moraud, E. M., Raspopovic, S., Bonizzato, M., DiGiovanna, J., Musienko, P., Morari, M., Micera, S., & Courtine, G. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008325 · Cited by 209
Neuromodulation in the restoration of function after spinal cord injury
James, N. D., McMahon, S. B., Field-Fote, E. C., & Bradbury, E. J. (2018) · The Lancet Neurology · doi:10.1016/s1474-4422(18)30287-4 · Cited by 192
Krucoff, M. O., Rahimpour, S., Slutzky, M. W., Edgerton, V. R., & Turner, D. A. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00584 · Cited by 196
Artoni, F., Fanciullacci, C., Bertolucci, F., Panarese, A., Makeig, S., Micera, S., & Chisari, C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.013 · Cited by 189
Flint, R. D., Wright, Z. A., Scheid, M. R., & Slutzky, M. W. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056005 · Cited by 184
MXene-infused bioelectronic interfaces for multiscale electrophysiology and stimulation
Driscoll, N., Erickson, B. A., Murphy, B. B., Richardson, A. G., Robbins, G., Apollo, N. V., Mentzelopoulos, G., Mathis, T. S., Hantanasirisakul, K., Bagga, P., et al. (2021) · Science Translational Medicine · doi:10.1126/scitranslmed.abf8629 · Cited by 180
Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants
Prasad, A., Xue, Q.-S., Dieme, R., Sankar, V., Mayrand, R. C., Nishida, T., Streit, W. J., & Sanchez, J. C. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00002 · Cited by 178
A low-power stretchable neuromorphic nerve with proprioceptive feedback
Lee, Y., Liu, Y., Seo, D.-G., Oh, J. Y., Kim, Y., Li, J., Kang, J., Kim, J., Mun, J., Foudeh, A. M., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00918-x · Cited by 177
Wang, J., Wang, H., Thakor, N. V., & Lee, C. (2019) · ACS Nano · doi:10.1021/acsnano.9b00140 · Cited by 179
Combining Decoder Design and Neural Adaptation in Brain-Machine Interfaces
Shenoy, K. V., & Carmena, J. M. (2014) · Neuron · doi:10.1016/j.neuron.2014.08.038 · Cited by 181
Borton, D., Micera, S., Millán, J. D. R., & Courtine, G. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005968 · Cited by 171
Bioelectronics for electrical stimulation: materials, devices and biomedical applications
Huang, Y., Yao, K., Zhang, Q., Huang, X., Chen, Z., Zhou, Y., & Yu, X. (2024) · Chemical Society Reviews · doi:10.1039/d4cs00413b · Cited by 168
Wearable Triboelectric Nanogenerators for Therapeutics
Xiao, X., Chen, G., Libanori, A., & Chen, J. (2021) · Trends in Chemistry · doi:10.1016/j.trechm.2021.01.001 · Cited by 152
Brain-controlled modulation of spinal circuits improves recovery from spinal cord injury
Bonizzato, M., Pidpruzhnykova, G., DiGiovanna, J., Shkorbatova, P., Pavlova, N., Micera, S., & Courtine, G. (2018) · Nature Communications · doi:10.1038/s41467-018-05282-6 · Cited by 149
Teaching brain-machine interfaces as an alternative paradigm to neuroprosthetics control
Iturrate, I., Chavarriaga, R., Montesano, L., Minguez, J., & Millán, J. D. R. (2015) · Scientific Reports · doi:10.1038/srep13893 · Cited by 149
Implantable intracortical microelectrodes: reviewing the present with a focus on the future
Wang, Y., Yang, X., Zhang, X., Wang, Y., & Pei, W. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00451-6 · Cited by 147
Ortiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144
Wearable and Implantable Electroceuticals for Therapeutic Electrostimulations
Long, Y., Li, J., Yang, F., Wang, J., & Wang, X. (2021) · Advanced Science · doi:10.1002/advs.202004023 · Cited by 141
Wang, J., Wang, H., He, T., He, B., Thakor, N. V., & Lee, C. (2019) · Advanced Science · doi:10.1002/advs.201900149 · Cited by 138
Stavisky, S. D., Kao, J. C., Nuyujukian, P., Ryu, S. I., & Shenoy, K. V. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/036009 · Cited by 139
Synergy-Based FES for Post-Stroke Rehabilitation of Upper-Limb Motor Functions
Niu, C. M., Bao, Y., Zhuang, C., Li, S., Wang, T., Cui, L., Xie, Q., & Lan, N. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2891004 · Cited by 133
Brain–Computer Interface after Nervous System Injury
Burns, A., Adeli, H., & Buford, J. A. (2014) · The Neuroscientist · doi:10.1177/1073858414549015 · Cited by 132
Translating the Brain-Machine Interface
Thakor, N. V. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007303 · Cited by 128
Preparatory activity and the expansive null-space
Churchland, M. M., & Shenoy, K. V. (2024) · Nature reviews. Neuroscience · doi:10.1038/s41583-024-00796-z · Cited by 135
Brain-Machine Interfaces beyond Neuroprosthetics
Moxon, K. A., & Foffani, G. (2015) · Neuron · doi:10.1016/j.neuron.2015.03.036 · Cited by 126
Configuration of electrical spinal cord stimulation through real-time processing of gait kinematics
Capogrosso, M., Wagner, F. B., Gandar, J., Moraud, E. M., Wenger, N., Milekovic, T., Shkorbatova, P. Y., Pavlova, N., Евгеньевич, М. П., Bézard, E., et al. (2018) · Nature Protocols · doi:10.1038/s41596-018-0030-9 · Cited by 125
Rapid control and feedback rates enhance neuroprosthetic control
Shanechi, M. M., Orsborn, A. L., Moorman, H. G., Gowda, S., Dangi, S., & Carmena, J. M. (2017) · Nature Communications · doi:10.1038/ncomms13825 · Cited by 125
Sensors and Decoding for Intracortical Brain Computer Interfaces
Homer, M. L., Nurmikko, A. V., Donoghue, J. P., & Hochberg, L. R. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124640 · Cited by 121
Decoding and perturbing decision states in real time
Peixoto, D., Verhein, J. R., Kiani, R., Kao, J. C., Nuyujukian, P., Chandrasekaran, C., Brown, J., Fong, S., Ryu, S. I., Shenoy, K. V., et al. (2021) · Nature · doi:10.1038/s41586-020-03181-9 · Cited by 123
Advances in Neuroprosthetic Learning and Control
Carmena, J. M. (2013) · PLoS Biology · doi:10.1371/journal.pbio.1001561 · Cited by 117
Graphene oxide doped conducting polymer nanocomposite film for electrode-tissue interface
Tian, H., Liu, J., Wei, D., Kang, X., Zhang, C., Du, J., Yang, B. T., Chen, X., Zhu, H., NuLi, Y., et al. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.11.058 · Cited by 118
Shanechi, M. M., Orsborn, A. L., & Carmena, J. M. (2016) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1004730 · Cited by 118
Nason, S. R., Vaskov, A. K., Willsey, M. S., Welle, E. J., An, H., Vu, P. P., Bullard, A. J., Nu, C. S., Kao, J. C., Shenoy, K. V., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0591-0 · Cited by 113
Brain-machine interfaces: an overview.
Lebedev, M. (2014) · Translational Neuroscience · doi:10.2478/s13380-014-0212-z · Cited by 112
Perceiving invisible light through a somatosensory cortical prosthesis
Thomson, E. E., Carra, R. B., & Nicolelis, M. A. L. (2013) · Nature Communications · doi:10.1038/ncomms2497 · Cited by 117
Liu, X., Zhang, M., Richardson, A. G., Lucas, T. H., & der Spiegel, J. V. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2622738 · Cited by 112
Barra, B., Conti, S., Perich, M. G., Zhuang, K., Schiavone, G., Fallegger, F., Galan, K., James, N. D., Barraud, Q., Delacombaz, M., et al. (2022) · Nature Neuroscience · doi:10.1038/s41593-022-01106-5 · Cited by 114
Mind Reading and Writing: The Future of Neurotechnology
Roelfsema, P. R., Denys, D., & Klink, P. C. (2018) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2018.04.001 · Cited by 107
Jarosiewicz, B., Masse, N. Y., Bacher, D., Cash, S. S., Eskandar, E. N., Friehs, G. M., Donoghue, J. P., & Hochberg, L. R. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046012 · Cited by 115
Interfaces with the Peripheral Nerve for the Control of Neuroprostheses
del Valle, J., & Navarro, X. (2013) · International Review of Neurobiology · doi:10.1016/b978-0-12-420045-6.00002-x · Cited by 105
Nishimura, Y., Perlmutter, S. I., & Fetz, E. E. (2013) · Frontiers in Neural Circuits · doi:10.3389/fncir.2013.00057 · Cited by 105
Design and analysis of closed-loop decoder adaptation algorithms for brain-machine interfaces
Dangi, S., Orsborn, A. L., Moorman, H. G., & Carmena, J. M. (2013) · Neural Computation · doi:10.1162/neco_a_00460 · Cited by 103
Latent Factors and Dynamics in Motor Cortex and Their Application to Brain–Machine Interfaces
Pandarinath, C., Ames, K. C., Russo, A. A., Farshchian, A., Miller, L. E., Dyer, E. L., & Kao, J. C. (2018) · The Journal of Neuroscience · doi:10.1523/jneurosci.1669-18.2018 · Cited by 103
Self-citationA unifying model of concurrent spatial and temporal modularity in muscle activity
Delis, I., Panzeri, S., Pozzo, T., & Berret, B. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00245.2013 · Cited by 103
Review: Human Intracortical Recording and Neural Decoding for Brain–Computer Interfaces
Brandman, D. M., Cash, S. S., & Hochberg, L. R. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2677443 · Cited by 104
Interfacing the Somatosensory System to Restore Touch and Proprioception: Essential Considerations
Weber, D. J., Friesen, R., & Miller, L. E. (2012) · Journal of Motor Behavior · doi:10.1080/00222895.2012.735283 · Cited by 98
Self-citationThe Smartest Materials: The Future of Nanoelectronics in Medicine
Cohen‐Karni, T., Langer, R., & Kohane, D. S. (2012) · ACS Nano · doi:10.1021/nn302915s · Cited by 95
Flint, R. D., Scheid, M. R., Wright, Z. A., Solla, S. A., & Slutzky, M. W. (2016) · Journal of Neuroscience · doi:10.1523/jneurosci.2339-15.2016 · Cited by 93
Recent development of implantable and flexible nerve electrodes
Shi, Y., Liu, R., He, L. M., Feng, H., Li, Y., & Li, Z. (2020) · Smart Materials in Medicine · doi:10.1016/j.smaim.2020.08.002 · Cited by 93
Closed-loop control of spinal cord stimulation to restore hand function after paralysis
Zimmermann, J. B., & Andrew, J. O. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00087 · Cited by 91
Cui, Y., Khan, S. U., Deng, Y., Zhao, M., & Hou, M. (2020) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2020.142170 · Cited by 87
Neuroprosthetic technology for individuals with spinal cord injury
Collinger, J. L., Foldes, S. T., Bruns, T. M., Wodlinger, B., Gaunt, R. A., & Weber, D. J. (2013) · Journal of Spinal Cord Medicine · doi:10.1179/2045772313y.0000000128 · Cited by 91
The Emergence of Single Neurons in Clinical Neurology
Cash, S. S., & Hochberg, L. R. (2015) · Neuron · doi:10.1016/j.neuron.2015.03.058 · Cited by 87
Brain-Machine Interfaces: Powerful Tools for Clinical Treatment and Neuroscientific Investigations
Slutzky, M. W. (2018) · The Neuroscientist · doi:10.1177/1073858418775355 · Cited by 86
Deep learning approaches for neural decoding across architectures and recording modalities
Livezey, J. A., & Glaser, J. I. (2020) · Briefings in Bioinformatics · doi:10.1093/bib/bbaa355 · Cited by 94
Implantable neurotechnologies: a review of integrated circuit neural amplifiers
Ng, K. A., Greenwald, E., Xu, Y. P., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1431-3 · Cited by 83
Area 2 of primary somatosensory cortex encodes kinematics of the whole arm
Chowdhury, R. H., Glaser, J. I., & Miller, L. E. (2020) · eLife · doi:10.7554/elife.48198 · Cited by 84
Self-citationBrain-controlled neuromuscular stimulation to drive neural plasticity and functional recovery
Éthier, C., Gallego, J. Á., & Miller, L. E. (2015) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2015.03.007 · Cited by 84
Self-citationNeuroprosthetic-enabled control of graded arm muscle contraction in a paralyzed human
Friedenberg, D. A., Schwemmer, M. A., Landgraf, A. J., Annetta, N. V., Bockbrader, M. A., Bouton, C. E., Zhang, M., Rezai, A. R., Mysiw, W. J., Bresler, H. S., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-08120-9 · Cited by 83
Soft human–machine interfaces: design, sensing and stimulation
Dong, W., Wang, Y., Zhou, Y., Bai, Y., Ju, Z., Guo, J., Gu, G., Bai, K., Ouyang, G., Chen, S., et al. (2018) · International Journal of Intelligent Robotics and Applications · doi:10.1007/s41315-018-0060-z · Cited by 81
Decoding Local Field Potentials for Neural Interfaces
Andrew, J. O., & Hall, T. M. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2612001 · Cited by 78
The science and engineering behind sensitized brain-controlled bionic hands
Pandarinath, C., & Bensmaïa, S. J. (2021) · Physiological Reviews · doi:10.1152/physrev.00034.2020 · Cited by 79
Design and validation of a real-time spiking-neural-network decoder for brain–machine interfaces
Dethier, J., Nuyujukian, P., Ryu, S. I., Shenoy, K. V., & Boahen, K. A. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036008 · Cited by 76
Brain control of bimanual movement enabled by recurrent neural networks
Deo, D. R., Willett, F. R., Avansino, D. T., Hochberg, L. R., Henderson, J. M., & Shenoy, K. V. (2024) · Scientific Reports · doi:10.1038/s41598-024-51617-3 · Cited by 77
Stabilizing brain-computer interfaces through alignment of latent dynamics
Karpowicz, B. M., Ali, Y. H., Wimalasena, L. N., Sedler, A. R., Keshtkaran, M. R., Bodkin, K. L., Ma, X., Rubin, D. B., Williams, Z. M., Cash, S. S., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-59652-y · Cited by 94
Self-citationExtracting kinetic information from human motor cortical signals
Flint, R. D., Wang, P. T., Wright, Z. A., King, C., Krucoff, M. O., Schuele, S., Rosenow, J. M., Hsu, F. P. K., Liu, C. Y., Lin, J. J., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.07.049 · Cited by 73
Implantable Self‐Powered Systems for Electrical Stimulation Medical Devices
Cui, X. J., Wu, L., Zhang, C., & Li, Z. (2024) · Advanced Science · doi:10.1002/advs.202412044 · Cited by 75
Intrafascicular stimulation of monkey arm nerves evokes coordinated grasp and sensory responses
Ledbetter, N. M., Ethier, C., Oby, E. R., Hiatt, S. D., Wilder, A. M., Ko, J. H., Agnew, S. P., Miller, L. E., & Clark, G. A. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00688.2011 · Cited by 69
Self-citationThe utility of multichannel local field potentials for brain–machine interfaces
Hwang, E. J., & Andersen, R. A. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046005 · Cited by 70
Collinger, J. L., Kryger, M. A., Barbara, R., Betler, T., Bowsher, K., Brown, E. H. P., Clanton, S. T., Degenhart, A. D., Foldes, S. T., Gaunt, R. A., et al. (2014) · Clinical and Translational Science · doi:10.1111/cts.12086 · Cited by 68
Intention estimation in brain–machine interfaces
Fan, J. M., Nuyujukian, P., Kao, J. C., Chestek, C. A., Ryu, S. I., & Shenoy, K. V. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016004 · Cited by 70
Alam, M., Rodrigues, W., Pham, B., & Thakor, N. V. (2016) · Brain Research · doi:10.1016/j.brainres.2016.05.039 · Cited by 69
Dendritic calcium signals in rhesus macaque motor cortex drive an optical brain-computer interface
Trautmann, E. M., O’Shea, D. J., Sun, X., Marshel, J. H., Crow, A., Hsueh, B., Vesuna, S. S., Cofer, L. B., Bohner, G., Allen, W., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-23884-5 · Cited by 68
The PennBMBI: Design of a General Purpose Wireless Brain-Machine-Brain Interface System
Liu, X., Zhang, M., Subei, B., Richardson, A. G., Lucas, T. H., & der Spiegel, J. V. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2392555 · Cited by 67
Performance sustaining intracortical neural prostheses
Nuyujukian, P., Kao, J. C., Fan, J. M., Stavisky, S. D., Ryu, S. I., & Shenoy, K. V. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/6/066003 · Cited by 68
Neurostimulation for Stroke Rehabilitation
Ting, W. K., Fadul, F. A.-R., Fecteau, S., & Éthier, C. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.649459 · Cited by 65
Brain-Computer-Spinal Interface Restores Upper Limb Function After Spinal Cord Injury
Samejima, S., Khorasani, A., Ranganathan, V. N., Nakahara, J., Tolley, N. M., Boissenin, A., Shalchyan, V., Daliri, M. R., Smith, J. R., & Moritz, C. T. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3090269 · Cited by 69
Motor cortical activity changes during neuroprosthetic-controlled object interaction
Downey, J. E., Brane, L., Gaunt, R. A., Tyler-Kabara, E. C., Boninger, M. L., & Collinger, J. L. (2017) · Scientific Reports · doi:10.1038/s41598-017-17222-3 · Cited by 63
Metadata
- Authors
- Ethier, C., Oby, E. R., Bauman, M. J., & Miller, L. E.
- Affiliations
- Northwestern University (US)
- University of Pittsburgh (US)
- Corresponding author
- Miller, L. E.
- Venue
- Nature
- Published
- 2012-04-18
- Volume
- 485
- Issue
- 7398
- Pages
- 368-371
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- PMC
- PMC3358575
- OpenAlex
- W1988067967
- Cited by
- 485
- References
- 26
- Citations by year
- 2026: 9 · 2025: 22 · 2024: 24 · 2023: 27 · 2022: 24 · 2021: 33 · 2020: 29 · 2019: 28 · 2018: 42 · 2017: 44 · 2016: 46 · 2015: 38 · 2014: 55 · 2013: 46 · 2012: 18
- FWCI
- 20.69
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (R01NS053603, F31NS071737, #NS053603)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Clinical Neurology › Spinal Cord Injury Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- brain-computer interface, functional electrical stimulation, paralysis, spinal cord injury, motor cortex, neural prostheses, hand grasping, rhesus monkeys, tetraplegia, hand function recovery, prosthetic hand control
- MeSH terms
- Animals, Electric Stimulation, Electrodes, Implanted, Hand, Macaca mulatta, Microelectrodes, Motor Cortex, Movement, Muscles, Nerve Block, Paralysis, Quadriplegia, Spinal Cord Injuries, Hand Strength, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review