CoChat

An ultra-lightweight design for imperceptible plastic electronics

The DOI matches its Crossref record; 40 of the 41 references it cites were found in a registry or an index.

Abstract

Electronic devices have advanced from their heavy, bulky origins to become smart, mobile appliances. Nevertheless, they remain rigid, which precludes their intimate integration into everyday life. Flexible, textile and stretchable electronics are emerging research areas and may yield mainstream technologies. Rollable and unbreakable backplanes with amorphous silicon field-effect transistors on steel substrates only 3 μm thick have been demonstrated. On polymer substrates, bending radii of 0.1 mm have been achieved in flexible electronic devices. Concurrently, the need for compliant electronics that can not only be flexed but also conform to three-dimensional shapes has emerged. Approaches include the transfer of ultrathin polyimide layers encapsulating silicon CMOS circuits onto pre-stretched elastomers, the use of conductive elastomers integrated with organic field-effect transistors (OFETs) on polyimide islands, and fabrication of OFETs and gold interconnects on elastic substrates to realize pressure, temperature and optical sensors. Here we present a platform that makes electronics both virtually unbreakable and imperceptible. Fabricated directly on ultrathin (1 μm) polymer foils, our electronic circuits are light (3 g m(-2)) and ultraflexible and conform to their ambient, dynamic environment. Organic transistors with an ultra-dense oxide gate dielectric a few nanometres thick formed at room temperature enable sophisticated large-area electronic foils with unprecedented me…

Overview

Integrity signals

Registry

Crossref · 10.1038/nature12314

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 1

  1. Gonzalez, M. et al. in 11th International Conference on Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems (EuroSimE 2010) (eds Ernst, L. J. et al.) 1–7 (IEEE, 2010)

Cited by

See all 2,485

Metadata

Authors
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., Bauer, S., & Someya, T.
Affiliations
  • The University of Tokyo (JP)
  • Japan Science and Technology Agency (JP)
  • The University of Texas at Dallas (US)
  • Johannes Kepler University of Linz (AT)
Corresponding author
  • Kaltenbrunner, Martin
  • Someya, Takao
Venue
Nature
Published
2013-07
Volume
499
Issue
7459
Pages
458-463
ISSN
  • 0028-0836 (ISSN-L)
  • 1476-4687
OpenAlex
W2061453480
Cited by
2,485
References
41
Citations by year
2026: 79 · 2025: 138 · 2024: 161 · 2023: 151 · 2022: 182 · 2021: 238 · 2020: 246 · 2019: 240 · 2018: 259 · 2017: 247 · 2016: 197 · 2015: 212 · 2014: 124 · 2013: 11
FWCI
108.59
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Nature (publishedVersion)
  • PubMed (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Organic Electronics and Photovoltaics
Keywords
flexible electronics, conformal electronics, organic field-effect transistors, polymer substrates, tactile sensors, wearable sensors, stretchable electronics, mechanical stability, biomedical monitoring, polymer foils, health monitoring devices
MeSH terms
Delivery of Health Care, Electronics, Equipment Design, Fingers, Hot Temperature, Humans, Infrared Rays, Jaw, Models, Anatomic, Plastics, Transistors, Electronic, Pliability, Elastomers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.