Moving magnetoencephalography towards real-world applications with a wearable system
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
Imaging human brain function with techniques such as magnetoencephalography typically requires a subject to perform tasks while their head remains still within a restrictive scanner. This artificial environment makes the technique inaccessible to many people, and limits the experimental questions that can be addressed. For example, it has been difficult to apply neuroimaging to investigation of the neural substrates of cognitive development in babies and children, or to study processes in adults that require unconstrained head movement (such as spatial navigation). Here we describe a magnetoencephalography system that can be worn like a helmet, allowing free and natural movement during scanning. This is possible owing to the integration of quantum sensors, which do not rely on superconducting technology, with a system for nulling background magnetic fields. We demonstrate human electrophysiological measurement at millisecond resolution while subjects make natural movements, including head nodding, stretching, drinking and playing a ball game. Our results compare well to those of the current state-of-the-art, even when subjects make large head movements. The system opens up new possibilities for scanning any subject or patient group, with myriad applications such as characterization of the neurodevelopmental connectome, imaging subjects moving naturally in a virtual environment and investigating the pathophysiology of movement disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Although, there have been some studies on recording the MEG signal of moving participants in a MSR (44) and the unshielded static MEG measurements (35, 37), a MEG system that is both unshielded and movable remains to be developed.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [44]
The cited source says what the claim attributes to it.
In the citing paper
“OPMs are sensitive magnetic field sensors that do not require cryogenics.”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“These devices have enabled the design of flexible MEG sensor arrays, which can be placed closer to the scalp, and adapted to the requirements of individual studies and participants.”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“Using such shielding systems to attenuate the field at the OPM array has been shown to allow naturalistic motion during MEG studies of an individual subject [24,34]”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“Recently, ‘wearable’ MEG has been developed through the use of optically pumped magnetometers (OPMs) [24]”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Event-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Über das Elektrenkephalogramm des Menschen
Berger, H. (1929) · Archiv für Psychiatrie und Nervenkrankheiten · doi:10.1007/bf01797193 · Cited by 4,235
Frequency Dependence of Signal Power and Spatial Reach of the Local Field Potential
Leski, S., Lindén, H., Tetzlaff, T., Pettersen, K. H., & Einevoll, G. T. (2013) · PubMed · doi:10.18154/rwth-conv-084442 · Cited by 3,639
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561 · cited 1×
“In the static case, motion was less than ±1 cm whereas in the moving case it exceeded ±10 cm. Panel (ii) shows an image23,24 of beta modulation (pink overlay) whilst panel (iii) shows a time-frequency spectrogram (TFS) of oscillatory change.”
Abnormal neural oscillations and synchrony in schizophrenia
Uhlhaas, P. J., & Singer, W. (2010) · Nature Reviews Neuroscience · doi:10.1038/nrn2774 · Cited by 2,120 · cited 1×
“Although simple, this task has been applied widely, with beta modulation being used as a marker of brain plasticity18,19, psychosis20,21 and white matter degradation22.”
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
The Resolving Power of Gross Earth Data
Backus, G., & Gilbert, F. (1968) · Geophysical Journal International · doi:10.1111/j.1365-246x.1968.tb00216.x · Cited by 1,523
Large-scale cortical correlation structure of spontaneous oscillatory activity
Hipp, J. F., Hawellek, D. J., Corbetta, M., Siegel, M., & Engel, A. K. (2012) · Nature Neuroscience · doi:10.1038/nn.3101 · Cited by 1,113 · cited 1×
“For example, it is well known that efficient communication between spatially separate cortical regions is key to healthy brain function, and that neural oscillations help mediate such connectivity28,29.”
Research works printed but not linked: 1
- Robinson, S. & Vrba, J. in Recent Advances in Biomagnetism (eds Yoshimoto, T. et al.) 302–305 (Tohoku Univ. Press, 1998)
Cited by
Items 301–400 of 999
Mobile Electroencephalography for Studying Neural Control of Human Locomotion
Song, S., & Nordin, A. D. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.749017 · Cited by 31
“Although fNIRS can portably measure human brain hemodynamics, and advancements in MEG technologies that rely on novel optically pumped magnetometers (OPM) (Boto et al., 2018; Hill et al., 2020; Tierney et al., 2020) provide promising paths forward for studying real-world human brain dynamics, the low-cost portability…”
BackgroundCalibration of SQUID Magnetometers in Multichannel MCG System Based on Bi-Planar Coil
Yang, K. Y., Wu, D., Gao, W., Ni, T., Zhang, Q., Zhang, H., & Huang, D. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3150588 · Cited by 30
Relayed hyperpolarization for zero-field nuclear magnetic resonance
Dyke, E. V., Eills, J., Picazo‐Frutos, R., Федорович, Ш. К., Hu, Y., Budker, D., & Barskiy, D. A. (2022) · Science Advances · doi:10.1126/sciadv.abp9242 · Cited by 27
MEG-guided analysis of 7T-MRI in patients with epilepsy
Colon, A., van Osch, M. J. P., Buijs, M., van der Grond, J., Hillebrand, A., Schijns, O. E. M. G., Wagner, G. L., Ossenblok, P., Hofman, P. A. M., van Buchem, M. A., et al. (2018) · Seizure · doi:10.1016/j.seizure.2018.05.019 · Cited by 27
Increased segregation of functional networks in developing brains
He, W., Sowman, P. F., Brock, J., Etchell, A. C., Stam, C. J., & Hillebrand, A. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.055 · Cited by 32
Voigt-effect-based three-dimensional vector magnetometer
Pyragius, T., Florez, H. M., & Fernholz, T. (2019) · Physical Review A · doi:10.1103/physreva.100.023416 · Cited by 30
NeuroVAD: Real-Time Voice Activity Detection from Non-Invasive Neuromagnetic Signals
Dash, D., Ferrari, P., Dutta, S., & Wang, J. (2020) · Sensors · doi:10.3390/s20082248 · Cited by 27
“Although the current MEG machine is limited by non-portability, cost, and size; recent studies with optically pumped magnetometers (OPM) [20] are certainly promising towards overcoming these limitations.”
BackgroundAnalysis and suppression of magnetic field interference for SERF atomic magnetometer
Jia, L., Li, J., Song, X., Qi, S., Suo, Y., Long, T., Dai, Y., & Ning, X. (2024) · Measurement · doi:10.1016/j.measurement.2024.114266 · Cited by 26
Simultaneous whole-head electrophysiological recordings using EEG and OPM-MEG
Seedat, Z. A., Pier, K. S., Holmes, N., Rea, M., Al-Hilaly, L., Tierney, T. M., Embury, C. M., Pardington, R., Mullinger, K. J., Cross, J. H., et al. (2024) · Imaging Neuroscience · doi:10.1162/imag_a_00179 · Cited by 33
“Moreover, OPMs can be mounted in a lightweight helmet and move with the head, meaning that (assuming background field is controlled ( Holmes et al., 2018, 2019; Mellor et al., 2022; Robinson et al., 2022)) the MEG signal can be measured as a person moves ( Boto et al., 2018).”
BackgroundSelf-citationYuan, Z., Liu, Y., Lin, S., Li, C., Tang, J., Lei, G., & Zhai, Y. (2024) · Measurement · doi:10.1016/j.measurement.2024.115223 · Cited by 28
Device Modeling of MgO-Barrier Tunneling Magnetoresistors for Hybrid Spintronic-CMOS
Zuo, S., Nazarpour, K., & Heidari, H. (2018) · IEEE Electron Device Letters · doi:10.1109/led.2018.2870731 · Cited by 26
Cortical and Cerebellar Oscillatory Responses to Postural Instability in Parkinson's Disease
Bosch, T. J., Kammermeier, S., Groth, C. L., Leedom, M., Hanson, E. K., Berg-Poppe, P. J., & Singh, A. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.752271 · Cited by 27
“However, the complexity of the shielded MEG setup is severely limited when measuring activity in the postural context, with wearable and moving systems (68) only in early stages of development.”
BackgroundPoststroke Cognitive Impairment Research Progress on Application of Brain‐Computer Interface
Sun, X., Li, M., Li, Q., Yin, H.-N., Jiang, X., Li, H., Sun, Z., & Yang, T. (2022) · BioMed Research International · doi:10.1155/2022/9935192 · Cited by 31
A systematic review of the neural correlates of well-being reveals no consistent associations
de Vries, L. P., van de Weijer, M. P., & Bartels, M. (2023) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2023.105036 · Cited by 36
“helmet has been developed as well (Boto et al., 2018).”
Long, T., Han, B., Song, X., Suo, Y., Jia, L., & Ren, W. (2022) · Photonic Sensors · doi:10.1007/s13320-023-0684-y · Cited by 28
From cryogenic to on‐scalp magnetoencephalography for the evaluation of paediatric epilepsy
Feys, O., & Tiège, X. D. (2023) · Developmental Medicine & Child Neurology · doi:10.1111/dmcn.15689 · Cited by 31
“39 Alkali OPMs work with photodetectors to record the light intensity of a laser beam passing through a cell of gaseous rubidium-87 heated at approximately 150°C (rubidium- based-OPMs).”
BackgroundInfluentialHolmes, N., Bowtell, R. W., Brookes, M. J., & Taulu, S. (2023) · Sensors · doi:10.3390/s23146537 · Cited by 35
Self-citationSub-Sm-1 electromagnetic induction imaging with an unshielded atomic magnetometer
Deans, C., Marmugi, L., & Renzoni, F. (2020) · UCL Discovery (University College London) · Cited by 26
Yang, J., Zhang, X., Shi, M., Yuan, S., Wang, L., & Han, B. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2023.3314921 · Cited by 25
“For example, in research on magnetocardiograms [6], [7] and mag-netoencephalograms (MEG) [8], [9], it is important to directly measure the magnetic fields generated by the action potential in the heart and neural currents in the brain.”
BackgroundFree-induction-decay 4 He magnetometer using a multipass cell
Yi, K., Liu, Y., Wang, B., Xiao, W., Sheng, D., Peng, X., & Guo, H. M. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.014084 · Cited by 26
Imaging Magnetic Nanoparticle Distributions by Atomic Magnetometry-Based Susceptometry
Colombo, S., Lebedev, V., Tonyushkin, A., Pengue, S., & Weis, A. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2937670 · Cited by 26
Zhang, G., Zeng, H., Tan, G., & Lin, Q. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3156814 · Cited by 26
Zhang, S., Zhang, K., Zhou, Y., Ye, M., & Lu, J. (2022) · Optics Express · doi:10.1364/oe.464361 · Cited by 28
Rad, P. N., Behzadi, F., Yazdanfar, S.-A., Ghamari, H., Zabeh, E., & Lashgari, R. (2023) · HERD Health Environments Research & Design Journal · doi:10.1177/19375867221133135 · Cited by 29
“It measures the magnetic fields generated by the ionic current (Boto et al., 2018).”
BackgroundHansen, N. W., Webb, J. L., Troise, L., Olsson, C., Tomasevic, L., Brinza, O., Achard, J., Staacke, R., Kieschnick, M., Meijer, J., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-39539-y · Cited by 31
Disorganized Communication and Social Dysfunction in Schizophrenia: Emerging Concepts and Methods
Olarewaju, E., Dumas, G., & Palaniyappan, L. K. (2023) · Current Psychiatry Reports · doi:10.1007/s11920-023-01462-4 · Cited by 29
Feys, O., Ferez, M., Corvilain, P., Schuind, S., Rikir, E., Legros, B., Gaspard, N., Holmes, N., Brookes, M. J., Wens, V., et al. (2023) · Annals of Neurology · doi:10.1002/ana.26844 · Cited by 26
Self-citationPushing the boundaries of MEG based on optically pumped magnetometers towards early human life
Corvilain, P., Wens, V., Bourguignon, M., Capparini, C., Fourdin, L., Ferez, M., Feys, O., Tiège, X. D., & Bertels, J. (2025) · Imaging Neuroscience · doi:10.1162/imag_a_00489 · Cited by 35
Zero- to ultralow-field nuclear magnetic resonance
Barskiy, D. A., Blanchard, J. W., Budker, D., Eills, J., Pustelny, S., Федорович, Ш. К., Tayler, M. C. D., & Trabesinger, A. H. (2025) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2025.101558 · Cited by 24
OVERT SPEECH RETRIEVAL FROM NEUROMAGNETIC SIGNALS USING WAVELETS AND ARTIFICIAL NEURAL NETWORKS
Dash, D., Ferrari, P., Malik, S. I., & Wang, J. (2018) · IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip.2018.8646401 · Cited by 25
Data‐driven model optimization for optically pumped magnetometer sensor arrays
Duque‐Muñoz, L., Tierney, T. M., Meyer, S. S., Boto, E., Holmes, N., Roberts, G., Leggett, J., Vargas‐Bonilla, J. F., Bowtell, R. W., Brookes, M. J., et al. (2019) · Human Brain Mapping · doi:10.1002/hbm.24707 · Cited by 25
“First, the multi-channel system will suffer from cross talk which we estimate to be around 3% (Boto et al., 2018).”
BackgroundSelf-citationA Graphene‐Based Coaxial Fibrous Photofuel Cell Powered by Mine Gas
Yang, Z., Zhu, M., Niu, Y., Kozliak, E. I., Yao, B., Zhang, Y., Zhang, C., Qin, T., Jia, Y., & Li, Q. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201906813 · Cited by 24
Postoperative oscillatory brain activity as an add-on prognostic marker in diffuse glioma
Belgers, V., Numan, T., Kulik, S. D., Hillebrand, A., Hamer, P. C. D. W., Geurts, J. J. G., Reijneveld, J. C., Wesseling, P., Klein, M., Derks, J., et al. (2020) · Journal of Neuro-Oncology · doi:10.1007/s11060-019-03386-7 · Cited by 26
Transient dynamics of atomic spin in the spin-exchange-relaxation-free regime
Tang, J., Yin, Y., Zhai, Y., Zhou, B., Han, B., Yang, H., & Liu, G. (2021) · Optics Express · doi:10.1364/oe.418776 · Cited by 27
Effects of Different Head Models in Wearable OPM-MEG
Cao, F., An, N., Wang, W., Xu, W., Li, W., Wang, C., Xiang, M., Gao, Y., & Ning, X. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3192287 · Cited by 26
Single-trial classification of evoked responses to auditory tones using OPM- and SQUID-MEG
Iivanainen, J., Carter, T. R., Trumbo, M., McKay, J., Taulu, S., Wang, J., Stephen, J. M., Schwindt, P. D. D., & Borna, A. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acfcd9 · Cited by 24
“In contrast to SQUIDs, OPMs enable wearable sensor arrays detecting the field within millimeters from the scalp increasing the usability and spatial resolution of MEG (Iivanainen et al 2017, Boto et al 2018).”
Safar, K., Vandewouw, M. M., Sato, J., Devasagayam, J., Hill, R. M., Rea, M., Brookes, M. J., & Taylor, M. J. (2024) · Scientific Reports · doi:10.1038/s41598-024-56878-6 · Cited by 33
Self-citationKowalczyk, A., Bezsudnova, Y., Jensen, O. B., & Barontini, G. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117497 · Cited by 25
“Indeed, the ability to perform MEG recordings during movement is one of the most exciting features of OPM systems [6].”
BackgroundBadier, J., Schwartz, D., Bénar, C., Kanzari, K., Daligault, S., Romain, R., Mitryukovskiy, S. I., Fourcault, W., Josselin, V., Prado, M. L., et al. (2023) · eNeuro · doi:10.1523/eneuro.0222-23.2023 · Cited by 23
“OPMs do not require extreme cooling and can be placed near the scalp in a wearable system thus allowing the subject ’ s movement (Johnson et al., 2013; Boto et al., 2017; Iivanainen et al., 2017, Boto et al., 2018, 2022; Seymour et al., 2021).”
BackgroundInfluentialFeasibility of magnetomyography with optically pumped magnetometers in a mobile magnetic shield
Nordenström, S., Lebedev, V., Hartwig, S., Kruse, M., Marquetand, J. C., Broser, P. J., & Middelmann, T. (2024) · Scientific Reports · doi:10.1038/s41598-024-69829-y · Cited by 34
New Cognitive Neurotechnology Facilitates Studies of Cortical–Subcortical Interactions
Min, B., Hämäläinen, M., & Pantazis, D. (2020) · Trends in biotechnology · doi:10.1016/j.tibtech.2020.03.003 · Cited by 28
“Optically-pumped magnetometers (OPMs), magnetic field sensors that monitor the perturbation of spinpolarized alkali metal vapor, do not need cooling [32, 33], unlike SQUIDs, which operate at liquid helium or liquid nitrogen temperatures.”
BackgroundMagnetic noise calculation of mu-metal shields at extremely low frequencies for atomic devices
Ma, D., Ding, M., Lu, J., Zhao, J., Yang, K., Fang, X., Wang, K., Zhang, N., & Han, B. (2020) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/abbe4b · Cited by 23
Dual-Mode Dead-Zone-Free Double-Resonance Alignment-Based Magnetometer
Wang, H., Wu, T., Xiao, W., Wang, H., Peng, X., & Guo, H. M. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.15.024033 · Cited by 24
Automatic coregistration of MRI and on-scalp MEG
Gu, W., Ru, X., Li, D., He, K., Cui, Y., Sheng, J., & Gao, J. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2021.109181 · Cited by 26
Bioelectromagnetism in Human Brain Research: New Applications, New Questions
Groß, J., Junghöfer, M., & Wolters, C. H. (2021) · The Neuroscientist · doi:10.1177/10738584211054742 · Cited by 29
Saul, M. A., He, X., Black, S., & Charles, F. (2022) · Frontiers in Psychology · doi:10.3389/fpsyg.2021.568921 · Cited by 26
“Recent development in the field has seen designs of opticallypumped magnetometer, or OPM-MEG (Boto et al., 2018).”
MethodTriaxial Vector Operation in Near-Zero Field of Atomic Magnetometer With Femtotesla Sensitivity
Lu, F., Lu, J., Li, B., Yan, Y., Zhang, S., Yin, K., Ye, M., & Han, B. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3162282 · Cited by 27
OMMR: Co-registration toolbox of OPM-MEG and MRI
Cao, F., An, N., Xu, W., Wang, W., Li, W., Wang, C., Yang, Y., Xiang, M., Gao, Y., & Ning, X. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.984036 · Cited by 28
“This results in lower cost and higher signal strength for OPM-MEG (Iivanainen et al., 2017; Boto et al., 2018).”
BackgroundWang, K., Ma, D., Li, S., Gao, Y., & Sun, J. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.114055 · Cited by 23
Demagnetization Parameters Evaluation of Magnetic Shields Based on Anhysteretic Magnetization Curve
Yang, J., Shi, M., Zhang, X., Ma, Y., Liu, Y., Yuan, S., & Han, B. (2023) · Materials · doi:10.3390/ma16155238 · Cited by 24
“In recent decades, the development of increasingly sensitive magnetometers [1,2] has led to numerous applications of extremely weak magnetic field measurement in fundamental physics [3,4] as well as medical and biomedical science [5,6].”
BackgroundGradient phase and amplitude errors in atomic magnetic gradiometers for biomagnetic imaging systems
Yuan, Z., Lin, S., Liu, Y., Tang, J., Long, T., & Zhai, Y. (2024) · iScience · doi:10.1016/j.isci.2024.109250 · Cited by 24
“20,24,25 These structures allow more channels to be arranged in a limited space, facilitating the flexible configuration of OPM gradi-ometers.”
BackgroundNierula, B., Stephani, T., Bailey, E., Kaptan, M., Pohle, L.-M. G., Horn, U., Mouraux, A., Maeß, B., Villringer, A., Curio, G., et al. (2024) · PLoS Biology · doi:10.1371/journal.pbio.3002828 · Cited by 28
“In terms of comparison with other neuroimaging methods for assessing the entire CNS, we note that only fMRI and MEG (based on optically pumped magnetometers (OPMs) [102,103]) have so far been used for simultaneous assessment of corticospinal processes.”
Whole-head OPM-MEG enables noninvasive assessment of functional connectivity
Jas, M., Jones, S. R., & Hämäläinen, M. (2021) · Trends in Neurosciences · doi:10.1016/j.tins.2021.04.006 · Cited by 23
Feys, O., Corvilain, P., Labyt, É., Mahmoudzadeh, M., Routier, L., Sculier, C., Holmes, N., Brookes, M. J., Goldman, S., Romain, R., et al. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1284262 · Cited by 24
Self-citationYuan, S.-J., Meng, W., Du, A., Cao, X., Zhao, Y. S., Wang, J., & Jiang, L. (2019) · Chinese Journal of Polymer Science · doi:10.1007/s10118-019-2286-0 · Cited by 22
Effect of gaps on magnetic noise of cylindrical ferrite shield
Lu, J., Sun, C., Ma, D., Yang, K., Zhao, J., Han, B., Quan, W., Zhang, N., & Ding, M. (2021) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/abf169 · Cited by 22
Design of Highly Linear Gradient Field Coils Based on an Improved Target-Field Method
Zhao, F., Wang, J., Lu, F., Wu, W., Han, B., Zhou, B., & Zhou, X. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3075445 · Cited by 22
Aung, T., Tenney, J. R., & Bagic, A. I. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2022.831546 · Cited by 23
“5 (18–48) 14 (17–24) 181 (33-488) 26 No (MEG−275) (600Hz) Connectivity— source level Beamformer (LCMV)(1– 150Hz),”
BackgroundLi, L., Tang, J., Zhao, B., Li, C., Zhou, B., & Zhai, Y. (2022) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ac9cea · Cited by 23
Experimental studies on the performance of magnetic shields under different magnetization conditions
Yang, J., Zhang, X., Shi, M., Yuan, S., Zhang, L., Wang, L., & Han, B. (2023) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/acc412 · Cited by 22
“measurement of extremely weak magnetic fields, including fundamental physics [3, 4], paleomagnetism [5, 6] and biomedical science [7, 8].”
Optical pumping enhancement of a free-induction-decay magnetometer
Hunter, D., Mrozowski, M. S., McWilliam, A., Ingleby, S. J., Dyer, T., Griffin, P. F., & Riis, E. (2023) · Journal of the Optical Society of America B · doi:10.1364/josab.501086 · Cited by 27
“Accordingly, they offer an attractive alternative to superconducting quantum interference devices (SQUIDs), particularly in MEG applications, as these compact and flexible devices can be easily integrated into custom mounting hardware [10].”
BackgroundTang, J., Qiu, S., Zhang, L., Sun, J., & Zhou, X. (2023) · Measurement · doi:10.1016/j.measurement.2023.113904 · Cited by 23
Hardware-Based Interference Suppression Techniques for OPM-MEG: A Review
Jia, L., Li, J., Song, X., Ning, X., Yang, J., Qi, S., Long, T., Wu, Z., & Wang, R. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3509679 · Cited by 27
Combining video telemetry and wearable MEG for naturalistic imaging
O’Neill, G. C., Seymour, R. A., Mellor, S., Alexander, N., Tierney, T. M., Bernachot, L., Hnazaee, M. F., Spedden, M. E., Timms, R. C., Bush, D., et al. (2025) · Imaging Neuroscience · doi:10.1162/imag_a_00495 · Cited by 30
“…( Roberts et al., 2019) and has been used to reliably image neural processes while participants move large (>1 m) distances ( Holmes et al., 2023b; Mellor et al., 2023; Seymour et al., 2021), play a ball-game against each other ( Holmes et al., 2023a), or simply drink tea ( Boto et al., 2018).”
Self-citationFeys, O., Wens, V., Depondt, C., Rikir, E., Gaspard, N., Paesschen, W. V., Aeby, A., Bodart, O., Carrette, E., Holmes, N., et al. (2025) · Epilepsia · doi:10.1111/epi.18439 · Cited by 25
“2 The advent of miniaturized optically pumped mag-netometers (OPMs) paved the way to the development of on-scalp MEG 3,4 with a possible increase in signal- to-noise ratio (SNR) due to reduced brain- to-sensor distance 5 and higher lifespan/movement compliance.”
Self-citationIndium Tin Oxide Non-Magnetic Heating Film for Miniaturized SERF Gradient Magnetometer
Liu, Z., Zhang, C., Yuan, H., Yin, K., Yang, Y., Yan, Y., Wang, Y., Zhou, B., Ning, X., & Han, B. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3076133 · Cited by 22
Nami, M., Thatcher, R. W., Kashou, N. H., Lopes, D., Lobo, M., Bolanos, J. F., Morris, K., Sadri, M., Bustos, T., Sanchez, G. E., et al. (2022) · Journal of Alzheimer s Disease · doi:10.3233/jad-215240 · Cited by 23
“Especially with MEG and fMRI, the costly nature of use reduces their applicability in general screening but does not preclude their use in scenarios where more data is required to [81, 94].”
In Situ Measurement of Nonorthogonal Angles of a Three-Axis Vector Optically Pumped Magnetometer
Li, S., Lu, J., Ma, D., Wang, K., Gao, Y., Sun, C., & Han, B. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3144737 · Cited by 21
Multiple Source Detection Based on Spatial Clustering and Its Applications on Wearable OPM-MEG
An, N., Cao, F., Li, W., Wang, W., Xu, W., Wang, C., Gao, Y., Xiang, M., & Ning, X. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3161830 · Cited by 22
“The flexible sensor configuration enables the MEG to be wearable, movable, and suitable for people with different head circumferences, especially for children [8]–[10].”
BackgroundLu, F., Li, B., Lu, J., Ye, M., Ning, X., & Han, B. (2022) · Optics Letters · doi:10.1364/ol.465832 · Cited by 21
Grasso‐Cladera, A., Costa‐Cordella, S., Rossi, A., Fuchs, N. F., & Parada, F. J. (2022) · Adaptive Behavior · doi:10.1177/10597123211072613 · Cited by 23
“Results obtained using OPM-based MEG indicate that data quality is comparable to that of traditional MEG, even in the presence of neck and head movements (Boto et al., 2018).”
BackgroundMethodPark, T., Jeong, J.-H., Chung, Y. A., Yeo, S.-H., & Kim, H. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.107127 · Cited by 21
Femtotesla 4 He magnetometer with a multipass cell
Liu, Y., Peng, X., Wang, H., Wang, B., Yi, K., Sheng, D., & Guo, H. M. (2022) · Optics Letters · doi:10.1364/ol.471557 · Cited by 22
Automatic co-registration of OPM-MEG and MRI using a 3D laser scanner
Gao, Z., Cao, F., An, N., & Ning, X. (2023) · Measurement · doi:10.1016/j.measurement.2023.113729 · Cited by 22
The After-Glow of Flow: Neural Correlates of Flow in Musicians
Tan, J. S., Luft, C. D. B., & Bhattacharya, J. (2023) · Creativity Research Journal · doi:10.1080/10400419.2023.2277042 · Cited by 27
“Finally, there are exciting promises offered by the newly developed wearable magnetoencephalography system that allows free and natural movement (Boto et al., 2018), while recording brain activity with high temporal and spatial precision.”
Elliptically polarized laser-pumped Mx magnetometer towards applications at room temperature
Su, S., Zhang, G., Bi, X., He, X., Zheng, W., & Lin, Q. (2019) · Optics Express · doi:10.1364/oe.27.033027 · Cited by 22
Frequency tunable resonant magnetoelectric sensors for the detection of weak magnetic field
Su, J., Niekiel, F., Fichtner, S., Kirchhof, C., Meyners, D., Quandt, E., Wagner, B., & Lofink, F. (2020) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ab8dd0 · Cited by 21
Towards an Objective Evaluation of EEG/MEG Source Estimation Methods: The Linear Tool KitPreprint
Hauk, O., Stenroos, M., & Treder, M. S. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/672956 · Cited by 21
“(Boto et al., 2018; Iivanainen et al., 2017; Tierney et al., 2019).”
Functionalized millimeter-scale vapor cells for alkali-metal spectroscopy and magnetometry
Raghavan, H., Tayler, M. C. D., Mouloudakis, K., Rae, R., Lähteenmäki, S., Zetter, R., Laine, P., Haesler, J., Balet, L. P., Overstolz, T., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.22.044011 · Cited by 25
“With appropriate microfabrication 4–6 , optics and electronics, alkali vapor technologies can be implemented as miniaturized atomic devices 7,8 including chip-scale atomic clocks 9 , wearable magnetometer arrays 10 and portable inertial navigation systems 11 .”
Jia, L., Li, J., Song, X., Qi, S., Long, T., Wu, Z., Wang, R., & Ning, X. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3522373 · Cited by 36
A fully integrated whole-head helium OPM MEG: a performance assessment compared to cryogenic MEG
Bonnet, M., Schwartz, D., Gutteling, T. P., Daligault, S., & Labyt, É. (2025) · Frontiers in Medical Technology · doi:10.3389/fmedt.2025.1548260 · Cited by 21
“Numerous studies have assessed the performance of alkali OPMs (7, 8) on healthy volunteers (9 – 13) and patients (14 – 16).”
Gradiometer Using Separated Diamond Quantum Magnetometers
MASUYAMA, Y., Suzuki, K., Hekizono, A., Iwanami, M., Hatano, M., Iwasaki, T., & Ohshima, T. (2021) · Sensors · doi:10.3390/s21030977 · Cited by 23
Progress and applications of quantum precision measurement based on SERF effect
Zhai, Y., Yue, Z., Li, L., & Liu, Y. (2022) · Frontiers in Physics · doi:10.3389/fphy.2022.969129 · Cited by 23
“In 2022, An et al. proposed a new parameterized method to estimate the number of magnetic sources and locate multiple magnetic sources, which was used in the 31-channel MEG system.”
BackgroundMethodInfluentialMa, N., Duan, L., Ma, D., Lu, J., Xing, B., Li, J., & Han, B. (2022) · Optics Express · doi:10.1364/oe.474777 · Cited by 20
Optimising the sensing volume of OPM sensors for MEG source reconstruction
Bezsudnova, Y., Koponen, L. M., Barontini, G., Jensen, O. B., & Kowalczyk, A. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119747 · Cited by 24
“number of works demonstrated that OPMs enable the study of previously difficult to detect biomagnetic signals in human and animal neurophysiology [11, 13, 14, 15, 16, 17, 18].”
Markov Noise in Atomic Spin Gyroscopes: Analysis and Suppression Based on Allan Deviation
Pei, H., Fan, W., Du, P., Zhang, K., Yuan, L., & Quan, W. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3246473 · Cited by 20
Suppression of modulation-magnetic-fields crosstalk for single-beam optically-pumped magnetometers
Suo, Y., Song, X., Jiang, L., Jia, L., Long, T., & Wu, Z. (2023) · Measurement · doi:10.1016/j.measurement.2023.113059 · Cited by 20
Li, L., Tang, J., Zhao, B., Cao, L., Zhang, Y., & Zhai, Y. (2023) · Measurement · doi:10.1016/j.measurement.2023.113161 · Cited by 22
Hybrid optimal design method for magnetic field coils under magnetic shielding boundary
Wu, Z., Pang, H., Wang, Z., Fan, W., Liu, F., Pei, H., & Quan, W. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114464 · Cited by 20
Design of locally arranged sensor arrays in wearable OPM-MEG based on sensor volume constraints
Wang, W., Cao, F., An, N., Wen, L., Xu, W., Wang, C., Gao, Z., Yu, D., Gao, Y., & Ning, X. (2024) · Measurement · doi:10.1016/j.measurement.2024.114373 · Cited by 21
Cooperative Spin Amplifier for Enhanced Quantum Sensing
Xu, M., Jiang, M., Wang, Y., Su, H., Huang, Y., & Peng, X. (2024) · Physical Review Letters · doi:10.1103/physrevlett.133.133202 · Cited by 24
Zhao, J., Liu, G., Lu, J., Yang, K., Ma, D., Xing, B., Han, B., & Ding, M. (2019) · IEEE Access · doi:10.1109/access.2019.2954103 · Cited by 22
Field, D. T., Biagi, N., & Inman, L. A. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116679 · Cited by 21
“This is not possible with fMRI methods that require the participants to remain still, but might be achieved using near infrared spectroscopy (NIRS) to measure cerebral blood flow (Ferrari and Quaresima, 2012), or by exploiting new developments in wearable magnetoencephalography (MEG) systems that allow freedom for par…”
BackgroundSpin Hyperpolarization in Modern Magnetic ResonancePreprint
Eills, J., Budker, D., Cavagnero, S., Chekmenev, E. Y., Elliott, S. J., Jannin, S., Lesage, A., Matysik, J., Meersmann, T., Prisner, T. F., et al. (2022) · ChemRxiv · doi:10.26434/chemrxiv-2022-p7c9r · Cited by 20
Magnetic Source Imaging and Infant MEG: Current Trends and Technical Advances
Kao, C., & Zhang, Y. (2019) · Brain Sciences · doi:10.3390/brainsci9080181 · Cited by 19
Li, J., Sun, S., Li, X., Feng, Y., Zhang, Y., Huang, X., Du, P., Zhang, J., Chen, L., Sanz, Á. S., et al. (2024) · ACS Photonics · doi:10.1021/acsphotonics.4c01694 · Cited by 19
Adaptive cold-atom magnetometry mitigating the trade-off between sensitivity and dynamic range
Ma, Z., Han, C., Tan, Z., He, H.-N., Shi, S., Kang, X., Wu, J., Huang, J., Lü, B., & Lee, C. (2025) · Science Advances · doi:10.1126/sciadv.adt3938 · Cited by 23
Shi, M., Zhang, L., Zhang, X., Yang, J., Ma, Y., Zhang, A., & Yuan, S. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3555703 · Cited by 19
Dash, D., Ferrari, P., Heitzman, D., & Wang, J. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857874 · Cited by 21
“Fortunately, continuous advancements of cost-effective MEG acquisition techniques including a recently developed movable MEG [28] strengthen the potential of MEG for BCI applications in the future.”
BackgroundChip-Scale Ultra-Low Field Atomic Magnetometer Based on Coherent Population Trapping
Hong, H.-G., Park, S. E., Lee, S.-B., Heo, M.-S., Park, J., Kim, T. H., Kim, H. Y., & Kwon, T. Y. (2021) · Sensors · doi:10.3390/s21041517 · Cited by 19
“Recently CSAMs have been integrated with platforms of real-world applications, such as military systems [12] and wearable medical-imaging instruments [13,14].”
Background
Metadata
- Authors
- Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., Barnes, G. R., Bowtell, R., & Brookes, M. J.
- Affiliations
- University of Nottingham (GB)
- QuSpin (United States) (US)
- Wellcome Centre for Human Neuroimaging (GB)
- Corresponding author
- Brookes, Matthew J.
- ORCID
- Venue
- Nature
- Published
- 2018-03
- Volume
- 555
- Issue
- 7698
- Pages
- 657-661
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- PMC
- PMC6063354
- OpenAlex
- W2791548393
- Cited by
- 1,377
- References
- 51
- Citations by year
- 2026: 174 · 2025: 236 · 2024: 196 · 2023: 175 · 2022: 175 · 2021: 161 · 2020: 111 · 2019: 107 · 2018: 40
- FWCI
- 48.05
- Type
- journal article
- Language
- en
- Open access
- Licence
- other-oa
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Nottingham ePrints (University of Nottingham) (acceptedVersion)
- University of Birmingham Research Portal (University of Birmingham) (acceptedVersion, other-oa)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Repository@Nottingham (University of Nottingham) (acceptedVersion, other-oa)
- Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Funders
- Wellcome Trust (203147/Z/16/Z, 203257/Z/16/Z, 203257BARNES, 203257/B/16/Z)
- National Institutes of Health (203257/Z/16/Z, 203257/B/16/Z)
- Medical Research Council (MR/K005464/1, MR/M006301/1, 203147/Z/16/Z)
- Engineering and Physical Sciences Research Council (MR/K005464/1, 1652749, 203147/Z/16/Z, 203257/B/16/Z, EP/M013294/1, EP/M013294, 203257/Z/16/Z)
- National Institute of Mental Health (R44MH110288)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R44HD074495)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- quantum sensors, movement disorders, brain function imaging
- MeSH terms
- Wearable Electronic Devices, Adult, Drinking, Female, Head, Humans, Movement, Sports, Magnetoencephalography, Magnetic Fields
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.