Moving magnetoencephalography towards real-world applications with a wearable system
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
Imaging human brain function with techniques such as magnetoencephalography typically requires a subject to perform tasks while their head remains still within a restrictive scanner. This artificial environment makes the technique inaccessible to many people, and limits the experimental questions that can be addressed. For example, it has been difficult to apply neuroimaging to investigation of the neural substrates of cognitive development in babies and children, or to study processes in adults that require unconstrained head movement (such as spatial navigation). Here we describe a magnetoencephalography system that can be worn like a helmet, allowing free and natural movement during scanning. This is possible owing to the integration of quantum sensors, which do not rely on superconducting technology, with a system for nulling background magnetic fields. We demonstrate human electrophysiological measurement at millisecond resolution while subjects make natural movements, including head nodding, stretching, drinking and playing a ball game. Our results compare well to those of the current state-of-the-art, even when subjects make large head movements. The system opens up new possibilities for scanning any subject or patient group, with myriad applications such as characterization of the neurodevelopmental connectome, imaging subjects moving naturally in a virtual environment and investigating the pathophysiology of movement disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Although, there have been some studies on recording the MEG signal of moving participants in a MSR (44) and the unshielded static MEG measurements (35, 37), a MEG system that is both unshielded and movable remains to be developed.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [44]
The cited source says what the claim attributes to it.
In the citing paper
“OPMs are sensitive magnetic field sensors that do not require cryogenics.”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“These devices have enabled the design of flexible MEG sensor arrays, which can be placed closer to the scalp, and adapted to the requirements of individual studies and participants.”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“Using such shielding systems to attenuate the field at the OPM array has been shown to allow naturalistic motion during MEG studies of an individual subject [24,34]”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“Recently, ‘wearable’ MEG has been developed through the use of optically pumped magnetometers (OPMs) [24]”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Event-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Über das Elektrenkephalogramm des Menschen
Berger, H. (1929) · Archiv für Psychiatrie und Nervenkrankheiten · doi:10.1007/bf01797193 · Cited by 4,235
Frequency Dependence of Signal Power and Spatial Reach of the Local Field Potential
Leski, S., Lindén, H., Tetzlaff, T., Pettersen, K. H., & Einevoll, G. T. (2013) · PubMed · doi:10.18154/rwth-conv-084442 · Cited by 3,639
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561 · cited 1×
“In the static case, motion was less than ±1 cm whereas in the moving case it exceeded ±10 cm. Panel (ii) shows an image23,24 of beta modulation (pink overlay) whilst panel (iii) shows a time-frequency spectrogram (TFS) of oscillatory change.”
Abnormal neural oscillations and synchrony in schizophrenia
Uhlhaas, P. J., & Singer, W. (2010) · Nature Reviews Neuroscience · doi:10.1038/nrn2774 · Cited by 2,120 · cited 1×
“Although simple, this task has been applied widely, with beta modulation being used as a marker of brain plasticity18,19, psychosis20,21 and white matter degradation22.”
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
The Resolving Power of Gross Earth Data
Backus, G., & Gilbert, F. (1968) · Geophysical Journal International · doi:10.1111/j.1365-246x.1968.tb00216.x · Cited by 1,523
Large-scale cortical correlation structure of spontaneous oscillatory activity
Hipp, J. F., Hawellek, D. J., Corbetta, M., Siegel, M., & Engel, A. K. (2012) · Nature Neuroscience · doi:10.1038/nn.3101 · Cited by 1,113 · cited 1×
“For example, it is well known that efficient communication between spatially separate cortical regions is key to healthy brain function, and that neural oscillations help mediate such connectivity28,29.”
Research works printed but not linked: 1
- Robinson, S. & Vrba, J. in Recent Advances in Biomagnetism (eds Yoshimoto, T. et al.) 302–305 (Tohoku Univ. Press, 1998)
Cited by
Items 101–200 of 999
Laminar dynamics of high amplitude beta bursts in human motor cortex
Bonaiuto, J. J., Little, S., Neymotin, S. A., Jones, S. R., Barnes, G. R., & Bestmann, S. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118479 · Cited by 76
Self-citationImaging Cerebral Activity in Amyotrophic Lateral Sclerosis
Proudfoot, M., Bede, P., & Turner, M. R. (2019) · Frontiers in Neurology · doi:10.3389/fneur.2018.01148 · Cited by 84
The Neuroscience of Dance: A Conceptual Framework and Systematic Review
Elst, O. F. V., Foster, N. H., Vuust, P., Keller, P. E., & Kringelbach, M. L. (2023) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2023.105197 · Cited by 121
“Significant progress has also been made using MEG sensors which allow for some movement (Boto et al., 2018). fMRI is even more restrictive as the person must be lying down, and any movement may therefore only approximate dance.”
BackgroundOptically pumped magnetoencephalography in epilepsy
Vivekananda, U., Mellor, S., Tierney, T. M., Holmes, N., Boto, E., Leggett, J., Roberts, G., Hill, R. M., Vladimir Litvak, A., Brookes, M. J., et al. (2020) · Annals of Clinical and Translational Neurology · doi:10.1002/acn3.50995 · Cited by 78
Self-citationWang, J., Fan, W., Yin, K., Yan, Y., Zhou, B., & Song, X. (2020) · Physical Review A · doi:10.1103/physreva.101.053427 · Cited by 77
Jodko-Władzińska, A., Wildner, K., Pałko, T., & Władziński, M. (2020) · Sensors · doi:10.3390/s20164563 · Cited by 76
“Moving magnetoencephalography [34] and exercise magnetocardiography [35] with OPMs were proven to be possible.”
BackgroundContinuous High-Sensitivity and High-Bandwidth Atomic Magnetometer
Li, R., Baynes, F. N., Luiten, A. N., & Perrella, C. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.14.064067 · Cited by 78
“…magnetometers find use across a broad swathe of applications, including geophysical exploration [1,2], magnetocardiography (MCG) and magnetoencephalography (MEG) [3–5], detection of nuclear magnetic resonance (NMR), nuclear quadrupole resonance (NQR), and magnetic induction tomography (MIT) [6–9].”
Hybrid Optimal Design of Biplanar Coils With Uniform Magnetic Field or Field Gradient
Wang, J., Song, X., Zhou, W., Le, Y., & Ning, X. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.3032868 · Cited by 72
Ma, N., Fang, X., Zhang, Y., Xing, B., Duan, L., Lu, J., Han, B., & Ma, D. (2024) · Optics Express · doi:10.1364/oe.530764 · Cited by 77
Tierney, T. M., Holmes, N., Meyer, S. S., Boto, E., Roberts, G., Leggett, J., Buck, S., Duque‐Muñoz, L., Vladimir Litvak, A., Bestmann, S., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.07.035 · Cited by 73
Self-citationFemtotesla Direct Magnetic Gradiometer Using a Single Multipass Cell
Lucivero, V. G., Lee, W., Dural, N., & Romalis, M. V. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.15.014004 · Cited by 77
Wearable OPM-MEG: a changing landscape for epilepsy
Pedersen, M., Abbott, D. F., & Jackson, G. D. (2022) · Epilepsia · doi:10.1111/epi.17368 · Cited by 68
Cavity-enhanced microwave readout of a solid-state spin sensor
Eisenach, E. R., Barry, J. F., O’Keeffe, M. F., Schloss, J. M., Steinecker, M., Englund, D. R., & Braje, D. (2021) · Nature Communications · doi:10.1038/s41467-021-21256-7 · Cited by 93
Blanchard, J. W., Wu, T., Eills, J., Hu, Y., & Budker, D. (2020) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2020.106723 · Cited by 75
Comparing MEG and high-density EEG for intrinsic functional connectivity mapping
Coquelet, N., Tiège, X. D., Destoky, F., Roshchupkina, L., Bourguignon, M., Goldman, S., Peigneux, P., & Wens, V. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116556 · Cited by 68
Webb, J. L., Troise, L., Hansen, N. W., Olsson, C., Wojciechowski, A. M., Achard, J., Brinza, O., Staacke, R., Kieschnick, M., Meijer, J., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-81828-x · Cited by 84
Optically Pumped Magnetometers Recent Advances and Applications in Biomagnetism: A Review
Zhao, B., Li, L., Zhang, Y., Tang, J., Liu, Y., & Zhai, Y. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3297109 · Cited by 80
“Adapted from [30] and [31] under a Creative Commons license.”
BackgroundMethodInfluentialManyukhina, V. O., Prokofyev, A. O., Galuta, I. A., Goiaeva, D. E., Obukhova, T. S., Schneiderman, J. F., Altukhov, D., Stroganova, T. A., & Orekhova, E. V. (2022) · Molecular Autism · doi:10.1186/s13229-022-00498-2 · Cited by 83
“Thirdly, the new and rapidly developing technology of ‘on-scalp’ MEG (65-67) may help to obtain equally high-quality data in all parts of the head, including the frontal areas, which are typically positioned furthest away from the sensors in ‘conventional’ MEG systems.”
BackgroundNann, M., Cordella, F., Trigili, E., Lauretti, C., Bravi, M., Miccinilli, S., Catalan, J. M., Badesa, F. J., Crea, S., Bressi, F., et al. (2020) · IEEE Systems Journal · doi:10.1109/jsyst.2020.3021485 · Cited by 74
“quantum sensors [34], [35], may overcome the current constraint of limited spatial resolution when recording brain oscillatory activity noninvasively.”
BackgroundProtecting Privacy of Users in Brain-Computer Interface Applications
Agarwal, A., Dowsley, R., McKinney, N. D., Wu, D., Lin, C., Cock, M. D., & Nascimento, A. C. A. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2926965 · Cited by 90
“…consumer-grade BCI devices for measuring brain activity in the form of EEG signals, as well as so-called BCI App Stores to facilitate adoption of the BCI headsets [8], and efforts are underway to make the more informative magnetoencephalography (MEG) brain scanners wearable in practice [19].”
BackgroundZhao, J., Ding, M., Lu, J., Yang, K., Ma, D., Yao, H., Han, B., & Liu, G. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2905308 · Cited by 70
“Since then, much progress was made with applications that used atomic magnetometers in the SERF regime, such as fundamental physics research [3], materials characterization [4], nuclear quadrupole resonance for detection of explosives [5], magnetic source imaging (MSI) [6], and especially magnetoencephalography (MEG)…”
Optimal Inverse Design of Magnetic Field Profiles in a Magnetically Shielded Cylinder
Packer, M., Hobson, P. J., Holmes, N., Leggett, J., Glover, P. M., Brookes, M. J., Bowtell, R. W., & Fromhold, T. M. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.14.054004 · Cited by 70
“These include quantum sensing of gravity and gravity gradients for geophysical survey and mapping [1–4]; atomic magnetometry [5–7] for applications including material characterization [8] and magnetoencephalography [9,10]; noise reduction in fundamental physics experiments [11,12] such as timing using high-precision a…”
MethodSelf-citationFLUX: A pipeline for MEG analysis
Ferrante, O., Liu, L., Minarik, T., Górska, U., Ghafari, T., Luo, H., & Jensen, O. B. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119047 · Cited by 78
Studying parent-child interaction with hyperscanning
Nguyen, T., Bánki, A., Marková, G., & Hoehl, S. (2020) · Progress in brain research · doi:10.1016/bs.pbr.2020.05.003 · Cited by 85
Fourcault, W., Romain, R., Le Gal, G., Bertrand, F., Josselin, V., Le Prado, M., Labyt, E., & Palacios-Laloy, A. (2021) · Optics Express · doi:10.1364/oe.420031 · Cited by 65
Optimal atomic quantum sensing using electromagnetically-induced-transparency readout
Meyer, D. H., O’Brien, C., Fahey, D. P., Cox, K. C., & Kunz, P. D. (2021) · Physical Review A · doi:10.1103/physreva.104.043103 · Cited by 69
Homölle, S., & Oostenveld, R. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108378 · Cited by 65
Comparing the potential of MEG and EEG to uncover brain tracking of speech temporal envelope
Destoky, F., Philippe, M., Bertels, J., Verhasselt, M., Coquelet, N., Ghinst, M. V., Wens, V., Tiège, X. D., & Bourguignon, M. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.006 · Cited by 66
Zhang, G., Huang, S.-J., Xu, F., Hu, Z., & Lin, Q. (2019) · Optics Express · doi:10.1364/oe.27.000597 · Cited by 67
He, K., Wan, S., Sheng, J., Liu, D., Wang, C., Li, D., Qin, L., Luo, S., Qin, J., & Gao, J. (2019) · Review of Scientific Instruments · doi:10.1063/1.5066250 · Cited by 71
Zero-field nuclear magnetic resonance of chemically exchanging systems
Barskiy, D. A., Tayler, M. C. D., Marco‐Rius, I., Kurhanewicz, J. V., Vigneron, D. B., Erünsal, S. Ç., Aydoğdu, A., Reh, M., Pravdivtsev, A. N., Hövener, J., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-10787-9 · Cited by 71
Lin, C., Tierney, T. M., Holmes, N., Boto, E., Leggett, J., Bestmann, S., Bowtell, R. W., Brookes, M. J., Barnes, G. R., & Miall, R. C. (2019) · The Journal of Physiology · doi:10.1113/jp277899 · Cited by 69
Self-citationTransforming and comparing data between standard SQUID and OPM-MEG systems
Marhl, U., Jodko-Władzińska, A., Brühl, R., Sander, T. H., & Jazbinšek, V. (2022) · PLoS ONE · doi:10.1371/journal.pone.0262669 · Cited by 70
“For this reason, exploring the applicability of an OPM-MEG setup with a limited sensor count is of great importance, and its usefulness was demonstrated in [10].”
BackgroundMethodYang, P., Liu, Z., Qin, S., Hu, J., Yuan, S., Wang, Z. L., & Chen, X. (2024) · Science Advances · doi:10.1126/sciadv.adr9139 · Cited by 70
Long, T., Song, X., Han, B., Suo, Y., & Jia, L. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3331425 · Cited by 83
Tackling Epilepsy With High-definition Precision Medicine: A Review
KEARNEY, H. F., Byrne, S., Cavalleri, G. L., & Delanty, N. (2019) · JAMA Neurology · doi:10.1001/jamaneurol.2019.2384 · Cited by 71
Single-Beam Atomic Magnetometer Based on the Transverse Magnetic-Modulation or DC-Offset
Liu, G., Tang, J., Yin, Y., Wang, Y., Zhou, B., & Han, B. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2973201 · Cited by 64
“magnetic imaging, this opens up the possibility of noninvasively mapping of the human brain, while subjects are free to move and interact with the real world across all ages and patient groups [13], [14].”
BackgroundShen, F. X., Wolf, S. M., Bhavnani, S., Deoni, S., Elison, J. T., Fair, D. A., Garwood, M., Gee, M. S., Geethanath, S., Kay, K., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118210 · Cited by 73
“…should also consider advances in mobile positron emission tomography (PET) ( Bauer et al., 2016 ), mobile magnetoencephalography (MEG) (Bosso 2020; Boto et al., 2018 , 2019 ), functional near-infrared spectroscopy (fNIRS) ( Baker et al., 2017a , b ; Blasi et al., 2019 ), and high-density diffuse…”
BackgroundFang, X., Wei, K., Zhai, Y., Zhao, T., Chen, X., Zhou, M., Liu, Y., Ma, D., & Xiao, Z. (2022) · Optics Express · doi:10.1364/oe.447041 · Cited by 64
Scalp attached tangential magnetoencephalography using tunnel magneto-resistive sensors
Kanno, A., Nakasato, N., Oogane, M., Fujiwara, K., Nakano, T., Arimoto, T., Matsuzaki, H., & Ando, Y. (2022) · Scientific Reports · doi:10.1038/s41598-022-10155-6 · Cited by 70
Fiber-Coupled Diamond Magnetometry with an Unshielded Sensitivity of 30 pT / Hz
Graham, S. M., Rahman, A., Munn, L., Patel, R. L., Newman, A. J., Stephen, C. J., Colston, G., Nikitin, A. P., Edmonds, A. M., Twitchen, D. J., et al. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.044042 · Cited by 66
“Magnetoencephalography (MEG) would be a possible application if femtotesla sensitivities could be obtained [69, 70].”
BackgroundUltrasensitive SERF atomic magnetometer with a miniaturized hybrid vapor cell
Ma, Y., Chen, Y., Yu, M., Wang, Y., Lu, S., Guo, J., Luo, G., Zhao, L., Yang, P., Lin, Q., et al. (2024) · Microsystems & Nanoengineering · doi:10.1038/s41378-024-00758-6 · Cited by 79
Lamina-specific cortical dynamics in human visual and sensorimotor cortices
Bonaiuto, J. J., Meyer, S. S., Little, S. J., Rossiter, H. E., Callaghan, M. F., Dick, F., Barnes, G. R., & Bestmann, S. (2018) · eLife · doi:10.7554/elife.33977 · Cited by 74
Self-citationReichert, M., Braun, U., Lautenbach, S., Zipf, A., Ebner‐Priemer, U., Tost, H., & Meyer‐Lindenberg, A. (2019) · Current Opinion in Psychology · doi:10.1016/j.copsyc.2019.08.026 · Cited by 84
Direct-Sense Brain–Computer Interfaces and Wearable Computers
Lin, C., & Do, T. (2020) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmc.2020.3041382 · Cited by 70
“In addition, there has been intensive progress in the development of portable brain scanners – mobile MEG [155].”
BackgroundLarge T1 contrast enhancement using superparamagnetic nanoparticles in ultra-low field MRI
Yin, X., Russek, S. E., Zabow, G., Sun, F., Mohapatra, J., Keenan, K. E., Boss, M. A., Zeng, H., Liu, J. P., Viert, A., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-30264-5 · Cited by 68
Defining Surgical Terminology and Risk for Brain Computer Interface Technologies
Leuthardt, E. C., Moran, D. W., & Mullen, T. R. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.599549 · Cited by 71
“…field detectors which do not require superconducting technology and can be embedded in a wearable form factor is increasing the potential for practical applications in consumer and clinical sectors (Boto et al., 2018); however, it remains to be seen whether or how this will impact BCI applications.”
BackgroundRu, X., He, K., Lyu, B., Li, D., Xu, W., Gu, W., Ma, X., Liu, J., Li, C., Li, T., et al. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119420 · Cited by 59
“Our cylindrical shield significantly reduces the cost and amount of hielding materials compared with a typical MSR while achieving the ame level of shielding performance without an active compensation odule.”
BackgroundMethodInfluentialBiomagnetism: The First Sixty Years
Roth, B. J. (2023) · Sensors · doi:10.3390/s23094218 · Cited by 66
Studying brain activity in sports performance: Contributions and issues
Perrey, S., & Besson, P. (2018) · Progress in brain research · doi:10.1016/bs.pbr.2018.07.004 · Cited by 74
Characterizing hippocampal dynamics with MEG: A systematic review and evidence‐based guidelines
Ruzich, E., Crespo‐García, M., Dalal, S. S., & Schneiderman, J. F. (2018) · Human Brain Mapping · doi:10.1002/hbm.24445 · Cited by 64
Applications of OPM-MEG for translational neuroscience: a perspective
Brickwedde, M., Anders, P., Kühn, A. A., Lofredi, R., Holtkamp, M., Kaindl, A. M., Grent-‘t-Jong, T., Krüger, P., Sander, T. H., & Uhlhaas, P. J. (2024) · Translational Psychiatry · doi:10.1038/s41398-024-03047-y · Cited by 72
Kurashima, K., Kataoka, M., Nakano, T., Fujiwara, K., Kato, S., Nakamura, T., Yuzawa, M., Masuda, M., Ichimura, K., Okatake, S., et al. (2023) · Sensors · doi:10.3390/s23020646 · Cited by 56
“As magnetic sensors are suitable for detecting minute magnetic fields such as heart magnetic fields, optically pumped magnetometers [13,14] and nitrogen-vacancy center magnetometers [15,16] have recently been attracting interest.”
BackgroundMagnetic Field Mapping and Correction for Moving OP-MEG
Mellor, S., Tierney, T. M., O’Neill, G. C., Alexander, N., Seymour, R. A., Holmes, N., López, J. D., Hill, R. M., Boto, E., Rea, M., et al. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3100770 · Cited by 63
Self-citationOptimal design of on‐scalp electromagnetic sensor arrays for brain source localisation
Beltrachini, L., von Ellenrieder, N., Eichardt, R., & Haueisen, J. (2021) · Human Brain Mapping · doi:10.1002/hbm.25586 · Cited by 62
“brain imaging field in 2018 (Boto et al., 2018), they have provided insights into cerebral activity difficultly achieved by the wellestablished SQUID-based magnetoencephalography (MEG) sensors.”
BackgroundNeuroimaging of learning and development: improving ecological validity
van Atteveldt, N., van Kesteren, M. T. R., Braams, B. R., & Krabbendam, L. (2018) · Frontline Learning Research · doi:10.14786/flr.v6i3.366 · Cited by 63
Spherical harmonic based noise rejection and neuronal sampling with multi-axis OPMs
Tierney, T. M., Mellor, S., O’Neill, G. C., Timms, R. C., & Barnes, G. R. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119338 · Cited by 58
“Optimal system design for OPM recordings is less clear as one has the added issues of optimizing for wearability and subject movement (Boto et al., 2018).”
BackgroundSelf-citationZhao, F., Zhou, X., Zhou, W., Zhang, X., Wang, K., & Wang, W. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3188525 · Cited by 55
Hillebrand, A., Holmes, N., Sijsma, N., O’Neill, G. C., Tierney, T. M., Liberton, N., Stam, A. H., van Klink, N. E. C., Stam, C. J., Bowtell, R. W., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-31111-y · Cited by 60
Self-citationMagnetoencephalography and the infant brain
Chen, Y., Saby, J. N., Kuschner, E. S., Gaetz, W. C., Edgar, J. C., & Roberts, T. P. L. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.01.059 · Cited by 61
Measurement of Triaxial Magnetocardiography Using High Sensitivity Tunnel Magnetoresistance Sensor
Wang, M., Wang, Y., Peng, L., & Ye, C. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2927086 · Cited by 55
“The most common scheme of OPM is spin exchange relaxation free (SERF) cell that is capable of measuring magnetic field less than 1 nT [11], [12].”
BackgroundDigital manufacturing of functional materials for wearable electronics
Lin, J., Zhu, Z., Cheung, C. F., Yan, F., & Li, G. (2020) · Journal of Materials Chemistry C · doi:10.1039/d0tc01112f · Cited by 54
Ambulatory assessment for precision psychiatry: Foundations, current developments and future avenues
Reichert, M., Gan, G., Renz, M. P., Braun, U., Brüßler, S., Timm, I., Ma, R., Berhe, O., Benedyk, A., Moldavski, A., et al. (2021) · Experimental Neurology · doi:10.1016/j.expneurol.2021.113807 · Cited by 67
Scalar Magnetometry Below 100 fT/Hz1/2 in a Microfabricated Cell
Gerginov, V. P., Pomponio, M., & Knappe, S. A. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3002193 · Cited by 59
Zhao, F., Zhou, X., Xie, X., & Wang, K. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3106677 · Cited by 54
Optimal Operating Temperature of Miniaturized Optically Pumped Magnetometers
Zhang, S., Lu, J., Ye, M., Zhou, Y., Yin, K., Lu, F., Yan, Y., & Zhai, Y. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3147901 · Cited by 57
Cross-Axis Dynamic Field Compensation of Optically Pumped Magnetometer Arrays for MEG
Robinson, S. E., Benitez-Andonegui, A., Holroyd, T., Hughes, K. J., Alem, O., Knappe, S. A., Maydew, T., Griesshammer, A., & Nugent, A. C. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119559 · Cited by 55
Gutteling, T. P., Bonnefond, M., Clausner, T., Daligault, S., Romain, R., Mitryukovskiy, S. I., Fourcault, W., Josselin, V., Prado, M. L., Palacios-Laloy, A., et al. (2023) · Sensors · doi:10.3390/s23052801 · Cited by 54
“3◦/nT at low frequencies [21] and offsets variations as small as ±3 nT resulted in effective gain errors of ∼5 percent [6,18,46].”
BackgroundReal-time, model-based magnetic field correction for moving, wearable MEG
Mellor, S., Tierney, T. M., Seymour, R. A., Timms, R. C., O’Neill, G. C., Alexander, N., Spedden, M. E., Payne, H., & Barnes, G. R. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120252 · Cited by 55
“Based on (Boto et al., 2018), we estimate that approximately 3% of feedback to a channel will be picked up by a neighbouring OPM.”
Self-citationMagnetic Source Imaging Using a Pulsed Optically Pumped Magnetometer Array
Borna, A., Carter, T. R., DeRego, P., James, C. D., & Schwindt, P. D. D. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2851458 · Cited by 51
Spatial and spectral trajectories in typical neurodevelopment from childhood to middle age
Hunt, B. A. E., Wong, S. M., Vandewouw, M. M., Brookes, M. J., Dunkley, B. T., & Taylor, M. J. (2019) · Network Neuroscience · doi:10.1162/netn_a_00077 · Cited by 59
Self-citationNon-invasive Investigation of Human Hippocampal Rhythms Using Magnetoencephalography: A Review
Pu, Y., Cheyne, D., Cornwell, B. R., & Johnson, B. W. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00273 · Cited by 50
Sources of heading errors in optically pumped magnetometers operated in the Earth's magnetic field
Oelsner, G., Schultze, V., IJsselsteijn, R. P. J., Wittkämper, F., & Stolz, R. (2019) · Physical Review A · doi:10.1103/physreva.99.013420 · Cited by 54
Naturalistic Hyperscanning with Wearable Magnetoencephalography
Holmes, N., Rea, M., Hill, R. M., Boto, E., Leggett, J., Edwards, L. J., Rhodes, N., Shah, V., Osborne, J., Fromhold, T. M., et al. (2023) · Sensors · doi:10.3390/s23125454 · Cited by 52
“This has enabled the recording of brain activity in individual participants undertaking naturalistic tasks (Boto et al., 2018) and exploring virtual reality environments (Roberts et al., 2019), as well as the investigation of cognitive function (Tierney et al., 2018), cerebellar (Lin et al., 2019)…”
BackgroundInfluentialSelf-citationZheng, W., Su, S., Zhang, G., Bi, X., & Lin, Q. (2019) · Biomedical Optics Express · doi:10.1364/boe.380314 · Cited by 49
Zhao, J., Liu, G., Lu, J., Ding, M., Ma, Y., Ji, J., Yang, K., Ma, D., Xing, B., Zhang, N., et al. (2020) · Measurement Science and Technology · doi:10.1088/1361-6501/abc89c · Cited by 49
Pragmatic spatial sampling for wearable MEG arrays
Tierney, T. M., Mellor, S., O’Neill, G. C., Holmes, N., Boto, E., Roberts, G., Hill, R. M., Leggett, J., Bowtell, R. W., Brookes, M. J., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-77589-8 · Cited by 52
Self-citationQuantum magnetic gradiometer with entangled twin light beams
Wu, S., Bao, G., Guo, J., Chen, J., Du, W., Shi, M., Yang, P., Chen, L. Q., & Zhang, W. (2023) · Science Advances · doi:10.1126/sciadv.adg1760 · Cited by 52
Atomic magnetometers and their application in industry
Bai, X., Wen, K., Peng, D., Liu, S., & Luo, L. (2023) · Frontiers in Physics · doi:10.3389/fphy.2023.1212368 · Cited by 57
Climate crisis and ecological emergency: Why they concern (neuro)scientists, and what we can do
Rae, C. L., Farley, M., Jeffery, K. J., & Urai, A. E. (2022) · Brain and Neuroscience Advances · doi:10.1177/23982128221075430 · Cited by 55
“• Liquid helium for MRI and MEG scanners.”
InfluentialSPM 25: open source neuroimaging analysis software
Tierney, T. M., Alexander, N., Ashburner, J., Labra, N., Balbastre, Y., Barnes, G. R., Bezsudnova, Y., Brudfors, M., Eckstein, K., Flandin, G., et al. (2025) · The Journal of Open Source Software · doi:10.21105/joss.08103 · Cited by 79
“A major recent innovation in neuroimaging is MEG using Optically Pumped Magnetometers (OPMs), which enable free movement of the head and body during neural recordings (Boto et al., 2018).”
Self-citationXu, X., Wang, L., Liu, W., & Zhao, Z. (2025) · Measurement · doi:10.1016/j.measurement.2025.117237 · Cited by 47
Optimization of a Diamond Nitrogen Vacancy Centre Magnetometer for Sensing of Biological Signals
Webb, J. L., Troise, L., Hansen, N. W., Achard, J., Brinza, O., Staacke, R., Kieschnick, M., Meijer, J., Perrier, J., Berg‐Sørensen, K., et al. (2020) · Frontiers in Physics · doi:10.3389/fphy.2020.522536 · Cited by 47
“A number of technologies are currently being researched in an effort to replace SQUIDs and overcome these difficulties, including microelectromechanical (MEMs) sensors [2], sensors based on magnetoresistive effects for magnetomyography [3] and in particular atomic (optically pumped) magnetometers for which cryogen-fre…”
BackgroundRepresentation of probabilistic outcomes during risky decision-making
Castegnetti, G., Tzovara, A., Khemka, S., Melinščak, F., Barnes, G. R., Dolan, R. J., & Bach, D. R. (2020) · Nature Communications · doi:10.1038/s41467-020-16202-y · Cited by 48
Self-citationDark matter search with a resonantly-coupled hybrid spin system
Wei, K., Xu, Z., He, Y., Ma, X., Heng, X., Huang, X., Quan, W., Ji, W., Liu, J., Wang, X.-P., et al. (2025) · Reports on Progress in Physics · doi:10.1088/1361-6633/adca52 · Cited by 46
“In the PSD data, we observed that σ B is proportional to f − 1 a for f a ∈ [ 3 , 30 ] Hz, flat for f a ∈ [ 30 , 50 ] Hz, and proportional to f a for f a ∈ [ 50 , 1000 ] Hz.”
Levy, J., Lankinen, K., Hakonen, M., & Feldman, R. (2021) · Social Cognitive and Affective Neuroscience · doi:10.1093/scan/nsaa061 · Cited by 46
Co-registration Comparison of On-Scalp Magnetoencephalography and Magnetic Resonance Imaging
Cao, F., An, N., Xu, W., Wang, W., Yang, Y., Xiang, M., Gao, Y., & Ning, X. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.706785 · Cited by 50
Separating neuroethics from neurohype
Wexler, A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0230-z · Cited by 57
Sweet anticipation and positive emotions in music, groove, and dance
Elst, O. F. V., Vuust, P., & Kringelbach, M. L. (2021) · Current Opinion in Behavioral Sciences · doi:10.1016/j.cobeha.2021.02.016 · Cited by 58
A single-beam dual-axis atomic spin comagnetometer for rotation sensing
Jiang, L., Liu, J., Liang, Y., Tian, M., & Quan, W. (2022) · Applied Physics Letters · doi:10.1063/5.0079429 · Cited by 45
Endurance Exercise Enhances Emotional Valence and Emotion Regulation
Giles, G. E., Eddy, M. D., Brunyé, T. T., Urry, H. L., Graber, H. L., Barbour, R. L., Mahoney, C. R., Taylor, H. A., & Kanarek, R. B. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00398 · Cited by 50
Magnetic and Radar Sensing for Multimodal Remote Health Monitoring
Li, H., Shrestha, A., Heidari, H., Kernec, J. L., & Fioranelli, F. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2872894 · Cited by 49
“and cerebral activity [16].”
Shultz, S. J., Schmitz, R. J., Cameron, K. L., Ford, K. R., Grooms, D. R., Lepley, L. K., Myer, G. D., & Pietrosimone, B. (2019) · Journal of Athletic Training · doi:10.4085/1062-6050-54.084 · Cited by 44
“Further breakthroughs with functional magnetoencephalography may provide the spatial accuracy of fMRI along with the temporal dynamics of EEG without the head-motion restrictions of either.(85) These emerging technologies provide avenues for mobile in vivo brain imaging to increase the ecologic validity of neurophysio…”
BackgroundNugent, A. C., Benitez Andonegui, A., Holroyd, T., & Robinson, S. E. (2022) · Neuroimage: Reports · doi:10.1016/j.ynirp.2022.100093 · Cited by 41
Miniature Biplanar Coils for Alkali-Metal-Vapor Magnetometry
Tayler, M. C. D., Mouloudakis, K., Zetter, R., Hunter, D., Lucivero, V. G., Bodenstedt, S., Parkkonen, L. T., & Mitchell, M. W. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.18.014036 · Cited by 50
Magnetic-field-dependent stimulated emission from nitrogen-vacancy centers in diamond
Hahl, F. A., Lindner, L., Vidal, X., Luo, T., Ohshima, T., Onoda, S., Ishii, S., Zaitsev, A. M., Capelli, M., Gibson, B. C., et al. (2022) · Science Advances · doi:10.1126/sciadv.abn7192 · Cited by 50
Compact multi-channel optically pumped magnetometer for bio-magnetic field imaging
Yuan, Z., Liu, Y., Xiang, M., Gao, Y., Suo, Y., Ye, M., & Zhai, Y. (2023) · Optics & Laser Technology · doi:10.1016/j.optlastec.2023.109534 · Cited by 45
Chen, Y., Liu, X., Dou, S., Fang, Y., Song, P., Wen, T., & Han, B. (2024) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2024.3353928 · Cited by 44
“…Technische Bundesanstalt (PTB) built the magnetically shielded rooms (MSR) for measuring the electric dipole moment [6], the university of Nottingham used the MSR and the active magnetic compensation technique for obtaining the near-zero magnetic environment for the MEG measurement [7], [8].”
MethodPratt, E. J., Ledbetter, M. P., Jiménez-Martínez, R., Shapiro, B., Solon, A. J., Iwata, G. Z., Garber, S., Gormley, J., Decker, D., Delgadillo, D., et al. (2021) · Optical and Quantum Sensing and Precision Metrology · doi:10.1117/12.2581794 · Cited by 44
Machine learning assisted vector atomic magnetometry
Meng, X., Zhang, Y., Zhang, X., Jin, S., Wang, T., Jiang, L., Xiao, L., Jia, S., & Xiao, Y. (2023) · Nature Communications · doi:10.1038/s41467-023-41676-x · Cited by 58
“fundamental research and real-life applications ranging from new physics search [6] to navigation and medical diagnosis [7, 8].”
Metadata
- Authors
- Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., Barnes, G. R., Bowtell, R., & Brookes, M. J.
- Affiliations
- University of Nottingham (GB)
- QuSpin (United States) (US)
- Wellcome Centre for Human Neuroimaging (GB)
- Corresponding author
- Brookes, Matthew J.
- ORCID
- Venue
- Nature
- Published
- 2018-03
- Volume
- 555
- Issue
- 7698
- Pages
- 657-661
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- PMC
- PMC6063354
- OpenAlex
- W2791548393
- Cited by
- 1,377
- References
- 51
- Citations by year
- 2026: 174 · 2025: 236 · 2024: 196 · 2023: 175 · 2022: 175 · 2021: 161 · 2020: 111 · 2019: 107 · 2018: 40
- FWCI
- 48.05
- Type
- journal article
- Language
- en
- Open access
- Licence
- other-oa
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Nottingham ePrints (University of Nottingham) (acceptedVersion)
- University of Birmingham Research Portal (University of Birmingham) (acceptedVersion, other-oa)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Repository@Nottingham (University of Nottingham) (acceptedVersion, other-oa)
- Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Funders
- Wellcome Trust (203147/Z/16/Z, 203257/Z/16/Z, 203257BARNES, 203257/B/16/Z)
- National Institutes of Health (203257/Z/16/Z, 203257/B/16/Z)
- Medical Research Council (MR/K005464/1, MR/M006301/1, 203147/Z/16/Z)
- Engineering and Physical Sciences Research Council (MR/K005464/1, 1652749, 203147/Z/16/Z, 203257/B/16/Z, EP/M013294/1, EP/M013294, 203257/Z/16/Z)
- National Institute of Mental Health (R44MH110288)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R44HD074495)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- quantum sensors, movement disorders, brain function imaging
- MeSH terms
- Wearable Electronic Devices, Adult, Drinking, Female, Head, Humans, Movement, Sports, Magnetoencephalography, Magnetic Fields
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.