The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Moving magnetoencephalography towards real-world applications with a wearable system
Open accessAbstract
Imaging human brain function with techniques such as magnetoencephalography typically requires a subject to perform tasks while their head remains still within a restrictive scanner. This artificial environment makes the technique inaccessible to many people, and limits the experimental questions that can be addressed. For example, it has been difficult to apply neuroimaging to investigation of the neural substrates of cognitive development in babies and children, or to study processes in adults that require unconstrained head movement (such as spatial navigation). Here we describe a magnetoencephalography system that can be worn like a helmet, allowing free and natural movement during scanning. This is possible owing to the integration of quantum sensors, which do not rely on superconducting technology, with a system for nulling background magnetic fields. We demonstrate human electrophysiological measurement at millisecond resolution while subjects make natural movements, including head nodding, stretching, drinking and playing a ball game. Our results compare well to those of the current state-of-the-art, even when subjects make large head movements. The system opens up new possibilities for scanning any subject or patient group, with myriad applications such as characterization of the neurodevelopmental connectome, imaging subjects moving naturally in a virtual environment and investigating the pathophysiology of movement disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Although, there have been some studies on recording the MEG signal of moving participants in a MSR (44) and the unshielded static MEG measurements (35, 37), a MEG system that is both unshielded and movable remains to be developed.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [44]
The cited source says what the claim attributes to it.
In the citing paper
“OPMs are sensitive magnetic field sensors that do not require cryogenics.”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“These devices have enabled the design of flexible MEG sensor arrays, which can be placed closer to the scalp, and adapted to the requirements of individual studies and participants.”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“Using such shielding systems to attenuate the field at the OPM array has been shown to allow naturalistic motion during MEG studies of an individual subject [24,34]”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“Recently, ‘wearable’ MEG has been developed through the use of optically pumped magnetometers (OPMs) [24]”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Event-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Über das Elektrenkephalogramm des Menschen
Berger, H. (1929) · Archiv für Psychiatrie und Nervenkrankheiten · doi:10.1007/bf01797193 · Cited by 4,235
Frequency Dependence of Signal Power and Spatial Reach of the Local Field Potential
Leski, S., Lindén, H., Tetzlaff, T., Pettersen, K. H., & Einevoll, G. T. (2013) · PubMed · doi:10.18154/rwth-conv-084442 · Cited by 3,639
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561 · cited 1×
“In the static case, motion was less than ±1 cm whereas in the moving case it exceeded ±10 cm. Panel (ii) shows an image23,24 of beta modulation (pink overlay) whilst panel (iii) shows a time-frequency spectrogram (TFS) of oscillatory change.”
Abnormal neural oscillations and synchrony in schizophrenia
Uhlhaas, P. J., & Singer, W. (2010) · Nature Reviews Neuroscience · doi:10.1038/nrn2774 · Cited by 2,120 · cited 1×
“Although simple, this task has been applied widely, with beta modulation being used as a marker of brain plasticity18,19, psychosis20,21 and white matter degradation22.”
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
The Resolving Power of Gross Earth Data
Backus, G., & Gilbert, F. (1968) · Geophysical Journal International · doi:10.1111/j.1365-246x.1968.tb00216.x · Cited by 1,523
Large-scale cortical correlation structure of spontaneous oscillatory activity
Hipp, J. F., Hawellek, D. J., Corbetta, M., Siegel, M., & Engel, A. K. (2012) · Nature Neuroscience · doi:10.1038/nn.3101 · Cited by 1,113 · cited 1×
“For example, it is well known that efficient communication between spatially separate cortical regions is key to healthy brain function, and that neural oscillations help mediate such connectivity28,29.”
Research works printed but not linked: 1
- Robinson, S. & Vrba, J. in Recent Advances in Biomagnetism (eds Yoshimoto, T. et al.) 302–305 (Tohoku Univ. Press, 1998)
Cited by
Items 801–900 of 999
Tian, P., Jia, L., Zhang, H., Qiu, S., Zhao, X., Jing, Z., & Zheng, S. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3504580 · Cited by 4
“T HE spin exchange relaxation-free (SERF) optically pumped atomic magnetometer (OPM) has been extensively developed in the realm of precise measurement of extremely weak magnetic fields, owing to its exceptional sensitivity [1], [2], [3].”
Vector fitting-based full-bandwidth crosstalk suppression in triaxial optically pumped magnetometers
Liu, Z., Li, J., Li, X., Sheng, J., Wang, Z., Gao, S., & Lu, J. (2025) · Measurement · doi:10.1016/j.measurement.2025.117286 · Cited by 4
Evaluating the effect of OPM array errors on the multiple dipole localization accuracy of OPM-MEG
Qi, S., Ma, Y., Liu, Z. A., Jia, L., Wu, H., Song, X., & Ning, X. (2025) · Measurement · doi:10.1016/j.measurement.2025.117764 · Cited by 5
The suppression of magnetic noise in a magnetic shielding unit for atomic sensor applications
Karabinaoğlu, M. S., Günay, E., Çakır, B., Caklı, B. M., & Sevim, M. H. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116833 · Cited by 4
Sun, J., Gan, Z., Shi, Y., Zhou, W., Wang, K., & CHENG, J. (2025) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2025.3585053 · Cited by 6
“UMFCs have been extensively employed as magnetic actuators in diverse applications, including magnetic signal imaging [9], [10], precision physics experiments [11], [12], accelerator [13], magnetic shielding device [14], [15] [Fig.”
Guggisberg, A. G., Siebner, H. R., Lundell, H., Madsen, M. A. J., Madsen, K. H., Wiggermann, V., Mégevand, P., Proix, T., Dalal, S. S., Grouiller, F., et al. (2025) · Clinical Neurophysiology · doi:10.1016/j.clinph.2025.2110942 · Cited by 5
Zhao, B., Tang, J., Li, L., Liu, Y., & Zhai, Y. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3304705 · Cited by 7
Mao, Y., Liu, Z., Li, J., Pang, H., Peng, J., & Jie, S. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114663 · Cited by 4
Wang, K., Ma, D., Dou, Y., Gao, Y., Li, S., Wang, J., & Sun, J. (2023) · Results in Physics · doi:10.1016/j.rinp.2023.107017 · Cited by 4
Perspective of quantum technology
Khondakar, K. R. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-98805-6.00010-5 · Cited by 9
Tang, C. L., Gao, T., Wang, G., & Chen, B. (2024) · Cognitive Neurodynamics · doi:10.1007/s11571-024-10085-1 · Cited by 6
“With the remarkable development of magnetic field sensors in recent years, sensors rely on the atomic properties of alkali metals, i.e., optically pumped magnetome-ters (OPMs), have been used to measure MEG (Boto et al. 2018).”
Xie, X., Zhou, X., Zhao, F., Wang, W., Yin, C., & Sun, J. (2024) · Physica Scripta · doi:10.1088/1402-4896/ad7234 · Cited by 4
A planar mounted SQUID full-tensor module for magnetoenterogram denoising detection
Li, H., & Zhang, M. (2024) · Physica C Superconductivity · doi:10.1016/j.physc.2024.1354575 · Cited by 4
Xu, X., Liu, Y., Sun, X. H., & Zhou, W. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3488002 · Cited by 4
“E XTREMELY weak or even near-zero magnetic field conditions are crucial for researching spin-free exchange relaxation (SERF) atomic magnetometers [1], [2], fundamental physics [3], and magnetoencephalograms (MEGs) [4], [5].”
Alt, A. K., Pascher, A., Seizer, L., Finkbeiner, M., Conzelmann, A., & Renner, T. J. (2024) · Internet Interventions · doi:10.1016/j.invent.2024.100785 · Cited by 7
“In addition, advances in mobile neuroimaging – such as functional near-infrared spectroscopy (Sun et al., 2018), wearable EEG caps (Boto et al., 2018), and mobile recording of brain activity (Topalovic et al., 2020) facilitate the study of brain activity under real-life conditions.”
Zhang, N., Peng, Y., & Guo, Q. (2024) · Digital Health · doi:10.1177/20552076241305233 · Cited by 7
Bias Calibration of Optically Pumped Magnetometers Based on Variable Sensitivity
Chen, J., Ye, C., Hou, X., Niu, Y., & Sun, L. (2025) · Sensors · doi:10.3390/s25020433 · Cited by 4
Xu, X., Zhao, Z., & Liu, W. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3547076 · Cited by 4
Tanner, Z., Rier, L., Fildes, J., Rivero, G., Schofield, H., Marani, C., Holmes, N., Hill, R. M., Shah, V., Doyle, C., et al. (2025) · Imaging Neuroscience · doi:10.1162/imag.a.10 · Cited by 10
“…al., 2017; Boto et al., 2017; Iivanainen et al., 2019; C. Johnson et al., 2010; C. N. Johnson et al., 2013; Xia et al., 2006, oscillatory processes: Boto et al., 2018; Hill et al., 2020; Iivanainen et al., 2019; Kamada et al., 2015; Rhodes et al., 2023; Sander et al., 2012, epileptogenic features:…”
Self-citationDry Phantoms With Deep Signal Sources for Magnetoencephalography
Oyama, D., Adachi, Y., & Uehara, G. (2019) · IEEE Magnetics Letters · doi:10.1109/lmag.2019.2944116 · Cited by 4
Yoshimura, Y., Hasegawa, C., Ikeda, T., Saito, D. N., Hiraishi, H., Takahashi, T., Kumazaki, H., & Kikuchi, M. (2020) · Brain and Behavior · doi:10.1002/brb3.1706 · Cited by 5
“Both childcustomized MEG and the innovative new technologies in development for the next decade, such as optically pumped magnetometers for MEG (Boto et al., 2018), will provide more crucial information about both typical and atypical brain development in the real world from the newborn stage…”
BackgroundMentale Beanspruchung in der Montage
Bläsing, D. (2020) · Springer eBooks · doi:10.1007/978-3-662-61374-0_4 · Cited by 5
Advances in laser heating of alkali vapor cells in magnetometers: a review
Wang, K., Zhou, B., Tang, J., Zhang, S., & Wang, Y. (2020) · Applied Optics and Photonics China (AOPC) · doi:10.1117/12.2574588 · Cited by 5
An Overview of Machine Learning Applications in Mood Disorders
Topolski, N., Jeong, S. H., & Mwangi, B. (2021) · Cambridge University Press eBooks · doi:10.1017/9781108623018.017 · Cited by 4
Yalaz, M., Deuschl, G., Noor, M. S., Butz, M., Schnitzler, A., Helmers, A., & Höft, M. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac2c4d · Cited by 4
“no relative movement between head and sensors) and can be adapted to the individual head shape [31, 32].”
High-sensitive magnetometric measuring systems for biomagnetic imaging, recording and diagnostics
Maslennikov, Y. V. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822532-5.00019-4 · Cited by 4
Gradient Field Detection Using Interference of Stimulated Microwave Optical Sidebands
Campbell, K., Wang, Y.-J., Savukov, I., Schwindt, P. D. D., Jau, Y., & Shah, V. (2022) · Physical Review Letters · doi:10.1103/physrevlett.128.163602 · Cited by 4
Self-citationSahoo, S. S., Mishra, S. R., Rajalakshmi, G., & Mohapatra, A. K. (2022) · Physical Review A · doi:10.1103/physreva.105.063509 · Cited by 4
Slow Firing Single Units Are Essential for Optimal Decoding of Silent Speech
Kennedy, P., Ganesh, A., & Cervantes, A. J. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.874199 · Cited by 7
Spatial and Frequency Specific Artifact Reduction in Optically Pumped Magnetometer Recordings
Xiang, J., Tong, H., Jiang, Y., & Barnes‐Davis, M. E. (2022) · Journal of Integrative Neuroscience · doi:10.31083/j.jin2105145 · Cited by 4
“The technical details have been described in previous reports [4, 24].”
BackgroundMethodMapping Brain Networks Using Multimodal Data
Shou, G., Yuan, H., & Ding, L. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_83 · Cited by 4
EEG based BCI for Autonomous Control: A Review
Biswas, S., Hairston, W. D., Metcalfe, J. S., & Bhattacharya, S. (2023) · IEEE SoutheastCon · doi:10.1109/southeastcon51012.2023.10115194 · Cited by 5
Quantum Sensing of Magnetic Fields Using Global Optimization Algorithms
Xiao, W., Ding, Y., Wu, T., Peng, X., & Guo, H. M. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.20.024042 · Cited by 4
Xiao, W., Wang, H., Zhang, X., Wu, Y., Wu, T., Chen, J., Peng, X., & Guo, H. M. (2021) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/eftf/ifcs52194.2021.9604246 · Cited by 4
“Magnetometers have various applications, such as high-precision fundamental measurements [4-6], detection of nuclear magnetic resonance signals [7,8], and biomagnetic field measurements [9,10].”
BackgroundPuttaert, D., Coquelet, N., Wens, V., Peigneux, P., Fery, P., Rovaï, A., Trotta, N., Bier, J. C., Goldman, S., & Tiège, X. D. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.05.18.101683 · Cited by 4
Wearable MEG data recorded during human stepping
Spedden, M. E., O’Neill, G. C., West, T. O., Tierney, T. M., Mellor, S., Alexander, N., Seymour, R. A., Lundbye‐Jensen, J., Nielsen, J. B., Farmer, S. F., et al. (2025) · Data in Brief · doi:10.1016/j.dib.2025.111574 · Cited by 4
Self-citationAn integrated virtual reality platform for naturalistic neuroimaging with magnetoencephalographyPreprint
Zabbah, S., Alexander, N., Mohammadi, Y., Mariola, A., Seymour, R. A., Puvvada, S., Barnes, G. R., & Bach, D. R. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.01.28.701672 · Cited by 5
“Continuous MEG data were analysed using Morlet wavelet decomposition implemented in SPM over a two-minute recording period (one minute eyes open followed by one minute eyes closed), yielding time-resolved estimates of alpha-band power.”
InfluentialSelf-citationFu, X., Yang, Y., Cao, Y., Han, Q., Guo, X. Q. T. Z. W., Xu, Y., & Ning, X. (2025) · Information Fusion · doi:10.1016/j.inffus.2025.103161 · Cited by 3
Optical co-registration method of OPM-MCG and MRI based on skin markers
He, J., Yang, S., Jia, Y., Liang, S., Zhu, Y., Qi, J., Shang, S., Wang, A., Zhao, T., Wei, C., et al. (2025) · Measurement · doi:10.1016/j.measurement.2025.118319 · Cited by 4
Mapping neural signatures of face processing in young children: an OPM-MEG study
Safar, K., Vandewouw, M. M., Rhodes, N., Sato, J., & Taylor, M. J. (2025) · Social Cognitive and Affective Neuroscience · doi:10.1093/scan/nsaf076 · Cited by 8
Wang, Y., Xun, M., Pan, G., Sun, Y., Zhou, X., Zhan, J., Yao, B., Fei, Y., Zhang, R., Li, X., et al. (2025) · IEEE Electron Device Letters · doi:10.1109/led.2025.3593255 · Cited by 3
“W ITH the development of global navigation satellite systems, biomagnetic signal detection and other applications, quantum sensors are evolving towards miniaturization and low power-consumption [1], [2].”
Magnetic Sensing of Ion Transport in a Single Nanopore
Tan, T., Wang, Z., Zhao, C., Duan, W., Bai, H., Zhang, N., & Feng, J. (2025) · Nano Letters · doi:10.1021/acs.nanolett.5c02992 · Cited by 3
Jia, Y., Pei, H., Xu, D., Pang, J., Chen, Y., Shen, C., & Xiang, M. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.108875 · Cited by 3
Quantum sensitivity limits and dynamical correlations in alkali-vapor sensors
Mouloudakis, K., Koutrouli, V., Kominis, I. K., Mitchell, M. W., & Vasilakis, G. (2025) · Physical Review Applied · doi:10.1103/mbdq-md8f · Cited by 4
“Optically pumped magnetometers (OPMs) based on alkali-metal vapors [13–17] are both a well-studied example of continuous quantum measurement and a practical technology that enables applications including detection of biomagnetism [18–21], and laboratory searches for new physics [22–24].”
Jiang, L., Chen, J., Yang, J., Zhao, X., Liu, J., Shi, B., & Zhang, C. (2025) · Measurement · doi:10.1016/j.measurement.2025.120150 · Cited by 3
Xia, H., Wang, S., Ding, Y., Li, G., Tang, J., Ding, B., Liu, Z., Zhao, Z., Zou, L., & Zheng, X. (2026) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2026.186716 · Cited by 4
Nelson, P. M., Sacks, D. D., Korom, M., Remec, N., Perkins, G. A., Cook, K. M., Stoyell, S. M., Evans, M. E., Moser, J., Capparini, C., et al. (2026) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2026.101696 · Cited by 5
“Unlike EEG, OPM-MEG measures magnetic rather than electric fields and is less sensitive to variations in skull conductivity, enhancing spatial precision and source localization accuracy across developmental stages (Boto et al., 2018; Brookes et al., 2022).”
Unraveling quantum dephasing of nitrogen-vacancy center ensembles in diamond
Zhang, J., Cheung, C. K., Kübler, M., Benke, M., Brossaud, M., Wang, Y., Denisenko, A., Peng, R., Anders, J., Corcione, E., et al. (2026) · npj Quantum Materials · doi:10.1038/s41535-026-00869-5 · Cited by 14
Zhang, R., Pang, B., Ding, Y., Li, W., Chen, J., Peng, X., & Guo, H. M. (2019) · Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS) · doi:10.1109/fcs.2019.8856049 · Cited by 3
Barskiy, D. A., Blanchard, J. W., Budker, D., Stern, Q., Eills, J., Elliott, S. J., Picazo‐Frutos, R., Garcon, A., Jannin, S., & Koptyug, I. V. (2023) · Applied Magnetic Resonance · doi:10.1007/s00723-023-01592-1 · Cited by 4
Zhao, R., Wang, R., Gao, Y., & Ning, X. (2024) · Bioengineering · doi:10.3390/bioengineering11050428 · Cited by 4
“With the development of optically pumped magnetometers (OPMs) in recent years, wearable OPM-MEG systems [4,5] have not only overcome the disadvantages of traditional MEG devices [6] that need to operate at low temperatures and sensors that are fixed and far away from the subject’s body but have…”
BackgroundLiu, X., Jiang, Y., Wang, Y., & Pan, L. (2024) · Batteries · doi:10.3390/batteries10060200 · Cited by 3
Enhanced all-optical vector atomic magnetometer enabled by artificial neural network
Qin, J., Xu, J., Jiang, Z., & Qu, J. (2024) · Applied Physics Letters · doi:10.1063/5.0218065 · Cited by 3
QuSpin zero-field magnetometer characterization for the TUCAN experiment
Zhao, M., Mammei, R., & Fujimoto, D. (2024) · Measurement Science and Technology · doi:10.1088/1361-6501/ad89e6 · Cited by 5
“Published calibrations of QZFM sensors have demonstrated response non-linearity under background field strengths up to 3nT pp and observed small crosstalk effects in a helmet-based sensor configuration for magnetoencephagraphy [15].”
InfluentialZhu, J., Jiang, L., Zhao, X. H., Liu, J., Fang, C., Shao, Q., Zou, Y., Xu, J., & Wang, Z. (2024) · Measurement · doi:10.1016/j.measurement.2024.116022 · Cited by 3
Pereira, H., Dores, B. S., Silva, J. P. O., Venâncio, A., Cerqueira, M. F., Rodrigues, J. A., Correia, J. H., Maciel, M. J., & Vieira, E. M. F. (2025) · Vacuum · doi:10.1016/j.vacuum.2025.114103 · Cited by 3
Cao, Z., Zhou, X., Zhao, W.-L., & Shang, J. (2025) · Optics & Laser Technology · doi:10.1016/j.optlastec.2025.112875 · Cited by 3
Bai, H., Jiang, L., Zou, Y., Liu, J., Fang, C., Zhu, J., Shao, Q., Xu, J., & Quan, W. (2025) · Measurement · doi:10.1016/j.measurement.2025.117627 · Cited by 4
Modeling and Analysis of Magnetic Noise in Nanocrystalline Spindle-Shaped Magnetic Shielding System
Xu, X., Zhao, Z., & Wang, L. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3577392 · Cited by 3
“S ERF magnetometers with ultrahigh magnetic field measurement sensitivity are widely used in heart and brain magnetic medicine research [1], [2].”
Sun, J., Gan, Z., Zhou, W., Shi, Y., & Gong, X. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3584163 · Cited by 3
“…great potential in precision measurement and have been widely utilized in physics experiments, such as electric Dipole moments (EDMs), Lorentz symmetry breaking verification, dark matter detection [1], [2], [3], [4], and medical imaging such as magnetoencephalogram (MEG) system [5], [6].”
Yao, H., & Renzoni, F. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3608340 · Cited by 3
Liu, J., Jiang, L., Xu, J., Chen, Y., Li, X., & Wang, Z. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3614826 · Cited by 7
Stereotaxic endoscopy for the ocular imaging of awake, freely moving animal models
Paulson, B., Lee, S., Jue, M., Lee, K., Lee, S., Kim, G. B., Moon, Y., Lee, J. Y., Kim, N., & Kim, J. K. (2020) · Journal of Biophotonics · doi:10.1002/jbio.201960188 · Cited by 3
Mood Disorders: Brain Imaging and Therapeutic Implications
(2021) · Cambridge University Press eBooks · doi:10.1017/9781108623018 · Cited by 3
Electroencephalography and Magnetoencephalography
Corsi, M. (2023) · Neuromethods · doi:10.1007/978-1-0716-3195-9_9 · Cited by 8
From Transparent Cranial Windows to Multifunctional Smart Cranial Platforms
Yang, N., Li, Q., Zhang, X., Xu, J., Xu, S., & Liu, F. (2022) · Electronics · doi:10.3390/electronics11162559 · Cited by 3
Studying Embodied Decisions in the Wild and in the Lab
Gordon, J. R., Lancia, G. L., Eluchans, M., Maselli, A., Thiery, T., Cisek, P., & Pezzulo, G. (2022) · Springer eBooks · doi:10.1007/978-3-031-08629-8_15 · Cited by 3
Small Animal Biomagnetism Applications
Jensen, K., Bentzen, B. H., & Polzik, E. S. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_3 · Cited by 5
“On the other hand, OPMs can now be made compact and mounted in a flexible wearable way, which allows for MEG on children and persons performing some movement [9,21,10].”
BackgroundA High-Sensitivity Cesium Atomic Magnetometer Based on A Cesium Spectral Lamp
Lu, Y., Liu, L., Shi, Y., Zhao, T., Zhu, W., Zhang, T.-F., Liu, W., & Zhang, X. (2023) · Applied Sciences · doi:10.3390/app13148225 · Cited by 3
Cooper, N., Madkhaly, S., Johnson, D. H., Hopton, B., Baldolini, D., & Hackermüller, L. (2023) · Physical Review A · doi:10.1103/physreva.108.013521 · Cited by 3
Gu, W., Li, D., & Gao, J. (2023) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2023.110010 · Cited by 4
A review of giant magneto-impedance-based MEG detection technique
Li, W., Zhou, Z., Tang, J., & Xu, M. (2024) · Brain-Apparatus Communication A Journal of Bacomics · doi:10.1080/27706710.2024.2322930 · Cited by 4
Tailoring Sub‐Doppler Spectra of Thermal Atoms with a Dielectric Optical Metasurface Chip
Zhang, D., & Qing, C. (2024) · Laser & Photonics Review · doi:10.1002/lpor.202301276 · Cited by 3
“[11] In general, according to the developed technology, two types of atoms are applied: the cold atom and the thermal atomic vapor.”
A first step to develop quantum medicine: Radiometers, detectors, and biosensors
Chamkouri, H., Si, J., Chen, P., Niu, C., & Chen, L. (2024) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2024.100658 · Cited by 11
Combined Measurement of Brain Activation During a Motor Task Using fNIRS and OPM-MEG
Marhl, U., Wojtkiewicz, S., Sawosz, P. L., Jazbinšek, V., Jagličić, Z., Liebert, A., & Sander, T. H. (2024) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-61625-9_19 · Cited by 3
Crivelli, D., & Balconi, M. (2024) · Social Neuroscience · doi:10.1080/17470919.2024.2380725 · Cited by 5
“Along such line, a further alternative has recently emerged as a valuable and highly interesting technique for hyperscanning research: wearable MEG based on optically pumped magnetometers (OPM-MEG; Boto et al., 2018; N. Holmes et al., 2023).”
A Novel Efficient Algorithm for Magnetic Biplanar Coils
He, X., Wu, L., Zheng, F., Xu, Z., Li, K., & Lin, Q. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3438990 · Cited by 3
“More importantly, compared with SQUID, MEG measurements can be conducted on subjects, while they are in motion [9].”
BackgroundSignal-enhanced high-sensitivity atomic magnetometer based on multi-pass cell
Peng, J., Yin, Y., Xu, A., Liu, B., Li, Z., & Wang, C. (2024) · Applied Physics Express · doi:10.35848/1882-0786/ad9078 · Cited by 3
Extended homogeneous field correction method based on oblique projection in OPM-MEG
Wang, F., Cao, F., Yu-jie, M., Zhao, R., Wang, R., An, N., Xiang, M., Wang, D., & Ning, X. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2024.120991 · Cited by 4
“Even with the development of active compensation methods (Holmes et al., 2018; Tian et al., 2024; Yang et al., 2021), background field gradients, and complex environmental interferences still pose challenges for background noise suppression (Seymour et al., 2022).”
Performance Portrait Method: Robust Design of Predictive Integral Controller
Huba, M., Bisták, P., Škrinárová, J., & Vrančić, D. (2025) · Biomimetics · doi:10.3390/biomimetics10020074 · Cited by 4
“On a similar principle, magnetoencephalography (MEG) focused on measuring low-intensity magnetic fields arising as a result of brain or heart activity has been developed in recent decades [10–12].”
Adachi, Y., Oyama, D., & Uehara, G. (2025) · IEEE Magnetics Letters · doi:10.1109/lmag.2025.3560886 · Cited by 3
Biplanar Nulling Coil System for OPM-MEG Using Printed Circuit Boards
Jas, M., Kamataris, J., Matsubara, T., Dong, C., Motta, G., Sohrabpour, A., Ahlfors, S. P., Hämäläinen, M., Okada, Y. C., & Sundaram, P. (2025) · Sensors · doi:10.3390/s25092759 · Cited by 6
Measurement of noise of current source by pump-probe atomic magnetometer
Chen, D.-Y., Miao, P.-X., Shi, Y.-C., Jing-zhong, C., Liu, Z., Chen, J., & Wang, K. (2022) · Acta Physica Sinica · doi:10.7498/aps.71.20211122 · Cited by 4
Schneiderman, J. F., Ruffieux, S., Pfeiffer, C., & Riaz, B. (2019) · Springer eBooks · doi:10.1007/978-3-319-62657-4_78-1 · Cited by 3
Progresses and prospects of brain electromagnetic imaging
Zhuo, Y., Yao, D., & Zhang, Y. (2019) · Scientia Sinica Vitae · doi:10.1360/ssv-2019-0097 · Cited by 3
Tri-axial Helium-4 Optically Pumped Magnetometers for MEG
Palacios-Laloy, A., Prado, M. L., & Labyt, É. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_6 · Cited by 3
Reply to “Separating neuroethics from neurohype”
Ienca, M., Haselager, P., & Emanuel, E. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0226-8 · Cited by 3
Hillebrand, A., Holmes, N., Sijsma, N., O’Neill, G. C., Tierney, T. M., Liberton, N. P. T. J., Stam, A. H., van Klink, N. E. C., Stam, C. J., Bowtell, R. W., et al. (2022) · medRxiv · doi:10.1101/2022.11.03.22281836 · Cited by 3
Self-citationAdaptive multipole models of OPM dataPreprint
Tierney, T. M., Seedat, Z. A., Pier, K. S., Mellor, S., & Barnes, G. R. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.09.11.557150 · Cited by 3
“We chose to use a generic helmet here, as opposed to the subject specific scanner casts we usually use (Boto et al., 2018; Meyer et al., 2017; Seymour et al., 2021; Tierney et al., 2018, 2018; Tierney et al., 2021).”
MethodSelf-citationNeural and behavioural rhythmic tracking during language acquisition: The story so farPreprint
Mandke, K. N., & Rocha, S. (2023) · doi:10.31234/osf.io/6d3cq · Cited by 3
The neurodevelopmental trajectory of beta band oscillations: an OPM-MEG studyPreprint
Rier, L., Rhodes, N., Pakenham, D., Boto, E., Holmes, N., Hill, R. M., Rivero, G. R., Shah, V., Doyle, C., Osborne, J., et al. (2024) · eLife · doi:10.7554/elife.94561.1 · Cited by 8
Self-citationDyadic Interaction Platform: A novel tool to study transparent social interactionsPreprint
Isbaner, S., Báez-Mendoza, R., Bothe, R., Eiteljoerge, S. F. V., Fischer, A., Gail, A., Gläscher, J. P., Lüschen, H., Moeller, S., Penke, L., et al. (2025) · eLife · doi:10.7554/elife.106757.1 · Cited by 5
Goodson, T. G., III (2025) · Science · doi:10.1126/science.adj0029 · Cited by 3
Clinical utility of magnetoencephalography and its recent development
Matsubara, T., Tanaka, N., Peled, N., Sohrabpour, A., Sundaram, P., Okada, Y. C., Hämäläinen, M., Pearl, P. L., & Stufflebeam, S. M. (2024) · Epilepsy & Seizure · doi:10.3805/eands.16.71 · Cited by 3
An Excitation Optimization Method for Demagnetization Systems Combined With Magnetic Shaking in MSR
Zhang, D., Shi, M., Yang, J., & Zheng, S. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3547103 · Cited by 2
Xu, X., Ye, F., Zhou, W., Wang, H., Liu, W., & Zhao, Z. (2025) · Measurement · doi:10.1016/j.measurement.2025.117228 · Cited by 2
Activation and characterization of Rb MEMS cells with an automatic system at wafer level
Gozzelino, M., Cerrato, E., Gionco, C., Micalizio, S., Aprile, G., Crivellari, M., Levi, F., & Calonico, D. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116621 · Cited by 2
Sun, H., Song, X., Jia, L., Zhang, J., & Liu, G. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3571111 · Cited by 2
SERF magnetometer array using concurrent amplitude-stabilized optical modulation
Yue, Z., Zhai, Y., Wang, Y., Xu, X., & Tang, J. (2025) · Alexandria Engineering Journal · doi:10.1016/j.aej.2025.05.057 · Cited by 2
Bandwidth Extension Enabled by Modulated VCSEL Pumping for Quantum Sensing Application
Zhou, P., Quan, W., Xu, F., Liang, Z., Hu, J., Liu, L., Hu, G., Xu, Y., & Ye, M. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3568078 · Cited by 3
Metadata
- Authors
- Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., Barnes, G. R., Bowtell, R., & Brookes, M. J.
- Affiliations
- University of Nottingham (GB)
- QuSpin (United States) (US)
- Wellcome Centre for Human Neuroimaging (GB)
- Corresponding author
- Brookes, Matthew J.
- ORCID
- Venue
- Nature
- Published
- 2018-03
- Volume
- 555
- Issue
- 7698
- Pages
- 657-661
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- PMC
- PMC6063354
- OpenAlex
- W2791548393
- Cited by
- 1,377
- References
- 51
- Citations by year
- 2026: 174 · 2025: 236 · 2024: 196 · 2023: 175 · 2022: 175 · 2021: 161 · 2020: 111 · 2019: 107 · 2018: 40
- FWCI
- 48.05
- Type
- journal article
- Language
- en
- Open access
- Licence
- other-oa
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Nottingham ePrints (University of Nottingham) (acceptedVersion)
- University of Birmingham Research Portal (University of Birmingham) (acceptedVersion, other-oa)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Repository@Nottingham (University of Nottingham) (acceptedVersion, other-oa)
- Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Funders
- Wellcome Trust (203147/Z/16/Z, 203257/Z/16/Z, 203257BARNES, 203257/B/16/Z)
- National Institutes of Health (203257/Z/16/Z, 203257/B/16/Z)
- Medical Research Council (MR/K005464/1, MR/M006301/1, 203147/Z/16/Z)
- Engineering and Physical Sciences Research Council (MR/K005464/1, 1652749, 203147/Z/16/Z, 203257/B/16/Z, EP/M013294/1, EP/M013294, 203257/Z/16/Z)
- National Institute of Mental Health (R44MH110288)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R44HD074495)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- quantum sensors, movement disorders, brain function imaging
- MeSH terms
- Wearable Electronic Devices, Adult, Drinking, Female, Head, Humans, Movement, Sports, Magnetoencephalography, Magnetic Fields
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.