Moving magnetoencephalography towards real-world applications with a wearable system
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
Imaging human brain function with techniques such as magnetoencephalography typically requires a subject to perform tasks while their head remains still within a restrictive scanner. This artificial environment makes the technique inaccessible to many people, and limits the experimental questions that can be addressed. For example, it has been difficult to apply neuroimaging to investigation of the neural substrates of cognitive development in babies and children, or to study processes in adults that require unconstrained head movement (such as spatial navigation). Here we describe a magnetoencephalography system that can be worn like a helmet, allowing free and natural movement during scanning. This is possible owing to the integration of quantum sensors, which do not rely on superconducting technology, with a system for nulling background magnetic fields. We demonstrate human electrophysiological measurement at millisecond resolution while subjects make natural movements, including head nodding, stretching, drinking and playing a ball game. Our results compare well to those of the current state-of-the-art, even when subjects make large head movements. The system opens up new possibilities for scanning any subject or patient group, with myriad applications such as characterization of the neurodevelopmental connectome, imaging subjects moving naturally in a virtual environment and investigating the pathophysiology of movement disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Although, there have been some studies on recording the MEG signal of moving participants in a MSR (44) and the unshielded static MEG measurements (35, 37), a MEG system that is both unshielded and movable remains to be developed.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [44]
The cited source says what the claim attributes to it.
In the citing paper
“OPMs are sensitive magnetic field sensors that do not require cryogenics.”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“These devices have enabled the design of flexible MEG sensor arrays, which can be placed closer to the scalp, and adapted to the requirements of individual studies and participants.”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“Using such shielding systems to attenuate the field at the OPM array has been shown to allow naturalistic motion during MEG studies of an individual subject [24,34]”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“Recently, ‘wearable’ MEG has been developed through the use of optically pumped magnetometers (OPMs) [24]”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Event-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Über das Elektrenkephalogramm des Menschen
Berger, H. (1929) · Archiv für Psychiatrie und Nervenkrankheiten · doi:10.1007/bf01797193 · Cited by 4,235
Frequency Dependence of Signal Power and Spatial Reach of the Local Field Potential
Leski, S., Lindén, H., Tetzlaff, T., Pettersen, K. H., & Einevoll, G. T. (2013) · PubMed · doi:10.18154/rwth-conv-084442 · Cited by 3,639
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561 · cited 1×
“In the static case, motion was less than ±1 cm whereas in the moving case it exceeded ±10 cm. Panel (ii) shows an image23,24 of beta modulation (pink overlay) whilst panel (iii) shows a time-frequency spectrogram (TFS) of oscillatory change.”
Abnormal neural oscillations and synchrony in schizophrenia
Uhlhaas, P. J., & Singer, W. (2010) · Nature Reviews Neuroscience · doi:10.1038/nrn2774 · Cited by 2,120 · cited 1×
“Although simple, this task has been applied widely, with beta modulation being used as a marker of brain plasticity18,19, psychosis20,21 and white matter degradation22.”
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
The Resolving Power of Gross Earth Data
Backus, G., & Gilbert, F. (1968) · Geophysical Journal International · doi:10.1111/j.1365-246x.1968.tb00216.x · Cited by 1,523
Large-scale cortical correlation structure of spontaneous oscillatory activity
Hipp, J. F., Hawellek, D. J., Corbetta, M., Siegel, M., & Engel, A. K. (2012) · Nature Neuroscience · doi:10.1038/nn.3101 · Cited by 1,113 · cited 1×
“For example, it is well known that efficient communication between spatially separate cortical regions is key to healthy brain function, and that neural oscillations help mediate such connectivity28,29.”
Research works printed but not linked: 1
- Robinson, S. & Vrba, J. in Recent Advances in Biomagnetism (eds Yoshimoto, T. et al.) 302–305 (Tohoku Univ. Press, 1998)
Cited by
Items 601–700 of 999
Free-induction-decay magnetometer based on synchronous optical pumping and RF pulse modulation
Xu, J., Jiang, L., Liu, J., Liu, J., Chen, Y., Zhu, J., Fang, C., Shao, Q., Zou, Y., & Bai, H. (2025) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-025-00373-y · Cited by 12
“As a typical representative of quantum sensors, optically pumped magnetometers (OPMs) have implemented a wide range of applications in magnetic field sensing such as magne-tocardiography (MCG) [1, 2] and magnetoencephalography (MEG) [3, 4], thanks to their high sensitivity and sensor miniaturization.”
Magnetic and optical control in thermal atomic spin ensembles: Principles and applications
Fan, S., Pei, H., Quan, W., Jia, Y., Liu, J., & Fan, W. (2025) · Science China Physics Mechanics and Astronomy · doi:10.1007/s11433-025-2718-0 · Cited by 11
Liang, A., Wu, H., Ma, Y., Liang, X., Jia, Y., Gao, Y., Ning, X., & Fang, J. (2021) · IEEE Access · doi:10.1109/access.2021.3063054 · Cited by 12
Yalaz, M., Maling, N., Deuschl, G., Paz, L. M. J., Butz, M., Schnitzler, A., Helmers, A., & Höft, M. (2022) · Brain Sciences · doi:10.3390/brainsci12010086 · Cited by 10
“Although the accuracies achieved in our study cannot compete with currently existing methods, the method we used is radiation-free and has the potential to be significantly improved with flexible headcasts for current SQUID-MEG devices [33] or with emerging MEG measurement systems, e.g., with OPM-MEG systems using opt…”
MethodClarke, M. D., Larson, E., Peterson, E. R., McCloy, D., Bosseler, A. N., & Taulu, S. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2022.827529 · Cited by 10
Schneiderman, J. F., Ruffieux, S., Pfeiffer, C., & Riaz, B. (2019) · Springer eBooks · doi:10.1007/978-3-030-00087-5_78 · Cited by 12
Ma, Y., Chen, Y., Zhao, L., Yu, M., Wang, Y., Guo, J., Yang, P., Lin, Q., & Jiang, Z. (2022) · Measurement Science and Technology · doi:10.1088/1361-6501/ac72f9 · Cited by 11
dc Quantum Magnetometry below the Ramsey Limit
Wood, A. A., Stacey, A. D., & Martin, A. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.18.054019 · Cited by 10
Dual-beam room-temperature atomic magnetometer with high sensitivity and large dynamic range
Liu, B., Peng, J., Wang, H., Fang, C., Wang, J., Zhao, X., & Deng, L. (2022) · Applied Physics Express · doi:10.35848/1882-0786/acaa1c · Cited by 10
Characterization of 87Rb MEMS vapor cells for miniature atomic magnetometers
Jiang, M., Zhai, H., Jiang, C., Wang, J., Chen, C., Zhang, Q., Wu, D., Zhang, B., Zeng, Z., Lin, J., et al. (2023) · Applied Physics Letters · doi:10.1063/5.0149388 · Cited by 15
Zhao, R., Wang, R., Gao, Y., & Ning, X. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106236 · Cited by 10
Imagined, Intended, and Spoken Speech Envelope Synthesis from Neuromagnetic Signals
Dash, D., Ferrari, P., Berstis, K., & Wang, J. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-87802-3_13 · Cited by 9
Magnetometers vs Gradiometers for Neural Speech Decoding
Dash, D., Ferrari, P., Abbas Babajani-feremi, A., Borna, A., Schwindt, P. D. D., & Wang, J. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630489 · Cited by 12
“Optically pumped magnetometers (OPMs) offer a new method for MEG measurements [31]–[34].”
MethodMa, D., Fang, X., Lu, J., Wang, K., Sun, B., Gao, Y., Xu, X., & Han, B. (2022) · Materials · doi:10.3390/ma15238704 · Cited by 10
Liu, X., Yang, Y., Ding, M., Quan, W., Hu, Y., Li, Y., Jin, W., & Fang, J. (2019) · Journal of Lightwave Technology · doi:10.1109/jlt.2019.2892479 · Cited by 11
Feys, O., Wens, V., Corvilain, P., Ferez, M., Holmes, N., Brookes, M. J., & Tiège, X. D. (2023) · Epilepsia · doi:10.1111/epi.17806 · Cited by 10
“OPM-MEG can be combined with simultaneous scalp 4,14–16 and intracranial 17 EEG.”
MethodSelf-citationOptically Pumped Magnetometers for Practical MEG-Based Brain-Computer Interfacing
Wittevrongel, B., Holmes, N., Boto, E., Hill, R., Rea, M., Libert, A., Khachatryan, E., Bowtell, R., Brookes, M. J., & Van Hulle, M. M. (2021) · SpringerBriefs in Electrical and Computer Engineering · doi:10.1007/978-3-030-79287-9_4 · Cited by 9
Self-citationAn, N., Gao, Z., Li, W., Cao, F., Wang, W., Xu, W., Wang, C., Xiang, M., Gao, Y., Wang, D., et al. (2024) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2024.108292 · Cited by 10
Tan, G., Gai, J., Li, F., Huang, Q., Yu, W., Huang, Y., Zhang, G., Zhao, X., Lin, Q., & Hu, Z. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3522701 · Cited by 13
Tian, K., Zhang, X., Yang, J., Shi, Z., Hu, Y., Zheng, S., & Liu, G. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3545997 · Cited by 12
Cao, Z., Han, X., Zhou, X., & Shang, J. (2025) · Optics Express · doi:10.1364/oe.550538 · Cited by 9
Liu, W., Xu, X., Zhao, Z., & Wu, W. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116372 · Cited by 9
In-situ magnetic field compensation for zero-field NMOR atomic magnetometer
Zhang, C., Liu, J., Zhao, X. H., Chen, J., Yang, J., Li, J., & Jiang, L. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116385 · Cited by 9
Optically pumped magnetometers based on symmetric frequency-detuning modulated light
Yan, Y., Liu, Z., Wu, Y., Ding, X., Xiang, M., Wang, Y., & Lu, J. (2025) · Optics & Laser Technology · doi:10.1016/j.optlastec.2025.112833 · Cited by 9
Superconducting Quantum Magnetometers for Brain Investigations
Bonavolontà, C., Vettoliere, A., Sorrentino, P., & Granata, C. (2025) · Sensors · doi:10.3390/s25154625 · Cited by 18
Usman, M., Ashebir, S. E., Okey-Mbata, C., Yun, Y., & Kim, S. (2025) · Applied Sciences · doi:10.3390/app152111316 · Cited by 9
MEG current source reconstruction using a meta-analysis fMRI prior
Suzuki, K., & Yamashita, O. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118034 · Cited by 8
Reflected Atomic Magnetometer With Single Beam
Liu, X., Li, Y., Wu, X., Zhang, R., Chang, M., & Zhang, X. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3128944 · Cited by 9
Zero field optically pumped magnetometer with independent dual-mode operation
Zhang, S., Lu, J., Zhou, Y., Lu, F., Yin, K., Zhan, D., Zhai, Y., & Ye, M. (2022) · Chinese Optics Letters · doi:10.3788/col202220.081202 · Cited by 8
The application of mobile functional near-infrared spectroscopy for marketing research – a guideline
Krampe, C. (2022) · European Journal of Marketing · doi:10.1108/ejm-01-2021-0003 · Cited by 13
SERF-OPM Usability for MEG in Two-Layer-Shielded Rooms
Jazbinšek, V., Marhl, U., & Sander, T. H. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_10 · Cited by 9
Niu, Y., & Ye, C. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3299690 · Cited by 9
A Multivariate analysis on evoked components of Chinese semantic congruity: an OP-MEG study with EEG
Wu, H., Liang, X., Wang, R., Ma, Y., Gao, Y., & Ning, X. (2024) · Cerebral Cortex · doi:10.1093/cercor/bhae108 · Cited by 10
Tatsuoka, T., Kawabata, S., Hashimoto, J., Hoshino, Y., Sekihara, K., Shibuya, T., Adachi, Y., & Okawa, A. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115456 · Cited by 9
“In a previous study [20] that measured the magnetic fields originating from the cerebrum using multiple sensors that could operate at room temperature, a whole-head mask tailored to a specific individual was produced using a 3D printer.”
MethodLiu, Z., Lu, J., Hu, Z., Li, X., Yan, Y., Zhan, D., & Li, J. (2024) · Chinese Optics Letters · doi:10.3788/col202422.051201 · Cited by 9
MEG-Based Detection of Voluntary Eye Fixations Used to Control a Computer
Ovchinnikova, A. O., Vasilyev, A. N., Zubarev, I., Kozyrskiy, B. L., & Shishkin, S. L. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.619591 · Cited by 9
“Compared to conventional MEG, OPM-based systems are also more motion-robust (Boto et al., 2018; Hill et al., 2019).”
Zhang, X., Jin, S., Qu, W., & Xiao, Y. (2021) · Applied Physics Letters · doi:10.1063/5.0054842 · Cited by 11
Cao, B., Guo, Y. Q., Guo, Y., Xie, Q., Chen, L., Huang, H., Yu, R., & Huang, R. (2021) · NeuroImage Clinical · doi:10.1016/j.nicl.2021.102797 · Cited by 10
“, 2020) or magnetoencephalography (MEG) (Boto et al., 2018) or transcranial magnetic stimulation (TMS) (Rosanova et al.”
BackgroundA review of fiber‐coupled atomic magnetometer
Liu, X., Bi, W., Li, Y., Hu, Y., Chang, M., & Zhang, X. (2022) · Microwave and Optical Technology Letters · doi:10.1002/mop.33497 · Cited by 10
Enhancement of the Signal-to-Noise Ratio of an Atomic Magnetometer by 10 dB
Bao, G., Wu, S., Liu, S., Huang, W., Li, Z., Chen, L. Q., Yuan, C.-H., & Zhang, W. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.054075 · Cited by 9
Dowsett, J., Dieterich, M., & Taylor, P. C. J. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108540 · Cited by 14
Playing a P300-based BCI VR game leads to changes in cognitive functions of healthy adultsPreprint
Bulat, M., Karpman, A., Samokhina, A., & Panov, A. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.05.28.118281 · Cited by 11
Ecological Brain: Reframing the Study of Human Behaviour and CognitionPreprint
Vigliocco, G., Convertino, L., Felice, S. D., Gregorians, L., Kewenig, V. N., Mueller, M. A. E., Veselič, S., Musolesi, M., Hudson‐Smith, A., Tyler, N., et al. (2023) · doi:10.31234/osf.io/zr4nm · Cited by 9
Fast measurement of magnetic gradient based on four-channel optically pumped atomic magnetometer
Zhang, Y., Tang, J., Li, C., Zhao, B., Li, L., & Zhai, Y. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114591 · Cited by 9
Modeling and experimental studies of degaussing hysteresis in near-zero magnetic shielding systems
Wang, Z., Li, H., Yang, S., Han, B., Yu, S., & Wen, T. (2024) · Journal of Applied Physics · doi:10.1063/5.0193131 · Cited by 8
Shi, M., Zhang, X., Yang, J., Ma, Y., Zhang, L., Tian, K., & Yuan, S. (2024) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ad4b2c · Cited by 8
“Extremely weak magnetic environment with high homogeneity and low temporal drift is a prerequisite for ultra-sensitive and high-precision measurement in various research fields, such as fundamental physical science [1], industrial applications [2, 3], and medical and biomedical science [4].”
Carlé, C., Mursa, A., Karvinen, P., Keshavarzi, S., Hafiz, M. A., Maurice, V. N., Boudot, R., & Passilly, N. (2024) · Journal of Applied Physics · doi:10.1063/5.0213432 · Cited by 8
Wang, F., Cooper, N., He, Y., Hopton, B., Johnson, D., Zhao, P., Tuck, C. J., Hague, R., Fromhold, T. M., Wildman, R. D., et al. (2024) · Quantum Science and Technology · doi:10.1088/2058-9565/ad8678 · Cited by 14
“A critical QT component is the atomic vapour cell [14, 15], it underpins many technologies, spanning laser frequency stabilisation [16, 17], atom, molecule and ion-trapping [18–20] thermal vapour magnetometers [21], medical imaging [1, 2] and industrial scanning applications [22, 23].”
Optical pump magnetometers parametric correction method based on three-axis coil arrays
Liang, S., Zhu, Y., He, J., Qi, J., Jia, Y., Wang, A., Zhao, T., Wei, C., Jiao, H., Feng, L., et al. (2024) · Measurement · doi:10.1016/j.measurement.2024.115909 · Cited by 10
Zhao, X., Tian, P., Zhang, H., Wu, H., Ye, X., Zhang, L., Zhao, F., & Sun, J. (2024) · Measurement · doi:10.1016/j.measurement.2024.116306 · Cited by 8
Cui, P., Yang, Z., Li, Y., Zhang, L., & Liu, X. (2024) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2024.3508065 · Cited by 8
“The research of Elena Boto and his colleagues at the University of Nottingham is the most representative in the MEG measurement [19], [20], [21].”
Xie, X., Zhou, X., Zhao, F., Wang, W., Yin, C., & Sun, J. (2025) · Measurement · doi:10.1016/j.measurement.2025.117052 · Cited by 8
Yan, B., Peng, Y., Zhang, Y., Zhang, Y., Zhang, H., Cao, Y., Sun, C. K., & Ding, M. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2025.121262 · Cited by 8
“…single OPM sensors for brain magnetic signal detection (Boto et al., 2017; Labyt et al., 2018), with experiments demonstrating that individual sensors achieve high signal-to-noise ratio (SNR) and accurate source localization in specific brain regions (Boto et al., 2018, 2019; Tierney et al., 2018).”
MRA-TESO-Based High-Precision Active Magnetic Compensation Method
Jin, Y., Cui, P., Zhang, H., Li, Y., & Yang, Z. (2025) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2025.3592993 · Cited by 8
Additive Manufacturing for Advanced Quantum Technologies
Wang, F., Cooper, N., Johnson, D., Hopton, B., Murray, A., McMullen, R., Fromhold, T. M., Hague, R., Turyanska, L., & Hackermüller, L. (2025) · Advanced Quantum Technologies · doi:10.1002/qute.202500186 · Cited by 10
“For example, the success of recent work on brain pattern imaging with atomic magnetometers has depended in part on a lightweight AM helmet [31, 53] for appropriate positioning of the magnetometers on a mobile subject (see Figure 3(c)).”
Sun, J., Li, Y., Zhang, K., Sun, Y., Wang, Y., Miao, A., Xiang, J., & Wang, X. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.744749 · Cited by 8
“Such a device could improve the spatial resolution of MEG in DBAs and acquire more accurate results than routine MEG devices (67).”
BackgroundToward T2-Limited DC Diamond Quantum Magnetometry via Flux Concentration and Modulation
Xie, Y., Xie, C., Zhu, Y., Jing, K., Tong, Y., Qin, X., Guan, H., Duan, C., Wang, Y., & Rong, X. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3299596 · Cited by 12
“signal measurements [1], [2], geomagnetic surveys [3], mag-”
BackgroundOhkubo, M. (2023) · Review of Scientific Instruments · doi:10.1063/5.0167372 · Cited by 9
Real-Time Localization of OPMs in a Flexible Array During MEG Recordings
Gu, W., He, K., Ma, X., Li, D., Pang, W., Sheng, J., & Gao, J. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3346516 · Cited by 9
Effects of system parameters on a single-beam synthetic gradiometer with a dual-cell structure
Wu, Z., Zhang, J., Chen, W., Ou, Z., Yue, H., Cheng, C., & Liu, Y. (2024) · Optics Letters · doi:10.1364/ol.518697 · Cited by 8
Ma, Y., Gao, Y., Liang, X., Wu, H., Gao, Z., Cao, F., Li, Y., Lu, H., Liu, C., & Ning, X. (2024) · Measurement · doi:10.1016/j.measurement.2024.115149 · Cited by 8
Dead‐Zone‐Free NMOR Atomic Magnetometer Based on Excitation of Dual‐Axis Magnetic Pulse
Jiang, L., Zhang, C., Zhao, X. H., Liu, J., Lu, Z., & Li, J. (2025) · Advanced Quantum Technologies · doi:10.1002/qute.202400475 · Cited by 8
Quantum sensors probe uncharted territories, from Earth’s crust to the human brain
Battersby, S. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1912326116 · Cited by 8
Robust characterization of microfabricated atomic beams on a six-month time scale
Li, C., Wei, B., Chai, X., Yang, J., Daruwalla, A., Ayazi, F., & Raman, C. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.023239 · Cited by 8
Comprehensive influence of modulated and bias magnetic fields on an atomic magnetometer
Yin, Y., Zhou, B., Yin, K., Tang, J., Ning, X., Han, B., & Fang, J. (2021) · Measurement Science and Technology · doi:10.1088/1361-6501/abdb79 · Cited by 11
“Atomic magnetometer arrays show promise for application in the biomedical field, including mag-netocardiography [7, 8] and magnetoencephalography [9, 10].”
Wu, K.-Y., Chen, S. Y., Gong, J., Peng, M., & Yan, H. (2022) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.105.055020 · Cited by 9
Chakraborty, S., Mali, K., & Chatterjee, S. (2021) · Springer eBooks · doi:10.1007/978-3-030-69893-5_16 · Cited by 10
Tang, C., Liu, C., Prado, C. A. G., Zhao, T., Han, B., & Zhai, Y. (2022) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ac6f99 · Cited by 8
Co-Registration Error Analysis and Array Calibration for OPM-MEG System
Pang, M., Huang, Z., Ding, Z., & Han, B. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3216411 · Cited by 9
Healable and Conductive Two-Dimensional Sulfur Iodide for High-Rate Sodium Batteries
Qian, M., Wu, F., Zhang, J., Wang, J., Song, T., & Tan, G. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c05252 · Cited by 8
Hämäläinen, M., & Lundqvist, D. (2019) · Springer eBooks · doi:10.1007/978-3-030-00087-5_81 · Cited by 11
Static weak magnetic field measurements based on low-field nuclear magnetic resonance
Wang, X., Zhu, M., Xiao, K., Guo, J., & Wang, L. (2019) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2019.106580 · Cited by 8
Practice and perspectives of using ultrasensitive magnetometers in biomedical research.
Maslennikov, Y. V. (2021) · Journal of Radio Electronics · doi:10.30898/1684-1719.2021.5.4 · Cited by 7
A 7-channel high- T c SQUID-based on-scalp MEG systemPreprint
Pfeiffer, C., Ruffieux, S., Jönsson, L., Chukharkin, M. L., Kalaboukhov, A., Xie, M., Winkler, D., & Schneiderman, J. F. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/534107 · Cited by 8
All-optical self-oscillating 4He atomic mangnetometer with optical phase shift
Wang, H., Wu, T., Wang, H., Liu, Y., Mao, X., Peng, X., & Guo, H. (2020) · Optics Express · doi:10.1364/oe.390375 · Cited by 7
Sun, Y., Zhou, Y., Wang, X., Bai, D., Wang, Y., & Zhou, Z. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3375422 · Cited by 7
Zheng, F., Li, C., Li, D., Xu, W., Ru, X., Cheng, H., Liu, Z., Na, S., Qin, L., Lyu, B., et al. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3435882 · Cited by 8
“It provides high temporal resolution in milliseconds and spatial resolution within subcentimeters, enabling detailed tracking of brain dynamics [1], [2], [3].”
BackgroundEffect of Optical Nonorthogonality on Dynamic Response in Dual-Beam Atomic Magnetometer
Xing, B., Li, S., Fang, X., Lu, H., & Ma, D. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3502819 · Cited by 7
High-Sensitivity, Microfabricated Quantum Magnetometers With an Intelligent Solar Heating System
Ma, Y., Chen, Y., Yu, M., Yanbin, W., Guo, J., Zhao, M., Yang, P., Lin, Q., & Zhao, L. (2025) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2024.3519377 · Cited by 10
“Among these quantum systems, there exists a common feature that the alkali-metal atomic vapor cell, as the core component, is required to be heated to yield sensitive vapor atoms [7], [8], [9], [10], which inevitably brings the problem of energy consumption.”
Yang, F., Li, X., Du, P., Quan, W., Cui, S., Gou, W., & Li, J. (2025) · Measurement · doi:10.1016/j.measurement.2025.117004 · Cited by 7
Wang, C., Cao, F., Li, W., Wang, W., Li, Y., Xu, W., Yang, J., & An, N. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3550225 · Cited by 7
Zhang, A., Zhang, X., Shi, M., Yang, J., Zhang, L., Tian, K., Shi, Z., Chen, W., & Zheng, S. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3597720 · Cited by 8
Potential of 4 He OPM‐MEG for detecting interictal epileptic activity: A comparison with SQUID‐MEG
Schwartz, D., Badier, J., Gutteling, T. P., Daligault, S., Labyt, É., Bonini, F., & Jung, J. (2025) · Epilepsia Open · doi:10.1002/epi4.70139 · Cited by 12
Chip-scale quantum magnetometer empowered by reflector-integrated all-in-one atomic vapor cell
Ma, Y., Chen, Y., Yu, M., Wang, Y., Guo, J. F., Yang, P., Lin, Q., Lv, Y., Hou, X., & Zhao, L. (2026) · Science China Physics Mechanics and Astronomy · doi:10.1007/s11433-025-2802-7 · Cited by 12
Analysis and Suppression of the Cross-Axis Coupling Effect for Dual-Beam SERF Atomic Magnetometer
Lu, F., Wang, S., Xu, N., Li, B., Lu, J., & Han, B. (2022) · Photonics · doi:10.3390/photonics9110792 · Cited by 8
“However, the background magnetic fields are difficult to maintain at zero due to the magnetic field drift, which will lead to measurement error [12–14], as it also occurs in magnetometers of other principles, such as fluxgate and non-SERF atomic magnetometers [15,16].”
In-situ measurement and cancellation of the light-shift in fiber-coupled atomic magnetometers
Zhao, B., Tang, J., Li, L., Zhang, Y., Li, C., Liu, Y., & Zhai, Y. (2022) · Optics Express · doi:10.1364/oe.476113 · Cited by 7
Troise, L., Hansen, N. W., Olsson, C., Webb, J. L., Tomasevic, L., Achard, J., Brinza, O., Staacke, R., Kieschnick, M., Meijer, J., et al. (2022) · AVS Quantum Science · doi:10.1116/5.0106099 · Cited by 7
Zhang, G., Zeng, H., Guo, R., Zhang, Q., Yu, W., & Lin, Q. (2023) · Optics Letters · doi:10.1364/ol.496076 · Cited by 9
Metasurface-based optical system for miniaturization of atomic magnetometers
Li, J., Zheng, J., Pan, S., Li, K., Yu, H., & Zheng, W. (2024) · Optics Express · doi:10.1364/oe.523114 · Cited by 7
Xing, B., Ma, N., Lv, H., & Lu, J. (2024) · Advanced Quantum Technologies · doi:10.1002/qute.202400226 · Cited by 7
Analysis and suppression of cross-axis modulation coupling errors in optically pumped magnetometers
Long, T., Song, X., Duan, Z., Dai, Y., Suo, Y., Jia, L., & Han, B. (2024) · Measurement · doi:10.1016/j.measurement.2024.115824 · Cited by 8
Repairbads: An automatic and adaptive method to repair bad channels and segments for OPM-MEG
Wang, F., Yu-jie, M., Gao, T., Tao, Y., Wang, R., Zhao, R., Cao, F., Gao, Y., & Ning, X. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2024.120996 · Cited by 8
High-Shielding Coefficient and Low-Noise of Cobalt-Based Metallic Glass Magnetic Shielding Cylinder
Shen, P., Zhang, S., Ma, D., Xing, B., Chen, H., Zhang, M., Wei, H., Li, B., Miao, X., Xie, M., et al. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3545841 · Cited by 7
Liu, W., Xu, X., & Zhao, Z. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3550219 · Cited by 7
Space-Variant Polarization Distribution Mitigates AC-Stark Shifts in a SERF Atomic Magnetometer
Liang, Z., Long, T., Liu, L., Hu, J., Zhou, P., Hu, G., Wang, Y., & Ye, M. (2025) · ACS Photonics · doi:10.1021/acsphotonics.4c02535 · Cited by 7
OPM-MEG reveals dynamics of beta bursts underlying attentional processes in sensory cortex
Rivero, G., Tanner, Z., Rier, L., Hill, R. M., Shah, V., Rea, M., Doyle, C., Osborne, J., Bobela, D., Morris, P. G., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-08037-8 · Cited by 8
“This is typical of the types of signals that have been measured in OPM-MEG demonstrations to date, which most often comprise either evoked responses 32,77 or induced oscillatory modulation 31,37 elicited by simple paradigms.”
Self-citationDunkley, B. T., Jetly, R., Pang, E. W., & Taylor, M. J. (2020) · Journal of Military Veteran and Family Health · doi:10.3138/jmvfh.2019-0029 · Cited by 6
Assessing current mechanisms for the regulation of direct-to-consumer neurotechnology
Dasgupta, I. (2020) · Developments in neuroethics and bioethics · doi:10.1016/bs.dnb.2020.03.009 · Cited by 8
Design and realization of a weak magnetic fast electric heating chip
Guo, Q., Li, Z., Zhao, R., Wen, H., Guo, H., Tang, J., & Liu, J. (2021) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/abfc32 · Cited by 7
Zhu, M., Wang, L., Guo, J., Zhao, X., Sun, X., Ye, C., & Zhou, X. H. (2021) · Optics Express · doi:10.1364/oe.435841 · Cited by 7
Metadata
- Authors
- Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., Barnes, G. R., Bowtell, R., & Brookes, M. J.
- Affiliations
- University of Nottingham (GB)
- QuSpin (United States) (US)
- Wellcome Centre for Human Neuroimaging (GB)
- Corresponding author
- Brookes, Matthew J.
- ORCID
- Venue
- Nature
- Published
- 2018-03
- Volume
- 555
- Issue
- 7698
- Pages
- 657-661
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- PMC
- PMC6063354
- OpenAlex
- W2791548393
- Cited by
- 1,377
- References
- 51
- Citations by year
- 2026: 174 · 2025: 236 · 2024: 196 · 2023: 175 · 2022: 175 · 2021: 161 · 2020: 111 · 2019: 107 · 2018: 40
- FWCI
- 48.05
- Type
- journal article
- Language
- en
- Open access
- Licence
- other-oa
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Nottingham ePrints (University of Nottingham) (acceptedVersion)
- University of Birmingham Research Portal (University of Birmingham) (acceptedVersion, other-oa)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Repository@Nottingham (University of Nottingham) (acceptedVersion, other-oa)
- Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Funders
- Wellcome Trust (203147/Z/16/Z, 203257/Z/16/Z, 203257BARNES, 203257/B/16/Z)
- National Institutes of Health (203257/Z/16/Z, 203257/B/16/Z)
- Medical Research Council (MR/K005464/1, MR/M006301/1, 203147/Z/16/Z)
- Engineering and Physical Sciences Research Council (MR/K005464/1, 1652749, 203147/Z/16/Z, 203257/B/16/Z, EP/M013294/1, EP/M013294, 203257/Z/16/Z)
- National Institute of Mental Health (R44MH110288)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R44HD074495)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- quantum sensors, movement disorders, brain function imaging
- MeSH terms
- Wearable Electronic Devices, Adult, Drinking, Female, Head, Humans, Movement, Sports, Magnetoencephalography, Magnetic Fields
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.