Moving magnetoencephalography towards real-world applications with a wearable system
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
Imaging human brain function with techniques such as magnetoencephalography typically requires a subject to perform tasks while their head remains still within a restrictive scanner. This artificial environment makes the technique inaccessible to many people, and limits the experimental questions that can be addressed. For example, it has been difficult to apply neuroimaging to investigation of the neural substrates of cognitive development in babies and children, or to study processes in adults that require unconstrained head movement (such as spatial navigation). Here we describe a magnetoencephalography system that can be worn like a helmet, allowing free and natural movement during scanning. This is possible owing to the integration of quantum sensors, which do not rely on superconducting technology, with a system for nulling background magnetic fields. We demonstrate human electrophysiological measurement at millisecond resolution while subjects make natural movements, including head nodding, stretching, drinking and playing a ball game. Our results compare well to those of the current state-of-the-art, even when subjects make large head movements. The system opens up new possibilities for scanning any subject or patient group, with myriad applications such as characterization of the neurodevelopmental connectome, imaging subjects moving naturally in a virtual environment and investigating the pathophysiology of movement disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Although, there have been some studies on recording the MEG signal of moving participants in a MSR (44) and the unshielded static MEG measurements (35, 37), a MEG system that is both unshielded and movable remains to be developed.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [44]
The cited source says what the claim attributes to it.
In the citing paper
“OPMs are sensitive magnetic field sensors that do not require cryogenics.”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“These devices have enabled the design of flexible MEG sensor arrays, which can be placed closer to the scalp, and adapted to the requirements of individual studies and participants.”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“Using such shielding systems to attenuate the field at the OPM array has been shown to allow naturalistic motion during MEG studies of an individual subject [24,34]”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“Recently, ‘wearable’ MEG has been developed through the use of optically pumped magnetometers (OPMs) [24]”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Event-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Über das Elektrenkephalogramm des Menschen
Berger, H. (1929) · Archiv für Psychiatrie und Nervenkrankheiten · doi:10.1007/bf01797193 · Cited by 4,235
Frequency Dependence of Signal Power and Spatial Reach of the Local Field Potential
Leski, S., Lindén, H., Tetzlaff, T., Pettersen, K. H., & Einevoll, G. T. (2013) · PubMed · doi:10.18154/rwth-conv-084442 · Cited by 3,639
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561 · cited 1×
“In the static case, motion was less than ±1 cm whereas in the moving case it exceeded ±10 cm. Panel (ii) shows an image23,24 of beta modulation (pink overlay) whilst panel (iii) shows a time-frequency spectrogram (TFS) of oscillatory change.”
Abnormal neural oscillations and synchrony in schizophrenia
Uhlhaas, P. J., & Singer, W. (2010) · Nature Reviews Neuroscience · doi:10.1038/nrn2774 · Cited by 2,120 · cited 1×
“Although simple, this task has been applied widely, with beta modulation being used as a marker of brain plasticity18,19, psychosis20,21 and white matter degradation22.”
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
The Resolving Power of Gross Earth Data
Backus, G., & Gilbert, F. (1968) · Geophysical Journal International · doi:10.1111/j.1365-246x.1968.tb00216.x · Cited by 1,523
Large-scale cortical correlation structure of spontaneous oscillatory activity
Hipp, J. F., Hawellek, D. J., Corbetta, M., Siegel, M., & Engel, A. K. (2012) · Nature Neuroscience · doi:10.1038/nn.3101 · Cited by 1,113 · cited 1×
“For example, it is well known that efficient communication between spatially separate cortical regions is key to healthy brain function, and that neural oscillations help mediate such connectivity28,29.”
Research works printed but not linked: 1
- Robinson, S. & Vrba, J. in Recent Advances in Biomagnetism (eds Yoshimoto, T. et al.) 302–305 (Tohoku Univ. Press, 1998)
Cited by
Items 201–300 of 999
Rier, L., Rhodes, N., Pakenham, D. O., Boto, E., Holmes, N., Hill, R. M., Rivero, G. R., Shah, V., Doyle, C., Osborne, J., et al. (2024) · eLife · doi:10.7554/elife.94561 · Cited by 58
“This enables construction of a wearable MEG system ( Boto et al., 2018 ).”
BackgroundMethodInfluentialSelf-citationZhao, Q., Ye, Z., Deng, Y., Chen, J., Chen, J., Liu, D., Ye, X., & Cheng, H. (2024) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.13327 · Cited by 48
Sekiguchi, N., Fushimi, M., Yoshimura, A., Shinei, C., Miyakawa, M., Taniguchi, T., Teraji, T., Abe, H., Onoda, S., Ohshima, T., et al. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.064010 · Cited by 56
Pang, H., Wang, H., Zhang, K., Fan, W., & Quan, W. (2025) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2025.3629573 · Cited by 45
“The PI controller generated a control signal and fed it into the compensation coil to ensure that the ambient magnetic field of the magnetometer probe is near zero field [19], [20].”
Schofield, H., Hill, R. M., Feys, O., Holmes, N., Osborne, J., Doyle, C., Bobela, D., Corvilain, P., Wens, V., Rier, L., et al. (2024) · Imaging Neuroscience · doi:10.1162/imag_a_00283 · Cited by 62
“Such systems work (e.g., Boto et al., 2018; Corvilain et al., 2024; Feys et al., 2022; Hill et al., 2020; Iivanainen et al., 2019) but their electronic architecture is complex and can be prone to failure.”
BackgroundMethodInfluentialSelf-citationEcological brain: reframing the study of human behaviour and cognition
Vigliocco, G., Convertino, L., Felice, S. D., Gregorians, L., Kewenig, V. N., Mueller, M. A. E., Veselič, S., Musolesi, M., Hudson‐Smith, A., Tyler, N., et al. (2024) · Royal Society Open Science · doi:10.1098/rsos.240762 · Cited by 70
“…magnetic fields produced by the brain’s electrical currents ‘Moving magnetoencephalography towards real-world applications with a wearable system’ [49] global positioning system (GPS) provides (real-time) geolocation and time information ‘Review of GPS travel survey and GPS data-processing…”
Invited Article: Scalable high-sensitivity optomechanical magnetometers on a chip
Li, B., Bulla, D. A. P., Prakash, V., Forstner, S., Dehghan‐Manshadi, A., Rubinsztein-Dunlop, H. H., Foster, S. B., & Bowen, W. P. (2018) · APL Photonics · doi:10.1063/1.5055029 · Cited by 48
Developing Next-Generation Brain Sensing Technologies—A Review
Robinson, J. T., Xie, C., Pohlmeyer, E. A., Gather, M. C., Kemere, C. T., Kitching, J. E., Malliaras, G. G., Marblestone, A. H., Shepard, K. L., & Stieglitz, T. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2931159 · Cited by 50
“6) [125].”
Wide-bandwidth atomic magnetometry via instantaneous-phase retrieval
Wilson, N., Perrella, C., Anderson, R., Luiten, A. N., & Light, P. S. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.013213 · Cited by 42
“[6] Elena Boto, Niall Holmes, James Leggett, Gillian Roberts, Vishal Shah, Sofie S.”
BackgroundEEG and MEG primers for tracking DBS network effects
Litvak, V., Florin, E., Tamás, G., Groppa, S., & Muthuraman, M. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117447 · Cited by 48
Analysis of coil constant of triaxial uniform coils in Mn–Zn ferrite magnetic shields
Ma, D., Lu, J., Fang, X., Wang, K., Wang, J., Zhang, N., Chen, H., Ding, M., & Han, B. (2021) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/abf53c · Cited by 42
Practical real-time MEG-based neural interfacing with optically pumped magnetometers
Wittevrongel, B., Holmes, N., Boto, E., Hill, R., Rea, M., Libert, A., Khachatryan, E., Van Hulle, M. M., Bowtell, R., & Brookes, M. J. (2021) · BMC Biology · doi:10.1186/s12915-021-01073-6 · Cited by 41
Self-citationSuppression of Light Shift for High-Density Alkali-Metal Atomic Magnetometer
Lu, J., Quan, W., Ding, M., Qi, L., & Fang, J. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2877771 · Cited by 42
Alterations in resting-state network dynamics along the Alzheimer’s disease continuum
Puttaert, D., Coquelet, N., Wens, V., Peigneux, P., Fery, P., Rovaï, A., Trotta, N., Sadeghi, N., Coolen, T., Bier, J. C., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-76201-3 · Cited by 53
Exploring the limits of MEG spatial resolution with multipolar expansions
Wens, V. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.119953 · Cited by 46
Schofield, H., Boto, E., Shah, V., Hill, R. M., Osborne, J., Rea, M., Doyle, C., Holmes, N., Bowtell, R. W., Woolger, D., et al. (2022) · Contemporary Physics · doi:10.1080/00107514.2023.2182950 · Cited by 53
“[21]) B) A subject rotated their head to view”
BackgroundMethodInfluentialSelf-citationElectronic skins with a global attraction
Heidari, H. (2018) · Nature Electronics · doi:10.1038/s41928-018-0165-2 · Cited by 40
Applications of brain imaging methods in driving behaviour research
Haghani, M., Bliemer, M. C. J., Farooq, B., Kim, I., Li, Z., Oh, C. H., Shahhoseini, Z., & MacDougall, H. G. (2021) · Accident Analysis & Prevention · doi:10.1016/j.aap.2021.106093 · Cited by 45
Noninvasive vagus nerve stimulation in Parkinson’s disease: current status and future prospects
Sigurdsson, H. P., Raw, R. K., Hunter, H., Baker, M. R., Taylor, J., Rochester, L., & Yarnall, A. J. (2021) · Expert Review of Medical Devices · doi:10.1080/17434440.2021.1969913 · Cited by 45
“employing magnetoencephalography [162] may be used to investigate nVNS underlying mechanisms.”
MethodZhou, W., Han, B., Wang, J., Wu, D., Zhao, F., & Li, N. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3125561 · Cited by 41
Perry, A. R., Bulatowicz, M. D., Larsen, M., Walker, T. G., & Wyllie, R. (2020) · Optics Express · doi:10.1364/oe.408486 · Cited by 39
Application of VCSEL in Bio-Sensing Atomic Magnetometers
Zhou, P., Quan, W., Wei, K., Liang, Z., Hu, J., Liu, L., Hu, G., Wang, A., & Ye, M. (2022) · Biosensors · doi:10.3390/bios12121098 · Cited by 42
Focus on SQUIDs in Biomagnetism
Clarke, J. L., Lee, Y., & Schneiderman, J. F. (2018) · Superconductor Science and Technology · doi:10.1088/1361-6668/aacb14 · Cited by 44
MNSSp3: medical big data privacy protection platform based on internet of things
Wu, X., Zhang, Y., Wang, A., Shi, M., Wang, H., & Liu, L. (2022) · Neural Computing and Applications · doi:10.1007/s00521-020-04873-z · Cited by 38
Iterative Optimization Algorithm to Design Biplanar Coils for Dynamic Magnetoencephalography
Ding, Z., Huang, Z., Pang, M., & Han, B. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3161799 · Cited by 37
“[5] creatively applied the OPM to detect MEG.”
MethodPang, H., Fan, W., Liu, F., Duan, L., Liu, S., Wang, J., & Quan, W. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3201500 · Cited by 40
Application of rapid invisible frequency tagging for brain computer interfaces
Brickwedde, M., Bezsudnova, Y., Kowalczyk, A., Jensen, O. B., & Zhigalov, A. (2022) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2022.109726 · Cited by 38
Quantum sensors will start a revolution — if we deploy them right
Bongs, K., Bennett, S., & Lohmann, A. (2023) · Nature · doi:10.1038/d41586-023-01663-0 · Cited by 38
Mapping the topological organisation of beta oscillations in motor cortex using MEG
Barratt, E. L., Francis, S., Morris, P., & Brookes, M. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.06.041 · Cited by 37
Self-citationEncoding of 3D head direction information in the human brain
kim, M.-S., & Maguire, E. A. (2018) · Hippocampus · doi:10.1002/hipo.23060 · Cited by 44
In-Situ Measurement of Electrical-Heating-Induced Magnetic Field for an Atomic Magnetometer
Lu, J., Wang, J., Yang, K., Zhao, J., Quan, W., Han, B., & Ding, M. (2020) · Sensors · doi:10.3390/s20071826 · Cited by 43
Future Therapeutic Strategies for Freezing of Gait in Parkinson’s Disease
Cui, C. K., & Lewis, S. J. G. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.741918 · Cited by 43
“, 2020) or magnetoencephalography (MEG; Boto et al., 2018), need to be explored for use in FOG and may provide helpful insights into the phenomenon.”
BackgroundA study of scalar optically-pumped magnetometers for use in magnetoencephalography without shielding
Clancy, R. J., Gerginov, V., Alem, O., Becker, S., & Knappe, S. (2021) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ac18fb · Cited by 37
Noisy atomic magnetometry in real time
Amorós-Binefa, J., & Kołodyński, J. (2021) · New Journal of Physics · doi:10.1088/1367-2630/ac3b71 · Cited by 48
Hybrid Method for Reducing the Residual Field in the Magnetic Shielding Room
Li, Y., Zhao, J., Liu, X., Wen, T., Zheng, S., & Cui, P. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3229347 · Cited by 37
“THE magnetic shielding room (MSR) is crucial for achieving a nearly zero magnetic field environment and has broad applications in various fields, such as quantum research, biomedical science, and biomagnetic signal measurement [1], [2], [3], [4].”
BackgroundLibet’s legacy: A primer to the neuroscience of volition
Dominik, T., Mele, A. R., Schurger, A., & Maoz, U. (2023) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2023.105503 · Cited by 53
Metasurface-integrated elliptically polarized laser-pumped SERF magnetometers
Liang, Z., Hu, J., Zhou, P., Liu, L., Hu, G., Wang, A., & Ye, M. (2024) · Microsystems & Nanoengineering · doi:10.1038/s41378-024-00715-3 · Cited by 40
“A multilayer cylindrical magnetic shield composed of three layers of µ-metal and an aluminum shield achieves a quasistatic shielding factor of at least 10 5 , ensuring a low-noise magnetic environment with a residual magnetic fi eld measuring below 5 nT.”
BackgroundWang, J., Song, X., Le, Y., Wu, W., Zhou, B., & Ning, X. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3015562 · Cited by 37
“generation of magnetoencephalography has emerged recently, equipped with an array of optically pumped magnetometers (OPM) to provide non-invasive mapping of human brain electrophysiology activity [13].”
BackgroundOptically pumped magnetometers enable a new level of biomagnetic measurements
Sander, T. H., Jodko-Władzińska, A., Hartwig, S., Brühl, R., & Middelmann, T. (2019) · Advanced Optical Technologies · doi:10.1515/aot-2020-0027 · Cited by 44
MEG Sensor Selection for Neural Speech Decoding
Dash, D., Wisler, A. A., Ferrari, P., Davenport, E. M., Maldjian, J. A., & Wang, J. (2020) · IEEE Access · doi:10.1109/access.2020.3028831 · Cited by 43
“Although the reproduction of these results with OPM sensors is necessary there are reasons to be optimistic as the quality of OPMs is improving and signals, albeit slightly noisier, are believed to be similar to current MEG systems [48].”
BackgroundResultInfluentialGiovannetti, A., Susi, G., Casti, P., Mencattini, A., Pusil, S. A., López, M. E., Natale, C. D., & Martinelli, E. (2021) · Neural Computing and Applications · doi:10.1007/s00521-021-06105-4 · Cited by 36
Single beam Cs-Ne SERF atomic magnetometer with the laser power differential method
Chen, Y., Zhao, L., Zhang, N., Yu, M., Ma, Y., Han, X., Zhao, M., Lin, Q., Yang, P., & Jiang, Z. (2022) · Optics Express · doi:10.1364/oe.450571 · Cited by 42
An, N., Cao, F., Wen, L., Wang, W., Xu, W., Wang, C., Xiang, M., Gao, Y., Sui, B., Liang, A., et al. (2022) · iScience · doi:10.1016/j.isci.2022.103752 · Cited by 40
A 7-Channel High-${T}_\text{c}$ SQUID-Based On-Scalp MEG System
Pfeiffer, C., Ruffieux, S., Jönsson, L., Chukharkin, M. L., Kalaboukhov, A., Xie, M., Winkler, D., & Schneiderman, J. F. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2938688 · Cited by 48
Planar Coil Optimization in a Magnetically Shielded Cylinder
Packer, M., Hobson, P. J., Holmes, N., Leggett, J., Glover, P., Brookes, M. J., Bowtell, R., & Fromhold, T. M. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.15.064006 · Cited by 37
Self-citationMeasuring the cortical tracking of speech with optically-pumped magnetometers
de Lange, P., Boto, E., Holmes, N., Hill, R. M., Bowtell, R. W., Wens, V., Tiège, X. D., Brookes, M. J., & Bourguignon, M. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.117969 · Cited by 37
Self-citationSingle-beam three-axis optically pumped magnetometers with sub-100 femtotesla sensitivity
Xiao, W., Wu, Y., Zhang, X., Feng, Y., Sun, C., Wu, T., Chen, J., Peng, X., & Guo, H. M. (2021) · Applied Physics Express · doi:10.35848/1882-0786/ac00d9 · Cited by 36
Guo, Q., Hu, T., Chen, C.-Q., Feng, X., Wu, Z., Zhang, Y., Zhang, M., Chang, Y., & Yang, X. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3102146 · Cited by 38
Li, S., Ma, D., Lu, J., Xing, B., Wang, K., Gao, Y., & Han, B. (2022) · Measurement · doi:10.1016/j.measurement.2022.111878 · Cited by 37
Wafer-level vapor cells filled with laser-actuated hermetic seals for integrated atomic devices
Maurice, V. N., Carlé, C., Keshavarzi, S., Chutani, R., Queste, S., Gauthier‐Manuel, L., Cote, J.-M., Vicarini, R., Hafiz, M. A., Boudot, R., et al. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00468-x · Cited by 36
Kim, J. A., & Davis, K. D. (2021) · Journal of Neurophysiology · doi:10.1152/jn.00530.2020 · Cited by 44
Soft electronics for advanced infant monitoring
Yuan, M., Long, Y., Liu, T., Liu, J., Qiu, S., Lin, T. Y., Xu, F., & Fang, Y. (2024) · Materials Today · doi:10.1016/j.mattod.2024.03.005 · Cited by 35
Study of Shielding Ratio of Cylindrical Ferrite Enclosure With Gaps and Holes
Ma, D., Ding, M., Lu, J., Yao, H., Zhao, J., Yang, K., Cai, J., & Han, B. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2904719 · Cited by 35
“The high-performance magnetic shielding system are important for ultrasensitive atomic sensors, such as low field magnetic resonance system [1], [2], atomic gyroscopes and magnetometers [3]–[6], atom interferometries [7], and atomic clocks [8], [9].”
BackgroundBeedie, C., Benedetti, F., Barbiani, D., Camerone, E. M., Lindheimer, J. B., & Roelands, B. (2019) · European Journal of Sport Science · doi:10.1080/17461391.2019.1675765 · Cited by 39
“However, imaging technology is developing quickly, and it is likely that over the coming years advances will be made rendering these techniques even more informative, especially in relation to the study of brain during processes of movement (Boto et al., 2018).”
BackgroundHerriott-cavity-assisted all-optical atomic vector magnetometer
Cai, B., Hao, C., Qiu, Z., Yu, Q.-Q., Xiao, W., & Sheng, D. (2020) · Physical Review A · doi:10.1103/physreva.101.053436 · Cited by 35
Magnetic field interference suppression for minimized SERF atomic magnetometer
Jia, L., Song, X., Suo, Y., Li, J., Long, T., & Ning, X. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114188 · Cited by 35
Detection and localization of deep sources in magnetoencephalography: A review
Bénar, C., Velmurugan, J., López‐Madrona, V. J., Pizzo, F., & Badier, J. (2021) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2021.100285 · Cited by 45
Concurrent spinal and brain imaging with optically pumped magnetometers
Mardell, L. C., Spedden, M. E., O’Neill, G. C., Tierney, T. M., Timms, R. C., Zich, C., Barnes, G. R., & Bestmann, S. (2024) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2024.110131 · Cited by 39
Self-citationLong-baseline quantum sensor network as dark matter haloscope
Jiang, M., Hong, T., Hu, D., Chen, Y., Yang, F. W., Hu, T., Yang, X., Shu, J., Zhao, Y., Peng, X., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-47566-0 · Cited by 46
“9997, which is negligible.”
Detection of low-conductivity objects using eddy current measurements with an optical magnetometer
Jensen, K., Zugenmaier, M., Arnbak, J., Stærkind, H., Balabas, M. V., & Polzik, E. S. (2019) · Physical Review Research · doi:10.1103/physrevresearch.1.033087 · Cited by 40
Evolution of MEG : A first MEG ‐feasible fluxgate magnetometer
Koshev, N., Butorina, A. V., Skidchenko, E., Kuzmichev, A. N., Ossadtchi, A. E., Ostras, M., Fedorov, M. V., & Vetoshko, P. M. (2021) · Human Brain Mapping · doi:10.1002/hbm.25582 · Cited by 35
“square of the distance between the current source and the sensor (Boto et al., 2018).”
BackgroundMethodInfluentialTheories and models of negative symptoms in schizophrenia and clinical implications
Chan, R. C. K., Wang, L., & Lui, S. S. Y. (2022) · Nature Reviews Psychology · doi:10.1038/s44159-022-00065-9 · Cited by 44
Wu, K.-Y., Chen, S. Y., Sun, G. A., Peng, S., Peng, M., & Yan, H. (2022) · Physical Review Letters · doi:10.1103/physrevlett.129.051802 · Cited by 36
Optimal buffer gas pressure in dual-beam spin-exchange relaxation-free magnetometers
Lu, J., Zhang, S., Zhou, Y., Yan, Y., Lu, F., Wang, K., Zhai, Y., & Ye, M. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.113928 · Cited by 34
Parameter optimisation of miniaturised SERF magnetometer below relaxation rate saturation region
Li, R., Liu, Y., Li, C., Li, S., Li, J., & Zhai, Y. (2023) · Measurement · doi:10.1016/j.measurement.2023.112733 · Cited by 36
Active Magnetic-Field Stabilization with Atomic Magnetometer
Zhang, R., Ding, Y., Yang, Y., Zheng, Z., Chen, J., Peng, X., Wu, T., & Guo, H. (2020) · Sensors · doi:10.3390/s20154241 · Cited by 32
Ma, Y., Chen, Y., Zhao, L., Luo, G., Yu, M., Wang, Y., Guo, J., Yang, P., Lin, Q., & Jiang, Z. (2022) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2022.169495 · Cited by 35
Ma, Y., Qiao, Z., Yu, M., Wang, Y., Chen, Y., Luo, G., Yang, P., Lin, Q., Zhao, L., Zhang, Y., et al. (2022) · Applied Physics Letters · doi:10.1063/5.0105945 · Cited by 35
A wearable repetitive transcranial magnetic stimulation device
Qi, Z., Liu, H., Jin, F., Wang, Y., Lu, X., Liu, L., Yang, Z., Fan, L., Song, M., Zuo, N., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-58095-9 · Cited by 44
“…conduct rTMS during spontaneous and free behaviors in diversereal-worldsettings, our understanding of neural modulation in dynamic environments is limited 11 – 13 , and walking investigations conducted on laboratory treadmills cannot fully replicate the real-life scenariosexperiencedbysubjects 14 .”
Wardle, S. G., & Baker, C. I. (2020) · F1000Research · doi:10.12688/f1000research.22296.1 · Cited by 34
“The development of a new generation of wearable MEG systems based on arrays of optically pumped magnetometers promises further advancement in the measurement of brain activity at a high temporal resolution in more varied contexts 70,71 .”
BackgroundInterference in Atomic Magnetometry
Jiang, M., Xu, W., Li, Q., Wu, Z., Suter, D., & Peng, X. (2020) · Advanced Quantum Technologies · doi:10.1002/qute.202000078 · Cited by 31
Accurate Polarimetry of Hybrid K-Rb and 21 Ne Atoms Based on Spin-Exchange Interactions
Wei, K., Zhao, T., Fang, X., Xu, Z., Zhai, Y., & Quan, W. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3041832 · Cited by 33
“ATOMIC magnetometers and comagnetometers have been used in many applications [1], including biomagnetism [2], inertial navigation [3], [4] and tests of fundamental physics [5], [6].”
MethodInvestigating real-life emotions in romantic couples: a mobile EEG study
Packheiser, J., Berretz, G., Rook, N., Bahr, C., Schockenhoff, L., Güntürkün, O., & Ocklenburg, S. (2021) · Scientific Reports · doi:10.1038/s41598-020-80590-w · Cited by 37
Magnetoencephalography abnormalities in adult mild traumatic brain injury: A systematic review
Allen, C. M., Halsey, L., Topcu, G., Rier, L., Gascoyne, L. E., Scadding, J. W., Furlong, P. L., Dunkley, B. T., das Nair, R., Brookes, M. J., et al. (2021) · NeuroImage Clinical · doi:10.1016/j.nicl.2021.102697 · Cited by 35
“(13) However, technical innovations have allowed the development of prototype MEG sensory arrays that can operate at room temperature.(14) The advantage of MEG lies in a much higher temporal resolution than functional MRI, with technical developments aimed at matching the former’s spatial resolution.”
BackgroundSelf-citationDetection and analysis of cortical beta bursts in developmental EEG data
Rayson, H., Debnath, R., Alavizadeh, S., Fox, N. A., Ferrari, P. F., & Bonaiuto, J. J. (2022) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2022.101069 · Cited by 39
Recent Progress on Micro-Fabricated Alkali Metal Vapor Cells
Wang, X., Ye, M., Lu, F., Mao, Y., Tian, H., & Li, J. (2022) · Biosensors · doi:10.3390/bios12030165 · Cited by 32
“In 2018, researchers at the University of Nottingham, UK, integrated a novel mobile magnetoencephalography device by utilizing a commercial SERF atomic magnetometer [108], as shown in Figure 22.”
MethodA low-noise multilayer mu-metal thin shell magnetic shield for ultra-highly sensitive atomic sensors
Gao, Y., Ma, D., Wang, K., Xu, X., Li, S., Dou, Y., & Li, J. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114207 · Cited by 34
Long, T., Song, X., Duan, Z., Suo, Y., Wu, Z., Jia, L., & Han, B. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3341139 · Cited by 40
Adaptive multipole models of optically pumped magnetometer data
Tierney, T. M., Seedat, Z. A., Pier, K. S., Mellor, S., & Barnes, G. R. (2024) · Human Brain Mapping · doi:10.1002/hbm.26596 · Cited by 41
“We chose to use a generic helmet here, as opposed to the subject specific scanner casts we usually use (Boto et al., 2018; Meyer et al., 2017; Seymour et al., 2021; Tierney et al., 2018; Tierney, Levy, et al., 2021).”
MethodSelf-citationLiu, Y., Yang, J., Cao, F., Zhang, X., & Zheng, S. (2024) · Materials · doi:10.3390/ma17225469 · Cited by 37
“With its advantages of high sensitivity and miniaturization, SERF atomic magnetometers play a key role in the field of extremely weak biological magnetic field measurement represented by magnetocardiography (MCG) [12,13] and magnetoencephalogram (MEG) [14,15].”
Huffman, D. J., & Ekstrom, A. D. (2020) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_01653 · Cited by 34
“In the future, mobile PET and MEG (Boto et al., 2018) might provide solutions.”
BackgroundEEG, MEG and neuromodulatory approaches to explore cognition: Current status and future directions
Beppi, C., Violante, I. R., Scott, G., & Sandrone, S. (2021) · Brain and Cognition · doi:10.1016/j.bandc.2020.105677 · Cited by 45
Test-retest reliability of the human connectome: An OPM-MEG study
Rier, L., Michelmann, S., Ritz, H., Shah, V., Hill, R. M., Osborne, J., Doyle, C., Holmes, N., Bowtell, R. W., Brookes, M. J., et al. (2023) · Imaging Neuroscience · doi:10.1162/imag_a_00020 · Cited by 36
“…been shown in both theory ( Boto et al., 2016; Iivanainen et al., 2017) and practice ( Boto et al., 2017), including during subject movement (e.g. Boto et al., 2018), though recording during active movement critically depends on background field control ( Holmes et al., 2018, 2020; Rea et al.,…”
BackgroundSelf-citationAsymmetric Cylindrical Coils Design for Uniform Magnetic Field
Han, B., Zhou, W., Xu, X., Sun, J., Zhao, F., Jiang, Q., & Qin, J. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3311064 · Cited by 30
Sun, J., Ren, J., Xu, X., Zhou, W., Qian, J., Wang, H., & Wang, H. (2024) · Measurement · doi:10.1016/j.measurement.2024.114594 · Cited by 31
Restoring Speech Using Brain–Computer Interfaces
Stavisky, S. D. (2025) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110122-012818 · Cited by 51
Ultrastable Optical Magnetometry
Wilson, N., Light, P. S., Luiten, A. N., & Perrella, C. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.044034 · Cited by 33
Sub-Sm–1 electromagnetic induction imaging with an unshielded atomic magnetometer
Deans, C., Marmugi, L., & Renzoni, F. (2020) · Applied Physics Letters · doi:10.1063/5.0002146 · Cited by 37
Probe noise characteristics of the spin-exchange relaxation-free (SERF) magnetometer
Xing, B., Sun, C., Liu, Z., Zhao, J., Lu, J., Han, B., & Ding, M. (2021) · Optics Express · doi:10.1364/oe.416797 · Cited by 30
Tsoi, L., Burns, S. M., Falk, E. B., & Tamir, D. (2022) · Social and Personality Psychology Compass · doi:10.1111/spc3.12707 · Cited by 41
“Newer technologies like wearable magnetoencephalography with optically pumped magnometers (OPM-MEG; Boto et al., 2018) provide an exciting addition to this area of study (Holmes et al., 2021).”
Wei, K., Zhao, T., Fang, X., Zhai, Y., Li, H., & Quan, W. (2019) · Optics Express · doi:10.1364/oe.27.016169 · Cited by 29
Simulation Study of Different OPM-MEG Measurement Components
Marhl, U., Sander, T. H., & Jazbinšek, V. (2022) · Sensors · doi:10.3390/s22093184 · Cited by 31
“Among the most established approaches used to place individual OPM sensors on the head is the method of 3D printing a custom sensor holder, which fits the individual subject’s head surface [8,13].”
MethodMagnetoencephalography can reveal deep brain network activities linked to memory processes
López‐Madrona, V. J., Villalon, S. M., Badier, J., Trébuchon, A., Velmurugan, J., Bartoloméi, F., Carron, R., Barborică, A., Vulliémoz, S., Alario, F. ‐., et al. (2022) · Human Brain Mapping · doi:10.1002/hbm.25987 · Cited by 33
A novel low-noise Mu-metal magnetic shield with winding shape
Ma, D., Lu, J., Fang, X., Dou, Y., Wang, K., Gao, Y., Li, S., & Han, B. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.113884 · Cited by 29
Abnormal neural oscillations during gait and dual-task in Parkinson’s disease
Nwogo, R. O., Kammermeier, S., & Singh, A. (2022) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2022.995375 · Cited by 31
Detection and analysis of MEG signals in occipital region with double-channel OPM sensors
Zhang, X., Chen, C.-Q., Zhang, M., Ma, C., Zhang, Y., Wang, H., Guo, Q., Hu, T., Liu, Z., Chang, Y., et al. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108948 · Cited by 29
Contactless measurements of retinal activity using optically pumped magnetometers
Westner, B. U., Lubell, J. I., Jensen, M., Hokland, S., & Dalal, S. S. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118528 · Cited by 29
“…Borna et al., 2020 ) or new sensor types ( Zhang et al., 2020 ) will make t easier to record neural magnetic fields with OPM technology and will lso make restrictions of the present study (like the requirement to keep till during the recording) obsolete ( Boto et al., 2018; Roberts et al., 019 ).”
BackgroundInfluentialYang, Y., Luo, S., Wang, W., Gao, X., Yao, X., & Wu, T. (2024) · NeuroImage Clinical · doi:10.1016/j.nicl.2024.103608 · Cited by 41
“One study used the OPM with the optical radio-frequency dual-reso-nance phenomenon to detect magnetic signals of the brain in 2017 (Boto et al., 2018).”
Miniature quad-channel spin-exchange relaxation-free magnetometer for magnetoencephalography
Li, J., Du, P., Fu, J., Wang, X.-T., Zhou, Q., & Wang, R. (2019) · Chinese Physics B · doi:10.1088/1674-1056/28/4/040703 · Cited by 27
Pfeiffer, C., Ruffieux, S., Andersen, L. M., Kalabukhov, A., Winkler, D., Oostenveld, R., Lundqvist, D., & Schneiderman, J. F. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116686 · Cited by 28
Metadata
- Authors
- Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., Barnes, G. R., Bowtell, R., & Brookes, M. J.
- Affiliations
- University of Nottingham (GB)
- QuSpin (United States) (US)
- Wellcome Centre for Human Neuroimaging (GB)
- Corresponding author
- Brookes, Matthew J.
- ORCID
- Venue
- Nature
- Published
- 2018-03
- Volume
- 555
- Issue
- 7698
- Pages
- 657-661
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- PMC
- PMC6063354
- OpenAlex
- W2791548393
- Cited by
- 1,377
- References
- 51
- Citations by year
- 2026: 174 · 2025: 236 · 2024: 196 · 2023: 175 · 2022: 175 · 2021: 161 · 2020: 111 · 2019: 107 · 2018: 40
- FWCI
- 48.05
- Type
- journal article
- Language
- en
- Open access
- Licence
- other-oa
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Nottingham ePrints (University of Nottingham) (acceptedVersion)
- University of Birmingham Research Portal (University of Birmingham) (acceptedVersion, other-oa)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Repository@Nottingham (University of Nottingham) (acceptedVersion, other-oa)
- Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Funders
- Wellcome Trust (203147/Z/16/Z, 203257/Z/16/Z, 203257BARNES, 203257/B/16/Z)
- National Institutes of Health (203257/Z/16/Z, 203257/B/16/Z)
- Medical Research Council (MR/K005464/1, MR/M006301/1, 203147/Z/16/Z)
- Engineering and Physical Sciences Research Council (MR/K005464/1, 1652749, 203147/Z/16/Z, 203257/B/16/Z, EP/M013294/1, EP/M013294, 203257/Z/16/Z)
- National Institute of Mental Health (R44MH110288)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R44HD074495)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- quantum sensors, movement disorders, brain function imaging
- MeSH terms
- Wearable Electronic Devices, Adult, Drinking, Female, Head, Humans, Movement, Sports, Magnetoencephalography, Magnetic Fields
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.