Moving magnetoencephalography towards real-world applications with a wearable system
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
Imaging human brain function with techniques such as magnetoencephalography typically requires a subject to perform tasks while their head remains still within a restrictive scanner. This artificial environment makes the technique inaccessible to many people, and limits the experimental questions that can be addressed. For example, it has been difficult to apply neuroimaging to investigation of the neural substrates of cognitive development in babies and children, or to study processes in adults that require unconstrained head movement (such as spatial navigation). Here we describe a magnetoencephalography system that can be worn like a helmet, allowing free and natural movement during scanning. This is possible owing to the integration of quantum sensors, which do not rely on superconducting technology, with a system for nulling background magnetic fields. We demonstrate human electrophysiological measurement at millisecond resolution while subjects make natural movements, including head nodding, stretching, drinking and playing a ball game. Our results compare well to those of the current state-of-the-art, even when subjects make large head movements. The system opens up new possibilities for scanning any subject or patient group, with myriad applications such as characterization of the neurodevelopmental connectome, imaging subjects moving naturally in a virtual environment and investigating the pathophysiology of movement disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Although, there have been some studies on recording the MEG signal of moving participants in a MSR (44) and the unshielded static MEG measurements (35, 37), a MEG system that is both unshielded and movable remains to be developed.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [44]
The cited source says what the claim attributes to it.
In the citing paper
“OPMs are sensitive magnetic field sensors that do not require cryogenics.”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“These devices have enabled the design of flexible MEG sensor arrays, which can be placed closer to the scalp, and adapted to the requirements of individual studies and participants.”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“Using such shielding systems to attenuate the field at the OPM array has been shown to allow naturalistic motion during MEG studies of an individual subject [24,34]”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“Recently, ‘wearable’ MEG has been developed through the use of optically pumped magnetometers (OPMs) [24]”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Event-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Über das Elektrenkephalogramm des Menschen
Berger, H. (1929) · Archiv für Psychiatrie und Nervenkrankheiten · doi:10.1007/bf01797193 · Cited by 4,235
Frequency Dependence of Signal Power and Spatial Reach of the Local Field Potential
Leski, S., Lindén, H., Tetzlaff, T., Pettersen, K. H., & Einevoll, G. T. (2013) · PubMed · doi:10.18154/rwth-conv-084442 · Cited by 3,639
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561 · cited 1×
“In the static case, motion was less than ±1 cm whereas in the moving case it exceeded ±10 cm. Panel (ii) shows an image23,24 of beta modulation (pink overlay) whilst panel (iii) shows a time-frequency spectrogram (TFS) of oscillatory change.”
Abnormal neural oscillations and synchrony in schizophrenia
Uhlhaas, P. J., & Singer, W. (2010) · Nature Reviews Neuroscience · doi:10.1038/nrn2774 · Cited by 2,120 · cited 1×
“Although simple, this task has been applied widely, with beta modulation being used as a marker of brain plasticity18,19, psychosis20,21 and white matter degradation22.”
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
The Resolving Power of Gross Earth Data
Backus, G., & Gilbert, F. (1968) · Geophysical Journal International · doi:10.1111/j.1365-246x.1968.tb00216.x · Cited by 1,523
Large-scale cortical correlation structure of spontaneous oscillatory activity
Hipp, J. F., Hawellek, D. J., Corbetta, M., Siegel, M., & Engel, A. K. (2012) · Nature Neuroscience · doi:10.1038/nn.3101 · Cited by 1,113 · cited 1×
“For example, it is well known that efficient communication between spatially separate cortical regions is key to healthy brain function, and that neural oscillations help mediate such connectivity28,29.”
Research works printed but not linked: 1
- Robinson, S. & Vrba, J. in Recent Advances in Biomagnetism (eds Yoshimoto, T. et al.) 302–305 (Tohoku Univ. Press, 1998)
Cited by
Items 501–600 of 999
Noisy Atomic Magnetometry with Kalman Filtering and Measurement-Based Feedback
Amorós-Binefa, J., & Kołodyński, J. (2025) · PRX Quantum · doi:10.1103/k7nk-lrwd · Cited by 23
Interactions between nonresonant rf fields and atoms with strong spin-exchange collisions
Hao, C., Qiu, Z., Sun, Q., Zhu, Y., & Sheng, D. (2019) · Physical Review A · doi:10.1103/physreva.99.053417 · Cited by 14
Fast and robust optically pumped cesium magnetometer
Lebedev, V., Hartwig, S., & Middelmann, T. (2019) · Advanced Optical Technologies · doi:10.1515/aot-2020-0024 · Cited by 14
Single-Beam Miniaturized Atomic Magnetometer With Square-Wave Modulation for Magnetoencephalography
Ding, Z., Han, B., & Tang, J. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3043947 · Cited by 15
Miniature Wide-Range Three-Axis Vector Atomic Magnetometer
Li, J., Yicheng, D., Wang, X., Lu, H., & Liu, Y. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3112522 · Cited by 14
Suppression Method of Light Shift in K-Rb Hybrid Optical Pumping SERF Atomic Comagnetometer
Liu, F., Duan, L., Fan, W., Pang, H., Liu, S., Wu, J., & Quan, W. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3122990 · Cited by 14
Ultra-sensitive all-optical comagnetometer with laser heating
Zhao, T., Liu, Y., Wei, K., Xie, H.-T., Mu, T., Fang, X., Xu, Z., & Zhai, Y. (2022) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ac49b5 · Cited by 14
Pu, Y., Cornwell, B. R., Cheyne, D., & Johnson, B. W. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.05.029 · Cited by 14
Macauda, G., Moisa, M., Mast, F. W., Ruff, C. C., Michels, L., & Lenggenhager, B. (2019) · Cortex · doi:10.1016/j.cortex.2019.04.004 · Cited by 20
A synthetic optically pumped gradiometer for magnetocardiography measurements*
Zhang, S., & Cao, N. (2020) · Chinese Physics B · doi:10.1088/1674-1056/ab7801 · Cited by 14
Lonser, R. R., Zipfel, G. J., & Chiocca, E. A. (2020) · Journal of neurosurgery · doi:10.3171/2020.4.jns201202 · Cited by 16
In-Situ Relaxation Rate Measurement in Magnetic Modulated Atomic Magnetometers
Yin, K., Zhou, B., Lu, J., Lu, F., Zhang, S., Yan, Y., & Ye, M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3131734 · Cited by 15
Vinding, M. C., & Oostenveld, R. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119165 · Cited by 16
Growth of single-crystalline 2D materials for advanced quantum sensing devices
Goel, N., Kushwaha, A., Raj, M., Aswin, A., Chaurasiya, R., Shinde, N. B., Pradhan, A., & Upadhyay, R. K. (2025) · Applied Physics Reviews · doi:10.1063/5.0232976 · Cited by 14
Wearable smart sensors integration with AI and machine learning for tracking human health
Xianyong, S., Mishra, D. K., Özcan, Ö. Ö., Karahan, M., Panpan, T., Zhongshan, X., & Kumar, P. V. (2025) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2025.100711 · Cited by 31
The Space Density Distribution of Alkali Metal Atoms in a SERF Atomic Magnetometer
Guo, Q., Li, X., Zhang, N., Lu, J., Ma, D., Li, Z., & Jiang, S. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3146415 · Cited by 13
Lifetime estimation model of vapor cells in atomic magnetometers
Liu, Z., Zou, S., Yin, K., Zhou, B., Ning, X., & Yuan, H. (2022) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ac677b · Cited by 12
Temperature characteristics of Rb-N2 single-beam magnetometer with different buffer gas pressures
Zhang, S., Zhou, Y., Lu, F., Yan, Y., Wang, W., Zhou, B., Zhai, Y., Lu, J., & Ye, M. (2023) · Measurement · doi:10.1016/j.measurement.2023.112860 · Cited by 13
Microstructural evolution and enhanced magnetic properties of FeCoNiZrx medium entropy alloy films
Li, Z., Wang, F., Zhao, C., Liao, Y., Gao, M. X., & Zhang, H. (2023) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2023.172649 · Cited by 13
Epileptic brain network mechanisms and neuroimaging techniques for the brain network
Guo, Y., Lin, Z., Fan, Z., & Tian, X. (2023) · Neural Regeneration Research · doi:10.4103/1673-5374.391307 · Cited by 13
“Unlike a traditional superconducting quantum interference device-based MEG, the advanced OPM-based MEG can be carried out at room temperature without using a large Dewar flask of liquid helium for cooling (Sander et al., 2012; Boto et al., 2018).”
BackgroundMethodPerspective: magnetic quantum sensors for biomedical applications
Wu, K., & He, R. (2025) · Nanotechnology · doi:10.1088/1361-6528/adb635 · Cited by 19
“Commercial products of OPM for MEG are already available at suppliers such as Brainbox Ltd. Numerous clinical applications of OPMs for wearable MEG recording have been demonstrated in recent years [18, 19, 32–34].”
Xu, W., Liao, P., Cao, M., White, D., Lyu, B., & Gao, J. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2025.121182 · Cited by 19
“The finger-tapping task has been widely used to evaluate the functionality of OPM-MEG since its initial applications (Boto et al., 2018; Sey-mour et al., 2022; Rier et al., 2024).”
Zeidman, P., Ashburner, J., Barnes, G. R., Kowalczyk, O. S., Lambert, C., Litvak, V., Nichols, T. E., Parr, T., Tierney, T. M., & Friston, K. J. (2025) · Cerebral Cortex · doi:10.1093/cercor/bhaf234 · Cited by 14
Self-citationLiang, S., & Mody, M. (2022) · Frontiers in Neuroimaging · doi:10.3389/fnimg.2022.903191 · Cited by 14
Faraday-Rotation Atomic Magnetometer Using Triple-Chromatic Laser Beam
Zhang, Y., Tian, Y., Li, S., Chen, J., & Gu, S. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.12.011004 · Cited by 12
Decoding Speech Evoked Jaw Motion from Non-invasive Neuromagnetic Oscillations
Dash, D., Ferrari, P., & Wang, J. (2020) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn48605.2020.9207448 · Cited by 13
“Although current MEG is not-portable, recent studies on next-generation movable MEG devices based on optically pumped magnetometers [30] have the potential to be used for BCI applications in the near future.”
BackgroundA high performance active noise control system for magnetic fields
Pyragius, T., & Jensen, K. (2021) · Review of Scientific Instruments · doi:10.1063/5.0062650 · Cited by 19
Magnetic Field Mapping and Correction for Moving OP-MEGPreprint
Mellor, S., Tierney, T. M., O’Neill, G. C., Alexander, N., Seymour, R. A., Holmes, N., López, J. D., Hill, R. M., Boto, E., Rea, M., et al. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.05.25.444975 · Cited by 13
“If the sensors can continuously be kept close to their optimal (0 T) operating point this also mitigates the gain errors (~1 % per nT [9], [13], [14], [37]) which are incurred as a result of operating at an offset field during movement.”
BackgroundInfluentialSelf-citationChi, H., Yuan, H., Cai, Z., Wang, X., Shang, H., Hu, Z., & Zhou, B. (2021) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ac2f13 · Cited by 13
“The study of MEG can promote the cognition of the human brain, the diagnosis of epilepsy, and other neurological diseases [1–3].”
Ma, Y., Zhang, K., Wang, Y., Yang, K., Zhai, Y., & Lu, J. (2022) · Optics Express · doi:10.1364/oe.459995 · Cited by 12
Lü, H., Zhang, Y., Huang, P., Zhang, Y., Cheng, S., & Zhu, X. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.931265 · Cited by 14
Li, S., Xing, B., Fang, X., Wang, K., Gao, Y., Wei, Q., & Han, B. (2023) · Results in Physics · doi:10.1016/j.rinp.2023.106546 · Cited by 14
Research on the anti-interference ability of optically pumped magnetometer
Li, L., Ding, Z., Tang, J., Zhao, B., & Zhai, Y. (2023) · Measurement · doi:10.1016/j.measurement.2023.113405 · Cited by 12
Optically pumped magnetometers based on pseudo-random-bit-sequence phase modulation
Ma, N., Duan, L., Fang, X., Xing, B., Ma, D., Lu, J., & Han, B. (2023) · Applied Physics Letters · doi:10.1063/5.0164896 · Cited by 12
Liang, S., Gao, K., He, J., Jia, Y., Jiao, H., & Feng, L. (2023) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2023.11.004 · Cited by 13
Yang, K. Y., Zhang, Y., Zhao, A., Zhang, H., Zhang, Q., Rui, D., Wang, X., & Huang, D. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3353279 · Cited by 12
Combining OPM and lesion mapping data for epilepsy surgery planning: a simulation study
Mellor, S., Timms, R. C., O’Neill, G. C., Tierney, T. M., Spedden, M. E., Spitzer, H., Ripart, M., Whitaker, K. J., Napolitano, A., Palma, L. D., et al. (2024) · Scientific Reports · doi:10.1038/s41598-024-51857-3 · Cited by 14
Self-citationJaufenthaler, A., Sander, T. H., Schier, P. P., Pansegrau, K., Wiekhorst, F., & Baumgarten, D. (2024) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2024.171983 · Cited by 14
Sai, T., Wang, P., Gu, X., Xu, X., Sun, J., & Ye, J. (2024) · Materials Today Advances · doi:10.1016/j.mtadv.2024.100487 · Cited by 12
Suppression of spin-exchange relaxation in Bell-Bloom magnetometer
Fang, C., Jiang, L., Liu, J., Chen, Y., Zhu, J., Shao, Q., Zou, Y., Xiang, M., & Quan, W. (2024) · Measurement · doi:10.1016/j.measurement.2024.115695 · Cited by 14
Vector magnetometry employing a rotating RF field in a single-beam optically pumped magnetometer
Zou, Y., Jiang, L., Bai, H., Liu, J., Fang, C., Zhu, J., Shao, Q., Xu, J., Zhou, X., & Quan, W. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115901 · Cited by 12
A non-magnetic packaged Vertical-Cavity Surface-Emitting Laser for SERF magnetometers
Zhou, P., Zhang, G., Liang, Z., Hu, J., Liu, L., Hu, G., Wang, A., Du, P., & Ye, M. (2024) · Measurement · doi:10.1016/j.measurement.2024.116381 · Cited by 13
Sleep neuroimaging: Review and future directions
Pereira, M., Chen, X., Paltarzhytskaya, A., Pacheсo, Y., Muller, N., Bovy, L., Lei, X., Chen, W., Ren, H., Song, C., et al. (2025) · Journal of Sleep Research · doi:10.1111/jsr.14462 · Cited by 21
“Recent developments in wearable MEG based on optically pumped magnetometers (Boto et al., 2018) have granted this electrophysiological imaging method a considerable advantage in comparison to neuroimaging modalities relying on rigid scanners such as MRI or PET.”
Chai, C., Yang, X. M., Zheng, Y., Heyat, M. B. B., Li, Y., Yang, D.-B., Chen, Y.-H., & Sawan, M. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117321 · Cited by 14
Automatic Speech Activity Recognition from MEG Signals Using Seq2Seq Learning
Dash, D., Ferrari, P., Malik, S. I., & Wang, J. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8717186 · Cited by 12
Westin, K., Pfeiffer, C., Andersen, L. M., Ruffieux, S., Cooray, G., Kalaboukhov, A., Winkler, D., Ingvar, M., Schneiderman, J. F., & Lundqvist, D. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.03.041 · Cited by 12
All-optical spin locking in alkali-metal-vapor magnetometers
Bao, G., Kanta, D., Antypas, D., Rochester, S., Jensen, K., Zhang, W., Wickenbrock, A., & Budker, D. (2022) · Physical Review A · doi:10.1103/physreva.105.043109 · Cited by 14
Guo, Q., Hu, T., Feng, X., Zhang, M., Chen, C.-Q., Zhang, X., Yao, Z.-K., Xu, J.-Y., Wang, Q., Fu, F.-Y., et al. (2022) · Chinese Physics B · doi:10.1088/1674-1056/ac7e38 · Cited by 12
Optimal Design of Planar Coils With Reverse Current Distribution for Atomic Devices
Wang, S., Lu, J., Lu, F., Lu, C., & Zhang, X. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3214619 · Cited by 15
Everaert, K., Sander, T. H., Körber, R., Löwa, N., Waeyenberge, B. V., Leliaert, J., & Wiekhorst, F. (2023) · Nanoscale Advances · doi:10.1039/d3na00016h · Cited by 13
Yttrium-Iron Garnet Magnetometer in MEG: Advance towards Multi-Channel Arrays
Skidchenko, E., Butorina, A. V., Ostras, M., Vetoshko, P. M., Kuzmichev, A. N., Yavich, N. B., Malovichko, M., & Koshev, N. (2023) · Sensors · doi:10.3390/s23094256 · Cited by 14
Collaborative Filtering with Preferences Inferred from Brain Signals
Davis, K. M., Spapé, M., & Ruotsalo, T. (2021) · International World Wide Web Conference (WWW) · doi:10.1145/3442381.3450031 · Cited by 19
“for brain-computer interfaces (BCIs) is currently inhibited by its cumbersome user experience, lack of portability, and considerable cost, steps towards developing more user-friendly wearable MEG are being undertaken [8].”
BackgroundSensitive spatially resolved magnetometry using a Bose-condensed gas with a bright probe
Sekiguchi, N., Shibata, K., Torii, A., Toda, H., Kuramoto, R., Fukuda, D., & Hirano, T. (2021) · Physical Review A · doi:10.1103/physreva.104.l041306 · Cited by 12
Han, C., Xu, M., Tang, J., Liu, Y., & Zhou, Z. (2022) · Virtual Reality & Intelligent Hardware · doi:10.1016/j.vrih.2022.01.003 · Cited by 13
Wireless optically pumped magnetometer MEG
Cheng, H., He, K., Li, C., Ma, X., Zheng, F., Xu, W., Liao, P., Yang, R., Li, D., Qin, L., et al. (2024) · NeuroImage · doi:10.1016/j.neuroimage.2024.120864 · Cited by 11
Flexible brain electronic sensors advance wearable brain-computer interface
Li, J., Chen, G., Li, G., Xiao, L., Jia, R., & Zhang, K. (2025) · npj Biomedical Innovations. · doi:10.1038/s44385-025-00029-7 · Cited by 14
“The strength of brain signals is weak, for example, electroencephalography signals are measured to be merely 10 – 50 μ V and magnetoencephalogram signals originating of synchronized activity of 10 5 neurons show about 100fT in intensity 18,19 .”
Wang, R., Yu-jie, M., Zhao, R., Ding, J., Li, L., Yang, Y., Wang, F., Cao, Z., Zhang, X., Lin, X., et al. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2025.121403 · Cited by 12
What Has Been Learned from Using EEG Methods in Research of ADHD?
McLoughlin, G., Gyurkovics, M., & Aydın, Ü. (2022) · Current topics in behavioral neurosciences · doi:10.1007/7854_2022_344 · Cited by 12
Li, R., Liu, Y., Li, J., Cao, Q., Huang, B., & Zhai, Y. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114781 · Cited by 11
Li, J., Liu, Y., Li, R., Cao, Q., Zhou, T., & Zhai, Y. (2023) · Results in Physics · doi:10.1016/j.rinp.2023.107231 · Cited by 11
Measurement of Relaxation Mechanism for the Spin-Exchange Relaxation-Free Magnetometer
Peng, J., Xu, A., Yin, Y., & Liu, B. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3334710 · Cited by 12
“…not only helps in advanced research of physics, including searching for spin-dependent interactions [1], [2] and dark matter [3], [4], but also contributes significantly in multiple applications, such as biomedicine, geographical survey, mining industry, ocean development, and so on [5], [6], [7].”
BackgroundA Magnetic Susceptibility Measurement System Based on a Single-Axis Atomic Magnetometer
Sun, Y., Lu, J., Zhou, Y., Wang, Y., & Zhou, Z. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3366312 · Cited by 11
“Currently, optically pumped magnetometers have been applied in various fields, including the measurement of biomagnetic signals [20], [21], [22], geomagnetic measurements [23], dark matter detection [24], nondestructive testing of batteries [25], and nuclear magnetic resonance [26], among others.”
BackgroundLi, R., Liu, Y., Li, J., Cao, Q., Huang, B., & Zhai, Y. (2024) · Optics & Laser Technology · doi:10.1016/j.optlastec.2024.111217 · Cited by 11
Vandewouw, M. M., Sato, J., Safar, K., Rhodes, N., & Taylor, M. J. (2024) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2024.101433 · Cited by 14
“There have been numerous demonstrations and discussions about the robustness of OPM-MEG to head motion given its wearable nature (Barry et al., 2019; Boto et al., 2018; R. M. Hill et al., 2019; Pedersen et al., 2022; Seedat et al., 2024; Seymour et al., 2021), and new paradigms have been designed…”
BackgroundTowards non-invasive imaging through spinal-cord generated magnetic fields
Spedden, M. E., O’Neill, G. C., Tierney, T. M., West, T. O., Schmidt, M., Mellor, S., Farmer, S. F., Bestmann, S., & Barnes, G. R. (2024) · Frontiers in Medical Technology · doi:10.3389/fmedt.2024.1470970 · Cited by 12
“Over the last 10 years, OPMs have been used to develop a new approach to magnetoencephalography (MEG) (57 – 59), and the technique shows signi fi cant potential for spinal cord imaging.”
MethodSelf-citationWang, X., Teng, P., Meng, Q., Jiang, Y., Wu, J., Li, T., Wang, M., Guan, Y., Zhou, J., Sheng, J., et al. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad9680 · Cited by 15
“As previously reported, the magnetically-shielded room typically have a residual magnetic field about 25 nT and a gradient about 10 nT m − 1 [32].”
Xu, X., Zhao, Z., Liu, W., & Wu, W. (2024) · Measurement · doi:10.1016/j.measurement.2024.116295 · Cited by 11
Robotic Hand Exoskeletons for Rehabilitation and Assistance: A State-of-the-Art
Chen, B., Wu, Y., Ni, X., Qin, L.-Y., & Li, E. (2024) · Journal of Medical Devices · doi:10.1115/1.4067350 · Cited by 13
Rhodes, N., Rier, L., Singh, K. D., Sato, J., Vandewouw, M. M., Holmes, N., Boto, E., Hill, R. M., Rea, M., Taylor, M. J., et al. (2025) · Imaging Neuroscience · doi:10.1162/imag_a_00527 · Cited by 19
Self-citationFully integrated quantum magnetometer based on nitrogen-vacancy centers
Wang, Y., Zhang, W., Chai, H., Zhang, Z., Lin, S., Qin, X., & Jiang-Feng, D. (2025) · Physical Review Applied · doi:10.1103/physrevapplied.23.034008 · Cited by 11
Parameters optimization of optical pumped Mz/Mx magnetometer based on rf-discharge lamp
Ke, H.-L., Hao, J., Han, B., Miao, P.-X., Zhang, J., Tu, J., Yang, W., Jing-zhong, C., Chen, J., & Liu, Z. (2020) · Optik · doi:10.1016/j.ijleo.2020.165510 · Cited by 11
Broadening of magnetic linewidth by spin-exchange interaction in the K-Rb-21Ne comagnetometer
Wei, K., Zhao, T., Fang, X., Xu, Z., Zhai, Y., Quan, W., & Han, B. (2020) · Optics Express · doi:10.1364/oe.404259 · Cited by 12
Ferromagnetic Resonance Vector Magnetic Sensor with High Sensitivity and Ultrawide Working Range
Wen, T., Wang, Z., Du, Q., Su, W., Guan, M., Zhao, S., Wu, J., Hu, Z., Zhou, Z., & Liu, M. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202100919 · Cited by 11
Yang, K., Zhang, H., Zhang, Q.-N., Zha, J.-J., & Huang, D.-C. (2022) · Chinese Physics B · doi:10.1088/1674-1056/ac6163 · Cited by 10
Single-beam comagnetometer using elliptically polarized light for dual-axis rotation measurement
Liang, Y., Jiang, L., Liu, J., Zhu, J., Shao, Q., Fan, S., Li, X., & Quan, W. (2022) · Optics Express · doi:10.1364/oe.470656 · Cited by 11
Chen, Y., Zhao, L., Ma, Y., Yu, M., Wang, Y., Zhang, N., Wei, K., & Jiang, Z. (2022) · Biomedical Optics Express · doi:10.1364/boe.474862 · Cited by 11
Dawson, R., O’Dwyer, C., Irwin, E., Mrozowski, M. S., Hunter, D., Ingleby, S. J., Riis, E., & Griffin, P. F. (2023) · Sensors · doi:10.3390/s23084007 · Cited by 12
“The sensitivity of commercial OPMs approaches that of SQUIDs while providing functional [1] and longitudinal [2] studies with an important new tool.”
BackgroundXu, J., Zhang, X., Fan, S., Li, Y., Wang, Y., Gao, S., Long, Y., Zhang, Y., Wang, X., Cao, D., et al. (2023) · Ceramics International · doi:10.1016/j.ceramint.2023.05.048 · Cited by 11
Tensor gradiometry with a diamond magnetometer
Newman, A. J., Graham, S. M., Edmonds, A. M., Twitchen, D. J., Markham, M., & Morley, G. W. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.014003 · Cited by 11
“…monitoring [15,16], unexploded ordnance detection [17], space missions, and geological surveys [11,18–20] and could be applied to areas such as archaeology, nondestructive testing [21], magnetocardiog-raphy [22], magnetoencephalography [23–27], and nuclear magnetic resonance spectroscopy [28].”
Li, R., Zhai, Y., Li, J., Cao, Q., & Liu, Y. (2024) · Advanced Quantum Technologies · doi:10.1002/qute.202300287 · Cited by 11
In Situ Calibration of Magnetic Coil System Using Ellipticity-Induced Bell-Bloom Magnetometer
Zhang, G., Huang, S.-J., & Lin, Q. (2018) · IEEE photonics journal · doi:10.1109/jphot.2018.2889578 · Cited by 11
The Impact of Transient Ischemic Attack (TIA) on Brain and Behavior
Simmatis, L. E. R., Scott, S. H., & Jin, A. Y. (2019) · Frontiers in Behavioral Neuroscience · doi:10.3389/fnbeh.2019.00044 · Cited by 21
Magneto-optical spectroscopy with arbitrarily polarized intensity-modulated light in He4 atoms
Wang, H., Wu, T., Wang, H., Peng, X., & Guo, H. M. (2020) · Physical Review A · doi:10.1103/physreva.101.063408 · Cited by 13
Benefits and threats of neuromarketing: theoretical background and practical use
Antoniak, M. A. (2020) · Scientific Papers of Silesian University of Technology Organization and Management Series · doi:10.29119/1641-3466.2020.148.1 · Cited by 15
Testing covariance models for MEG source reconstruction of hippocampal activity
O’Neill, G. C., Barry, D. N., Tierney, T. M., Mellor, S., Maguire, E. A., & Barnes, G. R. (2021) · Scientific Reports · doi:10.1038/s41598-021-96933-0 · Cited by 10
Self-citationThe Uncertainty Quantification for Parameters Optimization in SERF Atomic Magnetomer
Zhao, W., Li, Y., Wang, Y., Yan, Q., Song, Q., Wang, C., Kang, X., & Gao, X. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3116312 · Cited by 11
Yang, N., Liu, F., Zhang, X., Chen, C., Xia, Z., Fu, S., Wang, J., Xu, J., Cui, S., Zhang, Y., et al. (2022) · Biosensors · doi:10.3390/bios12020129 · Cited by 11
“Without surgeries on the cranium, technical developments of 3D visualization of functional magnetic resonance imaging (fMRI) [1–4], magnetoencephalography (MEG) [5], positron emission computed tomography (PET) [6] sequence images, electroencephalogram (EEG) [7,8], functional near–infrared spectroscopy (fNIRS) [9,10],…”
BackgroundInfluentialBrain-wide neural co-activations in resting human
Ding, L., Shou, G., Cha, Y., Sweeney, J. A., & Yuan, H. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119461 · Cited by 13
Atom-based quantum sensing of electromagnetic fields
Kitching, J. E., Shaffer, J. P., & Budker, D. (2025) · Optica · doi:10.1364/optica.569334 · Cited by 18
Age differences in central auditory system responses to naturalistic music
Haumann, N. T., Petersen, B., Vuust, P., & Brattico, E. (2023) · Biological Psychology · doi:10.1016/j.biopsycho.2023.108566 · Cited by 11
Automatic Sensor Array Calibration and Coregistration for On-Scalp MEG
Pang, M., Huang, Z., Ding, Z., & Han, B. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3277096 · Cited by 10
Lightweight Privacy-Preserving Feature Extraction for EEG Signals Under Edge Computing
Yan, N., Cheng, H., Liu, X., Chen, F., & Wang, M. (2023) · IEEE Internet of Things Journal · doi:10.1109/jiot.2023.3292232 · Cited by 12
“Meanwhile, various companies have launched consumer-level BCI devices that capture brain activity via EEG signals to facilitate the use of BCI headphones [17].”
BackgroundNoise Reduction and Localization Accuracy in a Mobile Magnetoencephalography System
Bardouille, T., Smith, V., Vajda, E., Leslie, C. D., & Holmes, N. (2024) · Sensors · doi:10.3390/s24113503 · Cited by 12
Self-citationIn-situ magnetic fields monitoring and compensation for zero-field atomic magnetometers
Yan, Y., Zhang, K., Liu, Z., Liu, Z., Li, X., Zhou, Y., & Lu, J. (2024) · Measurement · doi:10.1016/j.measurement.2024.115410 · Cited by 11
Shi, Y., Guo, X., Liu, X., Tang, J., Zhai, Y., & Feng, R. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3449978 · Cited by 10
Femtotesla atomic magnetometer with counter-propagating optical sideband pumping
Peng, J., Xu, A., & Liu, B. (2024) · Optics Letters · doi:10.1364/ol.540032 · Cited by 10
Bandwidth compensation for ultra-high-sensitivity SERF magnetometers in magnetocardiac sensing
Jia, Y., Pei, H., Yang, Y., Jiang, L., Lu, J., Ning, X., Cui, Y., & Xiang, M. (2024) · Measurement · doi:10.1016/j.measurement.2024.116095 · Cited by 10
Optimized Magnetic Field Matrix Modeling and Adjustive Excitation in a Multiplex Compensation System
Zhang, L., Shi, M., Zhang, X., Yang, J., Tian, K., Ma, Y., Shi, Z., & Liu, G. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3527604 · Cited by 12
Qi, S., Song, X., Jia, L., Duan, Z., Dai, Y., Zhang, J., & Ning, X. (2025) · NeuroImage · doi:10.1016/j.neuroimage.2025.121078 · Cited by 11
Rhodes, N., Rier, L., Boto, E., Hill, R. M., & Brookes, M. J. (2025) · Imaging Neuroscience · doi:10.1162/imag.a.8 · Cited by 15
Self-citation
Metadata
- Authors
- Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., Barnes, G. R., Bowtell, R., & Brookes, M. J.
- Affiliations
- University of Nottingham (GB)
- QuSpin (United States) (US)
- Wellcome Centre for Human Neuroimaging (GB)
- Corresponding author
- Brookes, Matthew J.
- ORCID
- Venue
- Nature
- Published
- 2018-03
- Volume
- 555
- Issue
- 7698
- Pages
- 657-661
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- PMC
- PMC6063354
- OpenAlex
- W2791548393
- Cited by
- 1,377
- References
- 51
- Citations by year
- 2026: 174 · 2025: 236 · 2024: 196 · 2023: 175 · 2022: 175 · 2021: 161 · 2020: 111 · 2019: 107 · 2018: 40
- FWCI
- 48.05
- Type
- journal article
- Language
- en
- Open access
- Licence
- other-oa
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Nottingham ePrints (University of Nottingham) (acceptedVersion)
- University of Birmingham Research Portal (University of Birmingham) (acceptedVersion, other-oa)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Repository@Nottingham (University of Nottingham) (acceptedVersion, other-oa)
- Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Funders
- Wellcome Trust (203147/Z/16/Z, 203257/Z/16/Z, 203257BARNES, 203257/B/16/Z)
- National Institutes of Health (203257/Z/16/Z, 203257/B/16/Z)
- Medical Research Council (MR/K005464/1, MR/M006301/1, 203147/Z/16/Z)
- Engineering and Physical Sciences Research Council (MR/K005464/1, 1652749, 203147/Z/16/Z, 203257/B/16/Z, EP/M013294/1, EP/M013294, 203257/Z/16/Z)
- National Institute of Mental Health (R44MH110288)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R44HD074495)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- quantum sensors, movement disorders, brain function imaging
- MeSH terms
- Wearable Electronic Devices, Adult, Drinking, Female, Head, Humans, Movement, Sports, Magnetoencephalography, Magnetic Fields
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.