Moving magnetoencephalography towards real-world applications with a wearable system
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
Imaging human brain function with techniques such as magnetoencephalography typically requires a subject to perform tasks while their head remains still within a restrictive scanner. This artificial environment makes the technique inaccessible to many people, and limits the experimental questions that can be addressed. For example, it has been difficult to apply neuroimaging to investigation of the neural substrates of cognitive development in babies and children, or to study processes in adults that require unconstrained head movement (such as spatial navigation). Here we describe a magnetoencephalography system that can be worn like a helmet, allowing free and natural movement during scanning. This is possible owing to the integration of quantum sensors, which do not rely on superconducting technology, with a system for nulling background magnetic fields. We demonstrate human electrophysiological measurement at millisecond resolution while subjects make natural movements, including head nodding, stretching, drinking and playing a ball game. Our results compare well to those of the current state-of-the-art, even when subjects make large head movements. The system opens up new possibilities for scanning any subject or patient group, with myriad applications such as characterization of the neurodevelopmental connectome, imaging subjects moving naturally in a virtual environment and investigating the pathophysiology of movement disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Although, there have been some studies on recording the MEG signal of moving participants in a MSR (44) and the unshielded static MEG measurements (35, 37), a MEG system that is both unshielded and movable remains to be developed.”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [44]
The cited source says what the claim attributes to it.
In the citing paper
“OPMs are sensitive magnetic field sensors that do not require cryogenics.”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“These devices have enabled the design of flexible MEG sensor arrays, which can be placed closer to the scalp, and adapted to the requirements of individual studies and participants.”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“Using such shielding systems to attenuate the field at the OPM array has been shown to allow naturalistic motion during MEG studies of an individual subject [24,34]”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
The cited source says what the claim attributes to it.
In the citing paper
“Recently, ‘wearable’ MEG has been developed through the use of optically pumped magnetometers (OPMs) [24]”
From Naturalistic Hyperscanning with Wearable Magnetoencephalography (2023) · cites this paper as [24]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Event-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Über das Elektrenkephalogramm des Menschen
Berger, H. (1929) · Archiv für Psychiatrie und Nervenkrankheiten · doi:10.1007/bf01797193 · Cited by 4,235
Frequency Dependence of Signal Power and Spatial Reach of the Local Field Potential
Leski, S., Lindén, H., Tetzlaff, T., Pettersen, K. H., & Einevoll, G. T. (2013) · PubMed · doi:10.18154/rwth-conv-084442 · Cited by 3,639
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561 · cited 1×
“In the static case, motion was less than ±1 cm whereas in the moving case it exceeded ±10 cm. Panel (ii) shows an image23,24 of beta modulation (pink overlay) whilst panel (iii) shows a time-frequency spectrogram (TFS) of oscillatory change.”
Abnormal neural oscillations and synchrony in schizophrenia
Uhlhaas, P. J., & Singer, W. (2010) · Nature Reviews Neuroscience · doi:10.1038/nrn2774 · Cited by 2,120 · cited 1×
“Although simple, this task has been applied widely, with beta modulation being used as a marker of brain plasticity18,19, psychosis20,21 and white matter degradation22.”
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
The Resolving Power of Gross Earth Data
Backus, G., & Gilbert, F. (1968) · Geophysical Journal International · doi:10.1111/j.1365-246x.1968.tb00216.x · Cited by 1,523
Large-scale cortical correlation structure of spontaneous oscillatory activity
Hipp, J. F., Hawellek, D. J., Corbetta, M., Siegel, M., & Engel, A. K. (2012) · Nature Neuroscience · doi:10.1038/nn.3101 · Cited by 1,113 · cited 1×
“For example, it is well known that efficient communication between spatially separate cortical regions is key to healthy brain function, and that neural oscillations help mediate such connectivity28,29.”
Research works printed but not linked: 1
- Robinson, S. & Vrba, J. in Recent Advances in Biomagnetism (eds Yoshimoto, T. et al.) 302–305 (Tohoku Univ. Press, 1998)
Cited by
Quantum sensors for biomedical applications
Aslam, N., Zhou, H., Urbach, E. K., Turner, M. J., Walsworth, R. L., Lukin, M. D., & Park, H. (2023) · Nature Reviews Physics · doi:10.1038/s42254-023-00558-3 · Cited by 527
Hyperscanning: A Valid Method to Study Neural Inter-Brain Underpinnings of Social Interaction
Czeszumski, A., Eustergerling, S., Lang, A., Menrath, D., Gerstenberger, M., Schuberth, S., Schreiber, F., Rendon, Z. Z., & König, P. (2020) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.00039 · Cited by 511
Materials and Designs for Wearable Photodetectors
Cai, S., Xu, X., Yang, W., Chen, J., & Fang, X. (2019) · Advanced Materials · doi:10.1002/adma.201808138 · Cited by 445
The physics of brain network structure, function and control
Lynn, C. W., & Bassett, D. S. (2019) · Nature Reviews Physics · doi:10.1038/s42254-019-0040-8 · Cited by 400
From Gaze Perception to Social Cognition: The Shared-Attention System
Stephenson, L. J., Edwards, S. G., & Bayliss, A. P. (2021) · Perspectives on Psychological Science · doi:10.1177/1745691620953773 · Cited by 437
“There have been recent strides toward this with the development of wearable MEG systems (Boto et al., 2018) and the use of virtual reality (Pan & Hamilton, 2018), which may herald more naturalistic interactions becoming the norm in the future.”
BackgroundBrookes, M. J., Leggett, J., Rea, M., Hill, R. M., Holmes, N., Boto, E., & Bowtell, R. (2022) · Trends in Neurosciences · doi:10.1016/j.tins.2022.05.008 · Cited by 412
“This means high quality MEG data can be acquired and, even if participants move, OPMs continue to function [16].”
BackgroundInfluentialSelf-citationOptically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400
“Outside of sensory cortex, OPMs have been used to study the motor system while the subject is free to move (Boto et al., 2018) and (in one example of a distributed array) to localise and lateralise language function in the human brain (Tierney et al., 2018).”
BackgroundMethodSelf-citationSpin Hyperpolarization in Modern Magnetic Resonance
Eills, J., Budker, D., Cavagnero, S., Chekmenev, E. Y., Elliott, S. J., Jannin, S., Lesage, A., Matysik, J., Meersmann, T., Prisner, T., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00534 · Cited by 368
Zhang, X., Wang, X., Lei, Z., Wang, L., Tian, M., Zhu, S., Xiao, H., Tang, X., & Qu, L. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c01182 · Cited by 358
Keep it real: rethinking the primacy of experimental control in cognitive neuroscience
Nastase, S. A., Goldstein, A., & Hasson, U. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117254 · Cited by 344
“…(iEEG; e.g., Wang et al., 2016), functional near-infrared spectroscopy (fNIRS; e.g., Liu et al., 2017), high-density diffuse optical tomography (HD-DOT; e.g., Fishell et al., 2019), and wearable magnetoencephalography (MEG; Boto et al., 2018) promise higher-fidelity and more ergonomic neuroimaging.”
BackgroundManipulating Relative Permittivity for High-Performance Wearable Triboelectric Nanogenerators
Jin, L., Xiao, X., Deng, W., Nashalian, A., He, D., Raveendran, V., Yan, C., Su, H., Chu, X., Yang, T., et al. (2020) · Nano Letters · doi:10.1021/acs.nanolett.0c01987 · Cited by 319
Multi-Channel Whole-Head OPM-MEG: Helmet Design and a Comparison with a Conventional System
Hill, R. M., Boto, E., Rea, M., Holmes, N., Leggett, J., Coles, L. A., Papastavrou, M., Everton, S. K., Hunt, B. A. E., Sims, D., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116995 · Cited by 285
“Here we did not attempt to tease apart environmental shifts and participant movement, but one could, either using reference array signals, or by motion tracking (Boto et al., 2018; Hill et al., 2019).”
InfluentialSelf-citationOn-scalp MEG system utilizing an actively shielded array of optically-pumped magnetometers
Iivanainen, J., Zetter, R., Grön, M., Hakkarainen, K., & Parkkonen, L. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.022 · Cited by 269
Portable Magnetometry for Detection of Biomagnetism in Ambient Environments
Limes, M. E., Foley, E. L., Kornack, T. W., Caliga, S., McBride, S., Braun, A., Lee, W., Lucivero, V. G., & Romalis, M. V. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.14.011002 · Cited by 257
Li, B.-B., Ou, L., Lei, Y., & Liu, Y.-C. (2021) · Nanophotonics · doi:10.1515/nanoph-2021-0256 · Cited by 251
“Ultrasensitive magnetic field sensing has various important applications, such as magnetic anomaly detection [136], mineral exploration [137], MRI [138, 139], and magnetoencephalography (MEG) [140, 141].”
BackgroundHolmes, N., Leggett, J., Boto, E., Roberts, G., Hill, R. M., Tierney, T. M., Shah, V., Barnes, G. R., Brookes, M. J., & Bowtell, R. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.07.028 · Cited by 250
Self-citationPernet, C., Garrido, M. I., Gramfort, A., Maurits, N., Michel, C. M., Pang, E., Salmelin, R., Schoffelen, J. M., Valdes-Sosa, P. A., & Puce, A. (2020) · Nature Neuroscience · doi:10.1038/s41593-020-00709-0 · Cited by 244
Rational Design of Flexible Zn-Based Batteries for Wearable Electronic Devices
Xiao, X., Zheng, Z., Zhong, X., Gao, R., Piao, Z., Jiao, M., & Zhou, G. (2023) · ACS Nano · doi:10.1021/acsnano.2c09509 · Cited by 236
Recording brain activities in unshielded Earth’s field with optically pumped atomic magnetometers
Zhang, R., Xiao, W., Ding, Y., Feng, Y., Peng, X., Shen, L., Sun, C., Wu, T., Wu, Y., Yang, Y., et al. (2020) · Science Advances · doi:10.1126/sciadv.aba8792 · Cited by 222
“The MEG system typically uses two different kinds of magne tometers as the magnetic sensors, the superconducting quantum interference devices (SQUIDs) (15–17) or the optically pumped atomic magnetometers (OPMs) (18–25).”
MethodInfluentialChanging concepts in presurgical assessment for epilepsy surgery
Zijlmans, M., Zweiphenning, W., & van Klink, N. (2019) · Nature Reviews Neurology · doi:10.1038/s41582-019-0224-y · Cited by 217
Decoding speech perception from non-invasive brain recordings
Défossez, A., Caucheteux, C., Rapin, J., Kabeli, O., & King, J.-R. (2023) · Nature Machine Intelligence · doi:10.1038/s42256-023-00714-5 · Cited by 215
“MEG and EEG are sensitive to macroscopic changes of electric and magnetic signals elicited in the cortex, and can be acquired with a safe and potentially wearable setup [14].”
BackgroundHramov, A. E., Maksimenko, V. A., & Pisarchik, A. N. (2021) · Physics Reports · doi:10.1016/j.physrep.2021.03.002 · Cited by 213
Boto, E., Shah, V., Hill, R. M., Rhodes, N., Osborne, J., Doyle, C., Holmes, N., Rea, M., Leggett, J., Bowtell, R., et al. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119027 · Cited by 187
“, 2015) and motion robustness has enabled a number of demonstrations of novel paradigms, from ball games (Boto et al., 2018) to virtual reality (Roberts et al.”
BackgroundSelf-citationMobile cognition: imaging the human brain in the ‘real world’
Stangl, M., Maoz, S. L., & Suthana, N. (2023) · Nature Reviews Neuroscience · doi:10.1038/s41583-023-00692-y · Cited by 183
A tool for functional brain imaging with lifespan compliance
Hill, R. M., Boto, E., Holmes, N., Hartley, C., Seedat, Z. A., Leggett, J., Roberts, G., Shah, V., Tierney, T. M., Woolrich, M. W., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-12486-x · Cited by 180
“Having derived this inner surface, it was fitted, visually, to the MRI of the same 2-year-old used in (1).”
BackgroundMethodInfluentialSelf-citationHiguera-Trujillo, J. L., Llinares, C., & Macagno, E. (2021) · Sensors · doi:10.3390/s21062193 · Cited by 176
“In contrast, MEG measures the magnetic fields generated by the ionic current [243].”
BackgroundBrain leaks and consumer neurotechnology
Ienca, M., Haselager, P., & Emanuel, E. J. (2018) · Nature Biotechnology · doi:10.1038/nbt.4240 · Cited by 173
IFCN-endorsed practical guidelines for clinical magnetoencephalography (MEG)
Hari, R., Baillet, S., Barnes, G., Burgess, R., Forss, N., Gross, J., Hämäläinen, M., Jensen, O., Kakigi, R., Mauguière, F., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.03.042 · Cited by 167
Self-citationHolmes, N., Tierney, T. M., Leggett, J., Boto, E., Mellor, S., Roberts, G., Hill, R. M., Shah, V., Barnes, G. R., Brookes, M. J., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-50697-w · Cited by 163
“ r g twoDFT i k S k k e k z ( ) ( ( , ) sinh( )) (5) i xj x j x y k a r i x y 0 , r”
BackgroundSelf-citationMagnetoencephalography in Cognitive Neuroscience: A Primer
Gross, J. (2019) · Neuron · doi:10.1016/j.neuron.2019.07.001 · Cited by 160
Non-Invasive Functional-Brain-Imaging with an OPM-based Magnetoencephalography System
Borna, A., Carter, T. R., Colombo, A. P., Jau, Y.-Y., McKay, J., Weisend, M., Taulu, S., Stephen, J. M., & Schwindt, P. D. D. (2020) · PLOS ONE · doi:10.1371/journal.pone.0227684 · Cited by 158
Advances in Multimodal Emotion Recognition Based on Brain–Computer Interfaces
He, Z., Li, Z., Yang, F., Wang, L., Li, J., Zhou, C., & Pan, J. (2020) · Brain Sciences · doi:10.3390/brainsci10100687 · Cited by 183
“A team of researchers [107] at the University of Nottingham in the UK has developed a magnetoencephalography system that can be worn like a helmet that allows the scanned person to move freely and naturally during the scanning process.”
BackgroundWearable Triboelectric Nanogenerators for Therapeutics
Xiao, X., Chen, G., Libanori, A., & Chen, J. (2021) · Trends in Chemistry · doi:10.1016/j.trechm.2021.01.001 · Cited by 154
Theoretical advantages of a triaxial optically pumped magnetometer magnetoencephalography system
Brookes, M. J., Boto, E., Rea, M., Shah, V., Osborne, J., Holmes, N., Hill, R. M., Leggett, J., Rhodes, N., & Bowtell, R. W. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118025 · Cited by 165
Self-citationNeuropsychological tests of the future: How do we get there from here?
Bilder, R. M., & Reise, S. P. (2018) · The Clinical Neuropsychologist · doi:10.1080/13854046.2018.1521993 · Cited by 168
He, B., Yuan, H., Meng, J., & Gao, S. (2020) · Springer eBooks · doi:10.1007/978-3-030-43395-6_4 · Cited by 167
Feys, O., Corvilain, P., Aeby, A., Sculier, C., Holmes, N., Brookes, M., Goldman, S., Wens, V., & De Tiège, X. (2022) · Radiology · doi:10.1148/radiol.212453 · Cited by 144
“This reflects the reduced (approximately 3 cm on average) brain-to-sensor distance afforded by using OPMs (4).”
BackgroundInfluentialSelf-citationTowards real-world generalizability of a circuit for action-stopping
Hannah, R., & Aron, A. R. (2021) · Nature reviews. Neuroscience · doi:10.1038/s41583-021-00485-1 · Cited by 154
Towards OPM-MEG in a Virtual Reality Environment
Roberts, G., Holmes, N., Alexander, N., Boto, E., Leggett, J., Hill, R. M., Shah, V., Rea, M., Vaughan, R., Maguire, E. A., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.010 · Cited by 128
“This has been the topic of recent work (Boto et al., 2018; Holmes et al., 2018; Iivanainen et al., 2018) , which has shown that appropriately designed”
BackgroundMethodInfluentialSelf-citationWearable neuroimaging: Combining and contrasting magnetoencephalography and electroencephalography
Boto, E., Seedat, Z. A., Holmes, N., Leggett, J., Hill, R. M., Roberts, G., Shah, V., Fromhold, T. M., Mullinger, K. J., Tierney, T. M., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116099 · Cited by 136
Self-citationZheng, L., Deng, X., Wang, Y., Chen, J., Fang, X., Wang, L., Shi, X., & Zheng, H. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202001604 · Cited by 136
Measuring functional connectivity with wearable MEG
Boto, E., Hill, R. M., Rea, M., Holmes, N., Seedat, Z. A., Leggett, J., Shah, V., Osborne, J., Bowtell, R. W., & Brookes, M. J. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.117815 · Cited by 142
“Wearable helmets mean that sensors move with the head, removing worries around subject movement which can lead to data becoming unusable in cryogenic systems (Boto et al., 2018).”
Self-citationNanotesla sensitivity magnetic field sensing using a compact diamond nitrogen-vacancy magnetometer
Webb, J. L., Clement, J. D., Troise, L., Ahmadi, S., Johansen, G. J., Huck, A., & Andersen, U. L. (2019) · Applied Physics Letters · doi:10.1063/1.5095241 · Cited by 129
Decoding Imagined and Spoken Phrases From Non-invasive Neural (MEG) Signals
Dash, D., Ferrari, P., & Wang, J. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00290 · Cited by 135
“Although current MEG machines are non-portable and costly, a recent study on wearable MEG (Boto et al., 2018) showed the potential of building next-generation, portable MEG devices.”
BackgroundTang, J., Zhai, Y., Li, C., Zhang, Y., Li, L., Zhao, B., Zhou, B., Han, B., & Liu, G. (2021) · Optics Express · doi:10.1364/oe.425851 · Cited by 125
The Treachery of Images: How Realism Influences Brain and Behavior
Snow, J. C., & Culham, J. C. (2021) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2021.02.008 · Cited by 137
A lightweight magnetically shielded room with active shielding
Holmes, N., Rea, M., Chalmers, J., Leggett, J., Edwards, L. J., Nell, P., Pink, S., Patel, P., Wood, J., Murby, N., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-17346-1 · Cited by 121
Self-citationYeh, C., Kao, F., Wei, P., Pal, A., Kaswan, K., Huang, Y., Parashar, P., Yeh, H., Wang, T.-W., Tiwari, N., et al. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.107852 · Cited by 125
Borna, A., Iivanainen, J., Carter, T. R., McKay, J., Taulu, S., Stephen, J., & Schwindt, P. D. D. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2021.118818 · Cited by 120
Precision magnetic field modelling and control for wearable magnetoencephalography
Rea, M., Holmes, N., Hill, R. M., Boto, E., Leggett, J., Edwards, L. J., Woolger, D., Dawson, E., Shah, V., Osborne, J., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118401 · Cited by 132
“…field, a rotation of ~4° would generate sufficient hange in field to take an OPM outside its ± 1.5 nT dynamic range (dened here as a 5% gain error) ( Boto et al., 2018 ; Iivanainen et al., 2019 ). ven if the sensor were to remain working, the resulting magnetic arteact would be much larger in…”
InfluentialSelf-citationTierney, T. M., Alexander, N., Mellor, S., Holmes, N., Seymour, R. A., O’Neill, G. C., Maguire, E. A., & Barnes, G. R. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118484 · Cited by 133
Self-citationInterference suppression techniques for OPM-based MEG: Opportunities and challenges
Seymour, R. A., Alexander, N., Mellor, S., O’Neill, G. C., Tierney, T. M., Barnes, G. R., & Maguire, E. A. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118834 · Cited by 138
“Recent neuroscientific work has used OPMs to detect a range of neuromagnetic fields whilst participants made natural head movements, for example, betaband modulations during a “ping-pong” paradigm (Boto et al., 2018; Holmes et al., 2018), and auditory evoked fields during continuous head movement while standing (Seymo…”
Self-citationWalking enhances peripheral visual processing in humans
Cao, L., & Händel, B. (2019) · PLoS Biology · doi:10.1371/journal.pbio.3000511 · Cited by 134
A hybrid magnetometer towards femtotesla sensitivity under ambient conditions
Xie, Y., Yu, H., Zhu, Y., Qin, X., Rong, X., Duan, C., & Du, J. (2020) · 中国科学通报:英文版 · doi:10.1016/j.scib.2020.08.001 · Cited by 122
“Magnetic field sensing technologies are crucial in many applications, such as magnetocardiography and magnetoencephalography [1,2], geomagnetic survey [3], and metallic contaminant detection [4].”
BackgroundFlexible and Wearable Power Sources for Next‐Generation Wearable Electronics
Fan, X., Liu, B., Ding, J., Deng, Y., Han, X., Hu, W., & Zhong, C. M. (2020) · Batteries & Supercaps · doi:10.1002/batt.202000115 · Cited by 116
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
“Although, there have been some studies on recording the MEG signal of moving participants in a MSR ( 44 ) and the unshielded static MEG measurements ( 35 , 37 ), a MEG system that is both unshielded and movable remains to be developed.”
Diamond Magnetometry and Gradiometry Towards Subpicotesla dc Field Measurement
Zhang, C., Shagieva, F., Widmann, M., Kübler, M., Vorobyov, V., Kapitanova, P., Nenasheva, E., Corkill, R., Rhrle, O., Nakamura, K., et al. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.15.064075 · Cited by 136
A 90-Channel Triaxial Magnetoencephalography System Using Optically Pumped Magnetometers
Rea, M., Boto, E., Holmes, N., Hill, R., Osborne, J., Rhodes, N., Leggett, J., Rier, L., Bowtell, R., Shah, V., et al. (2022) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.14890 · Cited by 102
Self-citationSensitive magnetometry in challenging environments
Fu, K. C., Iwata, G. Z., Wickenbrock, A., & Budker, D. (2020) · AVS Quantum Science · doi:10.1116/5.0025186 · Cited by 132
Miniaturized Magnetic Sensors for Implantable Magnetomyography
Zuo, S., Heidari, H., Farina, D., & Nazarpour, K. (2020) · Advanced Materials Technologies · doi:10.1002/admt.202000185 · Cited by 114
Multifunction integration within magnetic CNT-bridged MXene/CoNi based phase change materials
Gao, Y., Chen, X., Xu, J. B., Zhang, C., Zhang, X., Liu, X., Li, Y., Li, Y., Lin, J., Gao, H., et al. (2024) · eScience · doi:10.1016/j.esci.2024.100292 · Cited by 115
Limits of Low Magnetic Field Environments in Magnetic Shields
Sun, Z., Fierlinger, P., Han, J., Li, L., Liu, T., Schnabel, A., Stuiber, S., & Voigt, J. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2987267 · Cited by 109
“in a commercial product lead to a MEG system wearable by patients who can move freely and are no longer fixed to a stationary detector system [10].”
Tactile sensor from self-chargeable piezoelectric supercapacitor
Wang, N., Dou, W., Hao, S., Cheng, Y., Zhou, D., Huang, X., Jiang, C., & Cao, X. (2018) · Nano Energy · doi:10.1016/j.nanoen.2018.11.065 · Cited by 105
Han, B., Yang, J., Zhang, X., Shi, M., Yuan, S., & Wang, L. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3159961 · Cited by 105
“3159961 (OPM) [3], are widely applied in fundamental physics experiments [4], [5] and magnetoencephalography (MEG) studies [6], [7].”
BackgroundUsing OPMs to measure neural activity in standing, mobile participants
Seymour, R. A., Alexander, N., Mellor, S., O'Neill, G. C., Tierney, T. M., Barnes, G. R., & Maguire, E. A. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118604 · Cited by 102
Self-citationBrain–Computer Interface-Controlled Exoskeletons in Clinical Neurorehabilitation: Ready or Not?
Colucci, A., Vermehren, M., Cavallo, A., Angerhöfer, C., Peekhaus, N., Zollo, L., Kim, W., Paik, N., & Soekadar, S. R. (2022) · Neurorehabilitation and neural repair · doi:10.1177/15459683221138751 · Cited by 124
Potential of on‐scalp MEG: Robust detection of human visual gamma‐band responses
Iivanainen, J., Zetter, R., & Parkkonen, L. T. (2019) · Human Brain Mapping · doi:10.1002/hbm.24795 · Cited by 106
Inter-Subject Variability of Skull Conductivity and Thickness in Calibrated Realistic Head Models
Antonakakis, M., Schrader, S., Aydın, Ü., Khan, A., Groß, J., Zervakis, M., Rampp, S., & Wolters, C. H. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117353 · Cited by 123
Quantum‐Based Magnetic Field Sensors for Biosensing
Bao, B., Hua, Y., Wang, R., & Li, D. (2023) · Advanced Quantum Technologies · doi:10.1002/qute.202200146 · Cited by 108
Parameter Modeling Analysis of a Cylindrical Ferrite Magnetic Shield to Reduce Magnetic Noise
Ma, D., Lu, J., Fang, X., Yang, K., Wang, K., Zhang, N., Han, B., & Ding, M. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2021.3050351 · Cited by 99
How to build a magnetometer with thermal atomic vapor: a tutorial
Fabricant, A. M., Novikova, I. V., & Bison, G. (2023) · New Journal of Physics · doi:10.1088/1367-2630/acb840 · Cited by 162
Holmes, N., Rea, M., Hill, R. M., Leggett, J., Edwards, L. J., Hobson, P. J., Boto, E., Tierney, T. M., Rier, L., Rivero, G. R., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120157 · Cited by 89
“Although data could be recorded during the MEG experiment conducted with the coils switched off the effect of non-linearities induced into the sensor must be considered when evaluating the benefits of field nulling using a coil system (Boto et al., 2018; Iivanainen et al., 2019).”
Self-citationTang, J., Zhai, Y., Zhou, B., Han, B., & Liu, G. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3112797 · Cited by 102
Beyond simple laboratory studies: Developing sophisticated models to study rich behavior
Maselli, A., Gordon, J. R., Eluchans, M., Lancia, G. L., Thiery, T., Moretti, R., Cisek, P., & Pezzulo, G. (2023) · Physics of Life Reviews · doi:10.1016/j.plrev.2023.07.006 · Cited by 109
Brain at Work and in Everyday Life as the Next Frontier: Grand Field Challenges for Neuroergonomics
Dehais, F., Karwowski, W., & Ayaz, H. (2020) · Frontiers in Neuroergonomics · doi:10.3389/fnrgo.2020.583733 · Cited by 97
“Similarly, portable magnetoencephalography portable devices are starting to be developed and becoming a new complementary media to investigate human cognition (Boto et al., 2018).”
BackgroundMarzetti, L., Basti, A., Chella, F., D’Andrea, A., Syrjälä, J., & Pizzella, V. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00964 · Cited by 101
Cross-species neuroscience: closing the explanatory gap
Barron, H. C., Mars, R. B., Dupret, D., Lerch, J. P., & Sampaio‐Baptista, C. (2020) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.2019.0633 · Cited by 95
“These new sensors offer a significant advantage over SQUIDs as they can be placed directly on the scalp, increasing the magnitude of the measured signal [13] but also permitting signal acquisition as the participant moves [10].”
BackgroundMethodHybrid Optimal Design of Square Highly Uniform Magnetic Field Coils
Lu, J., Wang, S., Lu, F., Lu, C., Zhang, X., & Ma, D. (2022) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3179547 · Cited by 88
“Atomic magnetometers are used to detect weak magnetic fields and require a miniaturized design to meet the conditions of array measurements in magnetoencephalograms and magnetocardiograms [16], [17].”
MethodMouth magnetoencephalography: A unique perspective on the human hippocampus
Tierney, T. M., Levy, A. D., Barry, D. N., Meyer, S. S., Shigihara, Y., Everatt, M., Mellor, S., López, J. D., Bestmann, S., Holmes, N., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117443 · Cited by 89
“, 2018) was used, in conjunction with a reference array (comprising 4 OPMs placed immediately behind the participant), to cancel any remaining static background field inside the MSR; specifically, reference array measurements enabled calculation of optimised coil currents to remove the static field, and its first orde…”
BackgroundMethodSelf-citationNoreika, V., Georgieva, S., Wass, S. V., & Leong, V. (2019) · Infant Behavior and Development · doi:10.1016/j.infbeh.2019.101393 · Cited by 100
Nardelli, N. V., Perry, A. R., Krzyzewski, S., & Knappe, S. A. (2020) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-020-00086-4 · Cited by 89
The road towards understanding embodied decisions
Gordon, J. R., Maselli, A., Lancia, G. L., Thiery, T., Cisek, P., & Pezzulo, G. (2021) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2021.09.034 · Cited by 111
Three-axis closed-loop optically pumped magnetometer operated in the SERF regime
Yan, Y., Lu, J., Zhang, S., Lu, F., Yin, K., Wang, K., Zhou, B., & Liu, G. (2022) · Optics Express · doi:10.1364/oe.458367 · Cited by 89
Tang, J., Liu, Y., Wang, Y., Zhou, B., Han, B., Zhai, Y., & Liu, G. (2022) · Applied Physics Letters · doi:10.1063/5.0080764 · Cited by 87
Measurement of Frontal Midline Theta Oscillations using OPM-MEG
Rhodes, N., Rea, M., Boto, E., Rier, L., Shah, V., Hill, R. M., Osborne, J., Doyle, C., Holmes, N., Coleman, S. C., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120024 · Cited by 94
Self-citationIntegrated Optically Pumped Magnetometer for Measurements within Earth’s Magnetic Field
Oelsner, G., IJsselsteijn, R. P. J., Scholtes, T., Krüger, A., Schultze, V., Seyffert, G., Werner, G. R., Jäger, M., Chwala, A., & Stolz, R. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.024034 · Cited by 105
“, avoiding the need for cryogenics or gaining higher flexibility due to smaller sensor sizes [9, 10].”
BackgroundFunctional Use of Eye Movements for an Acting System
de Brouwer, A. J., Flanagan, J. R., & Spering, M. (2021) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2020.12.006 · Cited by 92
“MEG [92] may lead to new discoveries concerning the neural mechanisms underlying eye–hand interaction and coupling.”
BackgroundInfluentialPromises and challenges of human computational ethology
Mobbs, D., Wise, T., Suthana, N., Guzman, N., Kriegeskorte, N., & Leibo, J. Z. (2021) · Neuron · doi:10.1016/j.neuron.2021.05.021 · Cited by 95
“Further, with the creation of moveable optically pumped magnetometer magnetoencephalography (OPM-MEG; (Boto et al., 2018)), providing electrophysiological measurements at the millisecond resolution, there is promise in combining VR with spatially and temporally high-resolution brain imaging on a…”
BackgroundBrain-Machine Interfaces: Powerful Tools for Clinical Treatment and Neuroscientific Investigations
Slutzky, M. W. (2018) · The Neuroscientist · doi:10.1177/1073858418775355 · Cited by 90
Functional ultrasound imaging of deep visual cortex in awake nonhuman primates
Blaize, K., Arcizet, F., Gesnik, M., Ahnine, H., Ferrari, U., Deffieux, T., Pouget, P., Chavane, F., Fink, M., Sahel, J., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1916787117 · Cited by 88
Diamond Integrated Quantum Nanophotonics: Spins, Photons and Phonons
Shandilya, P. K., Flågan, S., Carvalho, N. C., Zohari, E., Kavatamane, V. K., Losby, J. E., & Barclay, P. E. (2022) · Journal of Lightwave Technology · doi:10.1109/jlt.2022.3210466 · Cited by 97
“(OPM) [336] offer the highest sensitivities to bio-magnetic fields and dominate these biomedical applications (MEG and MCG).”
BackgroundInfluentialReducing crosstalk in optically-pumped magnetometer arrays
Nardelli, N. V., Krzyzewski, S., & Knappe, S. A. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab4c06 · Cited by 82
“Unless two magnetometers are very close and are oriented at an angle that is large, this effect is small (a maximum of 5°) (Boto et al 2018).”
BackgroundRecent advancements in flexible and wearable sensors for biomedical and healthcare applications
Wang, Y., Yang, B., Hua, Z., Zhang, J., Guo, P., Hao, D., Gao, Y., & Huang, J. (2021) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ac3c73 · Cited by 92
Using OPM-MEG in contrasting magnetic environments
Hill, R. M., Devasagayam, J., Holmes, N., Boto, E., Shah, V., Osborne, J., Safar, K., Worcester, F., Mariani, C., Dawson, E., et al. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119084 · Cited by 92
Self-citationJensen, K., Skarsfeldt, M. A., Stærkind, H., Arnbak, J., Balabas, M. V., Olesen, S.-P., Bentzen, B. H., & Polzik, E. S. (2018) · Scientific Reports · doi:10.1038/s41598-018-34535-z · Cited by 79
Deforming the metric of cognitive maps distorts memory
Bellmund, J. L. S., de Cothi, W., Ruiter, T. A., Nau, M., Barry, C., & Doeller, C. F. (2019) · Nature Human Behaviour · doi:10.1038/s41562-019-0767-3 · Cited by 85
Cross-species anxiety tests in psychiatry: pitfalls and promises
Bach, D. R. (2021) · Molecular Psychiatry · doi:10.1038/s41380-021-01299-4 · Cited by 84
Recent Advances in Transparent Electrodes and Their Multimodal Sensing Applications
Althumayri, M. O., Das, R., Banavath, R., Beker, L., Achim, A., & Koydemir, H. C. (2024) · Advanced Science · doi:10.1002/advs.202405099 · Cited by 95
Spatially resolved neural slowing predicts impairment and amyloid burden in Alzheimer’s disease
Wiesman, A. I., Murman, D. L., Losh, R. A., Schantell, M. D., Christopher‐Hayes, N. J., Johnson, H. J., Willett, M. P., Wolfson, S. L., Losh, K. L., Johnson, C. M., et al. (2021) · Brain · doi:10.1093/brain/awab430 · Cited by 74
Imaging the human hippocampus with optically-pumped magnetoencephalography
Barry, D. N., Tierney, T. M., Holmes, N., Boto, E., Roberts, G., Leggett, J., Bowtell, R. W., Brookes, M. J., Barnes, G. R., & Maguire, E. A. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116192 · Cited by 82
Self-citation
Metadata
- Authors
- Boto, E., Holmes, N., Leggett, J., Roberts, G., Shah, V., Meyer, S. S., Muñoz, L. D., Mullinger, K. J., Tierney, T. M., Bestmann, S., Barnes, G. R., Bowtell, R., & Brookes, M. J.
- Affiliations
- University of Nottingham (GB)
- QuSpin (United States) (US)
- Wellcome Centre for Human Neuroimaging (GB)
- Corresponding author
- Brookes, Matthew J.
- ORCID
- Venue
- Nature
- Published
- 2018-03
- Volume
- 555
- Issue
- 7698
- Pages
- 657-661
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- PMC
- PMC6063354
- OpenAlex
- W2791548393
- Cited by
- 1,377
- References
- 51
- Citations by year
- 2026: 174 · 2025: 236 · 2024: 196 · 2023: 175 · 2022: 175 · 2021: 161 · 2020: 111 · 2019: 107 · 2018: 40
- FWCI
- 48.05
- Type
- journal article
- Language
- en
- Open access
- Licence
- other-oa
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- Nottingham ePrints (University of Nottingham) (acceptedVersion)
- University of Birmingham Research Portal (University of Birmingham) (acceptedVersion, other-oa)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Repository@Nottingham (University of Nottingham) (acceptedVersion, other-oa)
- Repository@Nottingham (University of Nottingham) (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Funders
- Wellcome Trust (203147/Z/16/Z, 203257/Z/16/Z, 203257BARNES, 203257/B/16/Z)
- National Institutes of Health (203257/Z/16/Z, 203257/B/16/Z)
- Medical Research Council (MR/K005464/1, MR/M006301/1, 203147/Z/16/Z)
- Engineering and Physical Sciences Research Council (MR/K005464/1, 1652749, 203147/Z/16/Z, 203257/B/16/Z, EP/M013294/1, EP/M013294, 203257/Z/16/Z)
- National Institute of Mental Health (R44MH110288)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R44HD074495)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Keywords
- quantum sensors, movement disorders, brain function imaging
- MeSH terms
- Wearable Electronic Devices, Adult, Drinking, Female, Head, Humans, Movement, Sports, Magnetoencephalography, Magnetic Fields
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.