A shear gradient-activated microfluidic device for automated monitoring of whole blood haemostasis and platelet function
Open accessThe DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Abstract
Accurate assessment of blood haemostasis is essential for the management of patients who use extracorporeal devices, receive anticoagulation therapy or experience coagulopathies. However, current monitoring devices do not measure effects of haemodynamic forces that contribute significantly to platelet function and thrombus formation. Here we describe a microfluidic device that mimics a network of stenosed arteriolar vessels, permitting evaluation of blood clotting within small sample volumes under pathophysiological flow. By applying a clotting time analysis based on a phenomenological mathematical model of thrombus formation, coagulation and platelet function can be accurately measured in vitro in patient blood samples. When the device is integrated into an extracorporeal circuit in pig endotoxemia or heparin therapy models, it produces real-time readouts of alterations in coagulation ex vivo that are more reliable than standard clotting assays. Thus, this disposable device may be useful for personalized diagnostics and for real-time surveillance of antithrombotic therapy in clinic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Microfluidic perfusion models that are used to model early stage atherosclerosis and later thrombosis have a significant potential in drug development [291–294].”
From Cardiovascular disease models: A game changing paradigm in drug discovery and screening (2019) · cites this paper as [293]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288 · cited 7×
“( c ) Photograph of three haemostasis monitoring devices formed in a single piece of PDMS mould on top of a standard glass slide (75 (cid:4) 50mm).”
MethodInfluentialA shear gradient–dependent platelet aggregation mechanism drives thrombus formation
Nesbitt, W. S., Westein, E., Tovar-Lopez, F. J., Tolouei, E., Mitchell, A., Fu, J., Carberry, J., Fouras, A., & Jackson, S. P. (2009) · Nature Medicine · doi:10.1038/nm.1955 · Cited by 862 · cited 3×
“Notably, flow acceleration and deceleration (fluid shear gradients) have been shown to initiate platelet aggregation during arterial thrombosis in vivo 14,15 , and clotting in extracorporeal devices usually occurs at sites of sudden flow disturbances, stagnation points and stenosed sections of tubing…”
Animal Models of sepsis: setting the stage
Buras, J. A., Holzmann, B., & Sitkovsky, M. (2005) · Nature Reviews Drug Discovery · doi:10.1038/nrd1854 · Cited by 843 · cited 1×
“…by intravenous infusion of lipopolysaccharide (LPS) are widely used to study disruption of haemostasis and intravascular coagulation owing to sepsis 33 Therefore, we first injected a lethal dose of LPS intravenously to the pig for 90 min and then monitored the coagulation state of the animal’s…”
Cho, Y. I., & Kensey, K. R. (1991) · Biorheology · doi:10.3233/bir-1991-283-415 · Cited by 823
A bioinspired omniphobic surface coating on medical devices prevents thrombosis and biofouling
Leslie, D. C., Waterhouse, A., Berthet, J. B., Valentin, T. M., Watters, A. L., Jain, A., Kim, P., Hatton, B. D., Nedder, A., Donovan, K., et al. (2014) · Nature Biotechnology · doi:10.1038/nbt.3020 · Cited by 758 · cited 2×
“When the blood was filled in a syringe and pushed, the syringe was manually agitated every 2–3min to prevent sedimentation of erythrocytes in the blood.”
Self-citationMicro- and Nanoscale Fluid Mechanics: Transport in Microfluidic Devices
Kirby, B. J. (2010) · Cited by 753
The growing complexity of platelet aggregation
Jackson, S. P. (2007) · Blood · doi:10.1182/blood-2006-12-027698 · Cited by 737 · cited 1×
“As platelet aggregation is a major contributor to the development of vascular occlusion, 29 we further explored if this biomimetic device can be used as a rapid platelet function assay under stenosed flow.”
Ganter, M. T., & Hofer, C. K. (2008) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318168b367 · Cited by 677
Hirsh, J., Dalen, J. E., Deykin, D., & Toller, L. (1992) · Chest · doi:10.1378/chest.102.4_supplement.337s · Cited by 558 · cited 2×
“4f) 26 .”
BackgroundExtracorporeal Membrane Oxygenation—Hemostatic Complications
Murphy, D. A., Hockings, L. E., Andrews, R. K., Aubron, C., Gardiner, E. E., Pellegrino, V. A., & Davis, A. K. (2015) · Transfusion Medicine Reviews · doi:10.1016/j.tmrv.2014.12.001 · Cited by 455
Cited by
Point-of-Care Diagnostics: Recent Developments in a Connected Age
Nayak, S., Blumenfeld, N. R., Laksanasopin, T., & Sia, S. K. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04630 · Cited by 508
Shrivastava, S., Trung, T. Q., & Lee, N.-E. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00319c · Cited by 497
Jain, A., Barrile, R., van der Meer, A., Mammoto, A., Mammoto, T., De Ceunynck, K., Aisiku, O., Otieno, M., Louden, C., Hamilton, G., et al. (2018) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.742 · Cited by 325
“Additionally, we found that this PBD index increased when we raised the hemodynamic shear rate from 275 s to 750 s in the microfluidic channel (by altering pumping rates), indicating a higher tendency to form platelet-rich thrombi and promote platelet-endothelial binding interactions in vitro (Figure 2d), as reported…”
ResultSelf-citationShear-Dependent Platelet Aggregation: Mechanisms and Therapeutic Opportunities
Rana, A., Westein, E., Niego, B., & Hagemeyer, C. E. (2019) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2019.00141 · Cited by 226
SERS-based microdevices for use as in vitro diagnostic biosensors
Lee, S., Dang, H., Moon, J.-I., Kim, K., Joung, Y., Park, S., Yu, Q., Chen, J., Lu, M., Chen, L., et al. (2024) · Chemical Society Reviews · doi:10.1039/d3cs01055d · Cited by 220
Bioprinted thrombosis-on-a-chip
Zhang, Y. S., Davoudi, F., Walch, P., Manbachi, A., Luo, X., Dell'Erba, V., Miri, A. K., Albadawi, H., Arneri, A., Li, X., et al. (2016) · Lab on a Chip · doi:10.1039/c6lc00380j · Cited by 227
Cardiovascular disease models: A game changing paradigm in drug discovery and screening
Savoji, H., Mohammadi, M. H., Rafatian, N., Toroghi, M. K., Wang, E. Y., Zhao, Y., Korolj, A., Ahadian, S., & Radisic, M. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.09.036 · Cited by 223
Tomaiuolo, M., Brass, L. F., & Stalker, T. J. (2017) · Interventional Cardiology Clinics · doi:10.1016/j.iccl.2016.08.001 · Cited by 192
Cochrane, A., Albers, H. J., Passier, R., Mummery, C. L., van den Berg, A., Orlova, V. V., & van der Meer, A. D. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.06.007 · Cited by 162
“Here, clotting times in the presence and absence of antiplatelet therapeutics were determined [74].”
BackgroundAssessment of whole blood thrombosis in a microfluidic device lined by fixed human endothelium
Jain, A., van der Meer, A. D., Papa, A.-L., Barrile, R., Lai, A., Schlechter, B. L., Otieno, M. A., Louden, C. S., Hamilton, G. A., Michelson, A. D., et al. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0095-6 · Cited by 148
“After 2 min, 100 mM calcium (CaCl2) and 75 mM magnesium (MgCl2) were added to the blood in the reservoir (1: 10 ratio) to restore coagulation-activated blood clotting (Jain et al. 2016; Neeves et al. 2014).”
MethodSelf-citationTyagi, T., Jain, K., Gu, S. X., Qiu, M., Gu, V. W., Melchinger, H. C., Rinder, H. M., Martin, K. A., Gardiner, E. E., Lee, A. I., et al. (2022) · Nature Cardiovascular Research · doi:10.1038/s44161-022-00021-z · Cited by 118
Emerging trends in multiscale modeling of vascular pathophysiology: Organ-on-a-chip and 3D printing
Gold, K. A., Gaharwar, A. K., & Jain, A. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.07.029 · Cited by 118
“Scanning electron micrographs of blood clot formation within the device, bottom, illustrating fibrin networks with red blood cell (3 left images) and activated platelets (2 images at right) [72].”
BackgroundSelf-citationMicrofluidics to Mimic Blood Flow in Health and Disease
Sebastian, B., & Dittrich, P. S. (2017) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-010816-060246 · Cited by 117
Ting, L. H., Feghhi, S., Taparia, N., Smith, A. O., Karchin, A., Lim, E. B., John, A. E. S., Wang, X., Rue, T. C., White, N. J., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-09150-9 · Cited by 109
Organ-on-a-chip technology: a novel approach to investigate cardiovascular diseases
Paloschi, V., Sabater‐Lleal, M., Middelkamp, H. H. T., Vivas, A., Johansson, S., van der Meer, A. D., Tenje, M., & Mäegdefessel, L. (2021) · Cardiovascular Research · doi:10.1093/cvr/cvab088 · Cited by 114
“Similarly, blood vessel-on-chips can be perfused with human blood from individuals treated with different anticoagulant therapies to assess drug response of specific patients in a personalized manner.(128)”
BackgroundMathur, T., Singh, K. A., Pandian, N. K. R., Tsai, S., Hein, T. W., Gaharwar, A. K., Flanagan, J. M., & Jain, A. (2019) · Lab on a Chip · doi:10.1039/c9lc00469f · Cited by 107
Self-citationTechnology Advancements in Blood Coagulation Measurements for Point-of-Care Diagnostic Testing
Aria, M. M., Erten, A. C., & Yalçın, Ö. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00395 · Cited by 100
“Fluorescence microscopy of fibrinogen and platelets also enables monitoring of thrombus formation at the same time (Jain et al., 2016a).”
BackgroundMenon, N. V., Tay, H. M., Pang, K. T., Dalan, R., Wong, S. C., Wang, X., Li, K. H. H., & Hou, H. W. (2018) · APL Bioengineering · doi:10.1063/1.4993762 · Cited by 96
SERS-based droplet microfluidics for high-throughput gradient analysis
Jeon, J., Choi, N., Chen, H., Moon, J., Chen, L., & Choo, J. (2019) · Lab on a Chip · doi:10.1039/c8lc01180j · Cited by 95
Cooperative unfolding of distinctive mechanoreceptor domains transduces force into signals
Ju, L. A., Chen, Y., Xue, L., Du, X., & Zhu, C. (2016) · eLife · doi:10.7554/elife.15447 · Cited by 91
“For example, in response to shear gradients resulting from flow perturbations, discoid platelets aggregate rapidly in a manner independent of agonist activation pathways (Jain et al., 2016; Nesbitt et al., 2009; Yong et al., 2011).”
BackgroundSaha, B., Mathur, T., Tronolone, J. J., Chokshi, M., Lokhande, G. K., Selahi, A., Gaharwar, A. K., Afshar-Kharghan, V., Sood, A. K., Bao, G., et al. (2021) · Science Advances · doi:10.1126/sciadv.abg5283 · Cited by 90
Self-citationEngineering Organ-on-a-Chip Systems for Vascular Diseases
Shakeri, A., Wang, Y., Zhao, Y., Landau, S., Perera, K., Lee, J., & Radisic, M. (2023) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.123.318233 · Cited by 96
Hartmann, J., Murphy, M., & Dias, J. D. (2020) · Diagnostics · doi:10.3390/diagnostics10020118 · Cited by 86
Mimicking Human Pathophysiology in Organ‐on‐Chip Devices
Yeşil-Çeliktaş, Ö., Hassan, S., Miri, A. K., Maharjan, S., Al‐kharboosh, R., Quiñones‐Hinojosa, A., & Zhang, Y. S. (2018) · Advanced Biosystems · doi:10.1002/adbi.201800109 · Cited by 80
Micro-electromechanical film bulk acoustic sensor for plasma and whole blood coagulation monitoring
Chen, D., Song, S., Ma, J., Zhang, Z., Wang, P., Liu, W., & Guo, Q. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.12.063 · Cited by 67
“The dependence of the maximum response on the activator concentration was in agreement with the results obtained from QCMs (Chang et al., 2000; Cheng et al., 1998; Vikinge et al., 2000b), SPR (Vikinge et al., 2000a) and the shear gradient-activated microfluidic device (Jain et al., 2016).”
BackgroundMethodResultAbdel-Mohsen, A. M., Franková, J., Abdel-Rahman, R. M., Salem, A. A., Sahffie, N. M., Kuběna, I., & Jancar, J. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.119349 · Cited by 69
Saha, B., Mathur, T., Handley, K. F., Hu, W., Afshar-Kharghan, V., Sood, A. K., & Jain, A. (2020) · Blood Advances · doi:10.1182/bloodadvances.2020001632 · Cited by 63
“In our past work, we have shown that vascular organ chips perform quantitative analysis of organ-level contributions to vascular dysfunction, platelet hyperactivity, and thrombosis.(14,15) Importantly, our vessel chip methods revealed mechanisms of vascular thrombosis and the drugendothelial interactions that are seen…”
BackgroundSelf-citationBiofabrication Strategies and Engineered In Vitro Systems for Vascular Mechanobiology
Pradhan, S., Banda, O. A., Farino, C. J., Sperduto, J. L., Keller, K. A., Taitano, R. A., & Slater, J. H. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901255 · Cited by 64
Thrombosis-on-a-chip: prospective impact of microphysiological models of vascular thrombosis
Pandian, N. K. R., Mannino, R. G., Lam, W. A., & Jain, A. (2018) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.12.001 · Cited by 56
Self-citationPandian, N. K. R., Walther, B. K., Suresh, R., Cooke, J. P., & Jain, A. (2020) · Small · doi:10.1002/smll.202003401 · Cited by 60
Self-citationGorog, D. A., Fayad, Z. A., & Fuster, V. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.08.065 · Cited by 55
Microfluidics‐Implemented Biochemical Assays: From the Perspective of Readout
Chen, W., Shao, F., & Xianyu, Y. (2019) · Small · doi:10.1002/smll.201903388 · Cited by 52
Remodeling of a Cell-Free Vascular Graft with Nanolamellar Intima into a Neovessel
Wang, Z., Liu, C., Xiao, Y., Gu, X., Xu, Y. Y., Dong, N., Zhang, S., Qin, Q., & Wang, J. (2019) · ACS Nano · doi:10.1021/acsnano.9b04704 · Cited by 50
Dynamics of Blood Flow and Thrombus Formation in a Multi-Bypass Microfluidic Ladder Network
Zilberman‐Rudenko, J., Sylman, J. L., Lakshmanan, H. H. S., McCarty, O. J. T., & Maddala, J. (2016) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-016-0470-7 · Cited by 49
Use of microfluidics to assess the platelet-based control of coagulation
Nagy, M., Heemskerk, J. W. M., & Swieringa, F. (2017) · Platelets · doi:10.1080/09537104.2017.1293809 · Cited by 51
Kang, Y. J., & Lee, S. J. (2018) · The Analyst · doi:10.1039/c8an00231b · Cited by 49
Using microfluidic devices to study thrombosis in pathological blood flows
Herbig, B. A., Yu, X., & Diamond, S. L. (2018) · Biomicrofluidics · doi:10.1063/1.5021769 · Cited by 49
SLIPS-LAB—A bioinspired bioanalysis system for metabolic evaluation of urinary stone disease
Li, H., Shkolyar, E., Wang, J., Conti, S. L., Pao, A. C., Liao, J. C., Wong, T., & Wong, P. K. (2020) · Science Advances · doi:10.1126/sciadv.aba8535 · Cited by 49
Thrombosis Models: An Overview of Common In Vivo and In Vitro Models of Thrombosis
Ayyoub, S., Orriols, R., Oliver, E., & Tura-Ceide, O. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24032569 · Cited by 47
Application of microfluidic devices in studies of thrombosis and hemostasis
Zhang, C., & Neelamegham, S. (2017) · Platelets · doi:10.1080/09537104.2017.1319047 · Cited by 41
Yeom, E., Kim, H. M., Park, J. H., Choi, W., Doh, J., & Lee, S. J. (2017) · Scientific Reports · doi:10.1038/s41598-017-01985-w · Cited by 40
Recent Progress in the Development of Microfluidic Vascular Models
Sato, K., & Sato, K. (2018) · Analytical Sciences · doi:10.2116/analsci.17r006 · Cited by 41
Meledeo, M. A., Herzig, M. C. S., Bynum, J. A., Wu, X., Ramasubramanian, A. K., Darlington, D. N., Reddoch, K. M., & Cap, A. P. (2017) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0000000000001431 · Cited by 39
“Miniaturized devices assess coagulation under pathophysiologic flows or under controlled conditions ex vivo, in real time, using small volumes.(77,78) POC machines can provide INR within 3 minutes.”
MethodMicrofluidics in Haemostasis: A Review
Panchal, H. J., Kent, N. J., Knox, A. J. S., & Harris, L. F. (2020) · Molecules · doi:10.3390/molecules25040833 · Cited by 38
Nguyen, N., Thurgood, P., Sekar, N. C., Chen, S., Pirogova, E., Peter, K., Baratchi, S., & Khoshmanesh, K. (2021) · Biophysical Reviews · doi:10.1007/s12551-021-00815-8 · Cited by 39
Effects of upstream shear forces on priming of platelets for downstream adhesion and activation
Rahman, S. M., Eichinger, C. D., & Hlady, V. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.04.002 · Cited by 37
Cinca-Morros, S., García-Rey, S., Álvarez‐Herms, J., Basabe‐Desmonts, L., & Benito‐Lopez, F. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.342988 · Cited by 38
Increasing access to microfluidics for studying fungi and other branched biological structures
Millet, L. J., Aufrecht, J. A., Labbé, J., Uehling, J., Vilgalys, R. J., Estes, M. L., Guennoc, C. M., Deveau, A., Olsson, S., Bonito, G. M., et al. (2019) · Fungal Biology and Biotechnology · doi:10.1186/s40694-019-0071-z · Cited by 36
Advances in Platelet-Dysfunction Diagnostic Technologies
Yoon, I., Han, J. H., & Jeon, H. (2024) · Biomolecules · doi:10.3390/biom14060714 · Cited by 34
“This device, which integrated a mathematical model for clotting analysis, enabled accurate in vitro coagulation and platelet-function measurements and offered real-time coagulation monitoring in pig models for endotoxemia and heparin therapy [94].”
MethodXu, Y., Yu, G., Nie, R., & Wu, Z. (2022) · Open Research (University of Surrey) · doi:10.1002/viw.20200183 · Cited by 34
Akther, F., Zhang, J., Nguyen, D. H. T., Fallahi, H., Adelnia, H., Phan, H., Nguyen, N., & Ta, H. T. (2022) · Advanced Biology · doi:10.1002/adbi.202101316 · Cited by 34
The role of valve stiffness in the insurgence of deep vein thrombosis
Schofield, Z., Baksamawi, H. A., Campos, J., Alexiadis, A., Nash, G. B., Brill, A. G., & Vigolo, D. (2020) · Communications Materials · doi:10.1038/s43246-020-00066-2 · Cited by 37
Downstream platelet adhesion and activation under highly elevated upstream shear forces
Rahman, S. M., & Hlady, V. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.04.028 · Cited by 33
Shea, S. M., Thomas, K. A., & Spinella, P. C. (2019) · Blood transfusion · doi:10.2450/2019.0095-19 · Cited by 30
Mathur, T., Tronolone, J. J., & Jain, A. (2021) · Journal of the American Heart Association · doi:10.1161/jaha.121.022795 · Cited by 32
Self-citationEmerging Microfluidic Approaches for Platelet Mechanobiology and Interplay With Circulatory Systems
Zhang, Y., Ramasundara, S. D. Z., Preketes-tardiani, R. E., Cheng, V., Lu, H., & Ju, L. A. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.766513 · Cited by 30
“(71); A network of parallel stenosed microchannels which contain multiple regions of pre-stenosis, stenosis and post-stenosis.”
BackgroundMethodJung, S. H., Jang, B. H., Kwon, S., Park, S. J., Park, T., & Kang, J. H. (2023) · Advanced Materials · doi:10.1002/adma.202211149 · Cited by 30
Acute and Chronic Cardiovascular Manifestations of COVID-19: Role for Endotheliopathy
Cooke, J. P., Connor, J. H., & Jain, A. (2021) · Methodist DeBakey Cardiovascular Journal · doi:10.14797/mdcvj.1044 · Cited by 28
Self-citationPlatelet activation via dynamic conformational changes of von Willebrand factor under shear
Pushin, D. M., Salikhova, T., Zlobina, K., & Guria, G. (2020) · PLoS ONE · doi:10.1371/journal.pone.0234501 · Cited by 27
“Shear gradients, as well as the duration of exposure to high shear stress, can influence the onset of SIPAct in the presence of VWF molecules [18,28,31,34,43,44].”
BackgroundIntegrating microfluidics, hydrogels, and 3D bioprinting for personalized vessel-on-a-chip platforms
Aye, S. S. S., Fang, Z., Wu, M. C. L., Lim, K. S., & Ju, L. A. (2025) · Biomaterials Science · doi:10.1039/d4bm01354a · Cited by 28
Zhao, Y. C., Zhang, Y., Wang, Z., Jiang, F., Kyanian, K., Aye, S. S. S., Hong, T., Vatankhah, P., Nasser, A., Sun, A., et al. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202214179 · Cited by 26
Point-of-Care Assessment of Hemostasis with a Love-Mode Surface Acoustic Wave Sensor
Chen, X., Wang, M., & Zhao, G. (2020) · ACS Sensors · doi:10.1021/acssensors.9b02382 · Cited by 26
ZnO Film Bulk Acoustic Resonator for the Kinetics Study of Human Blood Coagulation
Chen, D., Zhang, Z., Ma, J., & Wang, W. (2017) · Sensors · doi:10.3390/s17051015 · Cited by 25
“Based on these observation, the time-dependent frequency profiles of the FBAR sensor were fitted using a sigmoid curve [38] as follows:”
MethodPlatelet activation risk index as a prognostic thrombosis indicator
Zlobina, K., & Guria, G. (2016) · Scientific Reports · doi:10.1038/srep30508 · Cited by 25
“By applying the approach developed by De Gennes28 and his colleagues29 to the VWF dynamics under shear stress conditions on the surface of platelets, we obtained for the first time the exact expression (4) for the dependence of the critical shear rate of platelet activation on VWF multimer size.”
Microfluidic techniques for mechanical measurements of biological samples
Salipante, P. F. (2023) · Biophysics Reviews · doi:10.1063/5.0130762 · Cited by 27
Point of care whole blood microfluidics for detecting and managing thrombotic and bleeding risks
Diamond, S. L., & Rossi, J. M. (2021) · Lab on a Chip · doi:10.1039/d1lc00465d · Cited by 25
Luna, D. J., Pandian, N. K. R., Mathur, T., Bui, J., Gadangi, P., Kostousov, V. V., Hui, S. R., Teruya, J., & Jain, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-62768-4 · Cited by 23
Self-citationMicrofluidic-based biomimetic models for life science research
Jiang, K., Dong, C., Xu, Y., & Wang, L. (2016) · RSC Advances · doi:10.1039/c6ra05691a · Cited by 26
Physiological and Disease Models of Respiratory System Based on Organ-on-a-Chip Technology
Wang, D., Cong, Y., Deng, Q., Han, X., Zhang, S., Zhao, L., Luo, Y., & Zhang, X. (2021) · Micromachines · doi:10.3390/mi12091106 · Cited by 25
“The coagulation and platelet function can be accurately measured in vitro by analyzing the coagulation time based on the phenomenological mathematical model of thrombosis [75].”
MethodXu, S., Piao, J., Lee, B. K., Lim, C.-S., & Shin, S. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112395 · Cited by 22
Nguyen, T. Q., & Park, W. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.128590 · Cited by 23
Assessment of fibrinolytic status in whole blood using a dielectric coagulometry microsensor
Pourang, S., Sekhon, U. D. S., Disharoon, D., Ahuja, S. P., Suster, M. A., Gupta, A. S., & Mohseni, P. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114299 · Cited by 21
Ghosh, L. D., Mathur, T., Tronolone, J. J., Chuong, A. B., Rangel, K., Corvigno, S., Sood, A. K., & Jain, A. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202304263 · Cited by 21
Self-citationGriffin, M. T., Kim, D. A., & Ku, D. N. (2019) · Biomicrofluidics · doi:10.1063/1.5113508 · Cited by 21
Magnetic targeting to enhance microbubble delivery in an occluded microarterial bifurcation
Victor, M. D. S., Carugo, D., Barnsley, L. C., Owen, J., Coussios, C. C., & Stride, E. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa858f · Cited by 21
A single-particle mechanofluorescent sensor
Ahmadi, N., Lee, J., Godiya, C. B., Kim, J., & Park, B. J. (2024) · Nature Communications · doi:10.1038/s41467-024-50361-6 · Cited by 20
Zhao, Y. C., Wang, Z., Zhao, H., Yap, N. A., Wang, R., Cheng, W., Xu, X., & Ju, L. A. (2025) · ACS Sensors · doi:10.1021/acssensors.4c02764 · Cited by 21
Wen, J., Wan, N., Bao, H., & Li, J. (2019) · Sensors · doi:10.3390/s19051095 · Cited by 20
Organ-on-a-chip and 3D printing as preclinical models for medical research and practice
Jain, A., Mathur, T., Pandian, N. K. R., & Selahi, A. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-819178-1.00009-5 · Cited by 25
Self-citationVascular microphysiological systems (MPS): biologically relevant and potent models
Breuil, L., Kitada, A., Yadav, S., Zhou, H., Fujimoto, K., & Yokokawa, R. (2025) · Lab on a Chip · doi:10.1039/d5lc00014a · Cited by 19
PDMS-Zwitterionic Hybrid for Facile, Antifouling Microfluidic Device Fabrication
Mercader, A. L., Ye, S., Kim, S., Orizondo, R. A., Cho, S. K., & Wagner, W. R. (2022) · Langmuir · doi:10.1021/acs.langmuir.1c03375 · Cited by 18
Fay, M. E., Oshinowo, O. T., Iffrig, E., Fibben, K. S., Caruso, C. M., Hansen, S., Musick, J. O., Valdez, J. M., Azer, S., Mannino, R. G., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-40522-4 · Cited by 18
Mathur, T., Flanagan, J. M., & Jain, A. (2021) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10211 · Cited by 18
Self-citationCatalysts for single-wall carbon nanotube synthesis—From surface growth to bulk preparation
Zhao, X., Zhang, S., Zhu, Z., Zhang, J., Wei, F., & Li, Y. (2017) · MRS Bulletin · doi:10.1557/mrs.2017.240 · Cited by 17
Mohammad, A. M., & Al-Allawi, N. A. S. (2018) · Journal of Cardiovascular Pharmacology · doi:10.1097/fjc.0000000000000577 · Cited by 17
Rapid Detection and Inhibition of SARS‐CoV‐2‐Spike Mutation‐Mediated Microthrombosis
Satta, S., Lai, A. C., Cavallero, S., Williamson, C., Chen, J., Blázquez‐Medela, A. M., Roustaei, M., Dillon, B. J., Ashammakhi, N. A., Carlo, D. D., et al. (2021) · Advanced Science · doi:10.1002/advs.202103266 · Cited by 17
Zhang, Y., Jiang, F., Chen, Y., & Ju, L. A. (2022) · Frontiers in Pharmacology · doi:10.3389/fphar.2021.779753 · Cited by 17
Hydration Mechanism in Blood-Compatible Polymers Undergoing Phase Separation
Murakami, D., Yamazoe, K., Nishimura, S., Kurahashi, N., Ueda, T., Miyawaki, J., Ikemoto, Y., Tanaka, M., & Harada, Y. (2022) · Langmuir · doi:10.1021/acs.langmuir.1c02672 · Cited by 17
Building Blood Vessel Chips with Enhanced Physiological Relevance
Mu, X., Gerhard‐Herman, M. D., & Zhang, Y. S. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202201778 · Cited by 16
A planar surface acoustic wave micropump for closed-loop microfluidics
Rimša, R., Smith, A., Wälti, C., & Wood, C. D. (2017) · Applied Physics Letters · doi:10.1063/1.5007701 · Cited by 16
Lee, H., Na, W., Lee, B. K., Lim, C.-S., & Shin, S. (2018) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-189416 · Cited by 16
“Furthermore, pathological shear conditions were obtained by mimicking the stenotic vessels, using a specific microchannel dimension [78, 79] and rotational shear flow [63, 80].”
Bot, V. A., Shakeri, A., Weitz, J. I., & Didar, T. F. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202205078 · Cited by 16
Hemostatic Thrombus Formation in Flowing Blood
Brass, L. F., Tomaiuolo, M., Welsh, J. D., Poventud‐Fuentes, I., Zhu, L., Diamond, S. L., & Stalker, T. J. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-813456-6.00020-5 · Cited by 15
Pinheiro, E. A., Magdy, T., & Burridge, P. W. (2020) · Journal of Cardiovascular Translational Research · doi:10.1007/s12265-020-09962-x · Cited by 15
“In the context of bleeding disorders, microfluidic systems successfully recapitulate the clotting dysfunction and propensity towards bleeding, suggesting that these systems are useful for the evaluation of both thrombosis and hemorrhage [109].”
BackgroundHeart-on-a-chip and vasculature-on-a-chip platforms as models of cardiovascular disease
Khosravi, R., & Radisic, M. (2026) · Nature Reviews Cardiology · doi:10.1038/s41569-026-01255-1 · Cited by 18
“To address these limitations, a microfluidic device was developed, whereby infused flow splits into 12 smaller parallel microchannels before converging, creating regions of sudden fluid acceleration (pre-stenosis), uniform shear stress and sudden deceleration (post-stenosis) 104 (Fig.”
Shayor, A. A., Kabir, M. E., Rifath, M. S. A., Rashid, A. B., & Oh, K. W. (2024) · Sensors · doi:10.3390/s24185872 · Cited by 14
Understanding stenosis-induced platelet aggregation on a chip by high-speed optical imaging
Deng, Y., Duque, J. A., Su, C., Zhou, Y., Nishikawa, M., Xiao, T., Yatomi, Y., Hou, H. W., & Goda, K. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.131318 · Cited by 14
Monitoring circulating platelet activity to predict cancer-associated thrombosis
Li, B., Lu, Z., Yang, Z., Zhang, X., Wang, M., Chu, T., Wang, P., Qi, F., Anderson, G. J., Jiang, E., et al. (2023) · Cell Reports Methods · doi:10.1016/j.crmeth.2023.100513 · Cited by 14
Xu, Y., Deng, P., Yu, G., Ke, X., Lin, Y., Shu, X., Xie, Y., Zhang, S., Nie, R., & Wu, Z. (2021) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2021.130085 · Cited by 14
Microfluidics in coagulation monitoring devices: a mini review
Harris, L. F., & Killard, A. J. (2018) · Analytical Methods · doi:10.1039/c8ay01230j · Cited by 14
Metadata
- Authors
- Jain, A., Graveline, A., Waterhouse, A., Vernet, A., Flaumenhaft, R., & Ingber, D. E.
- Affiliations
- Boston Children's Hospital (US)
- Harvard University (US)
- Beth Israel Deaconess Medical Center (US)
- Corresponding author
- Ingber, Donald E.
- ORCID
- Venue
- Nature Communications
- Published
- 2016-01-06
- Volume
- 7
- Issue
- 1
- Pages
- 10176-10176
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC4729824
- OpenAlex
- W2343360984
- Cited by
- 182
- References
- 47
- Citations by year
- 2026: 8 · 2025: 16 · 2024: 20 · 2023: 18 · 2022: 12 · 2021: 14 · 2020: 28 · 2019: 22 · 2018: 15 · 2017: 18 · 2016: 11
- FWCI
- 19.66
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Digital Access to Scholarship at Harvard (DASH) (Harvard University) (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Science Foundation (ECS- 03-35765, 0335765)
- Harvard University (ECS-0335765)
- National Institutes of Health (ECS-0335765)
- Defense Advanced Research Projects Agency (N66001‐11‐1‐4180, HR0011, HR0011-13-C-0025)
- Hansjörg Wyss Institute for Biologically Inspired Engineering, Harvard University
- National Heart, Lung, and Blood Institute (R01HL125275, R01HL112809, T32HL007917)
- Topics
- Health Sciences › Medicine › Hematology › Blood properties and coagulation
- Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
- Health Sciences › Medicine › Hematology › Platelet Disorders and Treatments
- Keywords
- platelet function, microfluidics, shear gradient, thrombus formation, coagulation, extracorporeal circuit, anticoagulation, heparin, endotoxemia, coagulopathy, personalized diagnosis
- MeSH terms
- Abciximab, Animals, Antibodies, Monoclonal, Blood Coagulation Tests, Blood Platelets, Female, Hemostasis, Humans, Immunoglobulin Fab Fragments, Platelet Aggregation, Platelet Aggregation Inhibitors, Platelet Function Tests, Swine, Point-of-Care Systems, Shear Strength, Microfluidic Analytical Techniques, Lab-On-A-Chip Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.