Three-dimensional imaging of single nanotube molecule endocytosis on plasmonic substrates
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Investigating the cellular internalization pathways of single molecules or single nano objects is important to understanding cell–matter interactions, and to applications in drug delivery and discovery. Imaging and tracking the motion of single molecules on cell plasma membranes require high spatial resolution in three dimensions. Fluorescence imaging along the axial dimension with nanometre resolution has been highly challenging, but critical to revealing displacements in transmembrane events. Here, utilizing a plasmonic ruler based on the sensitive distance dependence of near-infrared fluorescence enhancement of carbon nanotubes on a gold plasmonic substrate, we probe ~10 nm scale transmembrane displacements through changes in nanotube fluorescence intensity, enabling observations of single nanotube endocytosis in three dimensions. Cellular uptake and transmembrane displacements show clear dependences to temperature and clathrin assembly on cell membrane, suggesting that the cellular entry mechanism for a nanotube molecule is via clathrin-dependent endocytosis through the formation of clathrin-coated pits on the cell membrane. Imaging and tracking the motion of single molecules on cell plasma membranes requires high spatial resolution in three dimensions. Honget al. develop a plasmonic ruler based on the fluorescence enhancement of carbon nanotubes on a gold plasmonic substrate, allowing the observation of nanotube endocytosis in three dimensions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Structure-Assigned Optical Spectra of Single-Walled Carbon Nanotubes
Bachilo, S. M., Strano, M. S., Kittrell, C., Hauge, R. H., Smalley, R. E., & Weisman, R. B. (2002) · Science · doi:10.1126/science.1078727 · Cited by 3,078
A route to brightly fluorescent carbon nanotubes for near-infrared imaging in mice
Welsher, K., Liu, Z., Sherlock, S. P., Robinson, J. T., Chen, Z., Daranciang, D., & Dai, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.294 · Cited by 1,287
Self-citationWelsher, K., Sherlock, S. P., & Dai, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014501108 · Cited by 958
Self-citation
Cited by
Functional Nanomaterials for Phototherapies of Cancer
Cheng, L., Wang, C., Feng, L., Yang, K., & Liu, Z. (2014) · Chemical Reviews · doi:10.1021/cr400532z · Cited by 2,425
Carbon Nanomaterials for Biological Imaging and Nanomedicinal Therapy
Hong, G., Diao, S., Antaris, A. L., & Dai, H. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00008 · Cited by 1,394
Self-citationGold Nanomaterials at Work in Biomedicine
Yang, X., Yang, M., Pang, B., Vara, M., & Xia, Y. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00193 · Cited by 1,162
Through-skull fluorescence imaging of the brain in a new near-infrared window
Hong, G., Diao, S., Chang, J., Antaris, A. L., Chen, C., Zhang, B., Zhao, S., Atochin, D. N., Huang, P. L., Andreasson, K. I., et al. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.166 · Cited by 1,061
Self-citationMultifunctional in vivo vascular imaging using near-infrared II fluorescence
Hong, G., Lee, J. C., Robinson, J. T., Raaz, U., Xie, L., Huang, N. F., Cooke, J. P., & Dai, H. (2012) · Nature Medicine · doi:10.1038/nm.2995 · Cited by 995
Self-citationIn Vivo Fluorescence Imaging with Ag2S Quantum Dots in the Second Near‐Infrared Region
Hong, G., Robinson, J. T., Zhang, Y., Diao, S., Antaris, A. L., Wang, Q., & Dai, H. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201206059 · Cited by 744
Self-citationHong, G., Zou, Y., Antaris, A. L., Diao, S., Wu, D., Cheng, K., Zhang, X., Chen, C., Liu, B., He, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms5206 · Cited by 563
Self-citationDonor Engineering for NIR-II Molecular Fluorophores with Enhanced Fluorescent Performance
Yang, Q., Hu, Z., Zhu, S., Ma, R., Ma, H., Ma, Z., Wan, H., Zhu, T., Jiang, Z., Liu, W., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b10334 · Cited by 554
Self-citationRational Design of Molecular Fluorophores for Biological Imaging in the NIR‐II Window
Yang, Q., Ma, Z., Wang, H., Zhou, B., Zhu, S., Zhong, Y., Wang, J., Wan, H., Antaris, A., Ma, R., et al. (2017) · Advanced Materials · doi:10.1002/adma.201605497 · Cited by 467
Self-citationCarbon nanotubes as optical biomedical sensors
Kruss, S., Hilmer, A. J., Zhang, J., Reuel, N. F., Mu, B., & Strano, M. S. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.015 · Cited by 413
Biological imaging without autofluorescence in the second near-infrared region
Diao, S., Hong, G., Antaris, A. L., Blackburn, J. L., Cheng, K., Cheng, Z., & Dai, H. (2015) · Nano Research · doi:10.1007/s12274-015-0808-9 · Cited by 343
Self-citationTemperature: The “Ignored” Factor at the NanoBio Interface
Mahmoudi, M., Abdelmonem, A. M., Behzadi, S., Clement, J. H., Dutz, S., Ejtehadi, M. R., Hartmann, R., Kantner, K., Linne, U., Maffre, P., et al. (2013) · ACS Nano · doi:10.1021/nn305337c · Cited by 333
Guo, Z., Zhu, S., Yong, Y., Zhang, X., Dong, X., Du, J., Xie, J., Wang, Q., Gu, Z., & Zhao, Y. (2017) · Advanced Materials · doi:10.1002/adma.201704136 · Cited by 327
Imaging of Colorectal Cancers Using Activatable Nanoprobes with Second Near‐Infrared Window Emission
Xu, G., Yan, Q., Lv, X., Zhu, Y., Xin, K., Shi, B., Wang, R., Chen, J., Gao, W., Shi, P., et al. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201712528 · Cited by 314
Recent Progress in Light-Triggered Nanotheranostics for Cancer Treatment
Zhang, P., Hu, C., Ran, W., Meng, J., Yin, Q., & Li, Y. (2016) · Theranostics · doi:10.7150/thno.15217 · Cited by 211
“One possible reason for this is that the permeability of the cell membrane and endocytosis of nanoparticles is higher at 42 °C than at 37 °C [196].”
BackgroundMultifunctional Biomedical Imaging in Physiological and Pathological Conditions Using a NIR‐II Probe
Shou, K., Qu, C., Sun, Y., Chen, H., Chen, S., Zhang, L., Xu, H., Hong, X., Yu, A., & Cheng, Z. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201700995 · Cited by 209
Cell Membrane Proteins Modulate the Carbon Nanotube Optical Bandgap via Surface Charge Accumulation
Roxbury, D., Jena, P. V., Shamay, Y., Horoszko, C. P., & Heller, D. A. (2016) · ACS Nano · doi:10.1021/acsnano.5b05438 · Cited by 74
Metadata
- Authors
- Hong, G., Wu, J. Z., Robinson, J. T., Wang, H., Zhang, B., & Dai, H.
- Venue
- Nature Communications
- Published
- 2012-02-28
- Volume
- 3
- Issue
- 1
- Pages
- 700-700
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2035040170
- Cited by
- 88
- References
- 3
- FWCI
- 4.57
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.