Graphene-based carbon-layered electrode array technology for neural imaging and optogenetic applications
Open accessThe DOI matches its Crossref record; 50 of the 51 references it cites were found in a registry or an index.
Abstract
Neural micro-electrode arrays that are transparent over a broad wavelength spectrum from ultraviolet to infrared could allow for simultaneous electrophysiology and optical imaging, as well as optogenetic modulation of the underlying brain tissue. The long-term biocompatibility and reliability of neural micro-electrodes also require their mechanical flexibility and compliance with soft tissues. Here we present a graphene-based, carbon-layered electrode array (CLEAR) device, which can be implanted on the brain surface in rodents for high-resolution neurophysiological recording. We characterize optical transparency of the device at >90% transmission over the ultraviolet to infrared spectrum and demonstrate its utility through optical interface experiments that use this broad spectrum transparency. These include optogenetic activation of focal cortical areas directly beneath electrodes, in vivo imaging of the cortical vasculature via fluorescence microscopy and 3D optical coherence tomography. This study demonstrates an array of interfacing abilities of the CLEAR device and its utility for neural applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures






Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Recent advancements in soft and nanomaterials have opened up more options for flexible recording electrodes, like conductive polymers (e.g., PEDOT)[302,312] and nanomaterial composites (metal-based, CNT, graphene)[313–317].”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [316]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Geim, A. K., & Novoselov, K. S. (2007) · Nature Materials · doi:10.1038/nmat1849 · Cited by 39,979
Measurement of the Elastic Properties and Intrinsic Strength of Monolayer Graphene
Lee, C., Wei, X., Kysar, J. W., & Hone, J. (2008) · Science · doi:10.1126/science.1157996 · Cited by 20,847
Grätzel, M. (2001) · Nature · doi:10.1038/35104607 · Cited by 12,687
Large-scale pattern growth of graphene films for stretchable transparent electrodes
Kim, K. S., Zhao, Y., Jang, H., Lee, S. Y., Kim, J. M., Kim, K. S., Ahn, J.-H., Kim, P., Choi, J.-Y., & Hong, B. H. (2009) · Nature · doi:10.1038/nature07719 · Cited by 10,452
Roll-to-roll production of 30-inch graphene films for transparent electrodes
Bae, S., Kim, H., Lee, Y., Xu, X., Park, J.-S., Zheng, Y., Balakrishnan, J., Lei, T., Ri Kim, H., Song, Y. I., et al. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.132 · Cited by 8,136
Graphene photonics and optoelectronics
Bonaccorso, F., Sun, Z., Hasan, T., & Ferrari, A. C. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.186 · Cited by 7,726
Transfer of Large-Area Graphene Films for High-Performance Transparent Conductive Electrodes
Li, X., Zhu, Y., Cai, W., Borysiak, M., Han, B., Chen, D., Piner, R. D., Colombo, L., & Ruoff, R. S. (2009) · Nano Letters · doi:10.1021/nl902623y · Cited by 3,081
Mechanically Strong, Electrically Conductive, and Biocompatible Graphene Paper
Chen, H., Müller, M. B., Gilmore, K. J., Wallace, G. G., & Li, D. (2008) · Advanced Materials · doi:10.1002/adma.200800757 · Cited by 2,040
The development and application of optogenetics
Fenno, L., Yizhar, O., & Deisseroth, K. (2011) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-061010-113817 · Cited by 1,822
A brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136
Transparent and conducting ITO films: new developments and applications
Granqvist, C. G., & Hultåker, A. (2002) · Thin Solid Films · doi:10.1016/s0040-6090(02)00163-3 · Cited by 991
In vivo human retinal imaging by Fourier domain optical coherence tomography
Wojtkowski, M., Leitgeb, R., Kowalczyk, A., Bajraszewski, T., & Fercher, A. F. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1482379 · Cited by 913
Flexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
Self-citationThree dimensional optical angiography
Wang, R. K., Jacques, S. L., Ma, Z., Hurst, S., Hanson, S. R., & Gruber, A. (2007) · Optics Express · doi:10.1364/oe.15.004083 · Cited by 627
Self-citationIzatt, J. A., Kulkarni, M. D., Yazdanfar, S., Barton, J. K., & Welch, A. J. (1997) · Optics Letters · doi:10.1364/ol.22.001439 · Cited by 609
Makita, S., Hong, Y., Yamanari, M., Yatagai, T., & Yasuno, Y. (2006) · Optics Express · doi:10.1364/oe.14.007821 · Cited by 594
Cardin, J. A., Carlén, M., Meletis, K., Knoblich, U., Zhang, F., Deisseroth, K., Tsai, L.-H., & Moore, C. I. (2010) · Nature Protocols · doi:10.1038/nprot.2009.228 · Cited by 547
Optical Doppler tomographic imaging of fluid flow velocity in highly scattering media
Chen, Z., Milner, T. E., Dave, D., & Nelson, J. S. (1997) · Optics Letters · doi:10.1364/ol.22.000064 · Cited by 443
Li, N., Zhang, X., Song, Q., Su, R., Zhang, Q., Kong, T., Liu, L., Jin, G., Tang, M., & Cheng, G. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.08.065 · Cited by 428
Complex impedance spectroscopy for monitoring tissue responses to inserted neural implants
Williams, J. C., Hippensteel, J. A., Dilgen, J., Shain, W., & Kipke, D. R. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/007 · Cited by 399
Self-citationA MEMS-based flexible multichannel ECoG-electrode array
Rubehn, B., Bosman, C., Oostenveld, R., Fries, P., & Stieglitz, T. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/036003 · Cited by 387
Minami, T. (2008) · Thin Solid Films · doi:10.1016/j.tsf.2007.03.082 · Cited by 325
Gross, G. W. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326402 · Cited by 324
Optogenetic tools for analyzing the neural circuits of behavior
Bernstein, J. G., & Boyden, E. S. (2011) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2011.10.003 · Cited by 270
Real-time multi-channel stimulus artifact suppression by local curve fitting
Wagenaar, D. A., & Potter, S. M. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00149-8 · Cited by 227
Transparent and conductive electrodes based on unpatterned, thin metal films
O’Connor, B., Haughn, C., An, K.-H., Pipe, K. P., & Shtein, M. (2008) · Applied Physics Letters · doi:10.1063/1.3028046 · Cited by 223
Doppler optical micro-angiography for volumetric imaging of vascular perfusion in vivo
Wang, R. K., & An, L. (2009) · Optics Express · doi:10.1364/oe.17.008926 · Cited by 220
A 32-site neural recording probe fabricated by DRIE of SOI substrates
Norlin, P., Kindlundh, M., Mouroux, A., Yoshida, K., & Hofmann, U. G. (2002) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/12/4/312 · Cited by 184
Kwon, K. Y., Sirowatka, B., Weber, A., & Li, W. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2282318 · Cited by 166
Guillén, C., & Herrero, J. (2005) · Thin Solid Films · doi:10.1016/j.tsf.2004.11.040 · Cited by 165
ECoG factors underlying multimodal control of a brain-computer interface
Wilson, J. A., Felton, E. A., Garell, P. C., Schalk, G., & Williams, J. C. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875570 · Cited by 163
Self-citationRapid volumetric angiography of cortical microvasculature with optical coherence tomography
Srinivasan, V. J., Jiang, J. Y., Yaseen, M. A., Radhakrishnan, H., Wu, W., Barry, S., Cable, A. E., & Boas, D. A. (2010) · Optics Letters · doi:10.1364/ol.35.000043 · Cited by 159
Wafer bonding using microwave heating of parylene intermediate layers
Noh, H. “., Moon, K., Cannon, A. H., Hesketh, P. J., & Wong, C. P. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/4/025 · Cited by 158
Otto, K. J., Johnson, M. D., & Kipke, D. R. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862530 · Cited by 134
Performance of flexible polymeric light-emitting diodes under bending conditions
Päetzold, R., Heuser, K., Henseler, D., Roeger, S., Wittmann, G., & Winnacker, A. (2003) · Applied Physics Letters · doi:10.1063/1.1574400 · Cited by 116
In Vivo Application of Optogenetics for Neural Circuit Analysis
Han, X. (2012) · ACS Chemical Neuroscience · doi:10.1021/cn300065j · Cited by 107
Henle, C., Raab, M., Cordeiro, J. G., Doostkam, S., Schulze‐Bonhage, A., Stieglitz, T., & Rickert, J. (2010) · Biomedical Microdevices · doi:10.1007/s10544-010-9471-9 · Cited by 104
A Micro-Electrocorticography Platform and Deployment Strategies for Chronic BCI Applications
Thongpang, S., Richner, T. J., Brodnick, S. K., Schendel, A. A., Kim, J., Wilson, J. A., Hippensteel, J. A., Krugner-Higby, L. A., Moran, D., Ahmed, A. S., et al. (2011) · Clinical EEG and Neuroscience · doi:10.1177/155005941104200412 · Cited by 82
Self-citationOptogenetics in the nonhuman primate
Han, X. (2012) · Progress in brain research · doi:10.1016/b978-0-444-59426-6.00011-2 · Cited by 81
The effect of micro-ECoG substrate footprint on the meningeal tissue response
Schendel, A. A., Nonte, M. W., Vokoun, C. R., Richner, T. J., Brodnick, S. K., Atry, F., Frye, S., Bostrom, P., Pashaie, R., Thongpang, S., et al. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/4/046011 · Cited by 79
Self-citationA transparent μECoG array for simultaneous recording and optogenetic stimulation
Ledochowitsch, P., Olivero, E., Blanche, T., & Maharbiz, M. M. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090808 · Cited by 69
Schendel, A. A., Thongpang, S., Brodnick, S. K., Richner, T. J., Lindevig, B. D. B., Krugner-Higby, L. A., & Williams, J. C. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.06.001 · Cited by 63
Self-citationOptogenetic micro-electrocorticography for modulating and localizing cerebral cortex activity
Richner, T. J., Thongpang, S., Brodnick, S. K., Schendel, A. A., Falk, R., Krugner-Higby, L. A., Pashaie, R., & Williams, J. C. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016010 · Cited by 63
Self-citationHistological evaluation of polyesterimide-insulated gold wires in brain
Yuen, T. G. H., & Agnew, W. F. (1995) · Biomaterials · doi:10.1016/0142-9612(95)93121-s · Cited by 54
Ion-beam-deposited ultrathin transparent metal contacts
Klauk, H., Huang, J.-R., Nichols, J. A., & Jackson, T. N. (2000) · Thin Solid Films · doi:10.1016/s0040-6090(00)00728-8 · Cited by 43
Dawn of the evolution of photoelectrochemistry
Honda, K. (2004) · Journal of Photochemistry and Photobiology A Chemistry · doi:10.1016/j.jphotochem.2004.04.027 · Cited by 36
Opto-μECoG array: Transparent μECoG electrode array and integrated LEDs for optogenetics
Kwon, K. Y., Sirowatka, B., Li, W., & Weber, A. J. (2012) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2012.6418471 · Cited by 17
Voltage Biasing, Cyclic Voltammetry, & Electrical Impedance Spectroscopy for Neural Interfaces
Wilks, S. J., Richner, T. J., Brodnick, S. K., Kipke, D. R., Williams, J. C., & Otto, K. J. (2012) · Journal of Visualized Experiments · doi:10.3791/3566 · Cited by 14
Self-citationHybrid laser and reactive ion etching of Parylene-C for deinsulation of a Utah electrode array
Yoo, J.-M., Song, J.-I., Tathireddy, P., Solzbacher, F., & Rieth, L. W. (2012) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/22/10/105036 · Cited by 12
Cited by
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
A review on mechanics and mechanical properties of 2D materials—Graphene and beyond
Akinwande, D., Brennan, C. J., Bunch, J. S., Egberts, P., Felts, J. R., Gao, H., Huang, R., Kim, J.-S., Li, T., Li, Y., et al. (2017) · Extreme Mechanics Letters · doi:10.1016/j.eml.2017.01.008 · Cited by 1,342
Electronic dura mater for long-term multimodal neural interfaces
Minev, I. R., Musienko, P., Hirsch, A., Barraud, Q., Wenger, N., Moraud, E. M., Gandar, J., Capogrosso, M., Milekovic, T., Asboth, L., et al. (2015) · Science · doi:10.1126/science.1260318 · Cited by 1,082
Metadata
- Authors
- Park, D.-W., Schendel, A. A., Mikael, S., Brodnick, S. K., Richner, T. J., Ness, J. P., Hayat, M. R., Atry, F., Frye, S. T., Pashaie, R., Thongpang, S., Ma, Z., & Williams, J. C.
- Affiliations
- University of Wisconsin–Madison (US)
- University of Wisconsin–Milwaukee (US)
- Mahidol University (TH)
- Corresponding author
- Ma, Zhenqiang
- Williams, Justin C.
- ORCID
- Venue
- Nature Communications
- Published
- 2014-10-20
- Volume
- 5
- Issue
- 1
- Pages
- 5258-5258
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC4218963
- OpenAlex
- W2044169471
- Semantic Scholar
- c6809f059fc4af9861de1575d14b18959185a6ae
- Cited by
- 565
- References
- 51
- Citations by year
- 2026: 18 · 2025: 24 · 2024: 41 · 2023: 55 · 2022: 53 · 2021: 63 · 2020: 57 · 2019: 53 · 2018: 99 · 2017: 51 · 2016: 35 · 2015: 16
- FWCI
- 15.53
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Funders
- Henan Institute of Science and Technology
- National Institutes of Health
- Defense Advanced Research Projects Agency (N66001-11-1-4013, N66001-12-C-4025)
- Advanced Research Projects Agency
- Office of Naval Research (N000140910803, N00014)
- National Institute of Biomedical Imaging and Bioengineering (T32EB011434, R01EB000856, R01EB009103)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- graphene, optogenetics, neuroimaging, optical transparency, fluorescence microscopy, optical coherence tomography, electrophysiology, biocompatibility, flexible electrodes
- MeSH terms
- Animals, Biocompatible Materials, Carbon, Electrodes, Equipment Design, Female, Graphite, Male, Microscopy, Fluorescence, Silicon, Artifacts, Rats, Sprague-Dawley, Imaging, Three-Dimensional, Tomography, Optical Coherence, Mice, Rats, Optics and Photonics, Neuroimaging, Optogenetics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.