The DOI matches its Crossref record; 52 of the 53 references it cites were found in a registry or an index.
Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Open accessAbstract
The pursuit of better atomic clocks has advanced many research areas, providing better quantum state control, new insights in quantum science, tighter limits on fundamental constant variation and improved tests of relativity. The record for the best stability and accuracy is currently held by optical lattice clocks. Here we take an important step towards realizing the full potential of a many-particle clock with a state-of-the-art stable laser. Our 87 Sr optical lattice clock now achieves fractional stability of 2.2 × 10−16 at 1 s. With this improved stability, we perform a new accuracy evaluation of our clock, reducing many systematic uncertainties that limited our previous measurements, such as those in the lattice ac Stark shift, the atoms’ thermal environment and the atomic response to room-temperature blackbody radiation. Our combined measurements have reduced the total uncertainty of the JILA Sr clock to 2.1 × 10−18 in fractional frequency units.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



![Figure 4 The measurement of the 3D1 decay rate. (a) The electronic states used for the decay rate measurement. First, we drive the clock transition and then we use a 200-ns laser pulse to drive the 2.6 μm 3P0→3D1 transition. The 3D1 state decays into the 3P manifold with the branching ratios depicted in the panel. Photons from 3P1→1S0 are collected by a photomultiplier tube (PMT). (b) The sum of photon counts for eight million decay events (black dots), fit with the function y(t)=y0+A{exp[–(t–t0)/τ3P1]–exp[–(t–t0)/τ3D1]} (red curve). Data when the pulse is on is excluded to ensure an unbiased fit. The inset is the error ellipse for the fits of τ3D1 and τ3P1. (c) Lifetime versus atom number. Comparing a constant model of this data with a model that is linear in density (the first-order correction for a density-dependent effect) using an F-test, we find no statistically significant lifetime dependence on density. Error bars represent 1σ fit uncertainties (see Methods). The blue band is the ±1σ confidence interval in the weighted mean of these data.](https://figures.cochat.ai/paper-figures/f28c9fdf8f634e8f945b4ec015e03ac3/systematic-evaluation-of-an-atomic-clock-at-2-1018-total-uncertainty-figure-4.jpg)


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Following the lattice light shift model in Ref. [37], we describe firstand higher-order lattice light shifts in a combined model.”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [37]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“More recently, an accuracy of 2 . 1 × 10 -18 (JILA, Nicholson et al. 2015) has been obtained, equivalent to geopotential differences of 0 . 2 m 2 s -2 , or 2 cm on the geoid.”
From Determination of a high spatial resolution geopotential model using atomic clock comparisons (2017) · cites this paper as Nicholson et al. 2015
The cited source says what the claim attributes to it.
In the citing paper
“In comparison to [24], the uncertainty of Sr2 was reduced owing to an extended investigation of the cold-collision shift and a combined evaluation of the lattice light shifts of different orders, using the model from Ref. [37].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [37]
The cited source says what the claim attributes to it.
In the citing paper
“with the current generation of optical atomic clocks reporting fractional performance below the 10 -17 level 1-5 .”
From Atomic clock performance enabling geodesy below the centimetre level (2018) · cites this paper as [2]
The cited source says what the claim attributes to it.
In the citing paper
“They reach systematic uncertainties of a few 10 -18 , which can be resolved after a mere few hours of measurement with optical lattice clocks based on trapped neutral atoms [2][3][4][5][6].”
From Test of Special Relativity Using a Fiber Network of Optical Clocks (2017) · cites this paper as [4]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences.
C., E. L., & Bevington, P. R. (1972) · Journal of the American Statistical Association · doi:10.2307/2284752 · Cited by 3,534
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Self-citationFrequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Kómár, P., Kessler, E. M., Bishof, M., Jiang, L., Sørensen, A. S., Ye, J., & Lukin, M. D. (2014) · Nature Physics · doi:10.1038/nphys3000 · Cited by 768
Self-citationA sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Kessler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 754
Self-citationSpectroscopy Using Quantum Logic
Schmidt, P. O., Rosenband, T., Langer, C., Itano, W. M., Bergquist, J. C., & Wineland, D. J. (2005) · Science · doi:10.1126/science.1114375 · Cited by 643
Nobel Lecture: Controlling photons in a box and exploring the quantum to classical boundary
Haroche, S. (2013) · Reviews of Modern Physics · doi:10.1103/revmodphys.85.1083 · Cited by 633
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Research works printed but not linked: 3
- Dick, J. G. In Proc 19th Precise Time Time Interval Meet. 133–147 (1987).
- Kimble, H. J. In Proc. XIV Int. Conf. Laser Spectrosc. 80–89 (1999).
- Dick, G., Prestage, J., Greenhall, C. & Maleki, L. In Proc. 22nd Precise Time Time Interval Meet. 487–508 (1990).
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationQuantum metrology with nonclassical states of atomic ensembles
Pezzè, L., Smerzi, A., Oberthaler, M. K., Schmied, R., & Treutlein, P. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.035005 · Cited by 1,682
“It also allows for faster evaluation of systematic errors, which in turn can improve the accuracy (Nicholson et al., 2015).”
BackgroundSearch for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560
Self-citationAtomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
Metadata
- Authors
- Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., Tew, W. L., & Ye, J.
- Affiliations
- National Institute of Standards and Technology (US)
- Centre for Quantum Technologies (SG)
- Corresponding author
- Ye, J.
- ORCID
- Venue
- Nature Communications
- Published
- 2015-04-21
- Volume
- 6
- Issue
- 1
- Pages
- 6896-6896
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC4411304
- OpenAlex
- W2073958075
- Cited by
- 780
- References
- 53
- Citations by year
- 2026: 33 · 2025: 48 · 2024: 63 · 2023: 61 · 2022: 60 · 2021: 59 · 2020: 68 · 2019: 84 · 2018: 86 · 2017: 81 · 2016: 102 · 2015: 35
- FWCI
- 51.26
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by)
- arXiv (Cornell University) (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- National University of Singapore (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- arXiv (Cornell University)
- Funders
- National Science Foundation
- National Institute of Standards and Technology
- Advanced Research Projects Agency
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Keywords
- optical lattice clock, strontium-87, systematic uncertainties, fractional frequency stability, AC Stark shift, blackbody radiation shift, thermal environment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.