Systematic evaluation of an atomic clock at 2 × 10−18 total uncertainty
Open accessThe DOI matches its Crossref record; 52 of the 53 references it cites were found in a registry or an index.
Abstract
The pursuit of better atomic clocks has advanced many research areas, providing better quantum state control, new insights in quantum science, tighter limits on fundamental constant variation and improved tests of relativity. The record for the best stability and accuracy is currently held by optical lattice clocks. Here we take an important step towards realizing the full potential of a many-particle clock with a state-of-the-art stable laser. Our 87 Sr optical lattice clock now achieves fractional stability of 2.2 × 10−16 at 1 s. With this improved stability, we perform a new accuracy evaluation of our clock, reducing many systematic uncertainties that limited our previous measurements, such as those in the lattice ac Stark shift, the atoms’ thermal environment and the atomic response to room-temperature blackbody radiation. Our combined measurements have reduced the total uncertainty of the JILA Sr clock to 2.1 × 10−18 in fractional frequency units.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



![Figure 4 The measurement of the 3D1 decay rate. (a) The electronic states used for the decay rate measurement. First, we drive the clock transition and then we use a 200-ns laser pulse to drive the 2.6 μm 3P0→3D1 transition. The 3D1 state decays into the 3P manifold with the branching ratios depicted in the panel. Photons from 3P1→1S0 are collected by a photomultiplier tube (PMT). (b) The sum of photon counts for eight million decay events (black dots), fit with the function y(t)=y0+A{exp[–(t–t0)/τ3P1]–exp[–(t–t0)/τ3D1]} (red curve). Data when the pulse is on is excluded to ensure an unbiased fit. The inset is the error ellipse for the fits of τ3D1 and τ3P1. (c) Lifetime versus atom number. Comparing a constant model of this data with a model that is linear in density (the first-order correction for a density-dependent effect) using an F-test, we find no statistically significant lifetime dependence on density. Error bars represent 1σ fit uncertainties (see Methods). The blue band is the ±1σ confidence interval in the weighted mean of these data.](https://figures.cochat.ai/paper-figures/f28c9fdf8f634e8f945b4ec015e03ac3/systematic-evaluation-of-an-atomic-clock-at-2-1018-total-uncertainty-figure-4.jpg)


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Following the lattice light shift model in Ref. [37], we describe firstand higher-order lattice light shifts in a combined model.”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [37]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“More recently, an accuracy of 2 . 1 × 10 -18 (JILA, Nicholson et al. 2015) has been obtained, equivalent to geopotential differences of 0 . 2 m 2 s -2 , or 2 cm on the geoid.”
From Determination of a high spatial resolution geopotential model using atomic clock comparisons (2017) · cites this paper as Nicholson et al. 2015
The cited source says what the claim attributes to it.
In the citing paper
“In comparison to [24], the uncertainty of Sr2 was reduced owing to an extended investigation of the cold-collision shift and a combined evaluation of the lattice light shifts of different orders, using the model from Ref. [37].”
From Long-distance chronometric leveling with a portable optical clock (2024) · cites this paper as [37]
The cited source says what the claim attributes to it.
In the citing paper
“with the current generation of optical atomic clocks reporting fractional performance below the 10 -17 level 1-5 .”
From Atomic clock performance enabling geodesy below the centimetre level (2018) · cites this paper as [2]
The cited source says what the claim attributes to it.
In the citing paper
“They reach systematic uncertainties of a few 10 -18 , which can be resolved after a mere few hours of measurement with optical lattice clocks based on trapped neutral atoms [2][3][4][5][6].”
From Test of Special Relativity Using a Fiber Network of Optical Clocks (2017) · cites this paper as [4]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences.
C., E. L., & Bevington, P. R. (1972) · Journal of the American Statistical Association · doi:10.2307/2284752 · Cited by 3,534
An optical lattice clock with accuracy and stability at the 10−18 level
Bloom, B. J., Nicholson, T. L., Williams, J. R., Campbell, S. L., Bishof, M., Zhang, X., Zhang, W., Bromley, S. L., & Ye, J. (2014) · Nature · doi:10.1038/nature12941 · Cited by 1,073
Self-citationFrequency Comparison of Two High-Accuracy Al + Optical Clocks
Chou, C., Hume, D., Koelemeij, J., Wineland, D., & Rosenband, T. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070802 · Cited by 903
An Atomic Clock with 10 –18 Instability
Hinkley, N., Sherman, J. A., Phillips, N. B., Schioppo, M., Lemke, N. D., Beloy, K., Pizzocaro, M., Oates, C. W., & Ludlow, A. D. (2013) · Science · doi:10.1126/science.1240420 · Cited by 817
Kómár, P., Kessler, E. M., Bishof, M., Jiang, L., Sørensen, A. S., Ye, J., & Lukin, M. D. (2014) · Nature Physics · doi:10.1038/nphys3000 · Cited by 768
Self-citationA sub-40-mHz-linewidth laser based on a silicon single-crystal optical cavity
Kessler, T., Hagemann, C., Grebing, C., Legero, T., Sterr, U., Riehle, F., Martin, M. J., Chen, L., & Ye, J. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.217 · Cited by 754
Self-citationSpectroscopy Using Quantum Logic
Schmidt, P. O., Rosenband, T., Langer, C., Itano, W. M., Bergquist, J. C., & Wineland, D. J. (2005) · Science · doi:10.1126/science.1114375 · Cited by 643
Nobel Lecture: Controlling photons in a box and exploring the quantum to classical boundary
Haroche, S. (2013) · Reviews of Modern Physics · doi:10.1103/revmodphys.85.1083 · Cited by 633
Cryogenic optical lattice clocks
Ushijima, I., Takamoto, M., Das, M., Ohkubo, T., & Katori, H. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.5 · Cited by 627
Quantum projection noise: Population fluctuations in two-level systems
Itano, W. M., Bergquist, J. C., Bollinger, J. J., Gilligan, J. M., Heinzen, D. J., Moore, F. L., Raizen, M. G., & Wineland, D. J. (1993) · Physical Review A · doi:10.1103/physreva.47.3554 · Cited by 613
Research works printed but not linked: 3
- Dick, J. G. In Proc 19th Precise Time Time Interval Meet. 133–147 (1987).
- Kimble, H. J. In Proc. XIV Int. Conf. Laser Spectrosc. 80–89 (1999).
- Dick, G., Prestage, J., Greenhall, C. & Maleki, L. In Proc. 22nd Precise Time Time Interval Meet. 487–508 (1990).
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
Self-citationQuantum metrology with nonclassical states of atomic ensembles
Pezzè, L., Smerzi, A., Oberthaler, M. K., Schmied, R., & Treutlein, P. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.035005 · Cited by 1,682
“It also allows for faster evaluation of systematic errors, which in turn can improve the accuracy (Nicholson et al., 2015).”
BackgroundSearch for new physics with atoms and molecules
Safronova, M. S., Budker, D., DeMille, D., Kimball, D. F. J., Derevianko, A., & Clark, C. W. (2018) · Reviews of Modern Physics · doi:10.1103/revmodphys.90.025008 · Cited by 1,560
Self-citationAtomic clock performance enabling geodesy below the centimetre level
McGrew, W. F., Zhang, X., Fasano, R. J., Schäffer, S. A., Beloy, K., Nicolodi, D., Brown, R. C., Hinkley, N., Milani, G., Schioppo, M., et al. (2018) · Nature · doi:10.1038/s41586-018-0738-2 · Cited by 727
Optical frequency combs: Coherently uniting the electromagnetic spectrum
Diddams, S. A., Vahala, K., & Udem, T. (2020) · Science · doi:10.1126/science.aay3676 · Cited by 714
(2019) · doi:10.1103/physrevlett.123.033201 · Cited by 711
Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty
Huntemann, N., Sanner, C., Lipphardt, B., Tamm, C., & Peik, E. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.063001 · Cited by 677
1.5 μm Lasers with Sub-10 mHz Linewidth
Matei, D. G., Legero, T., Häfner, S., Grebing, C., Weyrich, R., Zhang, W., Sonderhouse, L., Robinson, J. M., Ye, J., Riehle, F., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.263202 · Cited by 584
Self-citationTest of general relativity by a pair of transportable optical lattice clocks
Takamoto, M., Ushijima, I., Ohmae, N., Yahagi, T., Kokado, K., Shinkai, H., & Katori, H. (2020) · Nature Photonics · doi:10.1038/s41566-020-0619-8 · Cited by 507
Geodesy and metrology with a transportable optical clock
Grotti, J., Koller, S., Vogt, S., Häfner, S., Sterr, U., Lisdat, C., Denker, H., Voigt, C., Timmen, L., Rolland, A., et al. (2018) · Nature Physics · doi:10.1038/s41567-017-0042-3 · Cited by 495
Demonstration of 4.8 × 10−17 stability at 1 s for two independent optical clocks
Oelker, E., Hutson, R. B., Kennedy, C. J., Sonderhouse, L., Bothwell, T., Goban, A., Kedar, D., Sanner, C., Robinson, J. M., Marti, G. E., et al. (2019) · Nature Photonics · doi:10.1038/s41566-019-0493-4 · Cited by 475
Self-citationA clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460
“Optical clocks are – due to their orders of magnitude better precision (1) and accuracy (2,3,4) than their microwave counterparts realizing the definition of the SI second – new sensors with highest resolving power to, e.”
BackgroundResolving the gravitational redshift across a millimetre-scale atomic sample
Bothwell, T., Kennedy, C. J., Aeppli, A., Kedar, D., Robinson, J. M., Oelker, E., Staron, A., & Ye, J. (2022) · Nature · doi:10.1038/s41586-021-04349-7 · Cited by 449
Self-citationGravitational wave detection with optical lattice atomic clocks
Kolkowitz, S., Pikovski, I., Langellier, N., Lukin, M. D., Walsworth, R. L., & Ye, J. (2016) · Physical Review D · doi:10.1103/physrevd.94.124043 · Cited by 396
Self-citationFrequency ratio measurements at 18-digit accuracy using an optical clock network
Boulder Atomic Clock Optical Network (BACON) Collaboration*, Beloy, K., Bodine, M. I., Bothwell, T., Brewer, S. M., Bromley, S. L., Chen, J.-S., Deschênes, J.-D., Diddams, S. A., Fasano, R. J., et al. (2021) · Nature · doi:10.1038/s41586-021-03253-4 · Cited by 390
“This work employed the JILA SrI clock system instead of the SrII sys-tem 16 .”
Self-citationUltrastable optical clock with two cold-atom ensembles
Schioppo, M., Brown, R. C., McGrew, W. F., Hinkley, N., Fasano, R. J., Beloy, K., Yoon, T. H., Milani, G., Nicolodi, D., Sherman, J. A., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.231 · Cited by 385
A Fermi-degenerate three-dimensional optical lattice clock
Campbell, S. L., Hutson, R. B., Marti, G. E., Goban, A., Darkwah Oppong, N., McNally, R. L., Sonderhouse, L., Robinson, J. M., Zhang, W., Bloom, B. J., et al. (2017) · Science · doi:10.1126/science.aam5538 · Cited by 384
“For a given lattice laser frequency, we measure the differential ac Stark shift using four interleaved digital servos that lock the clock laser frequency to the atomic resonance for alternating high and low lattice intensities and mF = ±9/2 spin states [23, 121, 56].”
BackgroundMethodInfluentialSelf-citationJILA SrI optical lattice clock with uncertainty of 2.0 × 10 − 18
Bothwell, T., Kedar, D., Oelker, E., Robinson, J. M., Bromley, S. L., Tew, W. L., Ye, J., & Kennedy, C. J. (2019) · Metrologia · doi:10.1088/1681-7575/ab4089 · Cited by 324
“Similarly, the range for β is chosen to encompass the weighted mean of values from published literature [2, 29, 25] to one which is consistent with what is observed in Fig.”
BackgroundMethodResultInfluentialSelf-citationSpin–orbit-coupled fermions in an optical lattice clock
Kolkowitz, S., Bromley, S. L., Bothwell, T., Wall, M. L., Marti, G. E., Koller, A. P., Zhang, X., Rey, A. M., & Ye, J. (2017) · Nature · doi:10.1038/nature20811 · Cited by 288
Self-citationThe CIPM list of recommended frequency standard values: guidelines and procedures
Riehle, F., Gill, P., Arias, F., & Robertsson, L. (2018) · Metrologia · doi:10.1088/1681-7575/aaa302 · Cited by 281
Space-borne frequency comb metrology
Lezius, M., Wilken, T., Deutsch, C., Giunta, M., Mandel, O., Thaller, A., Schkolnik, V., Schiemangk, M., Dinkelaker, A., Kohfeldt, A., et al. (2016) · Optica · doi:10.1364/optica.3.001381 · Cited by 272
Optical clock comparison for Lorentz symmetry testing
Sanner, C., Huntemann, N., Lange, R., Tamm, C., Peik, E., Safronova, M. S., & Porsev, S. G. (2019) · Nature · doi:10.1038/s41586-019-0972-2 · Cited by 275
Self-citationRiehle, F. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.235 · Cited by 264
Mehlstäubler, T. E., Grosche, G., Lisdat, C., Schmidt, P. O., & Denker, H. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aab409 · Cited by 263
“These are typically group-II like atoms; most often Sr (Nicholson et al. 2015; Tanabe et al. 2015; Lin et al. 2015; Lodewyck et al. 2016; Grebing et al. 2016; Takano et al. 2016; Hachisu et al. 2017), Yb (Takamoto et al.”
InfluentialDirect detection of the 229Th nuclear clock transition
von der Wense, L., Seiferle, B., Laatiaoui, M., Neumayr, J. B., Maier, H.-J., Wirth, H.-F., Mokry, C., Runke, J., Eberhardt, K., Düllmann, C. E., et al. (2016) · Nature · doi:10.1038/nature17669 · Cited by 262
Matter-wave Atomic Gradiometer Interferometric Sensor (MAGIS-100)
Abe, M., Adamson, P., Borcean, M., Bortoletto, D., Bridges, K., Carman, S. P., Chattopadhyay, S., Coleman, J., Curfman, N. M., DeRose, K., et al. (2021) · Quantum Science and Technology · doi:10.1088/2058-9565/abf719 · Cited by 211
Transportable Optical Lattice Clock with 7 × 10 − 17 Uncertainty
Koller, S. B., Grotti, J., Vogt, S., Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.073601 · Cited by 238
Test of Special Relativity Using a Fiber Network of Optical Clocks
Delva, P., Lodewyck, J., Bilicki, S., Bookjans, E., Vallet, G., Le Targat, R., Pottie, P.-E., Guerlin, C., Meynadier, F., Le Poncin-Lafitte, C., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.221102 · Cited by 227
A Molecular Approach to Quantum Sensing
Yu, C.-J., von Kugelgen, S., Laorenza, D. W., & Freedman, D. E. (2021) · ACS Central Science · doi:10.1021/acscentsci.0c00737 · Cited by 213
Frequency ratio of Yb and Sr clocks with 5 × 10−17 uncertainty at 150 seconds averaging time
Nemitz, N., Ohkubo, T., Takamoto, M., Ushijima, I., Das, M., Ohmae, N., & Katori, H. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.20 · Cited by 221
Clock with 8 × 10 − 19 Systematic Uncertainty
Aeppli, A., Kim, K., Warfield, W., Safronova, M. S., & Ye, J. (2024) · Physical Review Letters · doi:10.1103/physrevlett.133.023401 · Cited by 211
“[3], a lattice depth of 15 .”
BackgroundMethodSelf-citationCavity-mediated collective spin-exchange interactions in a strontium superradiant laser
Norcia, M. A., Lewis-Swan, R. J., Cline, J. R. K., Zhu, B., Rey, A. M., & Thompson, J. K. (2018) · Science · doi:10.1126/science.aar3102 · Cited by 209
Storing Light with Subradiant Correlations in Arrays of Atoms
Facchinetti, G., Jenkins, S. D., & Ruostekoski, J. (2016) · Physical Review Letters · doi:10.1103/physrevlett.117.243601 · Cited by 207
Collective atomic scattering and motional effects in a dense coherent medium
Bromley, S. L., Zhu, B., Bishof, M., Zhang, X., Bothwell, T., Schachenmayer, J., Nicholson, T. L., Kaiser, R., Yelin, S. F., Lukin, M. D., et al. (2016) · Nature Communications · doi:10.1038/ncomms11039 · Cited by 192
Self-citationRoof, S. J., Kemp, K. J., Havey, M. D., & Sokolov, I. M. (2016) · Physical Review Letters · doi:10.1103/physrevlett.117.073003 · Cited by 189
Imaging Optical Frequencies with 100 μHz Precision and 1.1 μm Resolution
Marti, G. E., Hutson, R. B., Goban, A., Campbell, S. L., Poli, N., & Ye, J. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.103201 · Cited by 189
Self-citationCrystalline optical cavity at 4 K with thermal-noise-limited instability and ultralow drift
Robinson, J. M., Oelker, E., Milner, W. R., Zhang, W., Legero, T., Matei, D. G., Riehle, F., Sterr, U., & Ye, J. (2019) · Optica · doi:10.1364/optica.6.000240 · Cited by 175
Self-citationCompact Optical Atomic Clock Based on a Two-Photon Transition in Rubidium
Martin, K. W., Phelps, G., Lemke, N. D., Bigelow, M. S., Stuhl, B., Wojcik, M., Holt, M., Coddington, I., Bishop, M. W., & Burke, J. H. (2018) · Physical Review Applied · doi:10.1103/physrevapplied.9.014019 · Cited by 169
Search for light scalar dark matter with atomic gravitational wave detectors
Arvanitaki, A., Graham, P. W., Hogan, J. M., Rajendran, S., & Van Tilburg, K. (2018) · Physical Review D · doi:10.1103/physrevd.97.075020 · Cited by 171
Time-reversal-based quantum metrology with many-body entangled states
Colombo, S., Pedrozo-Peñafiel, E., Adiyatullin, A. F., Li, Z., Mendez, E., Shu, C., & Vuletić, V. (2022) · Nature Physics · doi:10.1038/s41567-022-01653-5 · Cited by 231
Autonomous Quantum Clocks: Does Thermodynamics Limit Our Ability to Measure Time?
Erker, P., Mitchison, M. T., Silva, R., Woods, M. P., Brunner, N., & Huber, M. (2017) · Physical Review X · doi:10.1103/physrevx.7.031022 · Cited by 210
Differential clock comparisons with a multiplexed optical lattice clock
Zheng, X., Dolde, J., Lochab, V., Merriman, B. N., Li, H., & Kolkowitz, S. (2022) · Nature · doi:10.1038/s41586-021-04344-y · Cited by 150
Realization of a timescale with an accurate optical lattice clock
Grebing, C., Al-Masoudi, A., Dörscher, S., Häfner, S., Gerginov, V., Weyers, S., Lipphardt, B., Riehle, F., Sterr, U., & Lisdat, C. (2016) · Optica · doi:10.1364/optica.3.000563 · Cited by 149
Fifteen years of cold matter on the atom chip: promise, realizations, and prospects
Keil, M., Amit, O., Zhou, S., Groswasser, D., Japha, Y., & Folman, R. (2016) · Journal of Modern Optics · doi:10.1080/09500340.2016.1178820 · Cited by 186
An Atomic-Array Optical Clock with Single-Atom Readout
Madjarov, I. S., Cooper, A., Shaw, A. L., Covey, J. P., Schkolnik, V., Yoon, T. H., Williams, J. R., & Endres, M. (2019) · Physical Review X · doi:10.1103/physrevx.9.041052 · Cited by 181
Origlia, S., Pramod, M. S., Schiller, S., Singh, Y., Bongs, K., Schwarz, R., Al-Masoudi, A., Dörscher, S., Herbers, S., Häfner, S., et al. (2018) · Physical Review A · doi:10.1103/physreva.98.053443 · Cited by 142
Realization of a Λ System with Metastable States of a Capacitively Shunted Fluxonium
Earnest, N., Chakram, S., Lu, Y., Irons, N. J., Naik, R., Leung, N., Ocola, L. E., Czaplewski, D. A., Baker, B., Lawrence, J., et al. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.150504 · Cited by 136
Visible light photonic integrated Brillouin laser
Chauhan, N., Isichenko, A., Liu, K., Wang, J., Zhao, Q., Behunin, R. O., Rakich, P. T., Jayich, A. M., Fertig, C., Hoyt, C., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-24926-8 · Cited by 163
Synthetic Spin-Orbit Coupling in an Optical Lattice Clock
Wall, M. L., Koller, A., Li, S., Zhang, X., Cooper, N. R., Ye, J., & Rey, A. M. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.035301 · Cited by 141
Self-citationFrequency Measurements of Superradiance from the Strontium Clock Transition
Norcia, M. A., Cline, J. R. K., Muniz, J. A., Robinson, J. M., Hutson, R. B., Goban, A., Marti, G. E., Ye, J., & Thompson, J. K. (2018) · Physical Review X · doi:10.1103/physrevx.8.021036 · Cited by 139
“4275(2) nm, limited by the resolution of the wavemeter (calibrated using our narrow-line cooling laser at 689 nm), in good agreement with known results [5, 6, 54, 55].”
BackgroundMethodResultInfluentialSelf-citationExperimental constraint on dark matter detection with optical atomic clocks
Wcisło, P., Morzyński, P., Bober, M., Cygan, A., Lisak, D., Ciuryło, R., & Zawada, M. (2016) · Nature Astronomy · doi:10.1038/s41550-016-0009 · Cited by 116
“The constraint on the transient variation in α that is given by equation (1) can be derived directly from equation (10) and inequality (13).”
BackgroundOperational Magic Intensity for Sr Optical Lattice Clocks
Ushijima, I., Takamoto, M., & Katori, H. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.263202 · Cited by 126
Lee, J., Ding, R., Christensen, J., Rosenthal, R. R., Ison, A. M., Gillund, D., Bossert, D., Fuerschbach, K., Kindel, W., Finnegan, P. S., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-31410-4 · Cited by 122
“49-1-SA) splits into five channels: (1) Lock, (2) Cooling, (3) Repump/ Detection, (4) Raman 1, and (5) Raman 2.”
Critical open-system dynamics in a one-dimensional optical-lattice clock
Henriet, L., Douglas, J. S., Chang, D. E., & Albrecht, A. (2019) · Physical Review A · doi:10.1103/physreva.99.023802 · Cited by 118
Belenchia, A., Carlesso, M., Bayraktar, Ö., Dequal, D., Derkach, I. D., Gasbarri, G., Herr, W., Li, Y. L., Rademacher, M., Sidhu, J. S., et al. (2022) · Physics Reports · doi:10.1016/j.physrep.2021.11.004 · Cited by 126
Frequency Comparison of Two Ca+40 Optical Clocks with an Uncertainty at the 10−17 Level
Huang, Y., Guan, H., Liu, P., Bian, W., Ma, L., Liang, K., Li, T., & Gao, K. (2016) · Physical Review Letters · doi:10.1103/physrevlett.116.013001 · Cited by 116
Leopardi, H., Davila-Rodriguez, J., Quinlan, F., Olson, J., Sherman, J. A., Diddams, S. A., & Fortier, T. M. (2017) · Optica · doi:10.1364/optica.4.000879 · Cited by 115
Operation of an optical atomic clock with a Brillouin laser subsystem
Loh, W., Stuart, J., Reens, D., Bruzewicz, C., Braje, D., Chiaverini, J., Juodawlkis, P., Sage, J., & McConnell, R. (2020) · Nature · doi:10.1038/s41586-020-2981-6 · Cited by 121
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Lodewyck, J., Bilicki, S., Bookjans, E., Robyr, J.-L., Shi, C., Vallet, G., Le Targat, R., Nicolodi, D., Le Coq, Y., Guéna, J., et al. (2016) · Metrologia · doi:10.1088/0026-1394/53/4/1123 · Cited by 102
“duction Over the last years, optical lattice clocks (OLCs) have become the most stable frequency standards, with frequency instabilities as low as 2:2 10 16 in relative units after 1 s of integration [1, 2]. More recently, by reducing the uncertainty on the blackbody radiation induced frequency shift, OLCs with accura…”
BackgroundRaupach, S. M. F., Koczwara, A., & Grosche, G. (2015) · Physical Review A · doi:10.1103/physreva.92.021801 · Cited by 101
Hyperpolarizability and Operational Magic Wavelength in an Optical Lattice Clock
Brown, R. C., Phillips, N. B., Beloy, K., McGrew, W. F., Schioppo, M., Fasano, R. J., Milani, G., Zhang, X., Hinkley, N., Leopardi, H., et al. (2017) · Physical Review Letters · doi:10.1103/physrevlett.119.253001 · Cited by 101
A compact, transportable single-ion optical clock with 7.8 × 10−17 systematic uncertainty
Cao, J., Zhang, P., Shang, J., Cui, K., Yuan, J., Chao, S., Wang, S., Shu, H., & Huang, X. (2017) · Applied Physics B · doi:10.1007/s00340-017-6671-5 · Cited by 101
“Due to the impressive progress in recent years, optical clocks are deemed for the redefinition of SI second in future as they have surpassed the performance of Cs primary clocks in both accuracy and stability([1-5]).”
BackgroundCascaded optical fiber link using the internet network for remote clocks comparison
Chiodo, N., Quintin, N., Stefani, F., Wiotte, F., Camisard, E., Chardonnet, C., Santarelli, G., Amy-Klein, A., Pottie, P.-E., & Lopez, O. (2015) · Optics Express · doi:10.1364/oe.23.033927 · Cited by 100
“This stability performance allows us the comparison of the best optical clocks after only 100 s [22, 23].”
BackgroundPhotonic integrated beam delivery for a rubidium 3D magneto-optical trap
Isichenko, A., Chauhan, N., Bose, D., Wang, J., Kunz, P. D., & Blumenthal, D. J. (2023) · Nature Communications · doi:10.1038/s41467-023-38818-6 · Cited by 132
Development of a strontium optical lattice clock for the SOC mission on the ISS
Bongs, K., Singh, Y., Smith, L., He, W., Kock, O., Świerad, D., Hughes, J., Schiller, S., Alighanbari, S., Origlia, S., et al. (2015) · Comptes Rendus Physique · doi:10.1016/j.crhy.2015.03.009 · Cited by 102
Inner-shell clock transition in atomic thulium with a small blackbody radiation shift
Golovizin, A. A., Fedorova, E., Tregubov, D. O., Sukachev, D., Khabarova, K. Y., Sorokin, V., & Kolachevsky, N. (2019) · Nature Communications · doi:10.1038/s41467-019-09706-9 · Cited by 101
Denker, H., Timmen, L., Voigt, C., Weyers, S., Peik, E., Margolis, H. S., Delva, P., Wolf, P., & Petit, G. (2018) · Journal of Geodesy · doi:10.1007/s00190-017-1075-1 · Cited by 91
Safronova, M. S., Porsev, S. G., Sanner, C., & Ye, J. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.173001 · Cited by 106
Self-citationComparing a mercury optical lattice clock with microwave and optical frequency standards
Tyumenev, R., Favier, M., Bilicki, S., Bookjans, E., Targat, R. L., Lodewyck, J., Nicolodi, D., Coq, Y. L., Abgrall, M., Guéna, J., et al. (2016) · New Journal of Physics · doi:10.1088/1367-2630/18/11/113002 · Cited by 85
Noise and instability of an optical lattice clock
Al-Masoudi, A., Dörscher, S., Häfner, S., Sterr, U., & Lisdat, C. (2015) · Physical Review A · doi:10.1103/physreva.92.063814 · Cited by 84
Robert, C., Conan, J.-M., & Wolf, P. (2016) · Physical Review A · doi:10.1103/physreva.93.033860 · Cited by 84
Optical frequency standards for time and length applications
Hong, F.-L. (2016) · Measurement Science and Technology · doi:10.1088/1361-6501/28/1/012002 · Cited by 90
“At present, the 87Sr optical lattice clock [19, 20], the 171Yb+ single-ion clock (octupole transition) [21], and the 27Al+ single-ion clock [22] have been evaluated as having an uncertainty at the 10−18 level, which is about two orders of magnitude better than that of the current best Cs fountain clocks.”
BackgroundDemonstration of a Timescale Based on a Stable Optical Carrier
Milner, W. R., Robinson, J. M., Kennedy, C. J., Bothwell, T., Kedar, D., Matei, D. G., Legero, T., Sterr, U., Riehle, F., Leopardi, H., et al. (2019) · Physical Review Letters · doi:10.1103/physrevlett.123.173201 · Cited by 93
Self-citationHigh-Density Quantum Sensing with Dissipative First Order Transitions
Raghunandan, M., Wrachtrup, J., & Weimer, H. (2018) · Physical Review Letters · doi:10.1103/physrevlett.120.150501 · Cited by 87
“Hence, the effect we are addressing is quite generic and is also found in related applications; for example, uncertainties caused by interactions are currently one of the most important limiting factors for optical lattice clocks [3, 4].”
BackgroundOhmae, N., Takamoto, M., Takahashi, Y., Kokubun, M., Araki, K., Hinton, A., Ushijima, I., Muramatsu, T., Furumiya, T., Sakai, Y., et al. (2021) · Advanced Quantum Technologies · doi:10.1002/qute.202100015 · Cited by 79
Testing physics beyond the standard model through additional clock transitions in neutral ytterbium
Dzuba, V. A., Flambaum, V. V., & Schiller, S. (2018) · Physical Review A · doi:10.1103/physreva.98.022501 · Cited by 90
Point-to-point stabilized optical frequency transfer with active optics
Dix-Matthews, B. P., Schediwy, S., Gozzard, D. R., Savalle, E., Esnault, F.-X., Lévèque, T., Gravestock, C., D’Mello, D., Karpathakis, S., Tobar, M. E., et al. (2021) · Nature Communications · doi:10.1038/s41467-020-20591-5 · Cited by 85
Controllable Asymmetry Attack on Two-Way Fiber Time Synchronization System
Zhang, C., Li, Y., Chen, X., Zhang, Y., Fu, L., Gong, Y., Wang, H., Huang, W., & Xu, B. (2021) · IEEE photonics journal · doi:10.1109/jphot.2021.3121569 · Cited by 77
State-Dependent Optical Lattices for the Strontium Optical Qubit
Heinz, A., Park, A. J., Šantić, N., Trautmann, J., Porsev, S. G., Safronova, M. S., Bloch, I., & Blatt, S. (2020) · Physical Review Letters · doi:10.1103/physrevlett.124.203201 · Cited by 92
“atomic structure theory and direct lifetime measurements of the P1 state [26] to extract new values for the P1 lifetime.”
BackgroundInfluentialSelf-citationImproving cold-atom sensors with quantum entanglement: Prospects and challenges
Szigeti, S. S., Hosten, O., & Haine, S. A. (2021) · Applied Physics Letters · doi:10.1063/5.0050235 · Cited by 89
Moldover, M. R., Tew, W. L., & Yoon, H. W. (2016) · Nature Physics · doi:10.1038/nphys3618 · Cited by 70
Self-citationBlackbody radiation shift assessment for a lutetium ion clock
Arnold, K. J., Kaewuam, R., Roy, A., Tan, T. R., & Barrett, M. D. (2018) · Nature Communications · doi:10.1038/s41467-018-04079-x · Cited by 70
Self-citationAttractive force on atoms due to blackbody radiation
Haslinger, P., Jaffe, M., Xu, V., Schwartz, O., Sonnleitner, M., Ritsch‐Marte, M., Ritsch, H., & Müller, H. (2017) · Nature Physics · doi:10.1038/s41567-017-0004-9 · Cited by 85
The Search for Variation of Fundamental Constants with Clocks
Safronova, M. S. (2019) · Annalen der Physik · doi:10.1002/andp.201800364 · Cited by 87
Self-citationDetermination of a high spatial resolution geopotential model using atomic clock comparisons
Lion, G., Panet, I., Wolf, P., Guerlin, C., Bize, S., & Delva, P. (2017) · Journal of Geodesy · doi:10.1007/s00190-016-0986-6 · Cited by 66
“More recently, an accuracy of 2.1 × 10−18 (JILA, Nicholson et al. 2015) has been obtained, equivalent to geopotential differences of 0.2 m2s−2, or 2 cm on the geoid.”
InfluentialFirst Evaluation and Frequency Measurement of the Strontium Optical Lattice Clock at NIM
Lin, Y., Wang, Q., Li, Y., Meng, F., Lin, B.-K., Zang, E., Sun, Z. G., Fang, F., Li, T., & Fang, Z. (2015) · Chinese Physics Letters · doi:10.1088/0256-307x/32/9/090601 · Cited by 71
Kobayashi, T., Takamizawa, A., Akamatsu, D., Kawasaki, A., Nishiyama, A., Hosaka, K., Hisai, Y., Wada, M., Inaba, H., Tanabe, T., et al. (2022) · Physical Review Letters · doi:10.1103/physrevlett.129.241301 · Cited by 95
176 Lu + clock comparison at the 10 −18 level via correlation spectroscopy
Zhang, Z., Arnold, K. J., Kaewuam, R., & Barrett, M. D. (2023) · Science Advances · doi:10.1126/sciadv.adg1971 · Cited by 70
Self-citationCold atoms in space: community workshop summary and proposed road-map
Alonso, I., Alpigiani, C., Altschul, B., Araújo, H. M., Arduini, G., Arlt, J., Badurina, L., Balaž, A., Bandarupally, S., Barish, B. C., et al. (2022) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-022-00147-w · Cited by 59
Kulosa, A. P., Fim, D., Zipfel, K., Rühmann, S., Sauer, S., Jha, N., Gibble, K., Ertmer, W. A., Rasel, E. M., Safronova, M. S., et al. (2015) · Physical Review Letters · doi:10.1103/physrevlett.115.240801 · Cited by 75
Self-citationIntercontinental comparison of optical atomic clocks through very long baseline interferometry
Pizzocaro, M., Sekido, M., Takefuji, K., Ujihara, H., Hachisu, H., Nemitz, N., Tsutsumi, M., Kondo, T., Kawai, E., Ichikawa, R., et al. (2021) · Nature Physics · doi:10.1038/s41567-020-01038-6 · Cited by 64
Active vibration isolation of ultra-stable optical reference cavity of space optical clock
He, K., Li, Q., Liu, L., & Yang, H. (2021) · Aerospace Science and Technology · doi:10.1016/j.ast.2021.106633 · Cited by 64
Evaluation of Lattice Light Shift at Low 10−19 Uncertainty for a Shallow Lattice Sr Optical Clock
Kim, K., Aeppli, A., Bothwell, T., & Ye, J. (2023) · Physical Review Letters · doi:10.1103/physrevlett.130.113203 · Cited by 79
Self-citationReid, D. T., Heyl, C. M., Thomson, R. R., Trebino, R. P., Steinmeyer, G., Fielding, H. H., Holzwarth, R., Zhang, Z., Del’Haye, P., Südmeyer, T., et al. (2016) · Journal of Optics · doi:10.1088/2040-8978/18/9/093006 · Cited by 72
Towards a transportable aluminium ion quantum logic optical clock
Hannig, S., Pelzer, L., Scharnhorst, N., Kramer, J., Stepanova, M., Xu, Z. T., Spethmann, N., Leroux, I. D., Mehlstäubler, T. E., & Schmidt, P. O. (2019) · Review of Scientific Instruments · doi:10.1063/1.5090583 · Cited by 75
Analysis of thermal radiation in ion traps for optical frequency standards
Doležal, M., Balling, P., Nisbet-Jones, P. B. R., King, S. A., Jones, J. M., Klein, H. A., Gill, P., Lindvall, T., Wallin, A. E., Merimaa, M., et al. (2015) · Metrologia · doi:10.1088/0026-1394/52/6/842 · Cited by 77
A small weak scale from a small cosmological constant
Arvanitaki, A., Dimopoulos, S., Gorbenko, V., Huang, J., & Tilburg, K. V. (2017) · Journal of High Energy Physics · doi:10.1007/jhep05(2017)071 · Cited by 75
Lasing on a narrow transition in a cold thermal strontium ensemble
Schäffer, S. A., Tang, M., Henriksen, M. R., Jørgensen, A. A., Christensen, B. T. R., & Thomsen, J. W. (2020) · Physical Review A · doi:10.1103/physreva.101.013819 · Cited by 63
Lattice-induced photon scattering in an optical lattice clock
Dörscher, S., Schwarz, R., Al-Masoudi, A., Falke, S., Sterr, U., & Lisdat, C. (2018) · Physical Review A · doi:10.1103/physreva.97.063419 · Cited by 60
Metadata
- Authors
- Nicholson, T. L., Campbell, S. L., Hutson, R. B., Marti, G. E., Bloom, B. J., McNally, R. L., Zhang, W., Barrett, M. D., Safronova, M. S., Strouse, G. F., Tew, W. L., & Ye, J.
- Affiliations
- National Institute of Standards and Technology (US)
- Centre for Quantum Technologies (SG)
- Corresponding author
- Ye, J.
- ORCID
- Venue
- Nature Communications
- Published
- 2015-04-21
- Volume
- 6
- Issue
- 1
- Pages
- 6896-6896
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC4411304
- OpenAlex
- W2073958075
- Cited by
- 780
- References
- 53
- Citations by year
- 2026: 33 · 2025: 48 · 2024: 63 · 2023: 61 · 2022: 60 · 2021: 59 · 2020: 68 · 2019: 84 · 2018: 86 · 2017: 81 · 2016: 102 · 2015: 35
- FWCI
- 51.26
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by)
- arXiv (Cornell University) (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- National University of Singapore (submittedVersion, cc-by)
- RePEc: Research Papers in Economics (submittedVersion)
- arXiv (Cornell University)
- Funders
- National Science Foundation
- National Institute of Standards and Technology
- Advanced Research Projects Agency
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Computer Science › Computer Networks and Communications › Network Time Synchronization Technologies
- Keywords
- optical lattice clock, strontium-87, systematic uncertainties, fractional frequency stability, AC Stark shift, blackbody radiation shift, thermal environment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.