The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Intracellular recording of action potentials by nanopillar electroporation
Open accessAbstract
Action potentials have a central role in the nervous system and in many cellular processes, notably those involving ion channels. The accurate measurement of action potentials requires efficient coupling between the cell membrane and the measuring electrodes. Intracellular recording methods such as patch clamping involve measuring the voltage or current across the cell membrane by accessing the cell interior with an electrode, allowing both the amplitude and shape of the action potentials to be recorded faithfully with high signal-to-noise ratios. However, the invasive nature of intracellular methods usually limits the recording time to a few hours, and their complexity makes it difficult to simultaneously record more than a few cells. Extracellular recording methods, such as multielectrode arrays and multitransistor arrays, are non-invasive and allow long-term and multiplexed measurements. However, extracellular recording sacrifices the one-to-one correspondence between the cells and electrodes, and also suffers from significantly reduced signal strength and quality. Extracellular techniques are not, therefore, able to record action potentials with the accuracy needed to explore the properties of ion channels. As a result, the pharmacological screening of ion-channel drugs is usually performed by low-throughput intracellular recording methods. The use of nanowire transistors, nanotube-coupled transistors and micro gold-spine and related electrodes can significantly improve the signal strength of recorded action potentials. Here, we show that vertical nanopillar electrodes can record both the extracellular and intracellular action potentials of cultured cardiomyocytes over a long period of time with excellent signal strength and quality. Moreover, it is possible to repeatedly switch between extracellular and intracellular recording by nanoscale electroporation and resealing processes. Furthermore, vertical nanopillar electrodes can detect subtle changes in action potentials induced by drugs that target ion channels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gene transfer into mouse lyoma cells by electroporation in high electric fields.
Neumann, E., Schaefer-Ridder, M., Wang, Y., & Hofschneider, P. H. (1982) · The EMBO Journal · doi:10.1002/j.1460-2075.1982.tb01257.x · Cited by 2,502
Claycomb, W. C., Lanson, N. A., Stallworth, B. S., Egeland, D. B., Delcarpio, J. B., Bahinski, A., & Izzo, N. J. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.6.2979 · Cited by 1,546
Structure and Function of Voltage-Sensitive Ion Channels
Catterall, W. A. (1988) · Science · doi:10.1126/science.2459775 · Cited by 1,174
Three-Dimensional, Flexible Nanoscale Field-Effect Transistors as Localized Bioprobes
Tian, B., Cohen-Karni, T., Qing, Q., Duan, X., Xie, P., & Lieber, C. M. (2010) · Science · doi:10.1126/science.1192033 · Cited by 798
Dielectric Breakdown of Cell Membranes
Zimmermann, U., Pilwat, G., & Riemann, F. (1974) · Biophysical Journal · doi:10.1016/s0006-3495(74)85956-4 · Cited by 762
Vertical silicon nanowires as a universal platform for delivering biomolecules into living cells
Shalek, A. K., Robinson, J. T., Karp, E. S., Lee, J. S., Ahn, D.-R., Yoon, M.-H., Sutton, A., Jorgolli, M., Gertner, R. S., Gujral, T. S., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0909350107 · Cited by 569
Recording action potentials from cultured neurons with extracellular microcircuit electrodes
Pine, J. (1980) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(80)90042-4 · Cited by 543
Interfacing Silicon Nanowires with Mammalian Cells
Kim, W., Ng, J. K., Kunitake, M. E., Conklin, B. R., & Yang, P. (2007) · Journal of the American Chemical Society · doi:10.1021/ja071456k · Cited by 528
Chang, D. C., & Reese, T. S. (1990) · Biophysical Journal · doi:10.1016/s0006-3495(90)82348-1 · Cited by 522
Intracellular recordings of action potentials by an extracellular nanoscale field-effect transistor
Duan, X., Gao, R., Xie, P., Cohen-Karni, T., Qing, Q., Choe, H. S., Tian, B., Jiang, X., & Lieber, C. M. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2011.223 · Cited by 456
Cited by
Chemically defined generation of human cardiomyocytes
Burridge, P. W., Matsa, E., Shukla, P., Lin, Z. C., Churko, J. M., Ebert, A. D., Lan, F., Diecke, S., Huber, B., Mordwinkin, N. M., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2999 · Cited by 1,606
Self-citationMulti-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
25th Anniversary Article: Semiconductor Nanowires – Synthesis, Characterization, and Applications
Dasgupta, N. P., Sun, J., Liu, C., Brittman, S., Andrews, S. C., Lim, J., Gao, H., Yan, R., & Yang, P. (2014) · Advanced Materials · doi:10.1002/adma.201305929 · Cited by 880
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Zhang, A., & Lieber, C. M. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00608 · Cited by 621
Lei, T., Guan, M., Liu, J., Lin, H.-C., Pfattner, R., Shaw, L., McGuire, A. F., Huang, T.-C., Shao, L., Cheng, K.-T., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701478114 · Cited by 464
Biosensor technology: recent advances in threat agent detection and medicine
Kirsch, J., Siltanen, C., Zhou, Q., Revzin, A., & Simonian, A. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60141b · Cited by 462
Chiappini, C., De Rosa, E., Martinez, J. O., Liu, X., Steele, J., Stevens, M. M., & Tasciotti, E. (2015) · Nature Materials · doi:10.1038/nmat4249 · Cited by 446
Materials-Driven Soft Wearable Bioelectronics for Connected Healthcare
Gong, S., Lu, Y., Yin, J., Levin, A., & Cheng, W. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00502 · Cited by 411
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Nanotools for Neuroscience and Brain Activity Mapping
Alivisatos, A. P., Andrews, A. M., Boyden, E. S., Chun, M., Church, G. M., Deisseroth, K., Donoghue, J. P., Fraser, S. E., Lippincott-Schwartz, J., Looger, L. L., et al. (2013) · ACS Nano · doi:10.1021/nn4012847 · Cited by 356
Cell-Based Biosensors and Their Application in Biomedicine
Liu, Q., Wu, C., Cai, H., Hu, N., Zhou, J., & Wang, P. (2014) · Chemical Reviews · doi:10.1021/cr2003129 · Cited by 348
Nanostraw–Electroporation System for Highly Efficient Intracellular Delivery and Transfection
Xie, X., Xu, A. M., Leal-Ortiz, S., Cao, Y., Garner, C. C., & Melosh, N. A. (2013) · ACS Nano · doi:10.1021/nn400874a · Cited by 314
A nanoelectrode array for obtaining intracellular recordings from thousands of connected neurons
Abbott, J., Ye, T., Krenek, K., Gertner, R. S., Ban, S., Kim, Y., Qin, L., Wu, W., Park, H., & Ham, D. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0455-7 · Cited by 272
CMOS nanoelectrode array for all-electrical intracellular electrophysiological imaging
Abbott, J., Ye, T., Qin, L., Jorgolli, M., Gertner, R. S., Ham, D., & Park, H. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.3 · Cited by 266
A Review on Electroporation-Based Intracellular Delivery
Shi, J., Ma, Y., Zhu, J., Chen, Y., Sun, Y., Yao, Y., Yang, Z., & Xie, J. (2018) · Molecules · doi:10.3390/molecules23113044 · Cited by 261
Qing, Q., Jiang, Z., Xu, L., Gao, R., Mai, L., & Lieber, C. M. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2013.273 · Cited by 257
High‐Aspect‐Ratio Nanostructured Surfaces as Biological Metamaterials
Higgins, S. G., Becce, M., Belessiotis‐Richards, A., Seong, H., Sero, J. E., & Stevens, M. M. (2020) · Advanced Materials · doi:10.1002/adma.201903862 · Cited by 256
Neural Dust: An Ultrasonic, Low Power Solution for Chronic Brain-Machine Interfaces
Seo, D., Carmena, J. M., Rabaey, J. M., Alon, E., & Maharbiz, M. M. (2013) · arXiv · doi:10.48550/arxiv.1307.2196 · Cited by 172
Mesh electronics: a new paradigm for tissue-like brain probes
Hong, G., Yang, X., Zhou, T., & Lieber, C. M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2017.11.007 · Cited by 159
Recent advances in neural electrode–tissue interfaces
Woeppel, K., Yang, Q., & Cui, X. T. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.09.003 · Cited by 99
Biomedical Implants with Charge‐Transfer Monitoring and Regulating Abilities
Wang, D., Tan, J., Zhu, H., Mei, Y., & Liu, X. (2021) · Advanced Science · doi:10.1002/advs.202004393 · Cited by 49
Sensors-integrated organ-on-a-chip for biomedical applications
Chen, H., Luo, Z., Lin, X., Zhu, Y., & Zhao, Y. (2023) · Nano Research · doi:10.1007/s12274-023-5651-9 · Cited by 47
Perspectives on electrical neural recording: a revisit to the fundamental concepts
Guo, L. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab702f · Cited by 28
Metadata
- Authors
- Xie, C., Lin, Z., Hanson, L., Cui, Y., & Cui, B.
- Venue
- Nature Nanotechnology
- Published
- 2012-02-12
- Volume
- 7
- Issue
- 3
- Pages
- 185-190
- ISSN
- 1748-3387 (ISSN-L)
- 1748-3395
- OpenAlex
- W2015898149
- Cited by
- 593
- References
- 20
- FWCI
- 14.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.