A Generic Integrated Physiologically based Whole‐body Model of the Glucose‐Insulin‐Glucagon Regulatory System
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Models of glucose metabolism are a valuable tool for fundamental and applied medical research in diabetes. Use cases range from pharmaceutical target selection to automatic blood glucose control. Standard compartmental models represent little biological detail, which hampers the integration of multiscale data and confines predictive capabilities. We developed a detailed, generic physiologically based whole‐body model of the glucose‐insulin‐glucagon regulatory system, reflecting detailed physiological properties of healthy populations and type 1 diabetes individuals expressed in the respective parameterizations. The model features a detailed representation of absorption models for oral glucose, subcutaneous insulin and glucagon, and an insulin receptor model relating pharmacokinetic properties to pharmacodynamic effects. Model development and validation is based on literature data. The quality of predictions is high and captures relevant observed inter‐ and intra‐individual variability. In the generic form, the model can be applied to the development and validation of novel diabetes treatment strategies. CPT: Pharmacometrics & Systems Pharmacology (2013) 2, e65; doi:10.1038/psp.2013.40; published online 14 August 2013
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative estimation of insulin sensitivity.
Bergman, R. N., Ider, Y. Z., Bowden, C. R., & Cobelli, C. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.236.6.e667 · Cited by 1,874 · cited 2×
“All compartments are interconnected via passive convection and diffusion flows (1–5) and facilitative transports (7).”
BackgroundNonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
Self-citationMeal Simulation Model of the Glucose-Insulin System
Dalla Man, C., Rizza, R. A., & Cobelli, C. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.893506 · Cited by 955
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes
El-Khatib, F. H., Russell, S. J., Nathan, D. M., Sutherlin, R. G., & Damiano, E. R. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000619 · Cited by 403
Coefficients of normal blood glucose regulation
Bolie, V. W. (1961) · Journal of Applied Physiology · doi:10.1152/jappl.1961.16.5.783 · Cited by 349 · cited 1×
“Bound to insulin receptors (IR) insulin is eliminated from the plasma by trans-endothelial transport (6), and in the interstitial space (9) triggering molecular signaling in target tissues inherently coupling its PK and PD (9, 10).”
BackgroundClosed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Model Predictive Control of Type 1 Diabetes: An in Silico Trial
Magni, L., Raimondo, D. M., Bossi, L., Dalla Man, C., De Nicolao, G., Kovatchev, B., & Cobelli, C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100603 · Cited by 317
Diurnal pattern to insulin secretion and insulin action in healthy individuals
Saad, A., Dalla Man, C., Nandy, D. K., Levine, J. A., Bharucha, A. E., Rizza, R. A., Basu, R., Carter, R. E., Cobelli, C., Kudva, Y. C., et al. (2012) · Diabetes · doi:10.2337/db11-1478 · Cited by 297
Eissing, T. (2011) · Frontiers in Physiology · doi:10.3389/fphys.2011.00004 · Cited by 204
Cited by
Applied Concepts in PBPK Modeling: How to Build a PBPK/PD Model
Kuepfer, L., Niederalt, C., Wendl, T., Schlender, J., Willmann, S., Lippert, J., Block, M., Eissing, T., & Teutonico, D. (2016) · CPT: Pharmacometrics & Systems Pharmacology · doi:10.1002/psp4.12134 · Cited by 425
“• Scaling between different treatments scenarios by simulating specific dosing schemes.(10) • Assessing the impact of different drug formulations by”
BackgroundSelf-citationJamei, M. (2016) · Current Pharmacology Reports · doi:10.1007/s40495-016-0059-9 · Cited by 244
Wong, H., Bohnert, T., Damian-Iordache, V., Gibson, C., Hsu, C.-P., Krishnatry, A. S., Liederer, B. M., Lin, J., Lu, Q., Mettetal, J. T., et al. (2017) · Drug Discovery Today · doi:10.1016/j.drudis.2017.04.015 · Cited by 27
Balazki, P., Schaller, S., Eissing, T., & Lehr, T. (2018) · CPT: Pharmacometrics & Systems Pharmacology · doi:10.1002/psp4.12359 · Cited by 19
Self-citationMathematical modeling of the glucagon challenge test
Masroor, S., van Dongen, M. G. J., Alvarez-Jimenez, R., Burggraaf, K., Peletier, L. A., & Peletier, M. A. (2019) · Journal of Pharmacokinetics and Pharmacodynamics · doi:10.1007/s10928-019-09655-2 · Cited by 12
Metadata
- Authors
- Schaller, S., Willmann, S., Lippert, J., Schaupp, L., Pieber, T., Schuppert, A., & Eissing, T.
- Venue
- CPT: Pharmacometrics & Systems Pharmacology
- Publisher
- Wiley
- Published
- 2013-08
- Volume
- 2
- Issue
- 8
- Pages
- 1-10
- ISSN
- 2163-8306 (ISSN-L)
- OpenAlex
- W2024284722
- Cited by
- 71
- References
- 15
- FWCI
- 5.90
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Generic Integrated Physiologically based Whole‐body Model of the Glucose‐Insulin‐Glucagon Regulatory System. https://app.cochat.ai/papers/10.1038/psp.2013.40
- The paper
- Schaller, S., Willmann, S., Lippert, J., Schaupp, L., Pieber, T., Schuppert, A., & Eissing, T. (2013). A Generic Integrated Physiologically based Whole‐body Model of the Glucose‐Insulin‐Glucagon Regulatory System. CPT: Pharmacometrics & Systems Pharmacology. https://doi.org/10.1038/psp.2013.40
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.