Superresolution structured illumination microscopy reconstruction algorithms: a review
Open accessThe DOI matches its Crossref record; 158 of the 158 references it cites were found in a registry or an index.
Abstract
Structured illumination microscopy (SIM) has become the standard for next-generation wide-field microscopy, offering ultrahigh imaging speed, superresolution, a large field-of-view, and long-term imaging. Over the past decade, SIM hardware and software have flourished, leading to successful applications in various biological questions. However, unlocking the full potential of SIM system hardware requires the development of advanced reconstruction algorithms. Here, we introduce the basic theory of two SIM algorithms, namely, optical sectioning SIM (OS-SIM) and superresolution SIM (SR-SIM), and summarize their implementation modalities. We then provide a brief overview of existing OS-SIM processing algorithms and review the development of SR-SIM reconstruction algorithms, focusing primarily on 2D-SIM, 3D-SIM, and blind-SIM. To showcase the state-of-the-art development of SIM systems and assist users in selecting a commercial SIM system for a specific application, we compare the features of representative off-the-shelf SIM systems. Finally, we provide perspectives on the potential future developments of SIM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NIH Image to ImageJ: 25 years of image analysis
Schneider, C. A., Rasband, W. S., & Eliceiri, K. W. (2012) · Nature Methods · doi:10.1038/nmeth.2089 · Cited by 64,638
Boyd, S., Parikh, N., Chu, E., Peleato, B., & Eckstein, J. (2011) · Foundations and Trends® in Machine Learning · doi:10.1561/2200000016 · Cited by 17,075
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
van der Vorst, H. A. (1992) · SIAM Journal on Scientific and Statistical Computing · doi:10.1137/0913035 · Cited by 5,308
Bayesian-Based Iterative Method of Image Restoration*
Richardson, W. H. (1972) · Journal of the Optical Society of America · doi:10.1364/josa.62.000055 · Cited by 4,160
An iterative technique for the rectification of observed distributions
Lucy, L. B. (1974) · The Astronomical Journal · doi:10.1086/111605 · Cited by 3,866
Gustafsson, M. G. L. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00710.x · Cited by 3,786
Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
Beiträge zur Theorie des Mikroskops und der mikroskopischen Wahrnehmung
Abbe, E. (1873) · Archiv für Mikroskopische Anatomie · doi:10.1007/bf02956173 · Cited by 2,724
Gustafsson, M. G. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406877102 · Cited by 2,224
Fluorescence microscopy with diffraction resolution barrier broken by stimulated emission
Klar, T. A., Jakobs, S., Dyba, M., Egner, A., & Hell, S. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.15.8206 · Cited by 1,869
Wide-field, high-resolution Fourier ptychographic microscopy
Zheng, G., Horstmeyer, R., & Yang, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.187 · Cited by 1,829
Gustafsson, M. G. L., Shao, L., Carlton, P. M., Wang, C. J. R., Golubovskaya, I. N., Cande, W. Z., Agard, D. A., & Sedat, J. W. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.120345 · Cited by 1,557 · cited 6×
“In 2008, Gustafsson et al.12 first designed a 3D-SIM system with true optical sectioning.”
MethodInfluentialBreaking the Diffraction Barrier: Optical Microscopy on a Nanometric Scale
Betzig, E., Trautman, J. K., Harris, T. D., Weiner, J. S., & Kostelak, R. L. (1991) · Science · doi:10.1126/science.251.5000.1468 · Cited by 1,534
Highly inclined thin illumination enables clear single-molecule imaging in cells
Tokunaga, M., Imamoto, N., & Sakata-Sogawa, K. (2008) · Nature Methods · doi:10.1038/nmeth1171 · Cited by 1,305
Wide-field subdiffraction imaging by accumulated binding of diffusing probes
Sharonov, A., & Hochstrasser, R. M. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609643104 · Cited by 1,151
Method of obtaining optical sectioning by using structured light in a conventional microscope
Neil, M. A. A., Juškaitis, R., & Wilson, T. (1997) · Optics Letters · doi:10.1364/ol.22.001905 · Cited by 1,143
An Empirical Bayesian Strategy for Solving the Simultaneous Sparse Approximation Problem
Wipf, D. P., & Rao, B. D. (2007) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2007.894265 · Cited by 911
Subdiffraction resolution in far-field fluorescence microscopy
Klar, T. A., & Hell, S. W. (1999) · Optics Letters · doi:10.1364/ol.24.000954 · Cited by 864
Deep learning enables cross-modality super-resolution in fluorescence microscopy
Wang, H., Rivenson, Y., Jin, Y., Wei, Z., Gao, R., Günaydın, H., Bentolila, L. A., Kural, C., & Ozcan, A. (2019) · Nature Methods · doi:10.1038/s41592-018-0239-0 · Cited by 782 · cited 6×
“In 2019, Wang et al.78 proposed a Fourier bandpass filtering algorithm to reconstruct optical section images by shifting the in-focus signals to the +1st order in the Fourier domain.”
BackgroundInfluentialExtended-resolution structured illumination imaging of endocytic and cytoskeletal dynamics
Li, D., Shao, L., Chen, B.-C., Zhang, X., Zhang, M., Moses, B., Milkie, D. E., Beach, J. R., Hammer, J. A., Pasham, M., et al. (2015) · Science · doi:10.1126/science.aab3500 · Cited by 748 · cited 1×
“In 2015, Li et al.(56) proposed a technique called patterned activation of photoswitchable fluorophores (PA NL-SIM) that improved the resolution of live-cell SIM to a range of 45–62 nm using approximately 20–40 frames of raw images (Fig.”
BackgroundSelf-citationSuper-resolution video microscopy of live cells by structured illumination
Kner, P., Chhun, B. B., Griffis, E. R., Winoto, L., & Gustafsson, M. G. L. (2009) · Nature Methods · doi:10.1038/nmeth.1324 · Cited by 734
Fast, long-term, super-resolution imaging with Hessian structured illumination microscopy
Huang, X., Fan, J., Li, L., Liu, H., Wu, R., Wu, Y., Wei, L., Mao, H., Lal, A., Xi, P., et al. (2018) · Nature Biotechnology · doi:10.1038/nbt.4115 · Cited by 661 · cited 2×
“In 2018, Huang et al.115 reported a deconvolution method for SIM, called Hessian-SIM, which utilized prior knowledge of the continuity of multidimensional biological structures based on Hessian matrices.”
MethodSelf-citationChapter 13 Fluorescence Microscopy in Three Dimensions
Agard, D. A., Hiraoka, Y., Shaw, P., & Sedat, J. W. (1989) · Methods in Cell Biology · doi:10.1016/s0091-679x(08)60986-3 · Cited by 649
Guo, Y., Li, D., Zhang, S., Yang, Y., Liu, J.-J., Wang, X., Liu, C., Milkie, D. E., Moore, R. P., Tulu, U. S., et al. (2018) · Cell · doi:10.1016/j.cell.2018.09.057 · Cited by 648 · cited 2×
“Later, in 2018, Guo et al.(129) employed SIMILR in grazing incidence SIM, which utilizes highly inclined laminar illumination(130).”
MethodSelf-citationLaterally modulated excitation microscopy: improvement of resolution by using a diffraction grating:
Heintzmann, R., & Cremer, C. G. (1999) · SPIE Proceedings · doi:10.1117/12.336833 · Cited by 589
Super-Resolution Structured Illumination Microscopy
Heintzmann, R., & Huser, T. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00218 · Cited by 574 · cited 2×
“To remove the out-of-focus information and obtain the whole structure of a 3D sample, Neil et al.(15,23) introduced the OS-SIM algorithm.”
MethodSaturated patterned excitation microscopy—a concept for optical resolution improvement
Heintzmann, R., Jovin, T. M., & Cremer, C. (2002) · Journal of the Optical Society of America A · doi:10.1364/josaa.19.001599 · Cited by 566 · cited 2×
“Category 1: saturated SIM Heintzmann et al.(65) first developed the saturated SIM theory in 2022, which uses fluorescence saturation as a nonlinear process to relate emission to excitation.”
BackgroundSuper-resolution 3D microscopy of live whole cells using structured illumination
Shao, L., Kner, P., Rego, E. H., & Gustafsson, M. G. L. (2011) · Nature Methods · doi:10.1038/nmeth.1734 · Cited by 533
Structured illumination microscopy using unknown speckle patterns
Mudry, E., Belkebir, K., Girard, J., Savatier, J., Moal, E. L., Nicoletti, C., Allain, M., & Sentenac, A. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.83 · Cited by 512 · cited 2×
“To overcome this problem, Mudry et al.154 developed a blind-SIM reconstruction method in 2012 for illuminating samples with random light speckles.”
MethodApplications, promises, and pitfalls of deep learning for fluorescence image reconstruction
Belthangady, C., & Royer, L. A. (2019) · Nature Methods · doi:10.1038/s41592-019-0458-z · Cited by 510
Deconvolution methods for 3-D fluorescence microscopy images
Sarder, P., & Nehorai, A. (2006) · IEEE Signal Processing Magazine · doi:10.1109/msp.2006.1628876 · Cited by 479
York, A. G., Parekh, S. H., Nogare, D. D., Fischer, R. S., Temprine, K., Mione, M., Chitnis, A. B., Combs, C. A., & Shroff, H. (2012) · Nature Methods · doi:10.1038/nmeth.2025 · Cited by 472
Evaluation and development of deep neural networks for image super-resolution in optical microscopy
Qiao, C., Li, D., Guo, Y., Liu, C., Jiang, T., Dai, Q., & Li, D. (2021) · Nature Methods · doi:10.1038/s41592-020-01048-5 · Cited by 465 · cited 3×
“In 2021, Qiao et al.189 developed a deep Fourier channel attention network (DFCAN) and its derivative DFGAN, which were trained using a GAN strategy.”
MethodSelf-citationNixon-Abell, J., Obara, C. J., Weigel, A. V., Li, D., Legant, W. R., Xu, C. S., Pasolli, H. A., Harvey, K., Hess, H. F., Betzig, E., et al. (2016) · Science · doi:10.1126/science.aaf3928 · Cited by 455
Self-citationI5M: 3D widefield light microscopy with better than 100 nm axial resolution
Gustafsson, Agard, & Sedat (1999) · Journal of Microscopy · doi:10.1046/j.1365-2818.1999.00576.x · Cited by 417
Sparse deconvolution improves the resolution of live-cell super-resolution fluorescence microscopy
Zhao, W., Zhao, S., Li, L., Huang, X., Xing, S., Zhang, Y., Qiu, G., Han, Z., Shang, Y., Sun, D.-E., et al. (2022) · Nature Biotechnology · doi:10.1038/s41587-021-01092-2 · Cited by 408 · cited 3×
“To overcome this problem, Zhao et al.97 reported an enhanced IRT algorithm that can handle arbitrary phase shifts.”
BackgroundSelf-citationInstant super-resolution imaging in live cells and embryos via analog image processing
York, A. G., Chandris, P., Nogare, D. D., Head, J., Wawrzusin, P., Fischer, R. S., Chitnis, A., & Shroff, H. (2013) · Nature Methods · doi:10.1038/nmeth.2687 · Cited by 404
Rego, E. H., Shao, L., Macklin, J. J., Winoto, L., Johansson, G. A., Kamps-Hughes, N., Davidson, M. W., & Gustafsson, M. G. L. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1107547108 · Cited by 399 · cited 2×
“Category 2: nonlinear SIM based on fluorescent photoswitchable proteins In 2012, Rego et al.68 discovered that the reversible photoswitching (Fig.”
BackgroundFaster, sharper, and deeper: structured illumination microscopy for biological imaging
Wu, Y., & Shroff, H. (2018) · Nature Methods · doi:10.1038/s41592-018-0211-z · Cited by 375
Parameter-free image resolution estimation based on decorrelation analysis
Descloux, A., Grußmayer, K. S., & Radenovic, A. (2019) · Nature Methods · doi:10.1038/s41592-019-0515-7 · Cited by 363 · cited 2×
“In 2019, Descloux et al.(145) proposed a rapid image resolution estimation method called decorrelation analysis, which also uses a single image without prior knowledge.”
MethodQuantitative mapping and minimization of super-resolution optical imaging artifacts
Culley, S., Albrecht, D., Jacobs, C., Pereira, P. M., Leterrier, C., Mercer, J., & Henriques, R. (2018) · Nature Methods · doi:10.1038/nmeth.4605 · Cited by 354
Rapid 3D light-sheet microscopy with a tunable lens
Fahrbach, F. O., Voigt, F. F., Schmid, B., Helmchen, F., & Huisken, J. (2013) · Optics Express · doi:10.1364/oe.21.021010 · Cited by 347
Müller, M., Mönkemöller, V., Hennig, S., Hübner, W., & Huser, T. (2016) · Nature Communications · doi:10.1038/ncomms10980 · Cited by 340
Strategic and practical guidelines for successful structured illumination microscopy
Demmerle, J., Innocent, C., North, A. J., Ball, G., Müller, M., Miron, E., Matsuda, A., Dobbie, I. M., Markaki, Y., & Schermelleh, L. (2017) · Nature Protocols · doi:10.1038/nprot.2017.019 · Cited by 336
Andresen, M., Stiel, A. C., Fölling, J., Wenzel, D., Schönle, A., Egner, A., Eggeling, C., Hell, S. W., & Jakobs, S. (2008) · Nature Biotechnology · doi:10.1038/nbt.1493 · Cited by 310
SIMcheck: a Toolbox for Successful Super-resolution Structured Illumination Microscopy
Ball, G., Demmerle, J., Kaufmann, R., Davis, I., Dobbie, I. M., & Schermelleh, L. (2015) · Scientific Reports · doi:10.1038/srep15915 · Cited by 294
Deep learning enables structured illumination microscopy with low light levels and enhanced speed
Jin, L., Liu, B., Zhao, F., Hahn, S., Dong, B., Song, R., Elston, T. C., Xu, Y., & Hahn, K. M. (2020) · Nature Communications · doi:10.1038/s41467-020-15784-x · Cited by 253 · cited 2×
“In 2020, Jin et al.(188) proposed U-Netbased frameworks, namely, U-Net-SIM3 and U-NetSIM15, which reduced the number of raw images by 5-fold and retrieved superresolution information from low-light samples.”
Structured Illumination Microscopy Image Reconstruction Algorithm
Lal, A., Shan, C., & Xi, P. (2016) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2016.2521542 · Cited by 231 · cited 3×
“In 2016, Lal et al.(27) provided a comprehensive theoretical overview of 2D-SIM algorithms, including determining the illumination frequency vector using the ACR method and estimating the phase offset through iterative optimization of the correlation function between the illumination pattern and the sample’s Fourier i…”
MethodInfluentialSelf-citationQiao, C., Li, D., Liu, Y., Zhang, S., Liu, K., Liu, C., Guo, Y., Jiang, T., Fang, C., Li, N., et al. (2023) · Nature Biotechnology · doi:10.1038/s41587-022-01471-3 · Cited by 214 · cited 3×
“In 2021, Qiao et al.189 developed a deep Fourier channel attention network (DFCAN) and its derivative DFGAN, which were trained using a GAN strategy.”
BackgroundSelf-citationPhase optimisation for structured illumination microscopy
Wicker, K., Mandula, O., Best, G., Fiolka, R. P., & Heintzmann, R. (2013) · Optics Express · doi:10.1364/oe.21.002032 · Cited by 211 · cited 2×
“In 2013, Wicker et al.94 developed an iterative optimization method to determine the pattern phases using the COR between separated components in cases where the illumination pattern was too fine to detect.”
MethodGuide to light-sheet microscopy for adventurous biologists
Reynaud, E. G., Peychl, J., Huisken, J., & Tomancak, P. (2015) · Nature Methods · doi:10.1038/nmeth.3222 · Cited by 209
Extended resolution fluorescence microscopy
Gustafsson, M. G. (1999) · Current Opinion in Structural Biology · doi:10.1016/s0959-440x(99)00016-0 · Cited by 199
Wide-field fluorescence sectioning with hybrid speckle and uniform-illumination microscopy
Lim, D., Chu, K. K., & Mertz, J. (2008) · Optics Letters · doi:10.1364/ol.33.001819 · Cited by 196
Fourier ring correlation simplifies image restoration in fluorescence microscopy
Koho, S., Tortarolo, G., Castello, M., Deguchi, T., Diaspro, A., & Vicidomini, G. (2019) · Nature Communications · doi:10.1038/s41467-019-11024-z · Cited by 189 · cited 2×
“Regarding resolution assessment methods, Koho et al.144 proposed a method based on Fourier ring correlation (FRC) analysis, where a single image is divided into four subsets (i.e., two-image pairs) and used to estimate the effective PSF in Wiener and iterative RL deconvolution.”
MethodThree-dimensional Image Reconstruction from the Viewpoint of information Theory
KLUG, A., & CROWTHER, R. A. (1972) · Nature · doi:10.1038/238435a0 · Cited by 188
Structured illumination microscopy of a living cell
Hirvonen, L. M., Wicker, K., Mandula, O., & Heintzmann, R. (2009) · European Biophysics Journal · doi:10.1007/s00249-009-0501-6 · Cited by 188
High-fidelity structured illumination microscopy by point-spread-function engineering
Wen, G., Li, S., Wang, L., Chen, X., Sun, Z., Liang, Y., Jin, X., Xing, Y., Jiu, Y., Tang, Y., et al. (2021) · Light Science & Applications · doi:10.1038/s41377-021-00513-w · Cited by 186
Self-citationHigh-definition imaging using line-illumination modulation microscopy
Zhong, Q., Li, A., Jin, R., Zhang, D., Li, X., Jia, X., Ding, Z., Luo, P., Zhou, C., Jiang, C., et al. (2021) · Nature Methods · doi:10.1038/s41592-021-01074-x · Cited by 171 · cited 4×
“In 2021, Zhong et al.(43) further developed a high-definition fluorescent micro-optical sectioning tomography (HD-fMOST) method for whole-brain optical imaging with submicrometer-voxel resolution, based on the LiMo method (Fig.”
MethodInfluentialI5S: Wide-Field Light Microscopy with 100-nm-Scale Resolution in Three Dimensions
Shao, L., Isaac, B., Uzawa, S., Agard, D. A., Sedat, J. W., & Gustafsson, M. G. L. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.120352 · Cited by 169
Plasmonic Structured Illumination Microscopy
Wei, F., & Liu, Z. (2010) · Nano Letters · doi:10.1021/nl1011068 · Cited by 168
Aberrations and adaptive optics in super-resolution microscopy
Booth, M., Andrade, D., Burke, D., Patton, B., & Zurauskas, M. (2015) · Microscopy · doi:10.1093/jmicro/dfv033 · Cited by 168
Video-rate multi-color structured illumination microscopy with simultaneous real-time reconstruction
Markwirth, A., Lachetta, M., Mönkemöller, V., Heintzmann, R., Hübner, W., Huser, T. R., & Muller, M. W. (2019) · Nature Communications · doi:10.1038/s41467-019-12165-x · Cited by 162 · cited 2×
“For example, in 2019, Markwirth et al.132 proposed a video-rate immediate GPU-accelerated open-source reconstruction (VIGOR) method by recreating, modifying, and extending the fastSIM134 approach and image reconstruction software.”
MethodWide Field Super-Resolution Surface Imaging through Plasmonic Structured Illumination Microscopy
Wei, F., Lu, D., Shen, H., Wan, W., Ponsetto, J. L., Huang, E., & Liu, Z. (2014) · Nano Letters · doi:10.1021/nl501695c · Cited by 161
High-resolution fluorescence imaging via pattern-illuminated Fourier ptychography
Dong, S., Nanda, P., Shiradkar, R., Guo, K., & Zheng, G. (2014) · Optics Express · doi:10.1364/oe.22.020856 · Cited by 160
Deep-Learning-Based Image Reconstruction and Enhancement in Optical Microscopy
Haan, K. D., Rivenson, Y., Wu, Y., & Özcan, A. (2019) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2949575 · Cited by 159
Sevenfold improvement of axial resolution in 3D wide-field microscopy using two objective lenses
Gustafsson, M. G. L., Agard, D. A., & Sedat, J. W. (1995) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.205334 · Cited by 157
Super-resolution imaging of fluorescent dipoles via polarized structured illumination microscopy
Zhanghao, K., Chen, X., Liu, W., Li, M., Liu, Y., Wang, Y., Luo, S., Wang, X., Shan, C., Xie, H., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-12681-w · Cited by 156
Self-citationStructured illumination microscopy using a photonic chip
Helle, Ø. I., Dullo, F. T., Lahrberg, M., Tinguely, J.-C., Hellesø, O. G., & Ahluwalia, B. S. (2020) · Nature Photonics · doi:10.1038/s41566-020-0620-2 · Cited by 156 · cited 2×
“In 2020, Helle et al.182 proposed a chip-based SIM (cSIM) method using a photonic integrated circuit (PIC) chip to create standing wave interference patterns.”
MethodSchaefer, L. H., Schuster, D., & Schaffer, J. (2004) · Journal of Microscopy · doi:10.1111/j.0022-2720.2004.01411.x · Cited by 156
Structured illumination microscopy based on principal component analysis
Qian, J., Cao, Y., Bi, Y., Wu, H., Liu, Y., Chen, Q., & Zuo, C. (2023) · eLight · doi:10.1186/s43593-022-00035-x · Cited by 154 · cited 2×
“In 2022, Qian et al.99,100 introduced principal component analysis (PCA) into SIM for the first time to identify the frequency vectors and pattern phases of the illumination pattern (Fig.”
MethodLateral resolution enhancement with standing evanescent waves
Cragg, G. E., & So, P. T. C. (2000) · Optics Letters · doi:10.1364/ol.25.000046 · Cited by 147
Ingaramo, M., York, A. G., Wawrzusin, P. J., Milberg, O., Hong, A., Weigert, R., Shroff, H., & Patterson, G. H. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1314447111 · Cited by 145
Image formation in structured illumination wide-field fluorescence microscopy
Karadaglić, D., & Wilson, T. (2008) · Micron · doi:10.1016/j.micron.2008.01.017 · Cited by 145
Dynamic super-resolution structured illumination imaging in the living brain
Turcotte, R., Liang, Y., Tanimoto, M., Zhang, Q., Li, Z., Koyama, M., Betzig, E., & Ji, N. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1819965116 · Cited by 143
Saturated patterned excitation microscopy with two-dimensional excitation patterns
Heintzmann, R. (2003) · Micron · doi:10.1016/s0968-4328(03)00053-2 · Cited by 141
Three-dimensional structured illumination microscopy with enhanced axial resolution
Li, X., Wu, Y., Su, Y. P., Rey‐Suarez, I., Matthaeus, C., Updegrove, T. B., Wei, Z., Zhang, L., Sasaki, H., Li, Y., et al. (2023) · Nature Biotechnology · doi:10.1038/s41587-022-01651-1 · Cited by 135 · cited 1×
“In 2022, Li et al.(48) placed a mirror directly opposite the sample and realized four-beam interference (Fig.”
BackgroundActiveStereoNet: End-to-End Self-supervised Learning for Active Stereo Systems
Zhang, Y., Khamis, S., Rhemann, C., Valentin, J., Kowdle, A., Tankovich, V., Schoenberg, M., Izadi, S., Funkhouser, T. A., & Fanello, S. (2018) · Lecture notes in computer science · doi:10.1007/978-3-030-01237-3_48 · Cited by 132
Winter, P. W., York, A. G., Nogare, D. D., Ingaramo, M., Christensen, R. P., Chitnis, A. B., Patterson, G. H., & Shroff, H. (2014) · Optica · doi:10.1364/optica.1.000181 · Cited by 129
Bayesian Estimation for Optimized Structured Illumination Microscopy
Orieux, F., Sepulveda, E. S., Loriette, V., Dubertret, B., & Olivo‐Marín, J. (2011) · IEEE Transactions on Image Processing · doi:10.1109/tip.2011.2162741 · Cited by 126
Multiple signal classification algorithm for super-resolution fluorescence microscopy
Agarwal, K., & Macháň, R. (2016) · Nature Communications · doi:10.1038/ncomms13752 · Cited by 126
Richardson–Lucy Deconvolution as a General Tool for Combining Images with Complementary Strengths
Ingaramo, M., York, A. G., Hoogendoorn, E., Postma, M., Shroff, H., & Patterson, G. H. (2014) · ChemPhysChem · doi:10.1002/cphc.201300831 · Cited by 121
Phase-shift estimation in sinusoidally illuminated images for lateral superresolution
Shroff, S. A., Fienup, J. R., & Williams, D. R. (2009) · Journal of the Optical Society of America A · doi:10.1364/josaa.26.000413 · Cited by 120 · cited 2×
“Shroff et al.92,93 proposed a Fourier domain phase of the peak (POP) estimation method without prior knowledge of the phase shifts, which is suitable for livecell imaging, as shown in Fig.”
MethodWicker, K. (2013) · Optics Express · doi:10.1364/oe.21.024692 · Cited by 119
Super-resolved live-cell imaging using random illumination microscopy
Mangeat, T., Labouesse, S., Allain, M., Negash, A., Martin, E., Guénolé, A., Poincloux, R., Estibal, C., Bouissou, A., Cantaloube, S., et al. (2021) · Cell Reports Methods · doi:10.1016/j.crmeth.2021.100009 · Cited by 117
Shah, Z. H., Muller, M. W., Wang, T.-C., Scheidig, P. M., Schneider, A., Schüttpelz, M., Huser, T. R., & Schenck, W. (2021) · Photonics Research · doi:10.1364/prj.416437 · Cited by 107
Wang, Z., Zhao, T., Hao, H., Cai, Y., Feng, K., Yun, X., Liang, Y., Wang, S., Sun, Y., Oh, K., et al. (2022) · Advanced Photonics · doi:10.1117/1.ap.4.2.026003 · Cited by 105 · cited 6×
“In 2019, Wang et al.78 proposed a Fourier bandpass filtering algorithm to reconstruct optical section images by shifting the in-focus signals to the +1st order in the Fourier domain.”
MethodInfluentialMin, J., Jang, J., Keum, D., Ryu, S., Choi, C., Jeong, K., & Ye, J. C. (2013) · Scientific Reports · doi:10.1038/srep02075 · Cited by 98 · cited 2×
“In 2013, Min et al.(155) presented another speckle illumination microscopy by implementing a multiple sparse Bayesian learning (M-SBL) algorithm(156).”
Real time 3D fluorescence microscopy by two beam interference illumination
Neil, M. A. A., Juskaitis, R., & Wilson, T. (1998) · Optics Communications · doi:10.1016/s0030-4018(98)00210-7 · Cited by 97 · cited 2×
“To remove the out-of-focus information and obtain the whole structure of a 3D sample, Neil et al.(15,23) introduced the OS-SIM algorithm.”
MethodRapid nonlinear image scanning microscopy
Gregor, I., Spiecker, M., Petrovsky, R., Großhans, J., Ros, R., & Enderlein, J. (2017) · Nature Methods · doi:10.1038/nmeth.4467 · Cited by 96 · cited 2×
“In addition, in 2017, Gregor et al.(173) improved the frame rate of 2P-SIM to 30 Hz by incorporating nonlinear excitation and a single resonant scanner.”
BackgroundStructured illumination microscopy with unknown patterns and a statistical prior
Yeh, L.-H., Tian, L., & Waller, L. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.000695 · Cited by 94
Christensen, C. N., Ward, E., Lü, M., Lió, P., & Kaminski, C. F. (2021) · Biomedical Optics Express · doi:10.1364/boe.414680 · Cited by 93
Ströhl, F., & Kaminski, C. F. (2015) · Methods and Applications in Fluorescence · doi:10.1088/2050-6120/3/1/014002 · Cited by 93 · cited 2×
“In 2015, Ströhl et al.161 presented a jRL-MSIM plan to suppress out-of-focus signals.”
BackgroundHigh-resolution image reconstruction in fluorescence microscopy with patterned excitation
Heintzmann, R., & Benedetti, P. A. (2006) · Applied Optics · doi:10.1364/ao.45.005037 · Cited by 93 · cited 4×
“Heintzmann et al.30 discussed and analysed these three strategies based on a regular array of point illumination patterns.”
BackgroundInfluentialFast structured illumination microscopy via deep learning
Ling, C., Zhang, C., Wang, M., Meng, F., Du, L., & Yuan, X. (2020) · Photonics Research · doi:10.1364/prj.396122 · Cited by 90
Fast widefield imaging of neuronal structure and function with optical sectioning in vivo
Li, Z., Zhang, Q., Chou, S., Newman, Z., Turcotte, R., Natan, R. G., Dai, Q., Isacoff, E. Y., & Ji, N. (2020) · Science Advances · doi:10.1126/sciadv.aaz3870 · Cited by 90
Self-citationSuperresolution via structured illumination quantum correlation microscopy
Classen, A., von Zanthier, J., Scully, M. O., & Agarwal, G. S. (2017) · Optica · doi:10.1364/optica.4.000580 · Cited by 90
Structured illumination microscopy with noise-controlled image reconstructions
Smith, C., Slotman, J. A., Schermelleh, L., Chakrova, N., Hari, S., Vos, Y., HAGEN, K., Muller, M. W., van Cappellen, W. A., Houtsmuller, A. B., et al. (2021) · Nature Methods · doi:10.1038/s41592-021-01167-7 · Cited by 89 · cited 2×
“In 2021, Smith et al.(148) presented a physically realistic noise model and provided three complementary reconstruction methods: true-Wiener-filtered SIM, flat-noise SIM, and notchfiltered SIM.”
MethodImage reconstruction for structured-illumination microscopy with low signal level
Chu, K., McMillan, P. J., Smith, Z. J., Yin, J., Atkins, J., Goodwin, P. C., Wachsmann‐Hogiu, S., & Lane, S. M. (2014) · Optics Express · doi:10.1364/oe.22.008687 · Cited by 86 · cited 2×
“For example, in 2014, Chu et al.(112) introduced a total variation (TV) constraint for SIM reconstruction.”
BackgroundBiggs, D. S. C. (2010) · Current Protocols in Cytometry · doi:10.1002/0471142956.cy1219s52 · Cited by 86
fastSIM: a practical implementation of fast structured illumination microscopy
Lu-Walther, H.-W., Kielhorn, M., Förster, R., Jost, A., Wicker, K., & Heintzmann, R. (2015) · Methods and Applications in Fluorescence · doi:10.1088/2050-6120/3/1/014001 · Cited by 86
Wang, Y., Yu, Z., Cahoon, C. K., Parmely, T. J., Thomas, N. E., Unruh, J. R., Slaughter, B. D., & Hawley, R. S. (2018) · Nature Protocols · doi:10.1038/s41596-018-0023-8 · Cited by 82 · cited 6×
“In 2019, Wang et al.78 proposed a Fourier bandpass filtering algorithm to reconstruct optical section images by shifting the in-focus signals to the +1st order in the Fourier domain.”
MethodInfluentialAyuk, R., Giovannini, H., Jost, A., Mudry, E., Girard, J., Mangeat, T., Sandeau, N., Heintzmann, R., Wicker, K., Belkebir, K., et al. (2013) · Optics Letters · doi:10.1364/ol.38.004723 · Cited by 81
Line scan - structured illumination microscopy super-resolution imaging in thick fluorescent samples
Mandula, O., Kielhorn, M., Wicker, K., Krampert, G., Kleppe, I. C., & Heintzmann, R. (2012) · Optics Express · doi:10.1364/oe.20.024167 · Cited by 80
Lin, R., Kipreos, E. T., Zhu, J., Khang, C. H., & Kner, P. (2021) · Nature Communications · doi:10.1038/s41467-021-23449-6 · Cited by 79 · cited 2×
“Furthermore, to reduce artifacts resulting from optical aberrations and enable 3D-SIM imaging in thick tissues, Lin et al.105 proposed the AO-3DSIM system, which combines adaptive optics with 3D-SIM and processes 3D-stack data using the generalized Wiener filtering method.”
MethodFluorescence diffuse optical tomography using the split Bregman method
Abascal, J., Chamorro-Servent, J., Aguirre, J., Arridge, S., Correia, T., Ripoll, J., Vaquero, J. J., & Desco, M. (2011) · Medical Physics · doi:10.1118/1.3656063 · Cited by 76
Enhanced resolution through thick tissue with structured illumination and adaptive optics
Thomas, B. A., Wolstenholme, A. J., Chaudhari, S. N., Kipreos, E. T., & Kner, P. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.2.026006 · Cited by 71
SIMToolbox: a MATLAB toolbox for structured illumination fluorescence microscopy
Křížek, P., Lukeš, T., Ovesný, M., Fliegel, K., & Hagen, G. M. (2015) · Bioinformatics · doi:10.1093/bioinformatics/btv576 · Cited by 71
Lukeš, T., Křížek, P., Švindrych, Z., Benda, J., Ovesný, M., Fliegel, K., Klíma, M., & Hagen, G. M. (2014) · Optics Express · doi:10.1364/oe.22.029805 · Cited by 71 · cited 2×
“Lukeš et al.113 proposed a SIM method based on the maximum a posteriori (MAP) probability.”
MethodMulti-color live-cell super-resolution volume imaging with multi-angle interference microscopy
Chen, Y., Liu, W., Zhang, Z., Zheng, C., Huang, Y., Cao, R., Zhu, D., Xu, L., Zhang, M., Zhang, Y.-H., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-07244-4 · Cited by 68
Self-citationIncoherent Fourier ptychographic photography using structured light
Dong, S., Nanda, P., Guo, K., Liao, J. B., & Zheng, G. (2015) · Photonics Research · doi:10.1364/prj.3.000019 · Cited by 65
Jost, A., Tolstik, E., Feldmann, P., Wicker, K., Sentenac, A., & Heintzmann, R. (2015) · PLoS ONE · doi:10.1371/journal.pone.0132174 · Cited by 65 · cited 2×
“For example, Jost et al.168 proposed the thick slice blind-SIM algorithm, which considers several additional planes to collect out-of-focus light and processes monofocal layer data to bridge 2D- and 3DSIM reconstructions.”
BackgroundSpeed limits of structured illumination microscopy
Ströhl, F., & Kaminski, C. F. (2017) · Optics Letters · doi:10.1364/ol.42.002511 · Cited by 64
Cao, R., Li, Y., Chen, X., Ge, X., Li, M., Guan, M., Hou, Y., Fu, Y., Xu, X., Leterrier, C., et al. (2023) · Nature Methods · doi:10.1038/s41592-023-01958-0 · Cited by 63
Self-citationDeconvolution methods for structured illumination microscopy
Chakrova, N., Rieger, B., & Stallinga, S. (2016) · Journal of the Optical Society of America A · doi:10.1364/josaa.33.000b12 · Cited by 61 · cited 2×
“Later, Chakrova et al.162 compared the piFP and jRL algorithms by formulating a generalized maximum likelihood estimation (MLE).”
MethodWang, Z., Zhao, T., Cai, Y.-A., Zhang, J., Hao, H., Liang, Y., Wang, S., Sun, Y., Chen, T., Bianco, P. R., et al. (2023) · The Innovation · doi:10.1016/j.xinn.2023.100425 · Cited by 61
Resolution doubling with a reduced number of image acquisitions
Dong, S., Liao, J. B., Guo, K., Bian, L., Suo, J., & Zheng, G. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.002946 · Cited by 61
Image recombination transform algorithm for superresolution structured illumination microscopy
Zhou, X. W., Lei, M., Dan, D., Yao, B., Yang, Y., Qian, J., Chen, G., & Bianco, P. R. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.096009 · Cited by 58 · cited 3×
“In 2016, Zhou et al.(96) proposed an image recombination transform (IRT) algorithm (Fig.”
BackgroundSahl, S. J., Balzarotti, F., Keller‐Findeisen, J., Leutenegger, M., Westphal, V., Egner, A., Lavoie‐Cardinal, F., Chmyrov, A., Grotjohann, T., & Jakobs, S. (2016) · Science · doi:10.1126/science.aad7983 · Cited by 57
Joint Reconstruction Strategy for Structured Illumination Microscopy With Unknown Illuminations
Labouesse, S., Negash, A., Idier, J., Bourguignon, S., Mangeat, T., Liu, P., Sentenac, A., & Allain, M. (2017) · IEEE Transactions on Image Processing · doi:10.1109/tip.2017.2675200 · Cited by 55
Construction of an instant structured illumination microscope
Curd, A., Cleasby, A. J., Makowska, K., York, A. G., Shroff, H., & Peckham, M. (2015) · Methods · doi:10.1016/j.ymeth.2015.07.012 · Cited by 54
Signal, noise and resolution in linear and nonlinear structured‐illumination microscopy
Ingerman, E., London, R. A., Heintzmann, R., & GUSTAFSSON, M. G. L. (2018) · Journal of Microscopy · doi:10.1111/jmi.12753 · Cited by 53
A Frequency Domain SIM Reconstruction Algorithm Using Reduced Number of Images
Lal, A., Shan, C., Zhao, K., Liu, W., Huang, X., Zong, W., Chen, L., & Xi, P. (2018) · IEEE Transactions on Image Processing · doi:10.1109/tip.2018.2842149 · Cited by 51 · cited 3×
“However, in 2018, Lal et al.(126) found only approximately a 1.”
BackgroundInfluentialSelf-citationSingle-shot optical sectioning using polarization-coded structured illumination
Wicker, K., & Heintzmann, R. (2010) · Journal of Optics · doi:10.1088/2040-8978/12/8/084010 · Cited by 51
Fast reconstruction algorithm for structured illumination microscopy
Tu, S., Liu, Q., Liu, X., Liu, W., Zhang, Z., Luo, T., Kuang, C., Liu, X., & Hao, X. (2020) · Optics Letters · doi:10.1364/ol.387888 · Cited by 47 · cited 1×
“In contrast to these methods, Tu et al.(141) developed a parameter-free algorithm called shifting phase SIM (SPSIM), which directly reconstructs superresolution images in the spatial domain (Fig.”
ResultZhang, H., Zhao, M., & Peng, L. (2011) · Optics Express · doi:10.1364/oe.19.024783 · Cited by 46
Deep learning optical-sectioning method
Zhang, X., Chen, Y., Ning, K., Zhou, C., Han, Y., Gong, H., & Yuan, J. (2018) · Optics Express · doi:10.1364/oe.26.030762 · Cited by 42
Inverse matrix based phase estimation algorithm for structured illumination microscopy
Cao, R., Chen, Y., Liu, W., Zhu, D., Kuang, C., Xu, Y., & Liu, X. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.005037 · Cited by 42 · cited 3×
“To address these issues, Cao et al.(98) proposed a noniterative phase estimation method based on an inverse matrix by incorporating extra matrices into the phase estimation algorithm.”
MethodInfluentialSelf-citationShroff, S. A., Fienup, J. R., & Williams, D. R. (2010) · Journal of the Optical Society of America A · doi:10.1364/josaa.27.001770 · Cited by 42
Rapid Image Reconstruction of Structured Illumination Microscopy Directly in the Spatial Domain
Dan, D., Wang, Z., Zhou, X. W., Lei, M., Zhao, T., Qian, J., Yu, X., Yan, S., Min, J., Bianco, P. R., et al. (2021) · IEEE photonics journal · doi:10.1109/jphot.2021.3053110 · Cited by 40 · cited 2×
“Inspired by the series expansion of a function in mathematics136, Dan et al.138 proposed another SDR method by computing the coefficient matrix (Fig.”
MethodMotion-resistant structured illumination microscopy based on principal component analysis
Lyu, J., Qian, J., Xu, K., Huang, Y., & Zuo, C. (2022) · Optics Letters · doi:10.1364/ol.480330 · Cited by 40
Chai, C., Cheng, C., Liu, X., et al. (2021) · Optics Express · doi:10.1364/oe.415210 · Cited by 39
3D Structured Illumination Microscopy via Channel Attention Generative Adversarial Network
Qiao, C. F., Chen, X., Zhang, S., Li, D., Guo, Y., Dai, Q., & Li, D. (2021) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2021.3060762 · Cited by 37
Self-citationFast and Lightweight Network for Single Frame Structured Illumination Microscopy Super-Resolution
Cheng, X., Li, J., Qiang, D., Fu, Z., & Yang, J. J. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3161721 · Cited by 36
Liu, W., Liu, Q., Zhang, Z., Han, Y., Kuang, C., Xu, L., Yang, H., & Liu, X. (2019) · Optics Express · doi:10.1364/oe.27.007237 · Cited by 36
Deep learning-based single-shot structured illumination microscopy
Zhang, Q., Chen, J., Li, J., Bo, E., Jiang, H.-M., Lü, X., Zhong, L., & Tian, J. (2022) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2022.107066 · Cited by 34
Xue, Y., & So, P. T. C. (2018) · Optics Express · doi:10.1364/oe.26.020920 · Cited by 34 · cited 2×
“In 2018, Xue et al.75 developed a 3D SI-STED microscope that uses five coherent beams to interfere and generate a 3D grid depletion pattern (Fig.”
BackgroundStructured illumination microscopy with interleaved reconstruction (SIMILR)
Ma, Y., Li, D., Smith, Z. J., Li, D., & Chu, K. (2017) · Journal of Biophotonics · doi:10.1002/jbio.201700090 · Cited by 33 · cited 1×
“In 2017, Ma et al.(128) proposed the combination of SIM with an interleaved reconstruction strategy (SIMILR) to maximize the use of each subframe of the acquisition series.”
MethodSelf-citationTwo‐dimensional structured illumination microscopy
Schropp, M., & Uhl, R. (2014) · Journal of Microscopy · doi:10.1111/jmi.12154 · Cited by 31
Deep learning for blind structured illumination microscopy
Xypakis, E., Gosti, G., Giordani, T., Santagati, R., Ruocco, G., & Leonetti, M. (2022) · Scientific Reports · doi:10.1038/s41598-022-12571-0 · Cited by 30
Nonsmooth convex optimization for structured illumination microscopy image reconstruction
Boulanger, J., Pustelnik, N., Condat, L., Sengmanivong, L., & Piolot, T. (2018) · Inverse Problems · doi:10.1088/1361-6420/aaccca · Cited by 28 · cited 2×
“In the same year, Boulanger et al.116 proposed a nonsmooth convex optimization method for SIM reconstruction.”
Answering some questions about structured illumination microscopy
Manton, J. D. (2022) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2021.0109 · Cited by 27 · cited 2×
“In 2021, Manton et al.137 reported an equivalent AM signal demodulation method that used the structured illumination pattern as the carrier signal, the sample as the message signal, and the recorded data as the product of these two, i.e., the AM signal.”
MethodJohnson, K. A., & Hagen, G. M. (2020) · GigaScience · doi:10.1093/gigascience/giaa035 · Cited by 25
Improving axial resolution in Structured Illumination Microscopy using deep learning
Boland, M. A., Cohen, E. A. K., Flaxman, S. R., & Neil, M. A. A. (2021) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2020.0298 · Cited by 24 · cited 2×
“These include a transfer learning-based generality end-to-end deep residual neural network ML-SIM191, a custom convolutional neural network architecture BS-CNN for blind-SIM reconstruction192, and a modified residual channel attention network (RCAN)193 by Boland et al.194.”
MethodSarkar, S., Samanta, K., & Joseph, J. (2020) · Optics Express · doi:10.1364/oe.384987 · Cited by 23
Single-scan HiLo with line-illumination strategy for optical section imaging of thick tissues
Qiao, W., Jin, R., Luo, T., Li, Y., Fan, G., Luo, Q., & Yuan, J. (2021) · Biomedical Optics Express · doi:10.1364/boe.419377 · Cited by 19
Three-dimensional imaging of biological specimens with standing wave fluorescence microscopy
Bailey, B., Krishnamurthi, V., Farkas, D. L., Taylor, D. L., & Lanni, F. (1994) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.172101 · Cited by 19
Adaptable, illumination patterning light sheet microscopy
Power, R. M., & Huisken, J. (2018) · Scientific Reports · doi:10.1038/s41598-018-28036-2 · Cited by 18
Improvement in Resolution of Multiphoton Scanning Structured Illumination Microscopy via Harmonics
Wang, L., Zheng, X., Zhou, J., Wang, M., Chen, J., Zeng, Y., Xu, G., Wang, Y., Qiu, H., Shao, Y., et al. (2022) · Engineering · doi:10.1016/j.eng.2021.12.010 · Cited by 16 · cited 6×
“In 2019, Wang et al.78 proposed a Fourier bandpass filtering algorithm to reconstruct optical section images by shifting the in-focus signals to the +1st order in the Fourier domain.”
MethodInfluentialTotal variation and spatial iteration-based 3D structured illumination microscopy
Cai, M., Zhu, H., Sun, Y., Yin, L., Xu, F., Wu, H., Hao, X., Zhou, R., Kuang, C., & Liu, X. (2022) · Optics Express · doi:10.1364/oe.451190 · Cited by 13
Single-shot optical sectioning microscopy based on structured illumination
Fu, Z., Chen, J., Liu, G., & Chen, S. (2022) · Optics Letters · doi:10.1364/ol.451267 · Cited by 13 · cited 1×
“In 2022, Fu et al.(44) reported a 3D-resolved single-shot SIM system based on a digital micromirror device (DMD), a galvanometric mirror, and the HiLo algorithm.”
The largest isoform of Ankyrin-G is required for lattice structure of the axon initial segment
Wang, Y., Guan, M., Wang, H., Li, Y., Zhanghao, K., Xi, P., & Zhang, Y. (2021) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2021.09.017 · Cited by 12
Self-citationTotal internal reflection fluorescence pattern-illuminated Fourier ptychographic microscopy
Liu, Q., Chen, Y., Liu, W., Han, Y., Cao, R., Zhang, Z., Kuang, C., & Liu, X. (2019) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2019.06.023 · Cited by 8
Self-citationHou, Y., Wang, W., Fu, Y., Ge, X., Li, M., & Xi, P. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.03.02.530744 · Cited by 8 · cited 2×
“Recently, Hou et al.(122) developed an MRA deconvolution algorithm for fluorescence images, which uses framelet and curvelet domain sparsity to regularize the solution.”
MethodSelf-citationSIM reconstruction framework for high-speed multi-dimensional super-resolution imaging
Zeng, H., Liu, G., & Zhao, R. (2022) · Optics Express · doi:10.1364/oe.450136 · Cited by 6 · cited 2×
“In 2022, Zeng et al.127 introduced polarization modulation to the frame reduction imaging model, proposing a complete and versatile imaging model called PRSIM.”
Glucose increases the length and spacing of the lattice structure of the axon initial segment
Wang, Y., Guan, M., Zhang, Y., Zhanghao, K., & Xi, P. (2022) · Microscopy Research and Technique · doi:10.1002/jemt.24122 · Cited by 4
Self-citation
Cited by
Quantitative phase imaging based on holography: trends and new perspectives
Huang, Z., & Cao, L. (2024) · Light: Science & Applications · doi:10.1038/s41377-024-01453-x · Cited by 277
Bertoli, G., Phadke, K., Cospito, A., Rizk, J. A., Zhang, M., Miliotou, E., Cammer, M., Deng, Y., Mezzano, V., Alu, M., et al. (2025) · doi:10.1101/2025.10.22.682160 · Cited by 2
(2026) · doi:10.1161/jaha.125.047447 · Cited by 2
Metadata
- Authors
- Chen, X., Zhong, S., Hou, Y., Cao, R., Wang, W., Li, D., Dai, Q., Kim, D., & Xi, P.
- Venue
- Light: Science & Applications
- Published
- 2023-07-12
- Volume
- 12
- Issue
- 1
- Pages
- 172-172
- ISSN
- 2047-7538 (ISSN-L)
- OpenAlex
- W4383999302
- Cited by
- 229
- References
- 158
- FWCI
- 25.49
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.