Membrane-free culture and real-time barrier integrity assessment of perfused intestinal epithelium tubes
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
In vitro models that better reflect in vivo epithelial barrier (patho-)physiology are urgently required to predict adverse drug effects. Here we introduce extracellular matrix-supported intestinal tubules in perfused microfluidic devices, exhibiting tissue polarization and transporter expression. Forty leak-tight tubules are cultured in parallel on a single plate and their response to pharmacological stimuli is recorded over 125 h using automated imaging techniques. A study comprising 357 gut tubes is performed, of which 93% are leak tight before exposure. EC 50 -time curves could be extracted that provide insight into both concentration and exposure time response. Full compatibility with standard equipment and user-friendly operation make this Organ-on-a-Chip platform readily applicable in routine laboratories.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“A more recent study demonstrated real-time barrier integrity assessment capabilities in a membrane-free culture of perfused intestinal epithelium tubes.38”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [38]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fiji: an open-source platform for biological-image analysis
Schindelin, J., Arganda-Carreras, I., Frise, E., Kaynig, V., Longair, M., Pietzsch, T., Preibisch, S., Rueden, C., Saalfeld, S., Schmid, B., et al. (2012) · Nature Methods · doi:10.1038/nmeth.2019 · Cited by 66,890
Physiology of the Gastrointestinal Tract
(2006) · Elsevier eBooks · doi:10.1016/b978-0-12-088394-3.x5000-4 · Cited by 4,597
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817
Hydrogels as extracellular matrix mimics for 3D cell culture
Tibbitt, M. W., & Anseth, K. S. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22361 · Cited by 2,727
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Weaver, V. M., Petersen, O. W., Wang, F., Larabell, C. A., Briand, P., Damsky, C., & Bissell, M. J. (1997) · The Journal of Cell Biology · doi:10.1083/jcb.137.1.231 · Cited by 1,483
Kim, H. J., Li, H., Collins, J. J., & Ingber, D. E. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1522193112 · Cited by 922
A microfluidics-based in vitro model of the gastrointestinal human–microbe interface
Shah, P., Fritz, J. V., Glaab, E., Desai, M. S., Greenhalgh, K., Frachet, A., Niegowska, M., Estes, M., Jäger, C., Seguin-Devaux, C., et al. (2016) · Nature Communications · doi:10.1038/ncomms11535 · Cited by 660
Chantret, I., Barbat, A., Dussaulx, E., Brattain, M. G., & Zweibaum, A. (1988) · PubMed · Cited by 536
Microfluidic 3D cell culture: from tools to tissue models
van Duinen, V., Trietsch, S. J., Joore, J., Vulto, P., & Hankemeier, T. (2015) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2015.05.002 · Cited by 500
Self-citationStaurosporine induces apoptosis through both caspase-dependent and caspase-independent mechanisms
Belmokhtar, C. A., Hillion, J., & Ségal-Bendirdjian, E. (2001) · Oncogene · doi:10.1038/sj.onc.1204436 · Cited by 474
Matsui, H., Shimokawa, O., Kaneko, T., Nagano, Y., Rai, K., & Hyodo, I. (2011) · Journal of Clinical Biochemistry and Nutrition · doi:10.3164/jcbn.10-79 · Cited by 268
Phaseguides: a paradigm shift in microfluidic priming and emptying
Vulto, P., Podszun, S., Meyer, P., Hermann, C., Manz, A., & Urban, G. A. (2011) · Lab on a Chip · doi:10.1039/c0lc00643b · Cited by 222
Self-citationMicrofluidic titer plate for stratified 3D cell culture
Trietsch, S. J., Israëls, G. D., Joore, J., Hankemeier, T., & Vulto, P. (2013) · Lab on a Chip · doi:10.1039/c3lc50210d · Cited by 189
Self-citationEpithelial cell–cell junctions and plasma membrane domains
Giepmans, B. N. G., & van IJzendoorn, S. C. D. (2009) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2008.07.015 · Cited by 170
Lever, J. E. (1979) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.76.3.1323 · Cited by 154
High-throughput compound evaluation on 3D networks of neurons and glia in a microfluidic platform
Wevers, N. R., van Vught, R., Wilschut, K. J., Nicolas, A., Chiang, C., Lanz, H. L., Trietsch, S. J., Joore, J., & Vulto, P. (2016) · Scientific Reports · doi:10.1038/srep38856 · Cited by 146
Self-citationAspirin induces gastric epithelial barrier dysfunction by activating p38 MAPK via claudin-7
Oshima, T., Miwa, H., & Joh, T. (2008) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00157.2008 · Cited by 129
An end-user perspective on Organ-on-a-Chip: Assays and usability aspects
Junaid, A., Mashaghi, A., Hankemeier, T., & Vulto, P. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.02.002 · Cited by 123
Self-citationLiang, T. W., DeMarco, R. A., Mrsny, R. J., Gurney, A., Gray, A., Hooley, J., Aaron, H. L., Huang, A., Klassen, T., Tumas, D. B., et al. (2000) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.2000.279.6.c1733 · Cited by 108
Hardell, L., Ohlson, C., & Fredrikson, M. G. (1997) · International Journal of Cancer · doi:10.1002/(sici)1097-0215(19971210)73:6<875::aid-ijc19>3.0.co;2-3 · Cited by 67
Effect of aspirin on cell proliferation and differentiation of colon adenocarcinoma Caco-2 cells
Ricchi, P., Pignata, S., Popolo, A. D., Memoli, A., Apicella, A., Zarrilli, R., & Acquaviva, A. M. (1997) · International Journal of Cancer · doi:10.1002/(sici)1097-0215(19971210)73:6<880::aid-ijc20>3.0.co;2-7 · Cited by 64
Pfister, A. B., Wood, R. C., Salas, P. J. I., Zea, D. L., & Palau, V. E. (2010) · Journal of Cellular Biochemistry · doi:10.1002/jcb.22754 · Cited by 8
Cited by
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Homeostatic mini-intestines through scaffold-guided organoid morphogenesis
Nikolaev, M., Mitrofanova, O., Broguiere, N., Geraldo, S., Dutta, D., Tabata, Y., Elci, B., Brandenberg, N., Kolotuev, I., Gjorevski, N., et al. (2020) · Nature · doi:10.1038/s41586-020-2724-8 · Cited by 755
Microfluidic Organ-on-a-Chip Models of Human Intestine
Bein, A., Shin, W., Jalili-Firoozinezhad, S., Park, M. H., Sontheimer-Phelps, A., Tovaglieri, A., Chalkiadaki, A., Kim, H. J., & Ingber, D. E. (2018) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2017.12.010 · Cited by 625
Tubuloids derived from human adult kidney and urine for personalized disease modeling
Schutgens, F., Rookmaaker, M. B., Margaritis, T., Rios, A., Ammerlaan, C., Jansen, J., Gijzen, L., Vormann, M., Vonk, A., Viveen, M., et al. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0048-8 · Cited by 449
Self-citationWevers, N. R., Kasi, D. G., Gray, T., Wilschut, K. J., Smith, B., van Vught, R., Shimizu, F., Sano, Y., Kanda, T., Marsh, G., et al. (2018) · Fluids and Barriers of the CNS · doi:10.1186/s12987-018-0108-3 · Cited by 353
Self-citation
Metadata
- Authors
- Trietsch, S. J., Naumovska, E., Kurek, D., Setyawati, M. C., Vormann, M. K., Wilschut, K. J., Lanz, H. L., Nicolas, A., Ng, C. P., Joore, J., Kustermann, S., Roth, A., Hankemeier, T., Moisan, A., & Vulto, P.
- Affiliations
- Mimetas (Netherlands) (NL)
- F. Hoffmann-La Roche AG (CH)
- Leiden University (NL)
- Corresponding author
- Vulto, Paul
- ORCID
- Venue
- Nature Communications
- Published
- 2017-08-15
- Volume
- 8
- Issue
- 1
- Pages
- 262-262
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC5557798
- OpenAlex
- W2742210001
- Cited by
- 290
- References
- 22
- Citations by year
- 2026: 15 · 2025: 31 · 2024: 42 · 2023: 34 · 2022: 35 · 2021: 41 · 2020: 36 · 2019: 25 · 2018: 29 · 2017: 2
- FWCI
- 11.32
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Nature Communications (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (acceptedVersion)
- Leiden Repository (Leiden University) (submittedVersion, other-oa)
- Leiden Repository (Leiden University) (submittedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
- Funders
- Universiteit Leiden
- Leids Universitair Medisch Centrum
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- intestinal epithelium, organ-on-a-chip, barrier integrity, leak detection, extracellular matrix, tissue polarization, transporter expression, adverse drug reactions, in vitro gut model, automated imaging
- MeSH terms
- Humans, Intestinal Mucosa, Kinetics, Cell Culture Techniques, Caco-2 Cells, Microfluidic Analytical Techniques, Lab-On-A-Chip Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.