Acoustically actuated ultra-compact NEMS magnetoelectric antennas
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
State-of-the-art compact antennas rely on electromagnetic wave resonance, which leads to antenna sizes that are comparable to the electromagnetic wavelength. As a result, antennas typically have a size greater than one-tenth of the wavelength, and further miniaturization of antennas has been an open challenge for decades. Here we report on acoustically actuated nanomechanical magnetoelectric (ME) antennas with a suspended ferromagnetic/piezoelectric thin-film heterostructure. These ME antennas receive and transmit electromagnetic waves through the ME effect at their acoustic resonance frequencies. The bulk acoustic waves in ME antennas stimulate magnetization oscillations of the ferromagnetic thin film, which results in the radiation of electromagnetic waves. Vice versa, these antennas sense the magnetic fields of electromagnetic waves, giving a piezoelectric voltage output. The ME antennas (with sizes as small as one-thousandth of a wavelength) demonstrates 1–2 orders of magnitude miniaturization over state-of-the-art compact antennas without performance degradation. These ME antennas have potential implications for portable wireless communication systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiferroic magnetoelectric composites: Historical perspective, status, and future directions
Nan, C.-W., Bichurin, M. I., Dong, S., Viehland, D., & Srinivasan, G. (2008) · Journal of Applied Physics · doi:10.1063/1.2836410 · Cited by 3,762
Physical limitations of omnidirectional antennas
(1948) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 2,235
Towards a magnetoelectric memory
Bibes, M., & Barthélémy, A. (2008) · Nature Materials · doi:10.1038/nmat2189 · Cited by 1,613
Current-induced torques in magnetic materials
Brataas, A., Kent, A. D., & Ohno, H. (2012) · Nature Materials · doi:10.1038/nmat3311 · Cited by 1,221
Fractal antennas: a novel antenna miniaturization technique, and applications
Gianvittorio, J. P., & Rahmat-Samii, Y. (2002) · IEEE Antennas and Propagation Magazine · doi:10.1109/74.997888 · Cited by 746
Piezoelectric Aluminum Nitride Vibrating Contour-Mode MEMS Resonators
Piazza, G., Stephanou, P. J., & Pisano, A. P. (2006) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2006.886012 · Cited by 639
High-density magnetoresistive random access memory operating at ultralow voltage at room temperature
Hu, J.-M., Li, Z., Chen, L.-Q., & Nan, C.-W. (2011) · Nature Communications · doi:10.1038/ncomms1564 · Cited by 470
Elastically Driven Ferromagnetic Resonance in Nickel Thin Films
Weiler, M., Dreher, L., Heeg, C., Huebl, H., Gross, R., Brandt, M. S., & Goennenwein, S. T. B. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.117601 · Cited by 468
An Extremely Low Equivalent Magnetic Noise Magnetoelectric Sensor
Wang, Y., Gray, D., Berry, D., Gao, J., Li, M., Li, J., & Viehland, D. (2011) · Advanced Materials · doi:10.1002/adma.201100773 · Cited by 388
Self-citationMagnetodielectric Substrates in Antenna Miniaturization: Potential and Limitations
Ikonen, P. M. T., Rozanov, K. N., Osipov, A. V., Alitalo, P., & Tretyakov, S. A. (2006) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2006.884303 · Cited by 240
Cited by
Introduction to spin wave computing
Mahmoud, A., Ciubotaru, F., Vanderveken, F., Chumak, A. V., Hamdioui, S., Adelmann, C., & Cotofana, S. (2020) · Journal of Applied Physics · doi:10.1063/5.0019328 · Cited by 354
Straintronics: a new trend in micro- and nanoelectronics and materials science
Bukharaev, A. A., Zvezdin, A. K., Pyatakov, A. P., & Fetisov, Y. K. (2018) · Physics-Uspekhi · doi:10.3367/ufne.2018.01.038279 · Cited by 255
A wireless millimetric magnetoelectric implant for the endovascular stimulation of peripheral nerves
Chen, J. C., Kan, P., Yu, Z., Alrashdan, F., Garcia, R., Singer, A., Lai, C. S. E., Avants, B., Crosby, S., Li, Z., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00873-7 · Cited by 231
Magnetoelectric materials for miniature, wireless neural stimulation at therapeutic frequencies
Singer, A., Dutta, S., Lewis, E., Chen, Z., Chen, J. C., Verma, N., Avants, B., Feldman, A. K., O’Malley, J., Beierlein, M., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.05.019 · Cited by 202
Magnetoelectric effect: principles and applications in biology and medicine– a review
Kopyl, S., Surmenev, R., Surmeneva, M., Fetisov, Y., & Kholkin, A. (2021) · Materials Today Bio · doi:10.1016/j.mtbio.2021.100149 · Cited by 202
“The development of a ME antenna indicated that for a given frequency, its wavelength could be five orders of magnitude shorter than the electromagnetic wavelength, thus enabling dramatic device miniaturization [176].”
BackgroundZaeimbashi, M., Nasrollahpour, M., Khalifa, A., Romano, A., Liang, X., Chen, H., Sun, N., Matyushov, A., Lin, H., Dong, C., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-23256-z · Cited by 201
Self-citationWireless power transfer based on novel physical concepts
Song, M., Jayathurathnage, P., Zanganeh, E., Krasikova, M., Smirnov, P., Belov, P., Kapitanova, P., Simovski, C., Tretyakov, S., & Krasnok, A. (2021) · Nature Electronics · doi:10.1038/s41928-021-00658-x · Cited by 190
Magnetoelectric materials and devices
Liang, X., Chen, H., & Sun, N. X. (2021) · APL Materials · doi:10.1063/5.0044532 · Cited by 184
Self-citationRecent development and status of magnetoelectric materials and devices
Cheng, Y., Peng, B., Hu, Z., Zhou, Z., & Liu, M. (2018) · Physics Letters A · doi:10.1016/j.physleta.2018.07.014 · Cited by 161
Self-citationWireless power delivery techniques for miniature implantable bioelectronics
Singer, A., & Robinson, J. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100664 · Cited by 159
Luan, L., Robinson, J. T., Aazhang, B., Chi, T., Yang, K., Li, X., Rathore, H., Singer, A., Yellapantula, S., Fan, Y., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.011 · Cited by 150
Miniature battery-free bioelectronics
Nair, V., Dalrymple, A. N., Yu, Z., Balakrishnan, G., Bettinger, C. J., Weber, D. J., Yang, K., & Robinson, J. T. (2023) · Science · doi:10.1126/science.abn4732 · Cited by 128
“Typical frequencies for inductive coupling are in the range of 1 to 13 MHz, which approaches the frequencies at which magnetic fields begin to be absorbed or reflected by the ionic fluids within the body ( 60 ).”
BackgroundTruong, B. D., Andersen, E., Casados, C., & Roundy, S. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2020.112269 · Cited by 41
Metadata
- Authors
- Nan, T., Lin, H., Gao, Y., Matyushov, A., Yu, G., Chen, H., Sun, N., Wei, S., Wang, Z., Li, M., Wang, X., Belkessam, A., Guo, R., Chen, B., Zhou, J., Qian, Z., Hui, Y., Rinaldi, M., McConney, M. E., Howe, B. M., Hu, Z., Jones, J. G., Brown, G. J., & Sun, N. X.
- Venue
- Nature Communications
- Published
- 2017-08-22
- Volume
- 8
- Issue
- 1
- Pages
- 296-296
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2743561101
- Cited by
- 484
- References
- 21
- FWCI
- 10.46
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.