A wireless millimetre-scale implantable neural stimulator with ultrasonically powered bidirectional communication
The DOI matches its Crossref record; 95 of the 95 references it cites were found in a registry or an index.
Abstract
Clinically approved neural stimulators are limited by battery requirements, as well as by their large size compared with the stimulation targets. Here, we describe a wireless, leadless and battery-free implantable neural stimulator that is 1.7 mm 3 and that incorporates a piezoceramic transducer, an energy-storage capacitor and an integrated circuit. An ultrasonic link and a hand-held external transceiver provide the stimulator with power and bidirectional communication. The stimulation protocols were wirelessly encoded on the fly, reducing power consumption and on-chip memory, and enabling protocol complexity with a high temporal resolution and low-latency feedback. Uplink data indicating whether stimulation occurs are encoded by the stimulator through backscatter modulation and are demodulated at the external transceiver. When embedded in ex vivo porcine tissue, the integrated circuit efficiently harvested ultrasonic power, decoded downlink data for the stimulation parameters and generated current-controlled stimulation pulses. When cuff-mounted and acutely implanted onto the sciatic nerve of anaesthetized rats, the device conferred repeatable stimulation across a range of physiological responses. The miniaturized neural stimulator may facilitate closed-loop neurostimulation for therapeutic interventions.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Specifically, recent studies have demonstrated the feasibility of piezoelectric,[327] near field communication (NFC),[328] and ultrasonic technologies[329] in power supply and data transmission.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [329]
In the citing paper
“Stimulation holds tremendous promise for prosthetic information feedback[86,515] and rehabilitation.[329,516,517]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [329]
In the citing paper
“Interfaces of the peripheral nerves such as the ultrasonic neural dust, StimDust, and the NeuroTalk active Utah electrode array demonstrated good performance in monitoring and activating the sciatic nerve [42], [52], [53].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [52]
Citations
Cites
Scoville, W. B. (1949) · Journal of neurosurgery · doi:10.3171/jns.1949.6.1.0065 · Cited by 7,381
Long-term suppression of tremor by chronic stimulation of the ventral intermediate thalamic nucleus
Benabid, A. L., Pollak, P., Hoffmann, D., Gervason, C., Hommel, M., Perret, J. E., de Rougemont, J., & Gao, D. M. (1991) · The Lancet · doi:10.1016/0140-6736(91)91175-t · Cited by 1,787
Ultrasound-Enhanced Systemic Thrombolysis for Acute Ischemic Stroke
Alexandrov, A. V., Molina, C. A., Grotta, J. C., Garami, Z., Ford, S. R., Alvarez-Sabin, J., Montaner, J., Saqqur, M., Demchuk, A. M., Moyé, L. A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa041175 · Cited by 1,046
Koopman, F. A., Chavan, S. S., Miljko, S., Grazio, S., Sokolovic, S., Schuurman, P. R., Mehta, A. D., Levine, Y. A., Faltys, M., Zitnik, R., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1605635113 · Cited by 1,024
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Ajiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557
Self-citationHassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501
Research works printed but not linked: 1
- Cowley, A. W. Helical electrode for nerve stimulation. US patent 8,478,428 (2013).
Cited by
Items 301–400 of 475
Transient energy storage devices for implantable medical electronics
Huang, C., Li, P., Niu, X., Wang, L., Gu, X., Chen, K., & Fan, Y. (2026) · Science China Materials · doi:10.1007/s40843-025-3648-2 · Cited by 5
A Wireless Battery-Free Implant With Optical Telemetry for In Vivo Cortical Stimulation
Benbuk, A. A., Garcia, D. P. M., Gulick, D. W., Quiñones‐Hinojosa, A., & Christen, J. B. (2024) · IEEE Sensors Letters · doi:10.1109/lsens.2024.3387370 · Cited by 5
Luo, H., Huang, L., Jiang, H., Huang, Y., & Lin, L. (2025) · IEEE Internet of Things Journal · doi:10.1109/jiot.2025.3599845 · Cited by 5
Zhang, K., Gao, G., Wang, Y., Wang, Y., Wang, G., Xiang, Y., Wu, Z., & Xiang, D. (2024) · Measurement · doi:10.1016/j.measurement.2024.115391 · Cited by 5
Zhang, M., Zhao, Z., Ma, Y., Zhang, C., Song, W., Lei, J., & Xie, C. (2023) · IEEE Solid-State Circuits Magazine · doi:10.1109/mssc.2023.3312227 · Cited by 5
A Wirelessly Powered 4-Channel Neurostimulator for Reconstructing Walking Trajectory
Takeuchi, M., Tokutake, K., Watanabe, K., Ito, N., Aoyama, T., Saeki, S., Kurimoto, S., Hirata, H., & Hasegawa, Y. (2022) · Sensors · doi:10.3390/s22197198 · Cited by 5
Magnetoeletric Backscatter Communication for Millimeter-Sized Wireless Biomedical Implants
Yu, Z., Alrashdan, F. T., Wang, W., Parker, M., Chen, X., Chen, F. Y., Woods, J. E., Chen, Z., Robinson, J. T., & Yang, K. (2023) · GetMobile Mobile Computing and Communications · doi:10.1145/3599184.3599192 · Cited by 5
Yang, S. (2021) · Journal of Sensors · doi:10.1155/2021/3134909 · Cited by 5
Non‐Surgical, In‐Stent Membrane Bioelectronics for Long‐Term Intracranial Pressure Monitoring
Lee, J., Bateman, A., Kim, M. H., Rigo, B., Kim, H., Lee, J., Choi, Y. H., Herbert, R., Lee, D. H., & Yeo, W. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202404680 · Cited by 5
Seed-inspired vehicles take flight
Helbling, E. F. (2021) · Nature · doi:10.1038/d41586-021-02490-x · Cited by 5
A sandwich pMUT for the amplification of ultrasound transmission and reception
Ruan, T., Wang, Q., Hu, Z., Li, L., Xu, Q., Liu, H., Yang, B. T., & Liu, J. (2025) · Applied Physics Letters · doi:10.1063/5.0250272 · Cited by 5
Piezoelectric-based optical modulator for miniaturized wireless medical implants
Edmunds, J. L., Sonmezoglu, S., & Maharbiz, M. M. (2022) · Optics Express · doi:10.1364/oe.474832 · Cited by 5
Self-citationChallenges in neural interface electronics: miniaturization and wireless operation
Mutlu, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00001-0 · Cited by 4
Liu, F., Habibollahi, M., Wu, Y., Neshatvar, N., Zhang, J., Zinno, C., Akouissi, O., Bernini, F., Alibrandi, L., Gabisonia, K., et al. (2024) · Bioelectronic Medicine · doi:10.1186/s42234-024-00148-3 · Cited by 4
Recent Progress of Smart Nano-Based Biosensors and their Applications in Biomedicine
Hasanzadeh, A., Azmand, H. R., Ebadati, A., Nourizadeh, H., Hashemzadeh, I., Noori, H., Seo, S. W., Aref, A. R., & Karimi, M. (2022) · NANO · doi:10.1142/s1793292022300067 · Cited by 4
MEDUSA: A Low-Cost, 16-Channel Neuromodulation Platform with Arbitrary Waveform Generation
Tala, F., & Johnson, B. C. (2020) · Electronics · doi:10.3390/electronics9050812 · Cited by 4
Self-citationA Comparative Study of Advanced Techniques for Wireless Power Transfer to Miniature Medical Implants
Hosur, S., Nugmanuly, K., & Kiani, M. (2025) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas56072.2025.11043881 · Cited by 4
Mingliang, 徐. X., Fangyuan, 李. L., Yueqi, 刘. L., Jinhui, 张. Z., Yazhou, 师. S., & Fei, 何. H. (2023) · Chinese Journal of Lasers · doi:10.3788/cjl221482 · Cited by 4
Vickram, A. S., Infant, S. S., Saravanan, A., Mathan, M. C. M., Gulothungan, G., & Chopra, H. (2025) · Annals of Medicine and Surgery · doi:10.1097/ms9.0000000000003622 · Cited by 4
Zou, Y., Liao, H.-C., Wang, W., Kim, W., Su, Y., Robinson, J. T., & Yang, K. (2025) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2025.3617217 · Cited by 4
Sundaram, V., Infant, S. S., Saravanan, A., Bhavani, S. B., Gulothungan, G., Arora, S., & Chopra, H. (2025) · Annals of Medicine and Surgery · doi:10.1097/ms9.0000000000003610 · Cited by 4
Saccher, M., Lolla, S. S., Kawasaki, S., & Dekker, R. H. (2022) · IEEE International Ultrasonics Symposium · doi:10.1109/ius54386.2022.9957652 · Cited by 4
State-of-the-Art Technology on Highly Miniaturized Free-Floating Neural Implants
Khalifa, A., & Etienne‐Cummings, R. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_114 · Cited by 3
Evaluation of a Miniature, Injectable, Wireless Stimulator to Treat Obstructive Sleep Apnea
Fuglevand, A. J., Bailey, E. F., & Makansi, T. (2024) · Neuromodulation Technology at the Neural Interface · doi:10.1016/j.neurom.2024.11.009 · Cited by 3
Wireless Bioelectronic Devices Driven by Deep Red Light
Jakešová, M. (2021) · Linköping studies in science and technology. Dissertations · doi:10.3384/diss.diva-171846 · Cited by 3
Ultrasonic Wireless Neural Recording and Stimulation Interfaces
Sonmezoglu, S., Shen, K., Carmena, J. M., & Maharbiz, M. M. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_10 · Cited by 3
Self-citationAn in-body networking system for communication between wearable and implantable therapeutics
Ghanim, R. W., Lee, Y. J., Byun, G., Jackson, J. M., Ding, J. Z., Park, J., Bibidakis, M., Feller, E., Kim, E., Aygun, D., et al. (2026) · Science · doi:10.1126/science.adz5300 · Cited by 3
Ultra-Miniaturised CMOS Current Driver for Wireless Biphasic Intracortical Microstimulation
Barbruni, G. L., Ros, P. M., Demarchi, D., Carrara, S., & Ghezzi, D. (2022) · International Conference on Modern Circuits and Systems Technologies · doi:10.1109/mocast54814.2022.9837681 · Cited by 3
Bio-integrated μBots with overtone ultrawideband magnetoelectric antennas for wireless telemetry
Baghini, M. S., Armada‐Moreira, A., Clemente, A. D., Mukherjee, D., Ofiare, A., Harwell, J. R., Dysko, M. F., Benetti, L., Bolster, D., Mazón‐Maldonado, L., et al. (2026) · Science Advances · doi:10.1126/sciadv.aec7011 · Cited by 3
Kim, Y., Lee, J., Kil, J., Kim, D. J., Jeong, T., & Lee, B. (2026) · Biomedical Engineering Letters · doi:10.1007/s13534-026-00564-1 · Cited by 3
Advances in Wearable Bioimaging
Chen, J., Yin, J., Liu, Y., Kulkarni, N., Saito, E., Saucedo, B. J., Young, M., & Chen, J. (2026) · Advanced Materials · doi:10.1002/adma.202522393 · Cited by 3
Power Management Circuit Techniques for Miniature Biomedical Sensing Systems
Shim, M., Kim, D., Kim, J. T., Kim, M., Li, Y., Hamed, E. A., Wu, X. L., Peng, Y., Jeong, J., Jung, W., et al. (2026) · IEEE Open Journal of the Solid-State Circuits Society · doi:10.1109/ojsscs.2026.3655336 · Cited by 3
Acoustic Impedance‐Tailored High‐Performance Ultrasound‐Driven Triboelectric Nanogenerators
Kim, Y., Chung, Y., Hwang, J., Jeong, J., Kim, B., Kang, D., Choi, B., Yoon, H., & Kim, S. (2026) · Advanced Energy Materials · doi:10.1002/aenm.202505099 · Cited by 3
Salahi, R., Moezzi, M., Ghafoorifard, H., & Kiani, M. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.104482 · Cited by 3
Chang, Y., Wang, W., Zou, Y., & Yang, K. (2025) · Custom Integrated Circuits Conference · doi:10.1109/cicc63670.2025.10982893 · Cited by 3
Piezoelectricity in Biomedical Applications
Jiang, L., & Wu, J. (2024) · Wiley eBooks · doi:10.1002/9783527841233.ch20 · Cited by 3
A Sparsity-Adapted Hardware Implementation of SNN for Cortical Spike Trains Decoding
Li, T., Yang, J., Liu, T., Dong, S., Fang, C., Chen, W., & Zhang, S. (2023) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas58349.2023.10389111 · Cited by 3
Zou, Y., Liao, H.-C., Wang, W., Kim, W., Su, Y., Robinson, J. T., & Yang, K. (2025) · Custom Integrated Circuits Conference · doi:10.1109/cicc63670.2025.10983569 · Cited by 3
Recent advances in transducers for through-tissue ultrasonic power transfer
Chu, Y., Naderi, A. A., Wu, H., Xue, X., Oelze, M. L., & Jiang, X. (2026) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ae5f8a · Cited by 3
Lee, J., Jeon, J., Park, J.-H., Kang, S.-H., Park, Y.-S., Chae, M., Han, J., Kim, K., Lee, J., Choi, S., et al. (2026) · Advanced Functional Materials · doi:10.1002/adfm.78432 · Cited by 3
3D Heterogeneous and Flexible Package Integration for Zero-Power Wireless Neural Recording
Sayeed, S. Y. B., Venkatakrishnan, S. B., Monshi, M. M., Abdal, A., Volakis, J. L., & Raj, P. M. (2020) · IEEE Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc32862.2020.00163 · Cited by 3
Micropyramid structured photo capacitive interfaces
Nikić, M., Opančar, A., Hartmann, F., Migliaccio, L., Jakešová, M., Głowacki, E. D., & Đerek, V. (2022) · Nanotechnology · doi:10.1088/1361-6528/ac5927 · Cited by 3
Subwavelength-Scale 2D Superoscillatory Beam Scanning in Huygens' Box for Wireless Power Delivery
Abdolrazzaghi, M., Genov, R., & Eleftheriades, G. V. (2024) · IEEE MTT-S International Microwave Symposium digest · doi:10.1109/ims40175.2024.10600405 · Cited by 3
Lefaix, L., Navarro, M., Nogués, C., Blanquer, A., & Murillo, G. (2025) · Advanced Science · doi:10.1002/advs.202415028 · Cited by 3
Khazaei, Y., & Sodagar, A. M. (2025) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas56072.2025.11043476 · Cited by 3
Forssell, M., Cheng, B. C., Kusyk, D. M., Whiting, A. C., Wang, E. W., & Grover, P. (2025) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas56072.2025.11042934 · Cited by 3
Ultrasonic Index Modulation With Spread Spectrum for Intra-Body Communications
Wang, Q., Guan, Q., Cheng, J., Jia, X., Xie, M., & Tang, Y. (2023) · International Conference on Communications · doi:10.1109/icc45041.2023.10279503 · Cited by 3
Simulation and Experimental Evaluation of Energy Harvesting Circuits with Magnetoelectric Antennas
Das, D., Xu, Z., Nasrollahpour, M., Martos-Repath, I., Zaeimbashi, M., Khalifa, A., Mittal, A., Cash, S. S., Sun, N. X., Shrivastava, A., et al. (2021) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas47672.2021.9531912 · Cited by 3
Wang, D., Wang, M., Zhang, Z., Wang, J., Zhou, Z., Lai, P. T., & Huang, X. (2024) · Nano Research · doi:10.26599/nr.2025.94907043 · Cited by 2
Selective Wireless Stimulation of Rat Sciatic Nerve
Frederick, R. A., Troyk, P. R., & Cogan, S. F. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175335 · Cited by 2
Engineering Materials for Neurotechnology
Ghezzi, D. (2023) · Advanced Engineering Materials · doi:10.1002/adem.202201412 · Cited by 2
There and Back Again: Building Systems That Integrate, Interface, and Interact with the Human Body
Boys, A. J. (2024) · Advanced Biology · doi:10.1002/adbi.202300366 · Cited by 2
Progress on Direct Regulation of Systemic Immunity by the Central Nervous System
Tan, X., Zhang, J., Chen, W.-M., Chen, T., Cui, G., Liu, Z., & Hu, R. (2025) · World Neurosurgery · doi:10.1016/j.wneu.2025.123814 · Cited by 2
Park, S., Park, K., Kim, T. Y., Jo, Y., Kim, J., Son, K., Choi, H., Ok, M., Shin, S. R., & Seo, J. (2026) · Small · doi:10.1002/smll.202510949 · Cited by 2
GaAs-Based Photovoltaic Infrared Energy Harvesting for Microscale Biomedical Implants
Sun, Y., Letner, J. G., Lee, J., Ahmed, N. K., Chestek, C. A., Blaauw, D. T., & Phillips, J. (2022) · Conference record of the IEEE Photovoltaic Specialists Conference · doi:10.1109/pvsc48317.2022.9938467 · Cited by 2
Smart materials for healthcare industries
Ghosh, S. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-96020-5.00190-4 · Cited by 2
The development, use, and challenges of electromechanical tissue stimulation systems
Hu, J., Anderson, W. S., Hayes, E., Strauss, E. A., Lang, J., Bacos, J., Simacek, N., Vu, H. H., McCarty, O. J. T., Kim, H., et al. (2024) · Artificial Organs · doi:10.1111/aor.14808 · Cited by 2
Single-atom thermoelectric materials: a new opportunity
Xu, B. (2023) · Materials Lab · doi:10.54227/mlab.20220059 · Cited by 2
Han, C. H., Lin, C., Mao, J., Yu, S. P., & Zhang, Z. (2023) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc40787.2023.10340676 · Cited by 2
Allam, A., Bhardwaj, A., Sabra, K. G., & Ertürk, A. (2022) · Active and Passive Smart Structures and Integrated Systems · doi:10.1117/12.2614635 · Cited by 2
Pre-Filtering of Stimuli for Improved Energy Efficiency in Electrical Neural Stimulation
Varkevisser, F., Rashidi, A., Costa, T. L., Giagka, V., & Serdijn, W. A. (2022) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas54905.2022.9948643 · Cited by 2
Geläschus, A., Absar, M. W., Singer, J. A., Bahr, A., & Kuhl, M. (2023) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs58634.2023.10382932 · Cited by 2
Design and Implementation of a Simulation Framework for a Bio–Neural Dust System
Dambri, O. A., Azarnoush, A., Makrakis, D., Levesque, G., Witter, M., & Hafid, A. S. (2025) · Modelling—International Open Access Journal of Modelling in Engineering Science · doi:10.3390/modelling6010008 · Cited by 2
Lee, K., Lall, R. K., Chopra, S., Evans, M. J., Maharbiz, M. M., Seo, Y., & Anwar, M. (2023) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2023.11.057 · Cited by 2
Self-citationStimulation technology for brain and nerves, now and futurePreprint
Kuwabara, M., & Kanai, R. (2024) · arXiv (Cornell University) · doi:10.48550/arxiv.2402.18808 · Cited by 2
Mutlu, S., & Kaya, A. A. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114573 · Cited by 2
Hosur, S., Lee, H., Zhou, T., & Kiani, M. (2025) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2025.3598568 · Cited by 2
Lefaix, L., Navarro, M., Bačáková, L., Estéve, J., Nogués, C., Blanquer, A., & Murillo, G. (2026) · Small · doi:10.1002/smll.202511170 · Cited by 2
A Tissue-Coupling Body Channel Powering Technique for the Internet of Implanted Things
Han, C. H., Lin, C., Yu, S. P., Zhang, Z., & Mao, J. (2025) · IEEE Internet of Things Journal · doi:10.1109/jiot.2025.3635711 · Cited by 2
State-of-the-Art Technology on Highly Miniaturized Free-Floating Neural Implants
Khalifa, A., & Etienne‐Cummings, R. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_114-1 · Cited by 1
Advances in High-Resolution, Miniaturized Bioelectrical Neural Interface Design
Nguyen, A. T., Xu, J., Wu, T., Luu, D. K., & Yang, Z. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_23 · Cited by 1
Millimeter-scale radioluminescent power for electronic sensors
Kandala, A., Wang, S., Blecha, J. E., Wang, Y.-H., Lall, R. K., Niknejad, A. M., Seo, Y., Evans, M. J., Flavell, R. R., VanBrocklin, H. F., et al. (2024) · iScience · doi:10.1016/j.isci.2024.111686 · Cited by 1
Advances in High-Resolution, Miniaturized Bioelectrical Neural Interface Design
Nguyen, A. T., Xu, J., Wu, T., Luu, D. K., & Yang, Z. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_23-2 · Cited by 1
Differential Tissue‐Coupled Powering for Battery‐Free Injectable Electroceuticals
Wu, H., Mahmud, S. A. S., Halac, M., Omi, A. I., Rodas, D. S. B., Dados, J., Cheng, C., Jiang, A., Wallace, C., Singh, A., et al. (2026) · Advanced Science · doi:10.1002/advs.76915 · Cited by 1
Li, M., Ly, C. M., Wen, J., Rustogi, P., & Meng, E. F. (2026) · Bioelectronic Medicine · doi:10.1186/s42234-025-00199-0 · Cited by 1
Engineered Materials for Probing and Perturbing Brain Chemistry
Krasley, A. T., Bulumulla, C., & Beyene, A. G. (2022) · Springer eBooks · doi:10.1007/978-3-031-11409-0_3 · Cited by 1
Ultrasonic Wireless Neural Recording and Stimulation Interfaces
Sonmezoglu, S., Shen, K., Carmena, J. M., & Maharbiz, M. M. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_10-2 · Cited by 1
Self-citationOlaitan, G. O., Asiamah, R., Lynch, W. J., & Venton, B. J. (2026) · ACS Sensors · doi:10.1021/acssensors.6c00729 · Cited by 1
Sheng, X., Wenxin, 赵. Z., Lizhu, 李. L., Yunxiang, 黄. H., & Ding, H. (2023) · Chinese Journal of Lasers · doi:10.3788/cjl221562 · Cited by 1
Advanced silicon nanomembrane based bioelectronics for flexible and stretchable implantable systems
Lee, J., Lee, Y., Woo, H., Hong, M., Lee, D. J., & Sang, M. (2026) · Biomedical Engineering Letters · doi:10.1007/s13534-026-00568-x · Cited by 1
CMOS-based microanalysis systems
Kiliç, T., Ghoreishizadeh, S. S., & Carrara, S. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-823846-2.00006-7 · Cited by 1
Implantable soft electronics and sensors
Lim, H. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-99147-6.00011-9 · Cited by 1
Lv, Y., Yao, X., Zhan, L., Shi, J., Wang, X., Yan, H., Wang, X., Huang, C., Qian, Y., & Ouyang, Y. (2024) · Authorea · doi:10.22541/au.171468403.30844874/v1 · Cited by 1
CDM in Neural Communication Based on Oscillatory Characteristics of Membrane Potential
Luo, H., Huang, Y., & Lin, L. (2025) · IEEE Transactions on Molecular Biological and Multi-Scale Communications · doi:10.1109/tmbmc.2025.3556841 · Cited by 1
Characterization of a Miniature Broadband Antenna for Implantable Neuromodulation Devices
Gao, M., Ding, C., Šipuš, Z., Shoaran, M., & Skrivervik, A. K. (2023) · International Conference on Applied Electromagnetics and Communications · doi:10.1109/icecom58258.2023.10367951 · Cited by 1
Bulk- Current-Regulated Rectifier for Battery-less Ultrasound-Powered Implantable Medical Devices
Shah, M. O., Privitera, M., Grasso, A. D., & Pennisi, S. (2025) · Conference on Ph.D. Research in Microelectronics and Electronics · doi:10.1109/prime66228.2025.11203300 · Cited by 1
Li, X., Peng, W., Kumar, L., Zhao, X., Huang, C., & Du, S. (2026) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc49663.2026.11409217 · Cited by 1
The Promises and Future Directions of Wireless Stimulation in Biomedical Applications
Wallace, G. G. (2023) · Materials Lab · doi:10.54227/mlab.20220058 · Cited by 1
Dual-Resonance Magnetoelectric Power and Data Links for Miniaturized Wireless Bio-Implants
Wang, W., Chen, E. C., Ahmed, N., Kim, W., Zou, Y., Woods, J. E., Su, Y., Liao, H.-C., Robinson, J. T., & Yang, K. (2025) · ACM Annual International Conference on Mobile Computing and Networking (MobiCom) · doi:10.1145/3680207.3765271 · Cited by 1
Williams, M. T., Lawlor, G. L., Collar, B., & Irazoqui, P. P. (2026) · Communications Biology · doi:10.1038/s42003-026-09989-x · Cited by 1
Huang, Z. L., Jiang, X. Z., Gao, X., Wang, B., Huang, P., Zhou, J., Wang, C., & Huang, D. (2026) · Surfaces and Interfaces · doi:10.1016/j.surfin.2026.110047 · Cited by 1
Powering smart orthopedic implants using acoustic waves: An ex vivo study
Freychet, O., Garraud, N., Defoort, M., Guigo, S., Burdin, V., Basrour, S., Letissier, H., Dardenne, G., & Gasnier, P. (2026) · Ultrasonics · doi:10.1016/j.ultras.2026.108231 · Cited by 1
Untethered thin-film neurostimulator wrapped around tiny nerve trunks for wireless neuromodulation
Sun, R., Wang, W., Liu, W. X., Yang, M., Zhang, D., Zou, Z., Yang, K., Gao, C., She, J., Zhang, Z., et al. (2026) · Science Advances · doi:10.1126/sciadv.aec9247 · Cited by 1
SkinECG: An orthogonal remote powering wearable skin-like sensor
Tan, J. S. Y., Li, Z., Xiong, S., Lee, S., Fong, J. Y., Tang, T., Li, Z., Li, Z., Park, K., Kim, G., et al. (2026) · Science Advances · doi:10.1126/sciadv.aec9803 · Cited by 1
Fully 3D Printed Biodegradable, Wireless, and Smart Bioimplants with Voxelated SemiconductorPreprint
Kang, S., Lee, J., Jeon, J., Park, J.-H., Kang, S.-H., Park, Y.-S., Chae, M.-S., Han, J., Kim, K., Lee, J., et al. (2024) · Research Square · doi:10.21203/rs.3.rs-3631026/v1 · Cited by 1
Piezo Capsule: Ultrasonic Way of Wireless Pressure Measurement
Mutlu, S., Aghakhani, A., & Sitti, M. (2022) · Advanced Intelligent Systems · doi:10.1002/aisy.202200125 · Cited by 1
Light-Controlled Battery-Integrated Nerve Conduit for Peripheral Nerve Pain Management
He, E., Wang, H., Li, F., Ye, T., Jiao, Y., Li, L., Song, J., Zhang, H., Yang, S., Wang, J., et al. (2026) · ACS Nano · doi:10.1021/acsnano.6c06247 · Cited by 1
Robust magnetoelectric backscatter communication system for bioelectronic implants
Alrashdan, F. T., Woods, J. E., Chen, E. C., Tan, W., Yu, Z., Wang, W., John, M. M., Jaworski, L. M., Bernard, D., Post, A., et al. (2026) · Communications Engineering · doi:10.1038/s44172-026-00678-5 · Cited by 1
Jiao, R., Zheng, Y., Ghajari, S., Sadeghi, S., Cortese, A. J., McEuen, P. L., Molnar, A. C., & Lee, S. (2025) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas56072.2025.11044230 · Cited by 1
An Adaptive ASIC for Closed-Loop Low-Power Pulse-Based Ultrasonic Data Transmission
Kashani, Z., & Kiani, M. (2022) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas48785.2022.9937874 · Cited by 1
Metadata
- Authors
- Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R.
- Affiliations
- University of California, San Francisco (US)
- Boise State University (US)
- University of California, Berkeley (US)
- ORCID
- Venue
- Nature Biomedical Engineering
- Published
- 2020-02-19
- Volume
- 4
- Issue
- 2
- Pages
- 207-222
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W3008994271
- Semantic Scholar
- c29400b85b4405b0dd161bced15893ee5f96780f
- Cited by
- 442
- References
- 95
- Citations by year
- 2026: 38 · 2025: 71 · 2024: 76 · 2023: 73 · 2022: 79 · 2021: 70 · 2020: 35
- FWCI
- 29.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- ScholarWorks (Boise State University) (submittedVersion)
- Funders
- National Science Foundation (1551239)
- United States Department of Defense | Defense Advanced Research Projects Agency (HR011-15-2-0006)
- U.S. Department of Health & Human Services | National Institutes of Health (1551239, R21EY027570, T32 GM008155)
- McKnight Foundation (Technological Innovations in Neuroscience Award)
- The Chan Zuckerberg Biohub
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- implantable neural stimulator, ultrasonic power transfer, piezoceramic transducers, backscatter modulation, two-way communication, closed-loop neurostimulation, sciatic nerve stimulation, energy storage capacitors
- MeSH terms
- Animals, Equipment Design, Electric Power Supplies, Sciatic Nerve, Signal Processing, Computer-Assisted, Ultrasonics, Rats, Implantable Neurostimulators, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.