A wireless millimetre-scale implantable neural stimulator with ultrasonically powered bidirectional communication
The DOI matches its Crossref record; 95 of the 95 references it cites were found in a registry or an index.
Abstract
Clinically approved neural stimulators are limited by battery requirements, as well as by their large size compared with the stimulation targets. Here, we describe a wireless, leadless and battery-free implantable neural stimulator that is 1.7 mm 3 and that incorporates a piezoceramic transducer, an energy-storage capacitor and an integrated circuit. An ultrasonic link and a hand-held external transceiver provide the stimulator with power and bidirectional communication. The stimulation protocols were wirelessly encoded on the fly, reducing power consumption and on-chip memory, and enabling protocol complexity with a high temporal resolution and low-latency feedback. Uplink data indicating whether stimulation occurs are encoded by the stimulator through backscatter modulation and are demodulated at the external transceiver. When embedded in ex vivo porcine tissue, the integrated circuit efficiently harvested ultrasonic power, decoded downlink data for the stimulation parameters and generated current-controlled stimulation pulses. When cuff-mounted and acutely implanted onto the sciatic nerve of anaesthetized rats, the device conferred repeatable stimulation across a range of physiological responses. The miniaturized neural stimulator may facilitate closed-loop neurostimulation for therapeutic interventions.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Specifically, recent studies have demonstrated the feasibility of piezoelectric,[327] near field communication (NFC),[328] and ultrasonic technologies[329] in power supply and data transmission.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [329]
In the citing paper
“Stimulation holds tremendous promise for prosthetic information feedback[86,515] and rehabilitation.[329,516,517]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [329]
In the citing paper
“Interfaces of the peripheral nerves such as the ultrasonic neural dust, StimDust, and the NeuroTalk active Utah electrode array demonstrated good performance in monitoring and activating the sciatic nerve [42], [52], [53].”
From Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review (2024) · cites this paper as [52]
Citations
Cites
Scoville, W. B. (1949) · Journal of neurosurgery · doi:10.3171/jns.1949.6.1.0065 · Cited by 7,381
Long-term suppression of tremor by chronic stimulation of the ventral intermediate thalamic nucleus
Benabid, A. L., Pollak, P., Hoffmann, D., Gervason, C., Hommel, M., Perret, J. E., de Rougemont, J., & Gao, D. M. (1991) · The Lancet · doi:10.1016/0140-6736(91)91175-t · Cited by 1,787
Ultrasound-Enhanced Systemic Thrombolysis for Acute Ischemic Stroke
Alexandrov, A. V., Molina, C. A., Grotta, J. C., Garami, Z., Ford, S. R., Alvarez-Sabin, J., Montaner, J., Saqqur, M., Demchuk, A. M., Moyé, L. A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa041175 · Cited by 1,046
Koopman, F. A., Chavan, S. S., Miljko, S., Grazio, S., Sokolovic, S., Schuurman, P. R., Mehta, A. D., Levine, Y. A., Faltys, M., Zitnik, R., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1605635113 · Cited by 1,024
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Ajiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Wireless Recording in the Peripheral Nervous System with Ultrasonic Neural Dust
Seo, D., Neely, R. M., Shen, K., Singhal, U., Alon, E., Rabaey, J. M., Carmena, J. M., & Maharbiz, M. M. (2016) · Neuron · doi:10.1016/j.neuron.2016.06.034 · Cited by 557
Self-citationHassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501
Ortiz-Catalan, M., Håkansson, B., & Brånemark, R. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008933 · Cited by 484
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468
Fenoy, A. J., & Simpson, R. K. (2014) · Journal of Neurosurgery · doi:10.3171/2013.10.jns131225 · Cited by 449
A spiral nerve cuff electrode for peripheral nerve stimulation
Naples, G. G., Mortimer, J. T., Scheiner, A., & Sweeney, J. D. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.8670 · Cited by 415
Bonaz, B., Sinniger, V., & Pellissier, S. (2017) · Frontiers in Immunology · doi:10.3389/fimmu.2017.01452 · Cited by 405
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398
Electrical properties of implant encapsulation tissue
Grill, W. M., & Thomas Mortimer, J. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368219 · Cited by 376
Stanslaski, S., Afshar, P., Cong, P., Giftakis, J., Stypulkowski, P., Carlson, D., Linde, D., Ullestad, D., Avestruz, A.-T., & Denison, T. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2183617 · Cited by 330
Bioelectronic medicines: a research roadmap
Birmingham, K., Gradinaru, V., Anikeeva, P., Grill, W. M., Pikov, V., McLaughlin, B., Pasricha, P., Weber, D., Ludwig, K., & Famm, K. (2014) · Nature Reviews Drug Discovery · doi:10.1038/nrd4351 · Cited by 322
In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording
Venkatraman, S., Hendricks, J., King, Z. A., Sereno, A. J., Richardson-Burns, S., Martin, D., & Carmena, J. M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2109399 · Cited by 319
Self-citationThe Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation
Gorman, P. H., & Mortimer, J. T. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325041 · Cited by 313
Vagus Nerve Stimulation for Treatment of Partial Seizures: 2. Safety, Side Effects, and Tolerability
Ramsay, R. E., Uthman, B. M., Augustinsson, L. E., Upton, A. R. M., Naritoku, D., Willis, J., Treig, T., Barolat, G., Wernicke, J. F., & First International Vagus Nerve Stimulation Study Group (1994) · Epilepsia · doi:10.1111/j.1528-1157.1994.tb02483.x · Cited by 260
Charthad, J., Weber, M. J., Chang, T. C., & Arbabian, A. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2427336 · Cited by 245
A mm-Sized Wireless Implantable Device for Electrical Stimulation of Peripheral Nerves
Charthad, J., Chang, T. C., Liu, Z., Sawaby, A., Weber, M. J., Baker, S., Gore, F., Felt, S. A., & Arbabian, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2799623 · Cited by 230
Fang, H., Zhao, J., Yu, K. J., Song, E., Farimani, A. B., Chiang, C.-H., Jin, X., Xue, Y., Xu, D., Du, W., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1605269113 · Cited by 225
A learning-based approach to artificial sensory feedback leads to optimal integration
Dadarlat, M. C., O'Doherty, J. E., & Sabes, P. N. (2015) · Nature Neuroscience · doi:10.1038/nn.3883 · Cited by 210
Boehler, C., Oberueber, F., Schlabach, S., Stieglitz, T., & Asplund, M. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b13468 · Cited by 200
Blood pressure control with selective vagal nerve stimulation and minimal side effects
Plachta, D. T. T., Gierthmuehlen, M., Cota, O., Espinosa, N., Boeser, F., Herrera, T. C., Stieglitz, T., & Zentner, J. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/036011 · Cited by 187
Nanostructured platinum grass enables superior impedance reduction for neural microelectrodes
Boehler, C., Stieglitz, T., & Asplund, M. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.07.036 · Cited by 179
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., & Tyler, D. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026002 · Cited by 175
Neural Dust: An Ultrasonic, Low Power Solution for Chronic Brain-Machine Interfaces
Seo, D., Carmena, J. M., Rabaey, J. M., Alon, E., & Maharbiz, M. M. (2013) · arXiv · doi:10.48550/arxiv.1307.2196 · Cited by 172
Self-citationCogan, S. F., Troyk, P. R., Ehrlich, J., & Plante, T. D. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851503 · Cited by 162
Lee, H.-M., Kwon, K. Y., Li, W., & Ghovanloo, M. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2355814 · Cited by 161
Model validation of untethered, ultrasonic neural dust motes for cortical recording
Seo, D., Carmena, J. M., Rabaey, J. M., Maharbiz, M. M., & Alon, E. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.07.025 · Cited by 158
Self-citationThe Nucleus 22-Channel Cochlear Implant System
Patrick, J. F., & Clark, G. M. (1991) · Ear and Hearing · doi:10.1097/00003446-199108001-00002 · Cited by 156
The response of the myelinated nerve fiber to short duration biphasic stimulating currents
van den Honert, C., & Mortimer, J. T. (1979) · Annals of Biomedical Engineering · doi:10.1007/bf02363130 · Cited by 152
Simulation of Intracranial Acoustic Fields in Clinical Trials of Sonothrombolysis
Baron, C., Aubry, J., Tanter, M., Meairs, S. P., & Fink, M. (2009) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2008.11.014 · Cited by 151
Closing the Loop on Deep Brain Stimulation for Treatment-Resistant Depression
Widge, A. S., Malone, D. A., & Dougherty, D. D. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00175 · Cited by 143
Pranti, A. S., Schander, A., Bödecker, A., & Lang, W. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.08.007 · Cited by 138
Xie, X., Rieth, L., Williams, L., Negi, S., Bhandari, R., Caldwell, R., Sharma, R., Tathireddy, P., & Solzbacher, F. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026016 · Cited by 137
Review of recent advances in peripheral nerve stimulation (PNS)
Chakravarthy, K., Nava, A., Christo, P. J., & Williams, K. (2016) · Current Pain and Headache Reports · doi:10.1007/s11916-016-0590-8 · Cited by 136
Selective stimulation of the human femoral nerve with a flat interface nerve electrode
Schiefer, M. A., Polasek, K. H., Triolo, R. J., Pinault, G. C. J., & Tyler, D. J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026006 · Cited by 130
Ganji, M., Tanaka, A., Gilja, V., Halgren, E., & Dayeh, S. A. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201703019 · Cited by 126
Stieglitz, T., Beutel, H., & Meyer, J.-U. (1997) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(97)01494-5 · Cited by 125
Electrical Stimulation of the Human Cochlea: A Preliminary Report
Michelson, R. P. (1971) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1971.00770060455016 · Cited by 125
Lee, B., Koripalli, M. K., Jia, Y., Acosta, J., Sendi, M. S. E., Choi, Y., & Ghovanloo, M. (2018) · Scientific Reports · doi:10.1038/s41598-018-24465-1 · Cited by 120
Johnson, B. C., Gambini, S., Izyumin, I., Moin, A., Zhou, A., Alexandrov, G., Santacruz, S. R., Rabaey, J. M., Carmena, J. M., & Muller, R. (2017) · 2017 Symposium on VLSI Circuits · doi:10.23919/vlsic.2017.8008543 · Cited by 119
Self-citationHigh frequency electrical conduction block of the pudendal nerve
Bhadra, N., Bhadra, N., Kilgore, K., & Gustafson, K. J. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/2/012 · Cited by 117
Inversion of the current-distance relationship by transient depolarization
Grill, W. M., & Mortimer, J. T. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.553708 · Cited by 109
Foreign Body Reaction to Implantable Biosensors: Effects of Tissue Trauma and Implant Size
Wang, Y., Vaddiraju, S., Gu, B., Papadimitrakopoulos, F., & Burgess, D. J. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815601869 · Cited by 107
Operative and Technical Complications of Vagus Nerve Stimulator Implantation
Spuck, S., Tronnier, V., Orosz, I., Schönweiler, R., Sepehrnia, A., Nowak, G., & Sperner, J. (2010) · Operative Neurosurgery · doi:10.1227/neu.0b013e3181f88867 · Cited by 103
Lin, Y.-P., Yeh, C.-Y., Huang, P.-Y., Wang, Z.-Y., Cheng, H.-H., Li, Y.-T., Chuang, C.-F., Huang, P.-C., Tang, K.-T., Ma, H.-P., et al. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2403282 · Cited by 100
“Long-term stability of stimulating spiral nerve cuff electrodes on human peripheral nerves”
Christie, B. P., Freeberg, M., Memberg, W. D., Pinault, G. J. C., Hoyen, H. A., Tyler, D. J., & Triolo, R. J. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0285-3 · Cited by 97
Casarotto, R. A., Adamowski, J. C., Fallopa, F., & Bacanelli, F. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(03)00293-4 · Cited by 93
Update on Peripheral Nerve Electrodes for Closed-Loop Neuroprosthetics
Rijnbeek, E. H., Eleveld, N., & Olthuis, W. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00350 · Cited by 91
Acoustic lens design by genetic algorithms
Håkansson, A., Sánchez‐Dehesa, J., & Sánchis, L. (2004) · Physical Review B · doi:10.1103/physrevb.70.214302 · Cited by 84
Petrossians, A., Whalen III, J. J., Weiland, J. D., & Mansfeld, F. (2011) · Journal of The Electrochemical Society · doi:10.1149/1.3559477 · Cited by 81
The Microbead: A Highly Miniaturized Wirelessly Powered Implantable Neural Stimulating System
Khalifa, A., Karimi, Y., Wang, Q., Montlouis, W., Garikapati, S., Stanacevic, M., Thakor, N., & Etienne-Cummings, R. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2802443 · Cited by 76
A Sub-millimeter, Inductively Powered Neural Stimulator
Freeman, D. K., O'Brien, J. M., Kumar, P., Daniels, B., Irion, R. A., Shraytah, L., Ingersoll, B. K., Magyar, A. P., Czarnecki, A., Wheeler, J., et al. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00659 · Cited by 72
Active sensing of target location encoded by cortical microstimulation
Venkatraman, S., & Carmena, J. M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2117441 · Cited by 66
Self-citationStimDust: A 6.5mm3, wireless ultrasonic peripheral nerve stimulator with 82% peak chip efficiency
Johnson, B. C., Shen, K., Piech, D., Ghanbari, M. M., Li, K. Y., Neely, R., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2018) · 2018 IEEE Custom Integrated Circuits Conference (CICC) · doi:10.1109/cicc.2018.8357047 · Cited by 64
Self-citationHigh-performance wireless powering for peripheral nerve neuromodulation systems
Tanabe, Y., Ho, J. S., Liu, J., Liao, S.-Y., Zhen, Z., Hsu, S., Shuto, C., Zhu, Z.-Y., Ma, A., Vassos, C., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0186698 · Cited by 63
Petrossians, A., Whalen, J., Weiland, J., & Mansfeld, F. (2011) · ECS Meeting Abstracts · doi:10.1149/ma2011-02/35/2239 · Cited by 63
A silicon carbide array for electrocorticography and peripheral nerve recording
Diaz-Botia, C. A., Luna, L. E., Neely, R. M., Chamanzar, M., Carraro, C., Carmena, J. M., Sabes, P. N., Maboudian, R., & Maharbiz, M. M. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7698 · Cited by 61
Self-citationKabir, S. M. R., Rajaraman, C., Rittey, C. D. C., Zaki, H. S., Kemeny, A. A., & McMullan, J. (2009) · Child s Nervous System · doi:10.1007/s00381-009-0849-z · Cited by 59
Schander, A., Tesmann, T., Strokov, S., Stemmann, H., Kreiter, A. K., & Lang, W. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592138 · Cited by 56
Bioelectronic devices: Wirelessly powered implants
Thimot, J., & Shepard, K. L. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0051 · Cited by 51
Interphase gap as a means to reduce electrical stimulation thresholds for epiretinal prostheses
Weitz, A. C., Behrend, M. R., Ahuja, A. K., Christopher, P., Wei, J., Wuyyuru, V., Patel, U., Greenberg, R. J., Humayun, M. S., Chow, R. H., et al. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016007 · Cited by 50
11.8 Integrated ultrasonic system for measuring body-fat composition
Tang, H.-Y., Lu, Y., Fung, S. L., Horsley, D. A., & Boser, B. E. (2015) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2015.7063000 · Cited by 49
Impedance Properties of Metal Electrodes for Chronic Recording from Mammalian Nerves
Stein, R. B., Charles, D., Gordon, T., Hoffer, J.-A., & Jhamandas, J. (1978) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1978.326287 · Cited by 48
Brunton, E. K., Winther-Jensen, B., Wang, C., Yan, E. B., Hagh Gooie, S., Lowery, A. J., & Rajan, R. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00265 · Cited by 46
Clinical experience with a helical bipolar stimulating lead
TARVER, W. B., GEORGE, R. E., MASCHINO, S. E., HOLDER, L. K., & WERNICKE, J. F. (1992) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1992.tb02933.x · Cited by 46
Rodent wearable ultrasound system for wireless neural recording
Piech, D. K., Kay, J. E., Boser, B. E., & Maharbiz, M. M. (2017) · 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8036802 · Cited by 38
Self-citationTakenaka, T. (2010) · Elsevier eBooks · doi:10.1533/9781845699758.1.130 · Cited by 35
Mechanisms underlying the regulation of motor unit contraction in the skeletal muscle.
Celichowski, J. (2000) · PubMed · Cited by 34
Integrated electrode and high density feedthrough system for chip-scale implantable devices
Green, R. A., Guenther, T., Jeschke, C., Jaillon, A., Yu, J. F., Dueck, W. F., Lim, W. W., Henderson, W. C., Vanhoestenberghe, A., Lovell, N. H., et al. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.04.054 · Cited by 34
Ultrasonic Power/Data Telemetry and Neural Stimulator With OOK-PM Signaling
Luo, Y.-S., Wang, J.-R., Huang, W.-J., Tsai, J.-Y., Liao, Y.-F., Tseng, W.-T., Yen, C., Li, P., & Liu, S.-I. (2013) · IEEE Transactions on Circuits & Systems II Express Briefs · doi:10.1109/tcsii.2013.2286000 · Cited by 33
Microstimulation of afferents in the sacral dorsal root ganglia can evoke reflex bladder activity
Bruns, T. M., Weber, D. J., & Gaunt, R. A. (2014) · Neurourology and Urodynamics · doi:10.1002/nau.22514 · Cited by 32
Ultrasonic beamforming system for interrogating multiple implantable sensors
Seo, D., Tang, H.-Y., Carmena, J. M., Rabaey, J. M., Alon, E., Boser, B. E., & Maharbiz, M. M. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318942 · Cited by 31
Self-citationDesign for an Aspherical Acoustic Fresnel Lens with Phase Continuity
Sato, Y., Mizutani, K., Wakatsuki, N., & Nakamura, T. (2008) · Japanese Journal of Applied Physics · doi:10.1143/jjap.47.4354 · Cited by 29
Three-dimensional acoustic lenses with axial symmetry
Sánchis, L., Escolano, A. Y., Galindo, P. L., Pizarro, J., & Martínez‐Pastor, J. P. (2010) · Applied Physics Letters · doi:10.1063/1.3474616 · Cited by 29
A 232-channel retinal vision prosthesis with a miniaturized hermetic package
Ordonez, J. S., Schuettler, M., Ortmanns, M., & Stieglitz, T. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346545 · Cited by 28
An experimental study on passive charge balancing
Sooksood, K., Stieglitz, T., & Ortmanns, M. (2009) · Advances in Radio Science · doi:10.5194/ars-7-197-2009 · Cited by 27
Complications of DBS surgery — insights from large databases
Moro, E. (2016) · Nature Reviews Neurology · doi:10.1038/nrneurol.2016.163 · Cited by 27
Maciejasz, P., Badía, J., Boretius, T., Andreu, D., Stieglitz, T., Jensen, W., Navarro, X., & Guiraud, D. (2015) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1244-4 · Cited by 25
Caudate Microstimulation Increases Value of Specific Choices
Santacruz, S. R., Rich, E. L., Wallis, J. D., & Carmena, J. M. (2017) · Current Biology · doi:10.1016/j.cub.2017.09.051 · Cited by 24
Self-citationPena, A. E., Kuntaegowdanahalli, S. S., Abbas, J. J., Patrick, J., Horch, K. W., & Jung, R. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa814d · Cited by 22
Tibial Nerve Stimulation to Drive Genital Sexual Arousal in an Anesthetized Female Rat
Zimmerman, L., Rice, I. C., Berger, M. B., & Bruns, T. M. (2018) · The Journal of Sexual Medicine · doi:10.1016/j.jsxm.2018.01.007 · Cited by 20
Kothapalli, S. V. V. N., Partanen, A., Zhu, L., Altman, M. B., Gach, H. M., Hallahan, D. E., & Chen, H. (2018) · Journal of Therapeutic Ultrasound · doi:10.1186/s40349-018-0113-7 · Cited by 16
Interphase gap decreases electrical stimulation threshold of retinal ganglion cells
Weitz, A. C., Behrend, M. R., Humayun, M. S., Chow, R. H.-P., & Weiland, J. D. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091658 · Cited by 15
Ceramic Packages for Acoustically Coupled Neural Implants
Shen, K., & Maharbiz, M. M. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8716923 · Cited by 12
Self-citationCharacterization of the cytotoxicity and imaging properties of second-harmonic nanoparticles
Hsieh, C., Grange, R., Pu, Y., & Psaltis, D. (2010) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.860595 · Cited by 8
SEXUAL DEPENDENCY OF RAT SCIATIC NERVE FIBER CONDUCTION VELOCITY DISTRIBUTIONS
Ayaz, M., Kızıltan, E., Tuncer, S., Dalkılıç, N., Demirel, İ., Barışkaner, H., & Pehlivan, F. (2007) · International Journal of Neuroscience · doi:10.1080/00207450701239244 · Cited by 7
Fan, T., Chen, T., Zhang, W., Hu, J., Zhang, Y., & Zhang, D. (2017) · AIP conference proceedings · doi:10.1063/1.4977665 · Cited by 5
Yuan, Y., Hao, H., Wen, X., Mo, X., & Li, L. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610959 · Cited by 4
Research works printed but not linked: 1
- Cowley, A. W. Helical electrode for nerve stimulation. US patent 8,478,428 (2013).
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454
“The comparatively large size of cuff electrodes and their ease of use have also made cuff electrodes a popular platform for the development of new neuroprosthetic-related technologies, such as wireless ultrasound-driven nerve stimulation (Piech et al., 2020), self-wrapping designs (Zhang et al.”
BackgroundPiezoelectric nanogenerators for personalized healthcare
Deng, W., Zhou, Y., Libanori, A., Chen, G., Yang, W., & Chen, J. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00858g · Cited by 434
Wireless and battery-free technologies for neuroengineering
Won, S. M., Cai, L., Gutruf, P., & Rogers, J. A. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00683-3 · Cited by 360
Metadata
- Authors
- Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R.
- Affiliations
- University of California, San Francisco (US)
- Boise State University (US)
- University of California, Berkeley (US)
- ORCID
- Venue
- Nature Biomedical Engineering
- Published
- 2020-02-19
- Volume
- 4
- Issue
- 2
- Pages
- 207-222
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W3008994271
- Cited by
- 442
- References
- 95
- Citations by year
- 2026: 38 · 2025: 71 · 2024: 76 · 2023: 73 · 2022: 79 · 2021: 70 · 2020: 35
- FWCI
- 29.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- ScholarWorks (Boise State University) (submittedVersion)
- Funders
- National Science Foundation (1551239)
- United States Department of Defense | Defense Advanced Research Projects Agency (HR011-15-2-0006)
- U.S. Department of Health & Human Services | National Institutes of Health (1551239, R21EY027570, T32 GM008155)
- McKnight Foundation (Technological Innovations in Neuroscience Award)
- The Chan Zuckerberg Biohub
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- implantable neural stimulator, ultrasonic power transfer, piezoceramic transducers, backscatter modulation, two-way communication, closed-loop neurostimulation, sciatic nerve stimulation, energy storage capacitors
- MeSH terms
- Animals, Equipment Design, Electric Power Supplies, Sciatic Nerve, Signal Processing, Computer-Assisted, Ultrasonics, Rats, Implantable Neurostimulators, Wireless Technology
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.