Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays
The DOI matches its Crossref record; 75 of the 76 references it cites were found in a registry or an index.
Abstract
Stretchable wearable devices for the continuous monitoring of physiological signals from deep tissues are constrained by the depth of signal penetration and by difficulties in resolving signals from specific tissues. Here, we report the development and testing of a prototype skin-conformal ultrasonic phased array for the monitoring of haemodynamic signals from tissues up to 14 cm beneath the skin. The device allows for active focusing and steering of ultrasound beams over a range of incident angles so as to target regions of interest. In healthy volunteers, we show that the phased array can be used to monitor Doppler spectra from cardiac tissues, record central blood flow waveforms and estimate cerebral blood supply in real time. Stretchable and conformal skin-worn ultrasonic phased arrays may open up opportunities for wearable diagnostics.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Other mechanisms of flexible health monitoring in rehabilitation, like optoelectronic[263,264] and ultrasound[265,266] devices, can also be applied to heartbeat, pulse oximetry, blood pressure, and other on-body measurements.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [265]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Materials and Mechanics for Stretchable Electronics
Rogers, J. A., Someya, T., & Huang, Y. (2010) · Science · doi:10.1126/science.1182383 · Cited by 5,042
Self-citationWearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Ommen, S. R., Nishimura, R. A., Appleton, C. P., Miller, F. A., Oh, J. K., Redfield, M. M., & Tajik, A. J. (2000) · Circulation · doi:10.1161/01.cir.102.15.1788 · Cited by 2,790
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Prognosis in Acute Organ-System Failure
KNAUS, W. A., DRAPER, E. A., WAGNER, D. P., & ZIMMERMAN, J. E. (1985) · Annals of Surgery · doi:10.1097/00000658-198512000-00004 · Cited by 1,225
The Assessment of Endothelial Function: From Research Into Clinical Practice
Flammer, A. J., Anderson, T., Celermajer, D. S., Creager, M. A., Deanfield, J., Ganz, P., Hamburg, N. M., Lüscher, T. F., Shechter, M., Taddei, S., et al. (2012) · Circulation · doi:10.1161/circulationaha.112.093245 · Cited by 1,153
Speckle in ultrasound B-mode scans
Burckhardt, C. B. (1978) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1978.30978 · Cited by 1,066
Cope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
Research works printed but not linked: 1
- J. Lee, H.-S. & Sodini, C. G. in Intracranial Pressure & Neuromonitoring XVI 111–114 (Springer, 2018).
Cited by
A wearable cardiac ultrasound imager
Hu, H., Huang, H., Li, M., Gao, X., Yin, L., Qi, R., Wu, R. S., Chen, X., Ma, Y., Shi, K., et al. (2023) · Nature · doi:10.1038/s41586-022-05498-z · Cited by 644
Self-citationBioadhesive ultrasound for long-term continuous imaging of diverse organs
Wang, C., Chen, X., Wang, L., Makihata, M., Liu, H.-C., Zhou, T., & Zhao, X. (2022) · Science · doi:10.1126/science.abo2542 · Cited by 599
“Other wearable ultrasound imaging devices (12, 14-18) did not report their lateral resolutions.”
BackgroundInfluentialSelf-citationFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
A three-dimensional liquid diode for soft, integrated permeable electronics
Zhang, B., Li, J., Zhou, J., Chow, L., Zhao, G., Huang, Y., Ma, Z., Zhang, Q., Yang, Y., Yiu, C. K., et al. (2024) · Nature · doi:10.1038/s41586-024-07161-1 · Cited by 417
Self-citationA fully integrated wearable ultrasound system to monitor deep tissues in moving subjects
Lin, M., Zhang, Z., Gao, X., Bian, Y., Wu, R. S., Park, G., Lou, Z., Zhang, Z., Xu, X., Chen, X., et al. (2024) · Nature Biotechnology · doi:10.1038/s41587-023-01800-0 · Cited by 364
“…in response to stressors can benefit a broad range of populations, from athletes who need training optimization, to cardiac rehabilitation patients who require safety measures, and to general high-risk populations for cardiovascular risk stratification and prediction (Supplementary Discussion 19).”
InfluentialSelf-citationSoft wearable devices for deep-tissue sensing
Lin, M., Hu, H., Zhou, S., & Xu, S. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00427-y · Cited by 334
“Panels h and i are adapted from ref.(173), Springer Nature Limited.”
BackgroundSelf-citationHydrogels for Flexible Electronics
Zhang, Y., Tan, Y., Lao, J., Gao, H., & Yu, J. (2023) · ACS Nano · doi:10.1021/acsnano.3c02897 · Cited by 291
Soft Bioelectronics Based on Nanomaterials
Cho, K. W., Sunwoo, S.-H., Hong, Y. J., Koo, J. H., Kim, J. H., Baik, S., Hyeon, T., & Kim, D.-H. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00531 · Cited by 244
Continuous cuffless monitoring of arterial blood pressure via graphene bioimpedance tattoos
Kireev, D., Sel, K., Ibrahim, B., Kumar, N., Akbari, A., Jafari, R., & Akinwande, D. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01145-w · Cited by 225
Bioadhesive Technology Platforms
Wu, S. J., & Zhao, X. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00380 · Cited by 218
Kirigami‐Inspired Pressure Sensors for Wearable Dynamic Cardiovascular Monitoring
Meng, K., Xiao, X., Liu, Z., Shen, S., Tat, T., Wang, Z., Lu, C., Ding, W., He, X., Yang, J., et al. (2022) · Advanced Materials · doi:10.1002/adma.202202478 · Cited by 204
Robotic ultrasound imaging: State-of-the-art and future perspectives
Jiang, Z., Salcudean, S. E., & Navab, N. (2023) · Medical Image Analysis · doi:10.1016/j.media.2023.102878 · Cited by 182
Shin, Y., Lee, H. S., Hong, Y. J., Sunwoo, S.-H., Park, O. K., Choi, S. H., Kim, D.-H., & Lee, S. (2024) · Science Advances · doi:10.1126/sciadv.adi7724 · Cited by 161
Ultra‐Thin Flexible Encapsulating Materials for Soft Bio‐Integrated Electronics
Sang, M., Kim, K., Shin, J., & Yu, K. J. (2022) · Advanced Science · doi:10.1002/advs.202202980 · Cited by 161
Flexible ultrasound-induced retinal stimulating piezo-arrays for biomimetic visual prostheses
Jiang, L., Lu, G., Zeng, Y., Sun, Y., Kang, H., Burford, J. L., Gong, C., Humayun, M. S., Chen, Y., & Zhou, Q. (2022) · Nature Communications · doi:10.1038/s41467-022-31599-4 · Cited by 171
Self-citationLo, L., Zhao, J., Aono, K., Li, W., Wen, Z., Pizzella, S., Wang, Y., Chakrabartty, S., & Wang, C. (2022) · ACS Nano · doi:10.1021/acsnano.2c04962 · Cited by 154
Self-citation3D printing of polymer composites to fabricate wearable sensors: A comprehensive review
Osman, A., & Lü, J. (2023) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2023.100734 · Cited by 158
Permanent fluidic magnets for liquid bioelectronics
Zhao, X., Zhou, Y., Song, Y., Xu, J. H., Li, J., Tat, T., Chen, G., Li, S., & Chen, J. (2024) · Nature Materials · doi:10.1038/s41563-024-01802-6 · Cited by 159
A photoacoustic patch for three-dimensional imaging of hemoglobin and core temperature
Gao, X., Chen, X., Hu, H., Wang, X., Yue, W., Mu, J., Lou, Z., Zhang, R., Shi, K., Chen, X., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-35455-3 · Cited by 136
“In comparison to Doppler ultrasound imaging 35 , photoacoustic imaging has high sensitivity and contrast in detecting blood vessels, especially for small blood vessels with slow blood fl ow 56 (Fig.”
Self-citationHierarchical Piezoelectric Composites for Noninvasive Continuous Cardiovascular Monitoring
Tian, G., Deng, W., Yang, T., Zhang, J., Xu, T., Xiong, D., Lan, B., Wang, S., Sun, Y. M., Ao, Y., et al. (2024) · Advanced Materials · doi:10.1002/adma.202313612 · Cited by 142
A conformable phased-array ultrasound patch for bladder volume monitoring
Zhang, L., Marcus, C., Lin, D., Mejorado, D., Schoen, S. J., Pierce, T. T., Kumar, V., Fernandez, S. V., Hunt, D., Li, Q., et al. (2023) · Nature Electronics · doi:10.1038/s41928-023-01068-x · Cited by 148
“1, strategy I), but these face obstacles to large and precise imaging (Supplementary Note 1 and Supplementary Table 1) 16,20 .”
BackgroundFlexible electronics for cardiovascular healthcare monitoring
Zhang, T., Liu, N., Xu, J., Liu, Z., Zhou, Y., Yang, Y., Li, S., Huang, Y., & Jiang, S. (2023) · The Innovation · doi:10.1016/j.xinn.2023.100485 · Cited by 169
“(B) Transmission beamforming (left) and receiving beamforming (right) can substantially improve penetration depth and spatial resolution.(74) (C) Optical image of a flexible capacitive micromachined ultrasound transducer.”
Self-citationZhu, H., Luo, H., Cai, M., & Song, J. (2023) · Advanced Science · doi:10.1002/advs.202307693 · Cited by 147
Wei, R., Li, H., Chen, Z., Hua, Q., Shen, G., & Jiang, K. (2024) · npj Flexible Electronics · doi:10.1038/s41528-024-00370-8 · Cited by 163
“For instance, ultrasonic ceramic patches are transferred onto fl exible substrates to create ultrasonic imaging arrays for monitoring heart rate and blood fl ow velocity 78 , and μ -LED are transferred onto fl exible substrates to phototherapy 79 .”
Conformable ultrasound breast patch for deep tissue scanning and imaging
Du, W., Zhang, L., Suh, E., Lin, D., Marcus, C., Ozkan, L., Ahuja, A., Fernandez, S. V., Shuvo, I. I., Sadat, D., et al. (2023) · Science Advances · doi:10.1126/sciadv.adh5325 · Cited by 133
“Within the past 5 years, piezoelectric-based conformable ultrasound electronics have been intensively investigated for use in cardiac functions monitoring (12), hemodynamic imaging (13, 14), blood flow monitoring (15), bladder volume observation (16), muscle activation monitoring (17), transdermal drug delivery (18),…”
Smart soft contact lenses for continuous 24-hour monitoring of intraocular pressure in glaucoma care
Zhang, J., Kim, K., Kim, H. J., Meyer, D., Park, W., Lee, S. A., Dai, Y., Kim, B., Moon, H., Shah, J. V., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-33254-4 · Cited by 138
Wearable bioadhesive ultrasound shear wave elastography
Liu, H., Zeng, Y., Gong, C., Chen, X., Kijanka, P., Zhang, J., Genyk, Y., Tchelepi, H., Wang, C., Zhou, Q., et al. (2024) · Science Advances · doi:10.1126/sciadv.adk8426 · Cited by 130
“…extensively developed for imaging internal organs and evaluating various physiological features in biomedical applications such as measuring central blood pressure ( 17 ), assessing deep-tissue hemodynamics ( 18 ), monitoring cardiac functions ( 19 ), and continuously imaging diverse organs ( 20 ).”
Self-citationEmerging sensing and modeling technologies for wearable and cuffless blood pressure monitoring
Zhao, L., Liang, C., Huang, Y., Zhou, G., Xiao, Y., Ji, N., Zhang, Y., & Zhao, N. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00835-6 · Cited by 149
“Moreover, although ultrasound sensor arrays with small transducers and small pitches have high measurement accuracy, these sensors are dif fi cult to fabricate with existing technologies 71 .”
Self-citationMin, S., An, J., Lee, J. H., Kim, J. H., Joe, D. J., Eom, S. H., Yoo, C. D., Ahn, H., Hwang, J.-Y., Xu, S. H., et al. (2025) · Nature Reviews Cardiology · doi:10.1038/s41569-025-01127-0 · Cited by 178
“One of the key breakthroughs in wearable ultrasound technology is the development of stretchable ultrasonic transducers using materials such as PDMS and one to three piezoelectric composites 137,141,145,146 .”
Self-citationLin, Z., Duan, S., Liu, M., Dang, C., Qian, S., Zhang, L., Wang, H., Yan, W., & Zhu, M. (2023) · Advanced Materials · doi:10.1002/adma.202306880 · Cited by 146
Recent Advancements in Ultrasound Transducer: From Material Strategies to Biomedical Applications
Li, J., Ma, Y., Zhang, T., Shung, K. K., & Zhu, B. (2022) · BME Frontiers · doi:10.34133/2022/9764501 · Cited by 143
“Furthermore, some unique technologies, such as 3D printing and stretchable electrodes, provide new insights for ultrasound transducer fabrication [20, 21].”
BackgroundSoft Materials and Devices Enabling Sensorimotor Functions in Soft Robots
Su, J., He, K., Li, Y., Tu, J., & Chen, X. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00906 · Cited by 126
A Review of the Recent Applications of Aluminum Nitride-Based Piezoelectric Devices
Haider, S. T., Shah, M. A., Lee, D.-G., & Hur, S. (2023) · IEEE Access · doi:10.1109/access.2023.3276716 · Cited by 105
“tions [40], [42], and vein identification [43], [44], [45], [46].”
BackgroundBiomimetic Wearable Sensors: Emerging Combination of Intelligence and Electronics
Pan, D., Hu, J., Wang, B., Xia, X., Cheng, Y., Wang, C., & Lu, Y. (2023) · Advanced Science · doi:10.1002/advs.202303264 · Cited by 110
Self-citationPan, L., Han, L., Liu, H., Zhao, J., Dong, Y., & Wang, X. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2022.137929 · Cited by 102
Bioresorbable shape-adaptive structures for ultrasonic monitoring of deep-tissue homeostasis
Liu, J., Liu, N., Xu, Y., Wu, M., Zhang, H., Wang, Y., Yan, Y., Hill, A. L., Song, R., Xu, Z., et al. (2024) · Science · doi:10.1126/science.adk9880 · Cited by 118
Self-citationClinical validation of a wearable ultrasound sensor of blood pressure
Zhou, S., Park, G., Longardner, K., Lin, M., Qi, B., Yang, X., Gao, X., Huang, H., Chen, X., Bian, Y., et al. (2024) · Nature Biomedical Engineering · doi:10.1038/s41551-024-01279-3 · Cited by 126
“Serpentine copper patterns were used as both the top excitation and bottom ground electrodes to interconnect the bilayer stacking of the transducer element and backing layer 26–28 .”
Self-citationA wearable echomyography system based on a single transducer
Gao, X., Chen, X., Lin, M., Yue, W., Hu, H., Qin, S., Zhang, F., Lou, Z., Yin, L., Huang, H., et al. (2024) · Nature Electronics · doi:10.1038/s41928-024-01271-4 · Cited by 95
“Conventional EcMG uses a rigid array of transducer elements for spatial beamforming to achieve B-mode imaging, but this requires complex wiring, bulky control systems and a large amount of power 18,19 .”
Self-citationNeer, P. L. M. J. V., Peters, L. C. J. M., Verbeek, R., Peeters, B., de Haas, G., Hörchens, L., Fillinger, L., Schrama, T., Merks-Swolfs, E. J. W., Gijsbertse, K., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-47074-1 · Cited by 107
An Emerging Era: Conformable Ultrasound Electronics
Zhang, L., Du, W., Kim, J., Yu, C., & Dağdeviren, C. (2023) · Advanced Materials · doi:10.1002/adma.202307664 · Cited by 108
Advancements in wearable sensors for cardiovascular disease detection for health monitoring
Khan, B., Riaz, Z., Ahmad, R. U. S., & Khoo, B. L. (2024) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2024.100804 · Cited by 98
Artificial piezoelectric metamaterials
Gao, Z., Lei, Y., Li, Z., Yang, J., Yu, B., Yuan, X., Hou, Z., Hong, J., & Dong, S. (2025) · Progress in Materials Science · doi:10.1016/j.pmatsci.2025.101434 · Cited by 100
Self-citationA Review of Skin-Wearable Sensors for Non-Invasive Health Monitoring Applications
Mao, P., Li, H., & Yu, Z. (2023) · Sensors · doi:10.3390/s23073673 · Cited by 95
“Furthermore, recent studies have proposed skin-wearable ultrasound devices based on mechanical (acoustic) signal detection [32,71,174].”
BackgroundMethodEmerging Wearable Ultrasound Technology
Huang, H., Wu, R. S., Lin, M., & Xu, S. H. (2023) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2023.3327143 · Cited by 90
“Common choices include silicone elastomers, such as polydimethyl-siloxane [71], [72], [73] and EcoFlex [74], [75], [76], [77], and thermoplastic elastomers, such as styrene-ethylene-butylene-styrene [4].”
BackgroundMethodInfluentialSelf-citationZhou, Z.-B., Cui, T., Li, D., Jian, J., Li, Z., Ji, S., Li, X., Xu, J., Liu, H., Yang, Y., et al. (2023) · Materials · doi:10.3390/ma16062133 · Cited by 101
“The volume of ultrasound generators required by the acoustic method is large, and it is difficult to combine with a dynamic sensor [15].”
BackgroundStretchable Electronic Facial Masks for Sonophoresis
Li, S., Xu, J., Li, R., Wang, Y., Zhang, M., Li, J., Yin, S., Liu, G., Zhang, L., Li, B., et al. (2022) · ACS Nano · doi:10.1021/acsnano.1c11181 · Cited by 80
Jin, H., Zheng, Z., Cui, Z., Jiang, Y., Chen, G., Li, W., Wang, Z., Wang, J., Yang, C., Song, W., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-40181-5 · Cited by 84
Hong, Y., Jin, L., Wang, B., Liao, J., He, B., Yang, T., Long, Z., Li, P., Zhang, Z., Liu, S., et al. (2021) · Energy & Environmental Science · doi:10.1039/d1ee02353e · Cited by 71
Self-citationXue, X., Wu, H., Cai, Q., Chen, M., Moon, S., Huang, Z., Kim, T., Peng, C., Feng, W., Sharma, N., et al. (2023) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2023.3333318 · Cited by 77
“…scholars integrated multiple rigid elements into a stretchable transducer array to achieve satisfactory US imaging performance on intricate surfaces, enabling the successful and ongoing assessment of waveform patterns related to central blood pressure and deep-tissue hemodynamics [16], [17], [18].”
BackgroundEmerging Wearable Acoustic Sensing Technologies
Liu, T., Mao, Y., Dou, H., Zhang, W., Yang, J., Wu, P., Li, D., & Mu, X. (2025) · Advanced Science · doi:10.1002/advs.202408653 · Cited by 93
Cui, Z., Wang, W., Xia, H., Wang, C., Tu, J., Ji, S., Tan, J. M. R., Liu, Z., Zhang, F., Li, W., et al. (2022) · Advanced Materials · doi:10.1002/adma.202207016 · Cited by 62
Self-citationFlexible and Implantable Polyimide Aptamer-Field-Effect Transistor Biosensors
Zhao, C., Man, T., Cao, Y. F., Weiss, P. S., Monbouquette, H. G., & Andrews, A. M. (2022) · ACS Sensors · doi:10.1021/acssensors.2c01909 · Cited by 63
Poursharifi, N., Amiri, M. H., Zink, A., Üçüncü, M., & Parlak, O. (2024) · Advanced Materials · doi:10.1002/adma.202403758 · Cited by 64
Decoding tissue biomechanics using conformable electronic devices
Yoon, H., Kim, J., Sadat, D., Barrett, A., Ko, S. H., & Dağdeviren, C. (2024) · Nature Reviews Materials · doi:10.1038/s41578-024-00729-3 · Cited by 80
“…of each element can shift owing to skin dynamics, researchers have implemented beam steering techniques based on surface curvature data acquired from additional biomechanics sensors 121 or have employed long wavelength ultrasonography, which is less sensitive to changes in element positioning 122 .”
MethodDevelopment of smart wearable sensors for life healthcare
Luo, H., & Gao, B. (2021) · Engineered Regeneration · doi:10.1016/j.engreg.2021.10.001 · Cited by 76
Emerging ultrasonic bioelectronics for personalized healthcare
Jiang, L., & Wu, J. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2023.101110 · Cited by 67
Chen, W., Liu, J., Lei, S., Yang, Z., Zhang, Q., Li, Y., Huang, J., Dong, Y., Zheng, H., Wu, D., et al. (2023) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2023.3266367 · Cited by 61
Integrated, self-powered, and omni-transparent flexible electroluminescent display system
Sun, J., Chang, Y. W., Liao, J., Chang, S., Dai, S., Shang, Y., Shan, C., & Dong, L. R. (2022) · Nano Energy · doi:10.1016/j.nanoen.2022.107392 · Cited by 58
Taylor, J. M., Luan, H., Lewis, J. A., Rogers, J. A., Nuzzo, R. G., & Braun, P. V. (2022) · Advanced Materials · doi:10.1002/adma.202108391 · Cited by 61
Clinical, Safety, and Engineering Perspectives on Wearable Ultrasound Technology: A Review
Song, P., André, M. P., Chitnis, P. V., Xu, S. H., Croy, T., Wear, K. A., & Sikdar, S. (2023) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2023.3342150 · Cited by 64
“To date, the majority of the reported wearable US devices support A-mode, M-mode, and B-mode imaging [8], [18], [69], [81], [105], [110], [121], [122].”
BackgroundSelf-citationMachine Learning in Robotic Ultrasound Imaging: Challenges and Perspectives
Bi, Y., Jiang, Z., Duelmer, F., Huang, D., & Navab, N. (2024) · Annual Review of Control Robotics and Autonomous Systems · doi:10.1146/annurev-control-091523-100042 · Cited by 82
“Wang et al. applied a skin-conformal US patch array to monitor hemodynamic signals from tissues up to 14 cm beneath the skin (146).”
BackgroundAn integrated and flexible ultrasonic device for continuous bladder volume monitoring
Toymuş, A. T., Yener, U. C., Bardakçı, E., Temel, Ö. D., Köseoğlu, E., Akçören, D., Eminoğlu, B., Ali, M., Kilic, R., Tarcan, T., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-50397-8 · Cited by 63
Elloian, J. M., Jadwiszczak, J., Arslan, V., Sherman, J. D., Kessler, D. O., & Shepard, K. L. (2022) · Scientific Reports · doi:10.1038/s41598-022-20721-7 · Cited by 59
Wearable ultrasound technology
Zhou, S., Park, G., Lin, M., Yang, X., & Xu, S. H. (2025) · Nature Reviews Bioengineering · doi:10.1038/s44222-025-00329-y · Cited by 79
“These images can visualize arterial and venous flow velocities and muscle movement patterns towards and away from the probe 107 .”
Self-citationFunctional Ultrasound Neuroimaging
Montaldo, G., Urban, A., & Macé, É. (2022) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-111020-100706 · Cited by 56
object, E. L. P. C. D. D. T. C. O. T. C. R. B. T. T. S. A. T. T., Specifically, W. C. H. B. M. B. V. A. A. S., unit, I. T. O. I. E. H. O. I. S. I. L. T. A. S., properties., T. L. P. C. B. S. E. T. G., texture, I. T. C. U. E. A. A. R. S. T. D. E. P. I. S., stiffness, conductivity, T., & substance., A. T. A. C. (2023) · Soft Science · doi:10.20517/ss.2022.34 · Cited by 82
Tang, C., Liu, Z., Hu, Q., Jiang, Z., Zheng, M., Xiong, C., Wang, S., Yao, S., Zhao, Y., Wan, X., et al. (2023) · Small · doi:10.1002/smll.202304752 · Cited by 56
Lantern‐Inspired On‐Skin Helical Interconnects for Epidermal Electronic Sensors
Li, D., Cui, T., Jian, J., Yan, J., Xu, J., Li, X., Li, Z., Yan, A., Chen, Z., Shao, W., et al. (2023) · Advanced Functional Materials · doi:10.1002/adfm.202213335 · Cited by 52
A Fully Integrated Conformal Wearable Ultrasound Patch for Continuous Sonodynamic Therapy
Zou, F., Luo, Y., Zhuang, W., & Xu, T. (2024) · Advanced Materials · doi:10.1002/adma.202409528 · Cited by 50
Bai, X., Wang, D., Zhen, L., Cui, M., Liu, J., Zhao, N., Lee, C., & Yang, B. T. (2024) · International Journal of Extreme Manufacturing · doi:10.1088/2631-7990/ad62c6 · Cited by 59
Enhancing Ultrasound Power Transfer: Efficiency, Acoustics, and Future Directions
Zheng, Y., Zhang, Z., Zhang, Y., Pan, Q., Yan, X., Li, X., & Yang, Z. (2024) · Advanced Materials · doi:10.1002/adma.202407395 · Cited by 59
Self-citationProgress in wearable acoustical sensors for diagnostic applications
Li, Y., Li, Y., Zhang, R., Li, S., Liu, Z., Zhang, J., & Fu, Y. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115509 · Cited by 49
A reconfigurable and conformal liquid sensor for ambulatory cardiac monitoring
Zhao, X., Zhou, Y., Kwak, W., Li, A., Wang, S., Dallenger, M., Chen, S., Zhang, Y., Lium, A., & Chen, J. (2024) · Nature Communications · doi:10.1038/s41467-024-52462-8 · Cited by 55
Recommendations for Cardiac Point-of-Care Ultrasound Nomenclature
Kirkpatrick, J. N., Panebianco, N. L., Díaz‐Gómez, J. L., Adhikari, S., Bremer, M. L., Bronshteyn, Y. S., Damewood, S. C., Jankowski, M., Johri, A. M., Kaplan, J. R. H., et al. (2024) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2024.05.001 · Cited by 43
“57-60 Devices incorporate AI and deep learning algorithms for continuous analysis.”
Wearable ultrasound devices: An emerging era for biomedicine and clinical translation
Hu, H., Hu, C., Guo, W., Zhu, B., & Wang, S. (2024) · Ultrasonics · doi:10.1016/j.ultras.2024.107401 · Cited by 53
Self-citationRen, D., Yin, Y., Li, C., Chen, R., & Shi, J. (2023) · Micromachines · doi:10.3390/mi14010126 · Cited by 41
Zhang, Y., Hu, P. C., Li, L. S., Cao, R., Khadria, A., Maslov, K., Tong, X., Zeng, Y., Jiang, L., Zhou, Q., et al. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01149-4 · Cited by 46
“Owing to the large dimensions of the ER compared with the acoustic wavelength, the PA waves need to propagate a long distance inside the ER; therefore, a slight change in the speed of sound due to temperature fluctuations 66 would cause large differences in the measured PACTER signal (Supplementary Video 14).”
BackgroundMethodInfluentialSkin-Conformable Flexible and Stretchable Ultrasound Transducer for Wearable Imaging
Chen, J., Liu, J., Chen, W., Shang, D., Zhang, Q., Li, Y., Zheng, H., Gu, D., Wu, D., & Ma, T. (2024) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2024.3352655 · Cited by 41
“However, the transducer elements are arranged loosely due to the limitations of electrode processing technology, making it difficult to obtain clinical-level ultrasound images, especially for high-frequency applications [25], [26].”
BackgroundA noise-tolerant human–machine interface based on deep learning-enhanced wearable sensors
Chen, X., Lou, Z., Gao, X., Yin, L., Qin, S., Lin, M., Zhang, F., Lu, Y., Ding, S., Liu, R., et al. (2025) · Nature Sensors · doi:10.1038/s44460-025-00001-3 · Cited by 77
“Similarly, precise control was maintained when the forearm was subjected to high-frequency vibrations (Extended Data Fig. and Supplementary Video 3), orientation changes (Extended Data Fig.”
InfluentialSelf-citationYuan, J., Li, Z., Zhao, Y., Luo, R., Qin, S., Li, J., Li, M., Han, G., Li, Z., Zhao, Z., et al. (2025) · Science Advances · doi:10.1126/sciadv.adw7632 · Cited by 49
“2 (E and G), the maximum acoustic pressure sensitivity reached a high level of 2.2 kPa/V with a focal point beyond 30 mm, which surpassed that of the previously reported flexible patch ( 23 , 43 ).”
Influential3D Conformal Curvy Electronics: Design, Fabrication, and Application
Jian, W., Chen, Y., & Feng, X. (2025) · ACS Nano · doi:10.1021/acsnano.5c03179 · Cited by 40
Self-citationState-of-the-art wearable sensors for cardiovascular health: a review
Xie, H., Yang, L., Jiang, B., Huang, Z., & Lin, Y. (2025) · npj Cardiovascular Health · doi:10.1038/s44325-025-00090-6 · Cited by 69
“5g) 171 .”
Transfer printing technologies for soft electronics
Huang, Z., & Lin, Y. (2022) · Nanoscale · doi:10.1039/d2nr04283e · Cited by 35
Li, Z., He, B., Li, Y., Liu, B.-F., Zhang, G., Liu, S., Hu, Y., & Li, Y. (2025) · ACS Nano · doi:10.1021/acsnano.5c04337 · Cited by 43
Self-citationFlexible adaptive sensing tonometry for medical-grade multi-parametric hemodynamic monitoring
Deng, M., Du, C., Fang, J., Xu, C., Guo, C., Huang, J., Li, K., Chen, L., Zhang, Y., Chang, Y., et al. (2024) · npj Flexible Electronics · doi:10.1038/s41528-024-00329-9 · Cited by 39
“Then, themeasurement accuracy can be evaluated by comparing the statistical differences of both the pulse waveformscollectedatthedesiredapplanationlevelbytheFASTdeviceandtheTL-400aswellasthekeycharacteristicfeaturesextractedfromthe waveforms 18 .”
InfluentialRecent advances in microsystem approaches for mechanical characterization of soft biological tissues
Song, E., Huang, Y., Huang, N., Mei, Y., Yu, X., & Rogers, J. A. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00412-z · Cited by 41
Self-citationShi, Y., Zhang, B., Zhao, J., Qin, J., Bai, K., Yu, J., & Zhang, X. (2024) · FlexMat. · doi:10.1002/flm2.27 · Cited by 36
Dutta, A., Niu, Z., Abdullah, A. M., Tiwari, N., Biswas, M. A. S., Li, B., Lorestani, F., Jing, Y., Cheng, H., & Zhang, S. (2024) · Advanced Science · doi:10.1002/advs.202303403 · Cited by 33
The advance of ultrasound-enabled diagnostics and therapeutics
Han, B., Liu, Y., Zhou, Q., Yu, Y., Liu, X., Guo, Y., Zheng, X., Zhou, M., Yu, H., & Wang, W. (2024) · Journal of Controlled Release · doi:10.1016/j.jconrel.2024.08.039 · Cited by 36
Fully Printed Flexible Ultrasound Transducer for Medical Applications
Keller, K., Leitner, C., Baumgärtner, C., Luca Benini, C., & Greco, F. (2023) · Advanced Materials Technologies · doi:10.1002/admt.202300577 · Cited by 31
Designs and Applications for the Multimodal Flexible Hybrid Epidermal Electronic Systems
Li, D., Cui, T., Xu, Z., Xu, S., Dong, Z., Tao, L., Liu, H., Yang, Y., & Ren, T. (2024) · Research · doi:10.34133/research.0424 · Cited by 39
“Although a long-wavelength ultrasonic array was adopted to minimize the sensitivity of beamforming to shape changes of the device, its effective usage range is still limited within ± 20% tensile strain [141,142].”
BackgroundSelf-citationWearable Ultrasound Devices for Therapeutic Applications
Chen, S., Ouyang, Q., Miao, X.-B., Zhang, F., Chen, Z., Qian, X., Xie, J., & Yan, Z. G. (2025) · Nano-Micro Letters · doi:10.1007/s40820-025-01890-2 · Cited by 46
Phased Array Beamforming Methods for Powering Biomedical Ultrasonic Implants
Benedict, B. C., Ghanbari, M. M., & Muller, R. (2022) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2022.3197705 · Cited by 31
“A flexible or stretchable array could conform to the skin without the need for gel, as has recently been demonstrated [32].”
BackgroundCalcium-Modified Silk Patch as a Next-Generation Ultrasound Coupling Medium
Lee, S. M., Lee, T., Kim, H., Jo, Y., Kim, M.-G., Kim, S., Bae, H., & Lee, H. J. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c16735 · Cited by 30
Self-citationAn intrinsically stretchable power-source system for bioelectronics
Cheng, P., Dai, S., Liu, Y., Li, Y., Hayashi, H., Papani, R., Su, Q., Li, N., Dai, Y., Liu, W., et al. (2023) · Device · doi:10.1016/j.device.2023.100216 · Cited by 31
Self-citationA low-voltage-driven MEMS ultrasonic phased-array transducer for fast 3D volumetric imaging
Zhang, Y., Jin, T., Deng, Y., Zhao, Z., Wang, R., He, Q., Luo, J., Li, J., Du, K., Wu, T., et al. (2024) · Microsystems & Nanoengineering · doi:10.1038/s41378-024-00755-9 · Cited by 33
“…transducers used for tissue monitoring or imaging exceeded 20 V, including conventional bulk PZT transducers and 1 – 3 composite PZT transducers 2,8,10,36,37 , as well as pMUT arrays for intracardiac imaging 31 and harmonic imaging or image-guided therapy 38 (refer to Table S1 in the…”
BackgroundMethodZhao, H., Chen, W., Li, Y., Wang, H., Li, H., Li, T., Han, F., Sun, J., Huang, L., Peng, X., et al. (2025) · Science Advances · doi:10.1126/sciadv.ads1486 · Cited by 28
“FUT is flexible but lacks inherent softness and stretchability, causing it to detach easily from the skin when the skin is stretched during certain movements ( 34 , 38 ).”
Flexible hybrid electronics: Enabling integration techniques and applications
Wu, H., Huang, Y., & Yin, Z. (2022) · Science China Technological Sciences · doi:10.1007/s11431-022-2074-8 · Cited by 32
Self-citationZeng, Q., Li, G., & Chen, W. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2023.115133 · Cited by 29
Shi, Y., Zhao, J., Zhang, B., Qin, J., Hu, X., Cheng, Y., Yu, J., Jie, J., & Zhang, X. (2024) · Advanced Materials · doi:10.1002/adma.202313603 · Cited by 27
Metadata
- Authors
- Wang, C., Qi, B., Lin, M., Zhang, Z., Makihata, M., Liu, B., Zhou, S., Huang, Y.-H., Hu, H., Gu, Y., Chen, Y., Lei, Y., Lee, T., Chien, S., Jang, K.-I., Kistler, E. B., & Xu, S.
- Affiliations
- Harvard University (US)
- University of California San Diego (US)
- Yonsei University (KR)
- Daegu Gyeongbuk Institute of Science and Technology (KR)
- Corresponding author
- Xu, Sheng
- ORCID
- Venue
- Nature Biomedical Engineering
- Published
- 2021-07-16
- Volume
- 5
- Issue
- 7
- Pages
- 749-758
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W3177774876
- Semantic Scholar
- c362c08ae1bf66f78c06e49aa3c46c3ecc0a23fa
- Cited by
- 274
- References
- 76
- Citations by year
- 2026: 42 · 2025: 78 · 2024: 62 · 2023: 51 · 2022: 34 · 2021: 7
- FWCI
- 11.70
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r21eb027303-02)
- National Institute of Biomedical Imaging and Bioengineering (R21 EB027303)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- wearable diagnostics, Doppler ultrasound, cerebral blood flow
- MeSH terms
- Wearable Electronic Devices, Cerebrovascular Circulation, Heart, Hemodynamics, Humans, Monitoring, Physiologic, Ultrasonography, Doppler, Microarray Analysis, Signal-To-Noise Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.