Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays
The DOI matches its Crossref record; 75 of the 76 references it cites were found in a registry or an index.
Abstract
Stretchable wearable devices for the continuous monitoring of physiological signals from deep tissues are constrained by the depth of signal penetration and by difficulties in resolving signals from specific tissues. Here, we report the development and testing of a prototype skin-conformal ultrasonic phased array for the monitoring of haemodynamic signals from tissues up to 14 cm beneath the skin. The device allows for active focusing and steering of ultrasound beams over a range of incident angles so as to target regions of interest. In healthy volunteers, we show that the phased array can be used to monitor Doppler spectra from cardiac tissues, record central blood flow waveforms and estimate cerebral blood supply in real time. Stretchable and conformal skin-worn ultrasonic phased arrays may open up opportunities for wearable diagnostics.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Other mechanisms of flexible health monitoring in rehabilitation, like optoelectronic[263,264] and ultrasound[265,266] devices, can also be applied to heartbeat, pulse oximetry, blood pressure, and other on-body measurements.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [265]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Materials and Mechanics for Stretchable Electronics
Rogers, J. A., Someya, T., & Huang, Y. (2010) · Science · doi:10.1126/science.1182383 · Cited by 5,042
Self-citationWearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Ommen, S. R., Nishimura, R. A., Appleton, C. P., Miller, F. A., Oh, J. K., Redfield, M. M., & Tajik, A. J. (2000) · Circulation · doi:10.1161/01.cir.102.15.1788 · Cited by 2,790
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884
Prognosis in Acute Organ-System Failure
KNAUS, W. A., DRAPER, E. A., WAGNER, D. P., & ZIMMERMAN, J. E. (1985) · Annals of Surgery · doi:10.1097/00000658-198512000-00004 · Cited by 1,225
The Assessment of Endothelial Function: From Research Into Clinical Practice
Flammer, A. J., Anderson, T., Celermajer, D. S., Creager, M. A., Deanfield, J., Ganz, P., Hamburg, N. M., Lüscher, T. F., Shechter, M., Taddei, S., et al. (2012) · Circulation · doi:10.1161/circulationaha.112.093245 · Cited by 1,153
Speckle in ultrasound B-mode scans
Burckhardt, C. B. (1978) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1978.30978 · Cited by 1,066
Cope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
Auricchio, A., Stellbrink, C., Sack, S., Block, M., Vogt, J. Ü., Bakker, P., Huth, C., Schöndube, F., Wolfhard, U., Böcker, D., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01895-8 · Cited by 1,026
Monitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895
Self-citationBiodegradable and flexible arterial-pulse sensor for the wireless monitoring of blood flow
Boutry, C. M., Beker, L., Kaizawa, Y., Vassos, C., Tran, H., Hinckley, A. C., Pfattner, R., Niu, S., Li, J., Claverie, J., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0336-5 · Cited by 862
Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care
Chung, H. U., Kim, B. H., Lee, J. Y., Lee, J., Xie, Z., Ibler, E. M., Lee, K., Banks, A., Jeong, J. Y., Kim, J., et al. (2019) · Science · doi:10.1126/science.aau0780 · Cited by 807
Self-citationMeasurement of blood flow by ultrasound: Accuracy and sources of error
Gill, R. W. (1985) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(85)90035-3 · Cited by 765
Søgaard, P., Egeblad, H., Kim, W. Y., Jensen, H. K., Pedersen, A. K., Kristensen, B. Ø., & Mortensen, P. T. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02010-7 · Cited by 603
Three-dimensional integrated stretchable electronics
Huang, Z., Hao, Y., Li, Y., Hu, H., Wang, C., Nomoto, A., Pan, T., Gu, Y., Chen, Y., Zhang, T., et al. (2018) · Nature Electronics · doi:10.1038/s41928-018-0116-y · Cited by 551
Self-citationHigh-speed ultrasound volumetric imaging system. I. Transducer design and beam steering
Smith, S. W., Pavy, H. G., & von Ramm, O. T. (1991) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.68466 · Cited by 504
Battery-free, stretchable optoelectronic systems for wireless optical characterization of the skin
Kim, J., Salvatore, G. A., Araki, H., Chiarelli, A. M., Xie, Z., Banks, A., Sheng, X., Liu, Y., Lee, J. W., Jang, K.-I., et al. (2016) · Science Advances · doi:10.1126/sciadv.1600418 · Cited by 403
Self-citationLiu, Y., Norton, J. J. S., Qazi, R., Zou, Z., Ammann, K. R., Liu, H., Yan, L., Tran, P. L., Jang, K.-I., Lee, J. W., et al. (2016) · Science Advances · doi:10.1126/sciadv.1601185 · Cited by 397
Self-citationStretchable ultrasonic transducer arrays for three-dimensional imaging on complex surfaces
Hu, H., Zhu, X., Wang, C., Zhang, L., Li, X., Lee, S., Huang, Z., Chen, R., Chen, Z., Wang, C., et al. (2018) · Science Advances · doi:10.1126/sciadv.aar3979 · Cited by 367
Self-citationGururaja, T. R., Schulze, W. A., Cross, L. E., Newnham, R. E., Auld, B. A., & Wang, Y. J. (1985) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1985.31623 · Cited by 364
Age, chronic disease, sepsis, organ system failure, and mortality in a medical intensive care unit
TRAN, D. D., JOHAN GROENEVELD, A. B., DER MEULEN, J. V., NAUTA, J. J. P., STRACK VAN SCHIJNDEL, R. J. M., & THUS, L. G. (1990) · Critical Care Medicine · doi:10.1097/00003246-199005000-00002 · Cited by 362
Lee, K., Ni, X., Lee, J. Y., Arafa, H., Pe, D. J., Xu, S., Avila, R., Irie, M., Lee, J. H., Easterlin, R. L., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0480-6 · Cited by 349
Self-citationEvolution of ultrasound beamformers
Thomenius, K. E. (2002) · 1996 IEEE Ultrasonics Symposium. Proceedings · doi:10.1109/ultsym.1996.584398 · Cited by 325
Scattering of Ultrasound by Blood
Shung, K. K., Sigelmann, R. A., & Reid, J. M. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324604 · Cited by 306
Nissen, S. E., Grines, C. L., Gurley, J. C., Sublett, K., Haynie, D., Diaz, C., Booth, D. C., & DeMaria, A. N. (1990) · Circulation · doi:10.1161/01.cir.81.2.660 · Cited by 293
A flexible organic reflectance oximeter array
Khan, Y., Han, D., Pierre, A., Ting, J., Wang, X., Lochner, C. M., Bovo, G., Yaacobi-Gross, N., Newsome, C., Wilson, R., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1813053115 · Cited by 278
Handheld Point-of-Care Ultrasound Probes: The New Generation of POCUS
Baribeau, Y., Sharkey, A., Chaudhary, O., Krumm, S., Fatima, H., Mahmood, F., & Matyal, R. (2020) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2020.07.004 · Cited by 274
Beam Steering with Linear Arrays
Von Ramm, O. T., & Smith, S. W. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325149 · Cited by 262
Galiuto, L., Ignone, G., & DeMaria, A. N. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(97)00990-9 · Cited by 258
Webb, R. C., Ma, Y., Krishnan, S., Li, Y., Yoon, S., Guo, X., Feng, X., Shi, Y., Seidel, M., Cho, N. H., et al. (2015) · Science Advances · doi:10.1126/sciadv.1500701 · Cited by 244
Self-citationA flexible and wearable terahertz scanner
Suzuki, D., Oda, S., & Kawano, Y. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.209 · Cited by 244
Merritt, C. R. B. (1987) · Journal of Clinical Ultrasound · doi:10.1002/jcu.1870150904 · Cited by 237
Resolution in ultrasound imaging
Ng, A., & Swanevelder, J. (2011) · Continuing Education in Anaesthesia Critical Care & Pain · doi:10.1093/bjaceaccp/mkr030 · Cited by 232
On phased-array radar tracking and parameter control
van Keuk, G., & Blackman, S. S. (1993) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/7.249124 · Cited by 192
Conformal phased surfaces for wireless powering of bioelectronic microdevices
Agrawal, D. R., Tanabe, Y., Weng, D., Ma, A., Hsu, S., Liao, S.-Y., Zhen, Z., Zhu, Z.-Y., Sun, C., Dong, Z., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0043 · Cited by 178
Design and fabrication of a 40-MHz annular array transducer
Ketterling, J. A., Aristizabal, O., Turnbull, D. H., & Lizzi, F. L. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1428050 · Cited by 173
Cardiac Resynchronization Therapy: Current State of the Art
Auricchio, A., & Abraham, W. T. (2004) · Circulation · doi:10.1161/01.cir.0000115583.20268.e1 · Cited by 171
Super-resolution and reconstruction of sparse sub-wavelength images
Gazit, S., Szameit, A., Eldar, Y. C., & Segev, M. (2009) · Optics Express · doi:10.1364/oe.17.023920 · Cited by 168
Gunst, M., Ghaemmaghami, V., Sperry, J. L., Robinson, M., O’Keeffe, T., Friese, R. S., & Frankel, H. L. (2008) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/ta.0b013e3181825bc5 · Cited by 140
Daum, D. R., Smith, N. B., King, R. L., & Hynynen, K. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00053-8 · Cited by 135
Flexible and Stretchable 3ω Sensors for Thermal Characterization of Human Skin
Tian, L., Li, Y., Webb, R. C., Krishnan, S., Bian, Z., Song, J., Ning, X., Crawford, K., Kurniawan, J., Bonifas, A., et al. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201701282 · Cited by 117
Self-citationCPHD-DOA Tracking of Multiple Extended Sonar Targets in Impulsive Environments
Saucan, A.-A., Chonavel, T., Sintès, C., & Caillec, J. L. (2015) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2015.2504349 · Cited by 113
Digital Auscultation Analysis for Heart Murmur Detection
Delgado‐Trejos, E., Quiceno-Manrique, A. F., Godino-Llorente, J. I., Blanco–Velasco, M., & Castellanos-Dominguez, G. (2008) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9611-z · Cited by 106
Herholz, K., Heindel, W., Rackl, A., Neubauer, I., Steinbrich, W., Pietrzyk, U., Erasmi-Korber, H., & Heiss, W.-D. (1990) · Archives of Neurology · doi:10.1001/archneur.1990.00530040034016 · Cited by 93
Measurement of blood perfusion in tissue using doppler ultrasound
Dymling, S. O., Persson, H. W., & Hertz, C. H. (1991) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(91)90179-z · Cited by 92
Medical imaging with capacitive micromachined ultrasound transducer (cMUT) arrays
Mills, D. M. (2005) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.2004.1417744 · Cited by 90
Cloostermans, M. J. T. M., & THIJSSEN, J. M. (1983) · Ultrasonic Imaging · doi:10.1177/016173468300500203 · Cited by 87
A Simulation Study of the Beam Steering Characteristics for Linear Phased Arrays
Wooh, S.-C., & Shi, Y. (1999) · Journal of Nondestructive Evaluation · doi:10.1023/a:1022645204774 · Cited by 80
Reflected ultrasound in the diagnosis of tricuspid stenosis∗
Joyner, C. R., Hey, E. B., Johnson, J., & Reid, J. M. (1967) · The American Journal of Cardiology · doi:10.1016/0002-9149(67)90263-9 · Cited by 79
Flexible Body-Conformal Ultrasound Patches for Image-Guided Neuromodulation
Pashaei, V., Dehghanzadeh, P., Enwia, G., Bayat, M., Majerus, S. J. A., & Mandal, S. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2959439 · Cited by 79
Jawad, K., Miller, J. D., Wyper, D. J., & Rowan, J. O. (1977) · Journal of neurosurgery · doi:10.3171/jns.1977.46.2.0185 · Cited by 77
More severe white matter changes in the elderly with jugular venous reflux
Chung, C., Wang, P., Wu, Y., Tsao, Y., Sheng, W., Lin, K., Lin, S., & Hu, H. (2011) · Annals of Neurology · doi:10.1002/ana.22276 · Cited by 75
Self-citationAbdelfattah, R. R., Aljumaah, S., Al-Qahtani, A. A., Althawadi, S., Barron, I., & Al-Mofada, S. M. (2017) · Journal of Hospital Infection · doi:10.1016/j.jhin.2017.09.010 · Cited by 71
Tsai, M.-H., Chen, Y., Ho, Y., Fang, J., Lien, J., Chiu, C., Liu, N., & Chen, P. (2003) · Journal of Clinical Gastroenterology · doi:10.1097/00004836-200309000-00011 · Cited by 66
Self-citationMonitoring fatigue crack growth using nonlinear ultrasonic phased array imaging
Cheng, J., Potter, J. N., Croxford, A. J., & Drinkwater, B. W. (2017) · Smart Materials and Structures · doi:10.1088/1361-665x/aa6787 · Cited by 65
Soustiel, J. F., Glenn, T. C., Vespa, P. M., Rinsky, B., Hanuscin, C. R., & Martin, N. A. (2003) · Stroke · doi:10.1161/01.str.0000080942.32331.39 · Cited by 57
Age, Chronic Disease, Sepsis, Organ System Failure, and Mortality in a Medical intensive Care Unit
Tran, D. D., Groeneveld, A. B. J., MEULEN, J. V. D., Nauta, J. J. P., van Schijndel, R. J. M. S., & THIJS, L. G. (1990) · Survey of Anesthesiology · doi:10.1097/00132586-199012000-00060 · Cited by 53
PETROFSKY, J. S. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600324 · Cited by 52
Bioelectronic devices: Wirelessly powered implants
Thimot, J., & Shepard, K. L. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0051 · Cited by 51
Ultrasound in the Diagnosis of Primary Congestive Cardiomyopathy
Abbasi, A. S., Chahine, R. A., Alpin, R. M., & Kattus, A. A. (1973) · CHEST Journal · doi:10.1378/chest.63.6.937 · Cited by 43
B-mode versus A-mode ultrasonographic measurements of mucosal thickness in vivo
Schulze, R. K. W., Ćurić, D., & d’Hoedt, B. (2002) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1067/moe.2002.119465 · Cited by 34
You, B., Chen, C., Yu, C.-P., Wang, P.-H., & Lu, J.-Y. (2018) · Optics Express · doi:10.1364/oe.26.022709 · Cited by 31
Cerebral Blood Flow Velocities by Transcranial Doppler During Parabolic Flight
Bondar, R. L., Stein, F., Kassam, M. S., Dunphy, P. T., Bennett, B. S., & Johnston, K. W. (1991) · The Journal of Clinical Pharmacology · doi:10.1002/j.1552-4604.1991.tb03648.x · Cited by 29
A Narrowband Pulse-Echo Technique for In Vivo Ultrasonic Attenuation Estimation
Jonathan Ophir, A., McWhirt, R. E., Maklad, N. F., & Jaeger, P. M. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325530 · Cited by 29
Rationale for rate-controlled drug delivery of cardiovascular drugs by the transdermal route
Breimer, D. D. (1984) · American Heart Journal · doi:10.1016/0002-8703(84)90575-1 · Cited by 20
Relationship Between BMI and Endurance-Strength Abilities Assessed by the 3 Minute Burpee Test
Podstawski, R., Bernard, K., Boraczyński, T., Boraczyński, M., & Dariusz, C. (2013) · International Journal of Sports Science · Cited by 15
Miniaturized, wearable, ultrasound probe for on-demand ultrasound screening
Bhuyan, A., Choe, J. W., Lee, B. C., Cristman, P., Oralkan, Ö., & Khuri-Yakub, B. T. (2011) · IEEE International Ultrasonics Symposium · doi:10.1109/ultsym.2011.0260 · Cited by 13
Merritt, C. R. B. (1987) · Nature · doi:10.1038/328743a0 · Cited by 13
TERAHERTZ IMAGING – PRINCIPLES, TECHNIQUES, BENEFITS, AND LIMITATIONS
Garbacz, P. (2016) · Cited by 12
The Depths from Skin to the Major Organs at Chest Acupoints of Pediatric Patients
Ma, Y.-C., Peng, C., Huang, Y., Lin, H.-Y., & Lin, J. (2015) · Evidence-based Complementary and Alternative Medicine · doi:10.1155/2015/126028 · Cited by 4
Self-citationA Practical Approach to Clinical Echocardiography
Mohan, J. C. (2014) · Jaypee Brothers Medical Publishers (P) Ltd. eBooks · doi:10.5005/jp/books/12158 · Cited by 4
Flexible ultrasonic phased-array probe
Shi, K., Que, K., & Guo, D. (2012) · Tsinghua Science & Technology · Cited by 2
Automatic image correction for flexible ultrasonic phased array inspection
Hunter, A. J., Drinkwater, B. W., Wilcox, P. D., & Russell, J. (2010) · Cited by 2
Research works printed but not linked: 1
- J. Lee, H.-S. & Sodini, C. G. in Intracranial Pressure & Neuromonitoring XVI 111–114 (Springer, 2018).
Cited by
A wearable cardiac ultrasound imager
Hu, H., Huang, H., Li, M., Gao, X., Yin, L., Qi, R., Wu, R. S., Chen, X., Ma, Y., Shi, K., et al. (2023) · Nature · doi:10.1038/s41586-022-05498-z · Cited by 644
Self-citationBioadhesive ultrasound for long-term continuous imaging of diverse organs
Wang, C., Chen, X., Wang, L., Makihata, M., Liu, H.-C., Zhou, T., & Zhao, X. (2022) · Science · doi:10.1126/science.abo2542 · Cited by 599
“Other wearable ultrasound imaging devices (12, 14-18) did not report their lateral resolutions.”
BackgroundInfluentialSelf-citationFlexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
A three-dimensional liquid diode for soft, integrated permeable electronics
Zhang, B., Li, J., Zhou, J., Chow, L., Zhao, G., Huang, Y., Ma, Z., Zhang, Q., Yang, Y., Yiu, C. K., et al. (2024) · Nature · doi:10.1038/s41586-024-07161-1 · Cited by 417
Self-citationA fully integrated wearable ultrasound system to monitor deep tissues in moving subjects
Lin, M., Zhang, Z., Gao, X., Bian, Y., Wu, R. S., Park, G., Lou, Z., Zhang, Z., Xu, X., Chen, X., et al. (2024) · Nature Biotechnology · doi:10.1038/s41587-023-01800-0 · Cited by 364
“…in response to stressors can benefit a broad range of populations, from athletes who need training optimization, to cardiac rehabilitation patients who require safety measures, and to general high-risk populations for cardiovascular risk stratification and prediction (Supplementary Discussion 19).”
InfluentialSelf-citation
Metadata
- Authors
- Wang, C., Qi, B., Lin, M., Zhang, Z., Makihata, M., Liu, B., Zhou, S., Huang, Y.-H., Hu, H., Gu, Y., Chen, Y., Lei, Y., Lee, T., Chien, S., Jang, K.-I., Kistler, E. B., & Xu, S.
- Affiliations
- Harvard University (US)
- University of California San Diego (US)
- Yonsei University (KR)
- Daegu Gyeongbuk Institute of Science and Technology (KR)
- Corresponding author
- Xu, Sheng
- ORCID
- Venue
- Nature Biomedical Engineering
- Published
- 2021-07-16
- Volume
- 5
- Issue
- 7
- Pages
- 749-758
- ISSN
- 2157-846X (ISSN-L)
- OpenAlex
- W3177774876
- Semantic Scholar
- c362c08ae1bf66f78c06e49aa3c46c3ecc0a23fa
- Cited by
- 274
- References
- 76
- Citations by year
- 2026: 42 · 2025: 78 · 2024: 62 · 2023: 51 · 2022: 34 · 2021: 7
- FWCI
- 11.70
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r21eb027303-02)
- National Institute of Biomedical Imaging and Bioengineering (R21 EB027303)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- wearable diagnostics, Doppler ultrasound, cerebral blood flow
- MeSH terms
- Wearable Electronic Devices, Cerebrovascular Circulation, Heart, Hemodynamics, Humans, Monitoring, Physiologic, Ultrasonography, Doppler, Microarray Analysis, Signal-To-Noise Ratio
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.